Effect of plastic set on thermal conductance at light loading
Feasibility of using elastic deformation to predict heat transfer rates across joined smooth-metal surfaces under high vacuum conditions and light loads
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Feasibility of using elastic deformation to predict heat transfer rates across joined smooth-metal surfaces under high vacuum conditions and light loads
Here, the dynamic cracking processes in porcine cortical bone were visualized in real-time using the high-speed synchrotron X-ray phase-contrast imaging (PCI) technique in three osteon orientations: in-plane transverse, out-of-plane transverse and in-plane longitudinal. The dynamic flexural loading applied on the pre-notched bone specimens was introduced by a modified Kolsky compression bar. High-speed X-ray images of the entire loading events were documented with a high-speed camera. Three-dimensional X-ray micro-computed tomography was conducted to examine the intact microstructures and obtain the basic material properties of the bone material used for mechanical characterizations. The onset location, where crack initiated, and the subsequent direction, along which the incipient crack propagated, were measured quantitatively using the high-speed X-ray images and the latter was found dependent on the osteon direction significantly. The crack propagation velocities were dependent on crack extension over the entire crack path significantly for all the three directions while the initial velocity for in-plane longitudinal direction was lower than the other two directions. Straight-through crack paths were observed for in-plane longitudinal specimens while the cracks were deflected and twisted in the in-plane transverse direction. For out-of-plane transverse direction, the cracks follow paths with tortuosity fall in between the other two directions, showing a mixed mode of fractures of the former two extreme cases. The toughening mechanisms, visualized by the high-speed X-ray images, and the corresponding fracture toughness, evaluated in terms of fracture initiation toughness and crack growth resistance curve (R-curve), were also found significantly different among the three osteon directions, suggesting an overall transition from brittle to ductile-like fracture behaviors at the dynamic displacement rate (5.4 m/s) as the osteon orientation varies from in-plane longitudinal to out-of-plane transverse, and to in-plane transverse eventually.
To study the influence of temperature on the rate of fatigue crack growth in high strength metal alloys, constant load amplitude fatigue crack growth experiments were carried out using a .25-in.-thick mill annealed Ti-6Al-4V alloy plate. The rates of fatigue crack growth were determined as a function of temperature, ranging from room temperature to about 290 C, and as a function of the crack tip stress intensity factor in a dehumidified high purity argon environment. Limited correlative experiments were carried out in distilled water, dehumidified oxygen and hydrogen, and in vacuum. The results indicate that the rate of fatigue crack growth is essentially independent of test temperature in this alloy, and is affected by residual moisture in very small concentrations. Companion fractographic examinations suggest that the mechanims for fatigue crack growth in the various environments are essentially the same.
Nearest neighbors search is a core operation found in several online multimedia services. These services have to handle very large databases, while, at the same time, they must minimize the query response times observed by users. This is specially complex because those services deal with fluctuating query workloads (rates). Consequently, they must adapt at run-time to minimize the response times as the load varies. In this paper, we address the aforementioned challenges with a distributed memory parallelization of the product quantization nearest neighbor search, also known as IVFADC, for hybrid CPU–GPU machines. Overall, our parallel IVFADC implements an out-of-GPU memory execution scheme to use the GPU for databases in which the index does not fit in its memory, which is crucial for searching in very large databases. The careful use of CPU and GPU with work stealing led to an average response time reduction of 2.4 as compared to using the GPU only. Also, our approach to adapt the system to fluctuating loads, called Dynamic Query Processing Policy (DQPP), attained a response time reduction of up to 5 vs. the best static (BS) policy for moderate loads. The system has attained high query processing rates and near-linear scalability in all experiments. We have evaluated our system on a machine with up to 256 NVIDIA V100 GPUs processing a database of 256 billion SIFT features vectors.
