Search NASA⌕ Search

SEARCH · Search NASA

Results for “High Resolutions Optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Intern Sized Poster for Dosimetry Research

Federal regulations mandate that personal dosimetry devices — like optically stimulated luminescence (OSLs) — must be worn by all US Department of Energy (DOE) and associated radiation workers to track their occupational dose. Unfortunately, the inadvertent passage of OSLs through x-ray security scanners can compromise their validity. With the advent of high energy, advanced resolution security technology used in airports, this once insignificant issue now requires that Radiological Control (RadCon) be able to accurately discern non-occupational dose to effected OSLs. This presentation will discuss the principles, methods, and, rather surprising, models for establishing the corrective dose estimates at the Idaho National Laboratory (INL), and its implication across the DOE.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of Quantum Dot Loading on the Radioluminescence Efficiency in Quantum-Dot-Embedded Composites

Nanoparticle-embedded plastic scintillators are an emerging technology for fast, large-area, high-resolution radiation detection and imaging. Here, this study investigates the properties of such composites, focusing on the effects of the quantum dot (QD) concentration on the radioluminescence (RL) intensity, spectra, and dynamics. Experiments using CdSe/CdS QDs in a polymer reveal a superlinear increase in RL with the QD concentration despite optical losses from inner filtering and interparticle interactions. When corrected for inner filtering, RL shows a quadratic concentration dependence, consistent with simple analytical models of improving the secondary electron capture. Practically, the benefits of high QD concentrations are muted by optical losses, but the findings apply to other systems with insulating hosts. In addition to manipulating emission for large effective Stokes shifts, future improvements may come from hosts with higher stopping power and better charge transport, which enable more effective funneling of excitations but without concomitant optical losses associated with high nanoparticle concentrations.

Auger recombination↗

Observation of Anisotropic Dispersive Dark-Exciton Dynamics in CrSBr

Many-body excitons in CrSBr are attracting intense interest in view of their highly anisotropic magneto-optical coupling and their potential for novel optical interfaces within spintronic and magnonic devices. Characterizing the orbital character and propagation of these electronic excitations is crucial for understanding and controlling their behavior; however, this information is challenging to access. High resolution resonant inelastic x-ray scattering is a momentum-resolved technique that can address these crucial questions. Here, we present measurements collected at the Cr 𝐿 3 -edge which show a rich spectrum of excitations with a variety of spin-orbital characters. While most of these excitations appear to be localized, the dispersion of the lowest energy dark exciton indicates that it is able to propagate along both the 𝑎 and 𝑏 directions within the planes of the crystal. This two-dimensional character is surprising as it contrasts with electrical conductivity and the behavior of the bright exciton, both of which are strongly one dimensional. The discovery of this propagating dark exciton highlights an unusual coexistence of one- and two-dimensional electronic behaviors in CrSBr.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Binary pseudo-random array standards for calibration of 3D optical surface profilers used for metrology with significantly curved x-ray optics

