Search NASA⌕ Search

SEARCH · Search NASA

Results for “IM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

RatXcan: A framework for cross-species integration of genome-wide association and gene expression data

Genome-wide association studies (GWAS) have implicated specific alleles and genes as risk factors for numerous complex traits. However, translating GWAS results into biologically and therapeutically meaningful discoveries remains extremely challenging. Most GWAS results identify noncoding regions of the genome, suggesting that differences in gene regulation are the major driver of trait variability. To better integrate GWAS results with gene regulatory polymorphisms, we previously developed PrediXcan (also known as “transcriptome-wide association studies” orTWAS), which maps SNPs to predicted gene expression using GWAS data. In this study, we developed RatXcan, a framework that extends this methodology to outbred heterogeneous stock (HS) rats. RatXcan accounts for the close familial relationships among HS rats by modeling the relatedness with a random effect that encodes the genetic relatedness. RatXcan also corrects for polygenic-driven inflation because of the equivalence between a relatedness random effect and the infinitesimal polygenic model. To develop RatXcan, we trained transcript predictors for 8,934 genes using reference genotype and expression data from five rat brain regions. We found that the cis genetic architecture of gene expression in both rats and humans was sparse and similar across brain tissues. We tested the association between predicted expression in rats and two example traits (body length and BMI) using phenotype and genotype data from 5,401 densely genotyped HS rats and identified a significant enrichment between the genes associated with rat and human body length and BMI. Thus, RatXcan represents a valuable tool for identifying the relationship between gene expression and phenotypes across species and paves the way to explore shared biological mechanisms of complex traits.

Genetics & Heredity↗

Honda Smart Home - Davis, CA

The Honda Smart Home demonstrates zero-carbon living and transportation capacity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Subsurface Energy Systems Mapping Inquiry Tool (MapIT)

The Subsurface Energy Systems Mapping Inquiry Tool (MapIT) is an online web mapping tool designed to help users discover available public-sourced data to facilitate data exploration for subsurface energy exploration and characterization efforts for resource identification (e.g. critical minerals, hydrocarbons, geothermal) as well as injection of geologic sequestration of carbon dioxide (e.g. enhanced oil recovery, saline storage, etc.). Modules within the tool curate data related to geology, faults, fractures, injection and confining zones, hydrologic information, groundwater, groundwater wells, geomechanical and petrophysical data, and geochemical data. User documentation on how to use the tool is also provided. Data have been collected from authoritative national, state, and local sources and made available in this tool. The data is also available as a data catalog and Esri Geodatabase at: https://edx.netl.doe.gov/dataset/mapit-database Disclaimer: There is no guarantee of completeness or appropriateness for individual user’s requirements. Use of this tool is solely at the discretion of the user. See full Federal Disclaimer for further information (https://netl.doe.gov/home/disclaimer). This project was funded by the United States Department of Energy, National Energy Technology Laboratory, in part, through a site support contract. Neither the United States Government nor any agency thereof, nor any of their employees, nor the support contractor, nor any of their employees, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness of any information, apparatus, product, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. https://www.netl.doe.gov/home/disclaimer

Carbon Sequestration↗

WELLS Interactive Application

The Wellbore Exploration and Location Logistic System (WELLS) Interactive Application is an interactive tool to enable easy exploration and visualization of the living national wellbore database (WELLS Database (https://edx.netl.doe.gov/dataset/wells_database)). The tool and underlying database were created and are maintained by the National Energy Technology Laboratory (NETL), providing visualization of the more than six million public wellbore records from more than 65 authoritative state, federal, and tribal resources. The WELLS Interactive Application serves up wellbore data from oil, gas, underground injection, research, geothermal, geotechnical, groundwater, and other types of wells in a single, standardized, unified system. In addition to the surface location of these wells, the underlying database combines select key attributes for features such as well age, depth, and operating status. The system also provides users with references back to the original sources used in this unified platform. The underlying data can be accessed through the WELLS Database: https://edx.netl.doe.gov/dataset/wells_database Additional Information: The WELLS Interactive Application (formerly titled CO2-Locate) enables visualization and access to the public wellbore records through an intuitive web-based mapping tool. The WELLS Interactive Application was designed to help users visualize, query, analyze, and download wellbore records. Public wellbore points are included as a layer in the Map page, called Public Wells. Additionally, a multivariate hexagon grid summarizing well density from proprietary well data, called Well Density, is included to identify data gaps between the public and proprietary well data. Filtering functionalities in the tool allow these two layers to be spatially filtered by state, county, or basin as well as by status, type, true vertical depth, and spud year. The WELLS Interactive Application also contains a Near Me tool can be used to search and explore wellbore data within a user-defined distance of a specified location on the map, which can also be downloaded. The Query tool allows users to query the selected or filtered wells in the Public Wells layer and export the data. For additional information on these tool functionalities, see the help documentation on the About page of the tool. Notes for Consideration: The Well Density layer provided in this application is derived from proprietary wellbore data, the records of which do not always contain values for key features (status, type, true vertical depth, or spud year). Therefore, data might not be available when layers are queried for all filter combinations. Additionally, visualizing layers and applying filters may take additional time to load (i.e., draw on the map) due to the large size of the data.