The manufacturers of Nationally Recognized Testing Laboratory (NRTL) listed, switch-rated, plug and receptacle combinations tout their convenience, reliability, efficiency, and compliance with both the National Fire Protection Association (NFPA) 70®, National Electric Code (NEC), and National Fire Protection Association 70E®, The Standard for Electrical Safety in the Workplace, as advantages to using these products in lieu of traditional metal-enclosed disconnect switches. The purpose of this paper is to raise awareness of several unintended consequences that can result when replacement involves high energy cord and plug connected equipment. This paper describes several possible issues in complying with the NFPA 70 Articles 110 and 400 and NFPA 70E Articles 110 and 130 that should be considered when using load rated plug/receptacle combinations. This paper is intended to address high energy circuits typically associated with 480 volt pin and sleeve type connections in applications where incident energy levels may exceed 1.2 calories/centimeter² (cal/cm²).
To understand the influence temperature on the rate of fatigue crack growth in high strength metal alloys, constant load amplitude, fatigue crack growth experiments were carried out using a 1/4-inch-thick (6.35 mm) mill annealed Ti-6Al-4V alloy plate as a model material. The rates of fatigue crack growth were determined as a function of temperature, ranging from room temperature to about 290 C (or, about 550 F/563K) and as a function of the crack tip stress intensity factor in a dehumidified high purity argon environment. Limited correlative experiments indicate that dehumidified oxygen and hydrogen have no effect on the rate of fatigue crack growth in this alloy, while distilled water increased the rate of crack growth slightly in the range tested. Companion fractographic examinations suggest that the mechanisms for fatigue crack growth in the various environments are essentially the same.
As countries around the world transition towards renewable energy, there is increasing interest in using photovoltaic (PV) technologies to help decarbonize remote northern communities due to their scalability and affordability. However, a major barrier towards large-scale adoption of PV in cold climates is performance uncertainty under extreme environmental conditions including snowfall, freeze-thaw cycles, and high wind loads. Existing literature on PV degradation rates in the North is relatively limited, with published degradation rates varying between -0.2%/year (Sweden) to -1.3%/year (Scotland). At this workshop, we will present preliminary results on the long-term performance of two diverse photovoltaic sites located in Fairbanks, Alaska at 64.8 degrees N: a monofacial Al-BSF double-axis tracking site maintained by the Cold Climate Housing Research Center (CCHRC), and a bifacial PERC/SHJ E-W vertical and south-facing fixed-tilt site maintained by the Alaska Center Energy and Power (ACEP). CCHRC data has been collected over a period of 15 years, while ACEP site data has been collected over 4 years. Using the degradation analysis tool, RdTools, we will present annual system degradation rates, seasonal performance ratio, and identify potential cold climate failure mechanisms for commercially available PV technologies. This analysis will add to existing literature by directly comparing the performance of multiple PV configurations in Alaska.
To understand the influence of temperature on the rate of fatigue crack growth in high strength metal alloys, constant load amplitude fatigue crack growth experiments were carried out using a 1/4 inch thick (6.35 mm) mill-annealed Ti-6Al-4V alloy plate as a model material. The rates of fatigue crack growth were determined as a function of temperature, ranging from room temperature to about 290 C and as a function of the crack tip, stress intensity factor K, in dehumidified high purity argon environment. The dependence of the rate of fatigue crack growth on K appears to be separable into two regions. The transition correlates with changes in both the microscopic and macroscopic appearances of the fracture surfaces, and suggests a change in the mechanism and the influence of microstructure on fatigue crack growth.
Abstract Longitudinal phase space (LPS) provides a critical information about electron beam dynamics for various scientific applications. For example, it can give insight into the high-brightness X-ray radiation from a free electron laser. Existing diagnostics are invasive, and often times cannot operate at the required resolution. In this work we present a machine learning-based Virtual Diagnostic (VD) tool to accurately predict the LPS for every shot using spectral information collected non-destructively from the radiation of relativistic electron beam. We demonstrate the tool’s accuracy for three different case studies with experimental or simulated data. For each case, we introduce a method to increase the confidence in the VD tool. We anticipate that spectral VD would improve the setup and understanding of experimental configurations at DOE’s user facilities as well as data sorting and analysis. The spectral VD can provide confident knowledge of the longitudinal bunch properties at the next generation of high-repetition rate linear accelerators while reducing the load on data storage, readout and streaming requirements.