High-accuracy metrology is vitally important in manufacturing ultra-high-quality free-form mirrors designed to manipulate X-ray light with nanometer-scale wavelengths. The current capabilities and possibility for improvements in X-ray mirror manufacturing are limited by inherent imperfections of the integrated metrology tools. In the case of Fizeau interferometry, metrology tools are currently calibrated with super-polished flat test-standard/reference mirrors. This is acceptable for measuring slightly curved X-ray optics. However, for even moderately curved aspherical X-ray mirrors the flat-reference calibration is not sufficiently accurate and stitching Fizeau interferometer-based surface metrology is used to mitigate the problem. But still, the retrace and aberration errors, as well as the limited spatial resolution, described with the instrument transfer function (ITF), can be transferred into the optical surface topography of X-ray mirrors obtained in stitching metrology. For ITF calibration, we have developed an original technique, based on test standards structured as two-dimensional (2D) highly-randomized (HR) binary pseudo-random arrays (BPRAs). The technique employs the unique properties of the HR BPRA patterns in the spatial frequency domain., i.e. the inherent 2D power spectral density of the HR BPRA pattern has a deterministic white-noise-like character that allows direct determination of the ITF with uniform sensitivity over the entire spatial frequency range and field-of-view of an instrument. Here, we explore technological, metrological, and analytical aspects essential for calibration of the retrace and aberration errors of Fizeau interferometers using different types of tilted test samples, including a super-polished reference mirror for the re-trace calibration and the uniformly redundant array (URA) BPRA standards for the geometrical distortion (aberration) calibration. While the first method was previously demonstrated by researchers at DIAMOND Light Source, a method based on the URA BPRA is described and demonstrated here for the first time. We outline the design and fabrication process used in fabrication of URA BPRA test standards, and present the results of application of the URA BPRA standards demonstrating the high efficacy of our approach to geometrical distortion calibration of Fizeau interferometers. We also discuss the possible sources of unexpected peculiarities of the systematic errors, including an astigmatic character of the retrace error, observed with Fizeau interferometers at the Advanced Light Source X-Ray Optics Laboratory.

Munechika, Keiko↗

Droplet collection efficiencies inferred from satellite retrievals constrain effective radiative forcing of aerosol–cloud interactions

Abstract. Process-oriented observational constraints for the anthropogenic effective radiative forcing due to aerosol–cloud interactions (ERFaci) are highly desirable because the uncertainty associated with ERFaci poses a significant challenge to climate prediction. The contoured frequency by optical depth diagram (CFODD) analysis supports the evaluation of model representation of cloud liquid-to-rain conversion processes because the slope of a CFODD, generated from joint MODerate Resolution Imaging Spectroradiometer (MODIS)-CloudSat cloud retrievals, provides an estimate of cloud droplet collection efficiency in single-layer warm liquid clouds. Here, we present an updated CFODD analysis as an observational constraint on the ERFaci due to warm rain processes and apply it to the U.S. Department of Energy's Energy Exascale Earth System Model version 2 (E3SMv2). A series of sensitivity experiments shows that E3SMv2 droplet collection efficiencies and ERFaci are highly sensitive to autoconversion, i.e., the rate of mass transfer from cloud liquid to rain, yielding a strong correlation between the CFODD slope and the shortwave component of ERFaci (ERFaciSW; Pearson's R=-0.91). E3SMv2's CFODD slope (0.20 ± 0.04) is in agreement with observations (0.20 ± 0.03). The strong sensitivity of ERFaciSW to the CFODD slope provides a useful constraint on highly uncertain warm rain processes, whereby ERFaciSW, constrained by MODIS-CloudSat, is estimated by calculating the intercept of the linear association between the ERFaciSW and the CFODD slopes, using the MODIS-CloudSat CFODD slope as a reference.

Beall, Charlotte M. (ORCID:0000000311370835)↗

Precision measurement of lifetime and branching ratios of the 4⁢𝑓 13⁡ 5⁢𝑑⁢6⁢𝑠 1 ⁢[5/2] 5/2 state in Yb + ions

We report spectroscopic and time-resolved experimental observations to characterize the [Xe]⁢4⁢𝑓 13 ⁡( 2 𝐹$^𝑜_{5/2}$)⁢5⁢𝑑⁢6⁢𝑠⁡( 1 𝐷)⁢ 1 ⁢[5/2]$^𝑜_{5/2}$ state in 172 Yb + ions. We access this state from the metastable 4⁢𝑓 14 ⁡5⁢𝑑⁡( 2 𝐷 3/2,5/2 ) manifold and observe an unexpectedly long lifetime of 𝜏 = 37.9⁢(9) ⁢µ⁢s that allows visible Rabi oscillations and resolved-sideband spectroscopy. Using a combination of coherent population dynamics, high-fidelity detection and heralded state preparation, and optical pumping methods, we measure the branching ratios to the 2 𝐷 3/2 , 2 𝐷 5/2 , and 2 𝑆 1/2 states to be 0.359⁢(2), 0.639(2), and 0.0023⁢(16), respectively. The branching ratio to the 4⁢𝑓 13⁡ 6⁢𝑠 2 ⁡( 2 𝐹 7/2 ) is compatible with zero within our experimental resolution. We also report measurements of Landé 𝑔-factor of the 1 ⁢[5/2]$^𝑜_{5/2}$ state. Further, the branching ratio of the 2 𝐷 5/2 to 2 𝑆 1/2 decay in 172 Yb + was measured to be 0.188(3), improving its relative uncertainty by an order of magnitude. Our measurements provide experimental benchmarks for better understanding the atomic structure of Yb + ions, which still lacks accurate numerical descriptions, and the use of high-lying excited states for partial detection and qubit manipulation in the omg architecture.