ccs↗

Geoanalytical Evaluation of Saline Storage (GEESS) Geodatabase v2.0

The Geoanalytical Economic Evaluation of Saline Storage (GEESS) geodatabase was developed to support the United States Department of Energy (DOE) and National Energy Technology Laboratory (NETL) in their geologic carbon storage efforts by characterizing saline geologic formations present in the FECM/NETL CO2 Saline Storage Cost Model (CO2_S_COM) [1]. Using publicly available literature and data, the GEESS geodatabase characterizes 57 geologic formations across the lower-48 U.S. states in what are called Fully Integrated Geodatabases (FIGs). The FIG is a vector polygon feature containing thousands or tens of thousands of individual polygons, which each contain discrete geologic parameter values. A list of the critical geologic parameters that are characterized in the GEESS geodatabase are described in the “Processing Steps and Workflow” part of the ReadMe file, as well as the Data Catalog accompanying the GEESS geodatabase. The FIG is the basis of the GEESS geodatabase and is the direct representation of the collected geologic data. In addition to the FIG, the GEESS system contains grid files. Due to the complexity of the FIGs, grids are used to sample the geologic data so they can be exercised within CO2_S_COM. The grid files contain the geologic data sampled from the FIG, as well as estimates of “Plume Uncertainty Diameter” and “First-year Break-even Price of CO2” derived from CO2_S_COM based on the GEESS grid data.

carbon↗

Automated analysis of unlabeled PV data with Solar Data Tools software: Overview and feature updates

Distributed rooftop PV systems: ubiquitous, yet commonly have unlabeled data Difficult or impossible to form a performance index We developed Solar Data Tools (SDT), an open-source Python library for analyzing PV power (and irradiance) time-series data SDT enables analysis of unlabeled PV data—no model, no meteorological data, no performance index required Takes a statistical signal processing approach Data processing steps are largely pre-defined and automatic regardless of system type—from utility tracking systems to multi-pitch rooftop systems

Meyers-Im, Bennet E↗

Late-Stage Research Development and Demonstration Sub-activities Updates – FY24 Q3

Oak Ridge National Laboratory (ORNL), in collaboration with the Pacific Northwest National Laboratory (PNNL), the National Renewable Energy Laboratory (NREL), the Lawrence Berkeley National Laboratory (LBNL), and the Hummingbird Firm (a specialized consulting firm focused on promoting diversity, equity, and inclusion considerations), has initiated a national initiative known as the Heat Pump (HP) and Heat Pump Water Heater (HPWH) Field Validation Partnership. This effort involves active participation from numerous critical entities involved in research and market transformation within the field. The ORNL team is responsible for leading Late-Stage Research Development and Demonstration (LSRDD) among the four different topics. The overall outcomes of this project will be: (1) A structured Field Validation Partnership between DOE, the national labs, research, implementation, and market transformation organizations. This will result in unique way to coordinate field validation plans and collect relevant data from around the country into the HP and HPWH Field Validation Database. (2) The Field Validation Partnership will result in a continuous stream of information between DOE and the major industry players in the space of HPs and HPWHs. If desired, DOE could use this information to inform roadmaps related to HP and HPWH market adoption and research going forward. (3) The structure of this Partnership provides a mechanism for sharing lessons learned directly between Late-Stage RD&D, Building Integration Barriers, Regional Market and Policy and Workforce Development efforts. The result will be training content that is well-reviewed by the Partnership which will lead to a workforce that meets the industry’s quality and workforce supply demands. (4) The structure of this Partnership also provides an opportunity for regions to share lessons learned on policy and market transformation with each other through the Market and Policy core Committee. This report includes an update in Late-Stage Research Development and Demonstration.