Abstract Aerosol-boundary layer interactions play an important role in affecting atmospheric thermodynamics and air pollution. As a key factor in dictating the development of the boundary layer, the entrainment process in the context of aerosol-boundary layer interactions is still poorly understood. Using comprehensive field observations made at a superstation in Beijing, we gain insight into the response of the entrainment process to aerosols. We found that high aerosol loading can significantly suppress the entrainment rate, breaking the conventional linear relationship between sensible heat fluxes and entrainment fluxes. Related to aerosol vertical distributions, aerosol heating effects can alter vertical heat fluxes, leading to a strong interaction between aerosols and the entrainment process in the upper boundary layer. Such aerosol-entrainment coupling can inhibit boundary layer development and explains the great sensitivity of observed entrainment rates to aerosols than can traditional calculations. The notable impact of aerosols on the entrainment process raises holistic thinking about the dynamic framework of the boundary layer in a polluted atmosphere, which may have a significant bearing on the dispersion of air pollutants and the land-atmosphere coupling.
Combining an x-ray free electron laser with a high-power laser driver enables the study of equations-of-state, high strain-rate deformation processes, structural phase transitions, and transformation pathways as a function of pressure to hundreds of GPa along different thermodynamic compression paths. Future high repetition-rate laser operation will enable data to be accumulated at >1 Hz, which poses a number of experimental challenges, including the need to rapidly replenish the target. Here, we present a combined shock compression and an x-ray diffraction study on epoxy (50% vol.)-crystalline grains (50% vol.) slurry targets, which can be fashioned into extruded ribbons for high repetition-rate operation. For shock-loaded NaCl-slurry samples, we observe pressure, density, and temperature states within the embedded NaCl grains consistent with observations from shock-compressed single-crystal NaCl.
Epithelial cells experience long lasting loads of different magnitudes and rates. How they adapt to these loads strongly impacts tissue health. Yet, much remains unknown about the evolution of cellular stress in response to sustained strain. Here, by subjecting cell pairs to sustained strain, we report a bimodal stress response, where in addition to the typically observed stress relaxation, a subset of cells exhibits a dynamic tensioning process with significant elevation in stress within 100 s, resembling active pulling-back in muscle fibers. Strikingly, the fraction of cells exhibiting tensioning increases with increasing strain rate. The tensioning response is accompanied by actin remodeling, and perturbation to actin abrogates it, supporting cell contractility’s role in the response. Collectively, our data show that epithelial cells adjust their tensional states over short timescales in a strain-rate dependent manner to adapt to sustained strains, demonstrating that the active pulling-back behavior could be a common protective mechanism against environmental stress.
The safety and reliability of next-gen reactors, i.e. molten salt reactors (MSR), depends on materials performance and longevity in extreme environments, yet no in-situ, validated measurement techniques for environmentally assisted cracking (EAC), one potential degradation mechanism, exist for these conditions. This project combined the use of in-situ direct current potential drop (DCPD) crack growth rate determination applied to a horizontal load frame with high temperature fittings and novel sample geometries to enable evaluation in MSR environments and develop a full in-situ SCC measurement capability for extreme environments (high conductivity and elevated T), necessary to predict materials reliability. A successful demonstration of DCPD measurement in molten NaNO 3 /KNO 3 salts at 340 o C was accomplished and validated through post-test fractography imaging. This is the first ever public example, to the authors knowledge, of an in-situ crack growth rate measurement in a molten salt environment.
Due to its numerous practical applications and intriguing phase transformation behavior, shape memory alloys (SMAs) have garnered significant research and development interests. In the past, most studies on the mechanical behavior of SMAs have been conducted under uniaxial stress loadings. Limited research on SMAs under shock loading has not provided conclusive results regarding their transformation behavior and transformation stress under such loading. Additionally, there is a lack of comprehensive understanding regarding the effects of different stress states on transformation behavior. The main objectives of this study are to address these issues. To achieve these objectives, a series of shock wave experiments were designed and conducted. Additionally, quasi-static and dynamic uniaxial stress experiments were carried out to establish a baseline for comparison. The results revealed that the transformation stress under dynamic uniaxial strain shock loading was approximately 1.92 GPa in contrast to 0.5 GPa (quasi-static) to 0.8 GPa (dynamic) observed in uniaxial stress loading. The transformation behavior exhibited noticeable rate sensitivity for both types of loading. There appeared to be a critical strain rate above which the austenite phase was driven to a metastable state. This estimated critical axial strain rate along the loading direction was approximately 2 × 10 3 /s–4 × 10 3 /s for uniaxial stress loading and approximately 2 × 10 6 /s for uniaxial strain loading. The apparent high transformation stress for uniaxial strain loading can likely be attributed to a combination of high-pressure confinement and high strain rate. Furthermore, determining their relative contributions remains an open issue.