74 ATOMIC AND MOLECULAR PHYSICS↗

Simultaneous measurement of temperature and strain by cascaded fiber Bragg grating-silicon Fabry-Perot interferometer sensor

We report a fiber-optic sensor configuration with a cascaded fiber Bragg grating (FBG) and a silicon Fabry-Perot interferometer (FPI) for simultaneous measurement of temperature and strain. The sensor is composed of a 5 mm FBG on a single mode fiber and a 100μm thick silicon FPI attached to the tip of the optical fiber. The FBG is surface mounted on the host structure, and the FPI tip is suspended. Due to the stress-free, cantilever configuration, the silicon FPI is insensitive to strain, but sensitive to temperature with a sensitivity much higher than the FBG due to the large thermo-optic coefficient of silicon. The sensor is tested from room temperature to 100°C with varying strain up to ∼150με. The silicon FPI provides high temperature sensitivity of 89 pm/°C unaffected by strain. Since the FBG is attached to the host structure, it is affected by both thermal and mechanical strain; the sensitivity of these was experimentally obtained 32 pm/°C and 1.09 pm / με, respectively. Interrogated with a broadband light source and a high-speed spectrometer, the sensor shows temperature and strain resolutions of 1.9 × 10 −3 °C and 0.042 με, respectively. Here, due to the small size, enhanced sensitivity, and high resolution, this cascaded FBG-FPI sensor can be used in applications where accurate measurement of temperature and strain is required.

42 ENGINEERING↗

Phase-resolving spin-wave microscopy using infrared strobe light

The need for sensitively and reliably probing magnetization dynamics has been increasing in various contexts such as studying novel hybrid magnonic systems, in which the spin dynamics strongly and coherently couple to other excitations, including microwave photons, light photons, or phonons. Recent advances in quantum magnonics also highlight the need for employing the magnon phase as quantum state variable, which is to be detected and mapped out with high precision in on-chip micro- and nanoscale magnonic devices. Here, in this study, we demonstrate a facile optical technique that can directly perform concurrent spectroscopic and imaging functionalities with spatial and phase resolutions, using infrared strobe light operating at 1550-nm wavelength. To showcase the methodology, we spectroscopically studied the phaseresolved spin dynamics in a bilayer of Permalloy and yttrium iron garnet Y 3 Fe 5 O 12 (YIG), and spatially imaged the backward-volume spin-wave modes of YIG in the dipolar spin-wave regime. Using the strobe light probe, the detected precessional phase contrast can be directly used to construct the map of the spin wave's wave front, in the continuous-wave regime of spin-wave propagation and in the stationary state, without needing any optical reference path. By selecting the applied field, frequency, and detection phase, the spin-wave images can be made sensitive to the precession amplitude and phase. Our results demonstrate that infrared optical strobe light can serve as a versatile platform for magneto-optical probing of magnetization dynamics, with potential implications in investigating hybrid magnonic systems.

