Search NASA⌕ Search

SEARCH · Search NASA

Results for “High resolution spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

X-ray Weak Broad-line Qquasars: Absorption or Intrinsic X-ray Weakness

XMM observations of X-ray weak quasars have been performed during 2003 and 2004. The data for all the observations have become available in 2004 (there has been a delay of several months on the initial schedule, due to high background flares which contaminated the observations: as a consequence, most of them had to be rescheduled). We have reduced and analyzed all the data, and obtained interesting scientific results. Out of the eight sources, 4 are confirmed to be extremely X-ray weak, in agreement with the results of previous Chandra observations. 3 sources are confined to be highly variable both in flux (by factor 20-50) and in spectral properties (dramatic changes in spectral index). For both these groups of objects we are completing a publication: 1) For the X-ray weak sources, a paper is submitted with a complete analysis of the X-ray spectra both from Chandra and XMM-Newton, and a comparison with optical and near-IR photometry obtained from all-sky surveys. Possible models for the unusual spectral energy distribution of these sources are also presented. 2) For the variable sources, a paper is being finalized where the X-ray spectra obtained with XMM-Newton are compared with previous X-ray observations and with observations at other wavelengths. It is shown that these sources are high luminosity and extreme cases of the highly variable class of narrow-line Seyfert Is. In order to further understand the nature of these X-ray weak quasars, we submitted proposals for spectroscopy at optical and infrared telescopes. We obtained time at the TNG 4 meter telescope for near-IR observations and at the Hobby-Eberly Telescope for optical high-resolution spectroscopy. These observations have been performed in early 2004. They will complement the XMM data and will lead to understanding of whether the X-ray weakness of these sources is an intrinsic property or is due to absorption by circum-nuclear material. The infrared spectra of the variable sources have been already analyzed and are discussed in the paper by Memola et al. which will be soon submitted.

Mushotzky, Richard↗

Use of PZT's for adaptive control of Fabry-Perot etalon plate figure

A Fabry Perot etalon, consisting of two spaced and reflective glass flats, provides the mechanism by which high resolution spectroscopy may be performed over narrow spectral regions. Space based applications include direct measurements of Doppler shifts of airglow absorption and emission features and the Doppler broadening of spectral lines. The technique requires a high degree of parallelism between the two flats to be maintained through harsh launch conditions. Monitoring and adjusting the plate figure by illuminating the Fabry Perot interferometer with a suitable monochromatic source may be performed on orbit to actively control of the parallelism of the flats. This report describes the use of such a technique in a laboratory environment applied to a piezo-electric stack attached to the center of a Fabry Perot etalon.

Skinner, WIlbert↗

Highly Charged Ions in a New Era of High Resolution X-Ray Astrophysics

X‐ray astronomy and ground‐based atomic physics have a long history of fruitful collaboration: Sound understanding of the underlying atomic physics is the key to reliable interpretation of the spectra from celestial sources; conversely, astronomical spectra have been used to benchmark and advance atomic physics. This interplay is about to become even more important as we enter a new era of high‐resolution X‐ray astrophysics with large effective collection area. Although high‐resolution observations with the gratings on the Chandra and XMM‐Newton observatories continue to drive new science, upcoming planned and proposed missions will open up new discovery space in the near future that is currently challenging to access: high‐resolution spectroscopy on extended sources, in the Fe K band, and on short time scales. This review summarizes open questions in these areas and the design parameters for the Hitomi, XRISM, Athena, and Arcus observatories. The expected high quality of spectra taken with these observatories puts new constraints on the accuracy of atomic reference data required to take full advantage of the diagnostic potential of these spectra.

Natalie Hell↗

Hubble Space Telescope images and follow-up spectroscopy of the Orion nebula

Recently published HST images of the Orion nebula reveal elephant-trunk structures, an apparent jet of material, and fine-scale structure in the Herbig-Haro object HH2, which is located at the base of an elephant trunk. High-resolution spectroscopy shows that the apparent jet is actually an ionization front seen edge-on. HH2 shows a complex structure in the several stages of ionization observed. There seem to be two velocity systems characterized by a bright central region and an accompanying shell-like emission. These two systems are most likely to be the result of a bow shock and corresponding Mach disk formed from the interaction of a collimated jet and the ambient gas of the nebula.