Two different polyimide polymers were studied and the effectiveness of a design feature to improve retention of the self lubricating composite liners under high load was evaluated. The basic bearing design consisted of a molded layer of chopped graphite-fiber-reinforced-polyimide (GFRP) composite bonded to the bore of a steel bushing. The friction, wear, and load carrying ability of the bushings were determined in oscillating tests at 25, 260 and 315 C at radial unit loads up to 260 MPa. Friction coefficients were typically 0.15 to 0.25. Bushings with liners containing a new partially fluorinated polymer were functional, but had a lower load capacity and higher wear rate than those containing a more conventional, high temperature polyimide. The liner retention design feature reduced the tendency of the liners to crack and work out of the contact zone under high oscillating loads.
The practical deployment of lithium–sulfur batteries (LSBs) is hindered by fundamental limitations in conventional slurry-cast cathodes, including poor sulfur utilization, sluggish ion transport, and low areal capacity, particularly in thick electrodes required for high energy density. To address these challenges, we present direct ink writing (DIW) as an additive manufacturing strategy to fabricate advanced current-collector-free, 3D-printed sulfur cathodes (3DP S@CoNi-DSACs/NC) with hierarchically porous architectures that enhance lithium-ion diffusion, promote electrolyte penetration, and reduce interfacial resistance. The synergistic effects of Co/Ni dual-atom sites accelerate redox kinetics and mitigate polysulfide shuttling. As a result, the optimized 3DP cathode with a sulfur loading of 5.4 mg cm −2 demonstrated excellent rate capability, delivering a high reversible capacity of 1041.4 mAh g −1 at 1C with 85.5% capacity retention after 1000 cycles, significantly outperforming its cast counterpart. Remarkably, even at a higher sulfur loading of 8.1 mg cm −2 , the 3DP cathode maintains outstanding performance, achieving a discharge capacity of 1538.4 mAh g −1 and an areal capacity of 12.5 mAh cm −2 at 0.1C. This study not only demonstrates the functional integration of catalytically active materials into 3D printable sulfur cathode architectures but also offers a scalable and transformative platform for building high-performance LSBs beyond conventional electrode manufacturing methods.
This paper presents a grid impact analysis of heavy-duty electric vehicle (EV) charging stations. In this work, heavy-duty EVs have battery capacities high enough to provide a range of 250-500 miles on a single charge, such as long-haul trucks. Heavy-duty EVs will require extremely fast charging rates to reduce charging time and will induce very high charging loads (at the multiple-megawatt scale) if several vehicles charge at the same time. Therefore, analysis is needed to understand the impact of charging station loads on the electric power grid and set the baseline for developing mitigation plans and necessary system upgrades. We develop a systematic procedure to analyze the potential impact of the placement of charging stations on the grid. Charging load is modeled using a DC fast-charging station model. A voltage load sensitivity matrix approach is leveraged to investigate the challenges of placing charging stations on the feeder. Given the charging load profiles and suggested charging station locations, time-series simulations are performed on various connection points on the feeder to understand the impact. The analysis is performed on both the IEEE 34-bus system and a realistic feeder from California. Initial mitigation solutions are developed based on insights from this analysis.
The crack-closure and crack-growth characteristics of the titanium alloy Ti-6Al-4V were determined experimentally on surface-flawed plate specimens. Under cyclic loading from zero to tension, cracks deeper than 1 mm opened at approximately 50 percent of the maximum load. Cracks shallower than 1 mm opened at higher loads. The correlation between crack-growth rate and the total stress-intensity range showed a lower threshold behavior. This behavior was attributed to the high crack-opening loads at short cracks because the lower threshold was much less evident in correlations between the crack-growth rates and the effective stress-intensity range.