Xiong, Yuzan [University of North Carolina, Chapel↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Label-free structural imaging of plant roots and microbes using third-harmonic generation microscopy

Root biology is pivotal in addressing global challenges including sustainable agriculture and climate change. However, roots have been relatively understudied among plant organs, partly due to the difficulties in imaging root structures in their natural environment. Here we used microfabricated ecosystems (EcoFABs) to establish growing environments with optical access and employed nonlinear multimodal microscopy of third-harmonic generation (THG) and three-photon fluorescence (3PF) to achieve label-free, in situ imaging of live roots and microbes at high spatiotemporal resolution. THG enabled us to observe key plant root structures including the vasculature, Casparian strips, dividing meristematic cells, and root cap cells, as well as subcellular features including nuclear envelopes, nucleoli, starch granules, and putative stress granules. THG from the cell walls of bacteria and fungi also provides label-free contrast for visualizing these microbes in the root rhizosphere. With simultaneously recorded 3PF signal, we demonstrated our ability to investigate root-microbe interactions by achieving single-bacterium tracking and subcellular imaging of fungal spores and hyphae in the rhizosphere.

Pan, Daisong [University of California, Berkeley, ↗

First field test of a novel optical gas analyser in the exhaust of Wendelstein 7-X

A novel optical gas analyser, designed for isotope-resolved exhaust composition measurement, was field-tested at Wendelstein 7-X (W7-X) to validate its laboratory-proven concept under operational fusion experiment conditions. The system, Optix, comprises a cold cathode remote plasma generator and a high-resolution Fabry–Perot spectrometer and was deployed in the exhaust line of W7-X during the OP2.3 campaign. The injection of 3 He and 4 He for minority ion-cyclotron heating provided a test case for helium isotope discrimination. Despite limitations due to background gas and low partial pressures of the target species, isotope-resolved spectral signatures were successfully observed, demonstrating the fundamental viability of the Optix approach. Additionally, the spectrometer was evaluated for plasma emission measurements from both core and edge sightlines. While helium line emission was detectable, interpretation was hindered by complex background signals, highlighting the benefits of controlled remote plasma generators for spectroscopy. This first deployment provides critical insight into pressure requirements, spectral resolution, and operational constraints, informing future applications of optical exhaust diagnostics in fusion devices.

magnetic confinement fusion↗

Device response principles and the impact on energy resolution of epitaxial quantum dot scintillators with monolithic photodetector integration

Abstract Epitaxial quantum dot (QD) scintillator crystals with picosecond-scale timing and high light yield have been created for medical imaging, high energy physics and national security applications. Monolithic photodetector (PD) integration enables the sensing of photons generated within the waveguiding crystal and allows a wide range of scintillator-photodetector coupling geometries. Until recently, these doubly novel devices have suffered from complex, high variance responses to monoenergetic sources which significantly reduces their precision and accuracy. The principles governing the overall device response have now been discerned and embodied by an expression derived within a geometrical optics framework which considers optical properties, surface roughness and photodetector coupling geometry. Response variation due to these factors was sufficiently reduced to obtain material-related energy resolution values of 2.4% with alpha particles. These findings place energy resolution alongside luminescence timescale, photon yield, and radiation hardness as outstanding properties of these engineered materials.

36 MATERIALS SCIENCE↗

Microwave-photonic control of optically accessible spin defects in diamond

A growing variety of optically accessible spin qubits have emerged in recent years as key components for quantum sensors, computers, and memories. However, the scalability of conventional spin-based quantum architectures remains limited by direct microwave delivery, which introduces thermal noise, electromagnetic crosstalk, and design constraints for cryogenic, high-field, and distributed systems. In this work, we present a unified framework for RF-over-fiber (RFoF) control of spins accessible through optically detected magnetic resonance (ODMR) spectroscopy of nitrogen-vacancy (NV) centers in diamond. The RFoF platform relies on an intensity-modulated 1310 nm laser carrying microwave signals over fiber and a high-speed photodiode for optical-to-electrical conversion to drive NV spin transitions. We report an RFoF power-conversion efficiency of 3.42% for an RF output PRF,out=-5.5 dBm at 2.87 GHz, enabling clear resolution of Zeeman splitting in