O'Dell, C. R.↗

Characterization of MgB2 Superconducting Hot Electron Bolometers

Hot-Electron Bolometer (HEB) mixers have proven to be the best tool for high-resolution spectroscopy at the Terahertz frequencies. However, the current state of the art NbN mixers suffer from a small intermediate frequency (IF) bandwidth as well as a low operating temperature. MgB2 is a promising material for HEB mixer technology in view of its high critical temperature and fast thermal relaxation allowing for a large IF bandwidth. In this work, we have fabricated and characterized thin-film (approximately 15 nanometers) MgB2-based spiral antenna-coupled HEB mixers on SiC substrate. We achieved the IF bandwidth greater than 8 gigahertz at 25 degrees Kelvin and the device noise temperature less than 4000 degrees Kelvin at 9 degrees Kelvin using a 600 gigahertz source. Using temperature dependencies of the radiation power dissipated in the device we have identified the optical loss in the integrated microantenna responsible as a cause of the limited sensitivity of the current mixer devices. From the analysis of the current-voltage (IV) characteristics, we have derived the effective thermal conductance of the mixer device and estimated the required local oscillator power in an optimized device to be approximately 1 microwatts.

Superconducting Devices↗

A variable magnetic disc wind in the black hole X-ray binary GRS 1915+105?

Context. GRS 1915+105 being one of the brightest transient black hole binaries (BHBs) in the X-rays offers a unique testbed for the study of the connection between accretion and ejection mechanisms in BHBs. In particular, this source can be used to study the accretion disc wind and its dependence on the state changes in BHBs. Aims. Our aim is to investigate the origin and geometry of the accretion disc wind in GRS 1915+105. This study will provide a basis for planning future observations with the X-ray Imaging Spectroscopy Mission (XRISM), and may also provide important parameters for estimating the polarimetric signal with the upcoming Imaging X-ray Polarimetry Explorer (IXPE). Methods. We analysed the spectra of GRS 1915+105 in the soft ϕ and hard χ classes using the high-resolution spectroscopy offered by Chandra HETGS. In the soft state, we find a series of wind absorption lines that follow a non-linear dependence of velocity width, velocity shift, and equivalent width with respect to ionisation, indicating a multiple component or stratified outflow. In the hard state we find only a faint Fe XXVI absorption line. We model the absorption lines in both the states using a dedicated magneto-hydrodynamic (MHD) wind model to investigate a magnetic origin of the wind and to probe the cause of variability in the observed line flux between the two states. Conclusions. The MHD disc wind model provides a good fit for both states, indicating the possibility of a magnetic origin of the wind. The multiple ionisation components of the wind are well characterised as a stratification of the same magnetic outflow. We find that the observed variability in the line flux between soft and hard states cannot be explained by photo-ionisation alone but is most likely due to a large (three orders of magnitude) increase in the wind density. We find the mass outflow rate of the wind to be comparable to the accretion rate, suggesting an intimate link between accretion and ejection processes that lead to state changes in BHBs.

A. Ratheesh↗

The Lynx X-Ray Observatory: Concept Study Overview and Status

Lynx, one of four strategic mission concepts under study for the 2020 Astrophysics Decadal Survey, will provide leaps in capability over previous and planned X-ray missions, and will provide synergistic observations in the 2030s to a multitude of space- and ground-based observatories across all wavelengths. Lynx will have orders of magnitude improvement in sensitivity, on-axis sub-arcsecond imaging with arcsecond angular resolution over a large field of view, and high-resolution spectroscopy for point-like and extended sources. The Lynx architecture enables a broad range of unique and compelling science, to be carried out mainly through a General Observer Program. This Program is envisioned to include detecting the very first supermassive black holes, revealing the high-energy drivers of galaxy and structure formation, characterizing the mechanisms that govern stellar activity - including effects on planet habitability, and exploring the highest redshift galaxy clusters. An overview and status of the Lynx concept are summarized.

Gaskin, Jessica A.↗

Filtered Rayleigh scattering measurements in supersonic/hypersonic facilities

Preliminary measurements are presented of flow field properties in Mach 3 and Mach 5 flows using filtered Rayleigh scattering. Filter properties have been characterized by high resolution spectroscopy in order to optimize the selection of laser frequency and filter operating conditions, as well as for the development of an accurate filter modeling program. An optimized filter is used the background suppression feature of this technique to image the boundary layer structure in a Mach 3 high Reynolds number facility and the shock structure in a Mach 5 overexpanded jet. This had been achieved using a visible laser source. By frequency scanning the laser, time-averaged velocity measurements in the Mach 3 and Mach 5 flows are made. Data acquisition at 10 torr and below indicates that this approach can be extrapolated for use in hypersonic flow facilities and is applicable as an in-flight optical air data device for hypersonic vehicles.