99 GENERAL AND MISCELLANEOUS↗

Design And Control of Thermal Storage for Ventilative Cooling in Multifamily Buildings (Final Report)

The concept of natural ventilation is to provide a heat sink for cooling the building during the occupancy periods at night and improve indoor thermal comfort during the daytime without or with minimal need for mechanical cooling. Commonly, natural ventilation through the window or mechanical circulation of the air through the ventilation ducts are two key methods used to achieve night ventilation. Due to the increasing electric need for space heating and cooling, renewable energies combined with energy storage systems are receiving attention worldwide nowadays. When designed and controlled properly, this strategy can reduce energy use for cooling, reduce the size of mechanical cooling equipment, reduce peak electrical demand for cooling, and better enable demand flexibility for mechanical cooling equipment. In some cases, ventilative cooling can eliminate the need for mechanical cooling altogether. For these reasons, California’s Building Energy Efficiency Standards have recently added prescriptive requirements that all new single-family residences (in most California climates) must include ventilative cooling systems (aka: “whole house fans”). However, the current standards do not address multifamily buildings because market-available ventilative cooling products are designed for single-family residences and are physically incompatible with many multifamily building archetypes. The results from the study show that the combination of thermal energy storage on building walls along with nighttime ventilation cooling assisted with nighttime ventilation can save total building energy usage by up to 9% and peak load by 16% in moderate climate zones. The controlled nighttime ventilation cooling (activate ventilation only when outdoor conditions are favorable) can also provide total electricity savings of up to 5% and 7% in hot and cold climates, respectively. In the case of moderate climates, kitchen exhaust-assisted nighttime ventilation cooling can eliminate the need for cooling during overnight hours. This can also significantly assist in reducing carbon emissions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2023

The objective of this work was to determine the realization rate of energy and cost savings from the U.S. Department of Energy’s (DOE’s) Energy Savings Performance Contract (ESPC) program based on information reported by the energy services companies (ESCOs) that are carrying out ESPC projects at federal sites. Information was extracted from 201 measurement and verification (M&V) reports covering 191 projects to determine reported, estimated, and guaranteed cost savings and the associated reported and estimated energy savings for the previous contract performance year. This report covers projects that had a performance year ending in fiscal year 2023, between October 1, 2022 and September 30, 2023, and had an M&V report issued. Additionally, the annual cost to perform M&V was extracted from the individual project Task Order (TO) Schedules.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Fault Dataset Development for VAV Terminal Units: Damper and Airflow Sensor Faults

This report analyzes field data to understand the impact of faults in variable air volume (VAV) terminal units on building indoor conditions and heating, ventilation, and air-conditioning (HVAC) system operations. The Oak Ridge National Laboratory (ORNL) team conducted field tests at the commercial building test facility known as ORNL’s Flexible Research Platform (FRP) building. Two specific faults-damper malfunctions and airflow sensor inaccuracies- were implemented, as these are common faults in VAV terminal units and can significantly impact HVAC system performance by increasing energy consumption, causing occupant discomfort, and raising operational costs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

BTRIC Technical Support for Appalachia: FY 2024 Summary Report on Net Negative Carbon Building Demonstration with AgPod

This report investigates the effects of various concentrations of CO 2 on the photosynthesis and biomass accumulation of crops growing in an AgPod, using kale as the test crop. In the first year of the study, increasing the CO 2 concentration in the AgPod was found to promote higher photosynthetic rates in kale plants up to 1,300 ppm (the highest CO 2 concentration measured). An interesting finding was that net photosynthetic rates of kale leaves remain unsaturated until reaching unusually high levels of photosynthetically active radiation (PAR, > 1,200 µmol m -1 s -1 ) and CO 2 concentration (> 1,100 ppm). Such high levels of saturating PAR and CO 2 concentration values rarely occur under natural conditions, suggesting a promising potential for carbon capture via enriched controlled environment agriculture (ECEA). During the second year of the study, a second crop was planted to confirm the actual effects on growth with increased CO 2 concentrations. Our results suggest that growing kale plants in the AgPod system at higher CO 2 levels resulted in a successful and highly productive crop, up to three times the amount grown at 415 CO 2 . Further, the kale plants grown under higher CO 2 conditions (1000 ppm) are not CO 2 saturated and can potentially further improve yield at even higher CO 2 environments.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

Among 32 million multi-family buildings in the United States, approximately 42% have poor or no insulation. Envelope retrofits of these buildings will provide thermal resiliency and enable a pathway to electrification of space heating systems as a result of improved thermal performance. Hydronic Shell (HS) is a technology which combines an insulated retrofit panel with a heating, ventilation and air-conditioning (HVAC) thus enabling both envelope retrofit and space heating electrification. In this study, we used whole building energy simulation to evaluate energy impact of multi-family building retrofit with hydronic shell system. The simulation was performed for four locations of New York, Syracuse, Chicago and Boston. The results from the simulation showed more than 66% cooling energy reduction and more than 88% heating energy reduction from Hydronic Shell retrofit compared to Baseline building in all four locations. This reduction in energy consumption resulted in up to 219 MT reduction in annual CO2 emission. The cost reduction per floor area achieved from HVAC energy consumption reduction using Hydronic Shell retrofit was 0.66 to 0.99 $\$$/ft 2 . The results also showed higher percentage of heating energy reduction comes from the envelope only retrofit and higher percentage of cooling energy reduction comes from the retrofit HVAC system for the four locations under study.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydronic Shell: An Affordable Solution for Multifamily Deep Energy Retrofit