Rahman, M Reefaz [ORNL] (ORCID:0000000323541611)↗

Explainable machine learning for incipient anomaly detection in compact molten salt heat exchanger with overlapping feature distributions

High-temperature molten salt-cooled reactors (MSCRs) are a promising next-generation nuclear technology option, offering efficient power conversion and inherent safety features. However, the reliability of these systems depends on the robust operation of heat exchangers (HXs), which are susceptible to failure due to temperature gradients and channel plugging caused by fluid freezing. Conventional monitoring methods, relying on inlet and outlet measurements, lack the spatial resolution needed to detect early-stage faults. We propose a novel design of a compact salt-to-salt matrix-type HX design consisting of interleaved arrays of parallel tubes, with integrated synthetic fiber optic distributed temperature sensing (DTS) to enable localized detection of incipient faults. To evaluate performance of this design, we generate high-fidelity synthetic data using heat transfer computational modeling to simulate channel plugging, and introduce sensor noise for realistic modeling of measurements. The dataset comprises of 97% normal operation and 3% anomaly cases, with each anomaly class representing 1% of the data. These early anomalies result in overlapping temperature profiles between normal and faulty channels, producing a non-separable dataset that challenges traditional classification techniques. We benchmark eight supervised machine learning (ML) models and demonstrate that XGBoost achieves the highest performance. To improve transparency, we develop an explainability framework combining Shapley values and partially ordered sets (POSETs) to quantify and structurally analyze feature importance. This approach identifies both dominant predictors and ambiguous feature relationships, enhancing trust and interpretability. Our results highlight the potential of combining DTS and explainable ML with intelligent feature selection to improve predictive maintenance and ensure operational resilience in advanced nuclear systems.

Prantikos, Konstantinos [Argonne National Laborato↗

Wafer-scale waveguide sidewall roughness scattering loss characterization by image processing

Photonic integrated circuits (PICs) are vital for developing affordable, high-performance optoelectronic devices that can be manufactured at an industrial scale, driving innovation and efficiency in various applications. Optical loss of modes in thin film waveguides and devices is a critical measure of their performance. Thin film growth, lithography, masking, and etching processes are imperfect processes that introduce significant sidewall and top-surface roughness and cause dominating optical losses in waveguides and photonic structures. This roughness, as perturbations couple light from guided to far-field radiation modes, leads to scattering losses that can be estimated from theoretical models. Typically, with UV-based lithography, sidewall roughness is significantly larger than wafer-top surface roughness. Atomic force microscopy (AFM) imaging measurement gives a 3D and high-resolution roughness profile, but the measurement is inconvenient, costly, and unscalable for large-scale PICs and at wafer-scale. Here, we evaluate the sidewall roughness profile based on 2D high-resolution scanning electron microscope (SEM) imaging. We characterized the loss on two homemade nitride and oxide films on 3-inch silicon wafers with 12 waveguide devices on each and correlated the scattering loss estimated from a 2D image-based sidewall profile and theoretical Payne model. The lowest loss of guided fundamental transverse electric (TE 0 ) mode is found at 0.075 dB/cm at 633 nm across 24 devices, a record at visible wavelength. Our work shows 100% success (edge continuity span exceeding 95% of image width/height) in edge detection in image processing of all images to estimate autocorrelation function and optical mode loss. These demonstrations offer valuable insights into waveguide sidewall roughness and a comparison of experimental and 2D SEM image processing based loss estimations with applications in loss characterization at wafer-scale PICs.