Miles, Richard B.↗

Early Spectral Evolution of Classical Novae: Consistent Evidence for Multiple Distinct Outflows

The physical mechanism driving mass ejection during a nova eruption is still poorly understood. Possibilities include ejection in a single ballistic event, a common-envelope interaction, a continuous wind, or some combination of these processes. Here, we present a study of 12 Galactic novae, for which we have premaximum high-resolution spectroscopy. All 12 novae show the same spectral evolution. Before optical peak, they show a slow P Cygni component. After peak, a fast component quickly arises, while the slow absorption remains superimposed on top of it, implying the presence of at least two physically distinct flows. For novae with high-cadence monitoring, a third, intermediate-velocity component is also observed. These observations are consistent with a scenario where the slow component is associated with the initial ejection of the accreted material and the fast component with a radiation-driven wind from the white dwarf. When these flows interact, the slow flow is swept up by the fast flow, producing the intermediate component. These colliding flows may produce theγ-ray emission observed in some novae. Our spectra also show that the transient heavy-element absorption lines seen in some novae have the same velocity structure and evolution as the other lines in the spectrum, implying an association with the nova ejecta rather than a preexisting circumbinary reservoir of gas or material ablated from the secondary. While this basic scenario appears to qualitatively reproduce multiwavelength observations of classical novae, substantial theoretical and observational work is still needed to untangle the rich diversity of nova properties.

E. Aydi↗

Lynx X-Ray Observatory: An Overview

Lynx, one of the four strategic mission concepts under study for the 2020 Astrophysics Decadal Survey, provides leaps in capability over previous and planned x-ray missions and provides synergistic observations in the 2030s to a multitude of space- and ground-based observatories across all wavelengths. Lynx provides orders of magnitude improvement in sensitivity, on-axis subarcsecond imaging with arcsecond angular resolution over a large field of view, and high-resolution spectroscopy for point-like and extended sources in the 0.2- to 10-keV range. The Lynx architecture enables a broad range of unique and compelling science to be carried out mainly through a General Observer Program. This program is envisioned to include detecting the very first seed black holes, revealing the high-energy drivers of galaxy formation and evolution, and characterizing the mechanisms that govern stellar evolution and stellar ecosystems. The Lynx optics and science instruments are carefully designed to optimize the science capability and, when combined, form an exciting architecture that utilizes relatively mature technologies for a cost that is compatible with the projected NASA Astrophysics budget.

X-Ray Surveyor↗

Ultraviolet spectroscopy of comae

Vacuum ultraviolet observations from sounding rockets and satellite observatories of the gaseous comae of several recent comets are reviewed. The earliest of these led to discovery of the hydrogen envelope extending for millions of km from the nucleus. Subsequent observations of H I Lyman alpha, the OH (0,0) band and the oxygen resonance triplet have provided strong evidence for the water-ice model of the cometary nucleus. Several new species were discovered in the coma, including C, C(+), CO, S and CS. High-resolution spectroscopy and the spatial variation of the observed emissions provide means to elucidate the production and excitation mechanisms of these species. The similarity of the spectra of the half-dozen comets observed to date argues for a common, homogeneous composition (with the exception of dust and CO) of the cometary ice and a minimal effect on the neutral species due to molecular collisions in the inner coma.

Feldman, P. D.↗

New Techniques for the Next Far Ultraviolet Spectroscopic Mission

The Far Ultraviolet Spectroscopic Explorer (FUSE) has been a great success, and has addressed many critical scientific questions (Moos, et al, 2000). However, it has also highlighted the need for even more powerful instrumentation in the 900- 1200 A, regime. In particular, significantly increased effective area will permit the pursuit of additional scientific programs currently impractical or impossible with FUSE. It is unlikely that FUSE will last more than a few more years. Nor is it likely that any large scale UV-optical follow-on to HST (such as SUVO) will include the 900-1200 A, bandpass. However, FUSE remains well oversubscribed and continues to perform excellent science. Therefore, a MIDEX class mission in the next 4-6 years that could significantly improve on the FUSE capabilities would be a powerful scientific tool that would be of great utility to the astronomical community. It would open up new scientific programs if it can improve on the sensitivity of FUSE by an order of magnitude. We have identified a powerful technique for efficient, high-resolution spectroscopy in the FUV (and possibly the EUV) that may provide exactly what is needed for such a mission To achieve a factor of 10 improvement in effective area, we propose using a large (meter class), low-cost, grazing incidence metal optics. This would produced in a manner similar to the EUVE mirrors (Green, et al, 1986), using diamond turning to create the optical figure followed by uncontrolled polishing to achieve a high quality surface. This process will introduce significant figure errors that will degrade the image quality. However, if a holographic grating is employed, which has utilized the actual telescope in the recording geometry, all wavefront errors will be automatically corrected in the end-to-end spectrometer, and high quality spectroscopy will be possible with low quality (and low-cost) optics. In this way a MIDEX class FUSE can be proposed with 10 times the effective area of the current instrument.