Approximately 42% of multi-family buildings in the United States have do not have insulation as required by the building codes. Envelope retrofits of these buildings are needed to improve their thermal performance, provide thermal resilience, and enable a pathway to electrification of space heating systems. Hydronic shell (HS) is a retrofit technique where a stud wall layer is added to a masonry wall along with a convective coil and a fan coil unit fitted in the façade cavity which can provide both heating and cooling to the space. The HS system serves a dual purpose of 1) retrofitting the building envelope and 2) retrofitting the HVAC system and enabling electrification of space heating. The electrification of space heating is possible from the installation of a combination of hydronic system/fan coil unit system which uses a central heat pump as a source of heating water in the cavity between the existing wall and retrofit insulation layer. This study evaluates the performance of the HS system at varying outdoor conditions mimicked by a climate chamber and hot water supply temperature from a water bath. During the ramp-up period, the indoor chamber temperature could be increased from 66 ºF to 69.5 ºF within an hour using heating water at 120 ºF when the outdoor chamber temperature was at 0 ºF. When the indoor chamber temperature was maintained within a deadband, variation in cavity air temperature was mostly influenced by the duration when water was flowing through the cavity convector. It was seen from the testing that the hydronic system alone without use of fan in the system is able to maintain the space temperature at coldest outdoor condition used in the experiment (0 ºF) even at lowest hot water supply temperature chosen (90 ºF). During the ramp-down period, the fastest decline in temperature took 6.4 hours from temperature to drop from 69.6 ºF to 66 ºF which shows tremendous potential of thermal resilience and peak load shifting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reported Energy and Cost Savings from the DOE ESPC IDIQ Program: FY 2024

Energy Savings Performance Contracts (ESPCs)are a contractual mechanism that allow a federal agency to procure energy savings and facility improvements without upfront capital costs to reduce costs and resiliency. ESPCs are covered under FAR Part 23.2, and 42 USC § 8287. Section 8287(a)(2)(A) of Title 42 of the U.S. Code requires that each energy savings performance contract (ESPC) undergo an annual energy audit, resulting in a separate audit report for every project. The objective of the present report is to compile and analyze all annual ESPC audit reports issued between October 1, 2023, and September 30, 2024, for projects awarded under Generations 1, 2, and 3 of DOE’s ESPC IDIQ contracts. During this period, 205 measurement and verification (M&V) reports were produced for 200 projects; the total number of reports exceeds the number of projects because some projects generated more than one report(for example, a few projects measure savings twice per year and produce two audit reports annually, each covering a different six-month period). By aggregating the results from these individual audits, the report determines the portfolio-wide realization rate of energy and cost savings for all active ESPC projects awarded under DOE’s IDIQ program. For all 205audit reports, sufficient information was available to compare project-level estimated, reported, and guaranteed cost savings. Reported cost savings accounted for ESCO verified savings per each project’s M&V plan. The total reported cost savings for the period addressed were $\$$647.8million,compared with the total guaranteed cost savings of $\$$601.6million. On average across the reported projects: •ESPC contractors guaranteed 92.8% of the estimated cost savings• projects reported achieving 100.0% of the estimated cost savings• projects reported achieving 107.7% of the guaranteed cost savings. The M&V performed for the period indicated adjustments for government operations and maintenance impacts to savings amount to$\$$43.9millionandcould be restored with the original operational parameters for impacted projects. Accounting for this potential cost savings impact, these projects still realized 100.4% of the guaranteed cost savings. The information on estimated and reported energy savings was collected and compared for all 205of the reports examined. Based on site energy, estimated savings totaled 14.88million MMBtu, and reported savings were 15.33million MMBtu; 3.1% greater than the estimated energy savings. All of the reports examined contained sufficient information to calculate source energy savings. Based on site-adjusted source energy, total estimated energy savings were 20.90 million MMBtu, and reported savings were 21.22million MMBtu, 101.5% of the estimated energy savings. For water savings, the estimated savings were 11,539,055 kGal and the reported savings were 13,315,930 kGal. This means 1,776,875 kGal more water was saved than estimated, which is about 15% higher than the estimate. These results indicate that, overall, the reported energy savings slightly exceeded the estimated values, while estimated water savings significantly exceeded estimated values, suggesting that the projects achieved greater cost savings than originally projected. The total annual expense for the ESCOs to perform annual M&V audits and reporting was $\$$10.02million. Through this effort, $\$$647.8 million in annual cost savings was verified. The M&V results indicated that $\$$43.9 million of these verified savings reflected adjustments due to government operations A-6and maintenance impacts, which could be restored under the original operational parameters for the affected projects. These findings show the value of M&V that only costs 1.7%of the guaranteed cost savings to ensure guarantees are met.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