Khurana, Mohit (ORCID:0000000207898672)↗

Examining Cloud Feedback Components in the Simple Cloud-Resolving E3SM Atmosphere Model (SCREAM)

Cloud feedback remains the main source of uncertainty in climate sensitivity estimated by global climate models (GCMs), largely because subgrid cloud responses are parameterized in GCMs due to their coarse resolution. Here, this study examines cloud feedback in the global 3.25-km Simple Cloud-Resolving Energy Exascale Earth System Model (E3SM) Atmosphere Model (SCREAM 3 km) through a pair of 1-yr atmosphere-only simulations with control and +4-K sea surface temperature perturbations. SCREAM 3 km produces a positive cloud feedback that falls within but at the upper end of the range of Coupled Model Intercomparison Project phase 5 (CMIP5) and CMIP phase 6 (CMIP6) models and expert judgment. The positive cloud feedback arises from positive contributions from both high- and low-level clouds, with increases in high-cloud altitude and decreases in low-cloud amount and optical depth playing key roles. The stronger-than-CMIP-average feedback is mainly attributable to the high-cloud altitude feedback, owing to cloud tops rising nearly isothermally in SCREAM 3 km. The positive low-cloud amount feedback is weaker in SCREAM than in GCMs because estimated inversion strength (EIS) increases more dramatically with warming. A coarser 12-km resolution version of SCREAM exhibits a weaker positive cloud feedback than SCREAM 3 km, mainly because its low-cloud-radiative flux is more sensitive to EIS, leading to a stronger negative low-cloud amount feedback. With this process-level assessment of cloud feedback, this study reveals where SCREAM aligns with and diverges from conventional GCMs and expert assessment, providing insights to inform further model improvement and future expert assessment.

Cloud radiative effects↗

Impact of the Annealing Temperature on the Local Se Distribution and Optical Properties in CdSexTe1-x Solar Cells by Multimodal X-ray Microscopy

The introduction of Se in CdTe solar-cell absorbers has led to multiple beneficial effects in the devices, including an increased short-circuit current and an extended charge-carrier lifetime. A critical manufacturing step of CdSexTe1-x solar cells is CdCl2 annealing at high temperatures, during which Se diffuses through the absorber layer. Understanding the local Se distribution in the absorber and its impact on optical properties of the material is key for the further development of this thin-film solar cell technology. In a multimodal x-ray scanning microscopy approach, we investigated the impact of the annealing temperature of CdSexTe1-x solar cells on the Se distribution and on optical characteristics of the material. For this purpose, we exploited an upgraded x-ray excited optical luminescence (XEOL) detection unit that enables simultaneous spectrally and temporally resolved XEOL mapping at synchrotron facilities that are ideal for studying thin-film solar-cell materials with hard x-rays featuring high penetration depth and lateral resolution.

14 SOLAR ENERGY↗

Deep-ultraviolet ptychographic pocket-scope (DART): mesoscale lensless molecular imaging with label-free spectroscopic contrast

The mesoscale characterization of biological specimens has traditionally required compromises between resolution, field-of-view, depth-of-field, and molecular specificity, with most approaches relying on external labels. Here we present the Deep-ultrAviolet ptychogRaphic pockeT-scope (DART), a handheld platform that transforms label-free molecular imaging through intrinsic deep-ultraviolet spectroscopic contrast. By leveraging biomolecules’ natural absorption fingerprints and combining them with lensless ptychographic microscopy, DART resolves down to 308-nm linewidths across centimeter-scale areas while maintaining millimeter-scale depth-of-field. The system’s virtual error-bin methodology effectively eliminates artifacts from limited temporal coherence and other optical imperfections, enabling high-fidelity molecular imaging without lenses. Through differential spectroscopic imaging at deep-ultraviolet wavelengths, DART quantitatively maps nucleic acid and protein distributions with femtogram sensitivity, providing an intrinsic basis for explainable virtual staining. We demonstrate DART’s capabilities through imaging of tissue sections, cytopathology specimens, blood cells, and neural populations, revealing detailed molecular contrast without external labels. The combination of high-resolution molecular mapping and broad mesoscale imaging in a portable platform opens new possibilities from rapid clinical diagnostics, tissue analysis, to biological characterization in space exploration.

60 APPLIED LIFE SCIENCES↗