Green, James C.↗

AXSIO and the NASA X-ray Mission Concept Study

The Advanced X-ray Spectroscopy and Imaging Observatory (AXSIO) focuses on the IXO science objectives ranked highly by the Decadal Survey: tracing orbits near 5MBH event horizons, measuring BH spin, characterizing outflows and the environment of AGN, observing 5MBH to z=6, mapping gas motion in clusters, finding the missing baryons, and observing cosmic feedback. AXSIO's streamlining of IXO includes reduction in the instrument complement to a calorimeter and a grating spectrometer, and relaxation of the angular resolution to 10". With 0.9 m2 effective area at 1.25 keV, AXSIO delivers a 30-fold performance increase over current missions for high-resolution spectroscopy and spectroscopic timing. NASA has also undertaken a study of notional missions to determine lower cost approaches to accomplishing IXO objectives over the next decade. Three concepts were studied; which as a group encompass the full range of IXO science. The capabilities and architecture of these missions are summarized.

Petre, Robert↗

Detection of O2 dayglow emission from Mars and the Martian ozone abundance

High-resolution spectroscopy of Mars in the vicinity of 1.27 microns has revealed the presence of emission lines of O2 which are interpreted as the result of production of O2(1 delta g) in the ultraviolet photolysis of Martian ozone. In the equatorial region of Mars, the dayglow intensity implies an ozone abundance near 0.2 microatm, which seems consistent with theoretical models which utilize the measured water-vapor abundance. A much larger ozone abundance exists in the atmosphere at high winter latitude, in agreement with direct measurement of ozone absorption performed by the Mariner spacecraft.

Noxon, J. F.↗

MEMS-Based Force-Detected Nuclear Magnetic Resonance (FDNMR) Spectrometer

Nuclear Magnetic Resonance (NMR) spectroscopy allows assignment of molecular structure by acquiring the energy spectrum of nuclear spins in a molecule, and by interpreting the symmetry and positions of resonance lines in the spectrum. As such, NMR has become one of the most versatile and ubiquitous spectroscopic methods. Despite these tremendous successes, NMR experiments suffer from inherent low sensitivity due to the relatively low energy of photons in the radio frequency (rt) region of the electromagnetic spectrum. Here, we describe a high-resolution spectroscopy in samples with diameters in the micron range and below. We have reported design and fabrication of force-detected nuclear magnetic resonance (FDNMR).

force detected nuclear magnetic resonance (FDNMR)↗

Anti-Stokes scattering as an XUV radiation source

Harris (1977) has shown that laser induced scattering from atoms stored in a metastable level may be used to produce an XUV radiation source with several unique properties, including narrow linewidth, tunability, linear polarization, picosecond pulsewidth, and relatively high peak spectral brightness. The present investigation provides a summary concerning the progress made on the use of this radiation source as a unique instrument for XUV spectroscopy, and as a possible flashlamp for a 200 A laser. Zych et al. (1978) demonstrated that the maximum spectral brightness of the source is that of a blackbody with a temperature of the metastable storage level. The peak count rate and peak spectral brightness of the anti-Stokes emission at 569 A are 17 times and 139 times greater than those of the 584 A resonance line. The anti-Stokes process was employed as an external source of radiation for high resolution spectroscopy of the 3p6 shell of potassium. Attention is also given to emission spectroscopy of lithium, metastable levels which are appropriate for storage, and a hollow cathode discharge.

Harris, S. E.↗

New two-dimensional photon camera

A photon-sensitive camera, applicable to speckle imaging of astronomical sources, high-resolution spectroscopy of faint galaxies in a crossed-dispersion spectrograph, or narrow-band direct imaging of galaxies, is presented. The camera is shown to supply 8-bit by 8-bit photon positions (256 x 256 pixels) for as many as 10 to the 6th photons/sec with a maximum linear resolution of approximately 10 microns. The sequence of photon positions is recorded digitally with a VHS-format video tape recorder or formed into an immediate image via a microcomputer. The four basic elements of the camera are described in detail: a high-gain image intensifier with fast-decay output phosphor, a glass-prism optical-beam splitter, a set of Gray-coded masks, and a photomultiplier tube for each mask. The characteristics of the camera are compared to those of other photon cameras.

Papaliolios, C.↗