Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMAGING TECHNIQUE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Limited-angle computed tomography with deep image and physics priors

Computed tomography is a well-established x-ray imaging technique to reconstruct the three-dimensional structure of objects. It has been used extensively in a variety of fields, from diagnostic imaging to materials and biological sciences. One major challenge in some applications, such as in electron or x-ray tomography systems, is that the projections cannot be gathered over all the angles due to the sample holder setup or shape of the sample. This results in an ill-posed problem called the limited angle reconstruction problem. Typical image reconstruction in this setup leads to distortion and artifacts, thereby hindering a quantitative evaluation of the results. To address this challenge, we use a generative model to effectively constrain the solution of a physics-based approach. Our approach is self-training that can iteratively learn the nonlinear mapping from partial projections to the scanned object. Because our approach combines the data likelihood and image prior terms into a single deep network, it is computationally tractable and improves performance through an end-to-end training. We also complement our approach with total-variation regularization to handle high-frequency noise in reconstructions and implement a solver based on alternating direction method of multipliers. We present numerical results for various degrees of missing angle range and noise levels, which demonstrate the effectiveness of the proposed approach.

47 OTHER INSTRUMENTATION↗

Sizes of pure and doped helium droplets from single shot x-ray imaging

Advancements in x-ray free-electron lasers on producing ultrashort, ultrabright, and coherent x-ray pulses enable single-shot imaging of fragile nanostructures, such as superfluid helium droplets. Furthermore, this imaging technique gives unique access to the sizes and shapes of individual droplets. In the past, such droplet characteristics have only been indirectly inferred by ensemble averaging techniques. Here, we report on the size distributions of both pure and doped droplets collected from single-shot x-ray imaging and produced from the free-jet expansion of helium through a 5 μm diameter nozzle at 20 bars and nozzle temperatures ranging from 4.2 to 9 K. This work extends the measurement of large helium nanodroplets containing 10 9 –10 11 atoms, which are shown to follow an exponential size distribution. Additionally, we demonstrate that the size distributions of the doped droplets follow those of the pure droplets at the same stagnation condition but with smaller average sizes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Predicting ptychography probe positions using single-shot phase retrieval neural network

Ptychography is a powerful imaging technique that is used in a variety of fields, including materials science, biology, and nanotechnology. However, the accuracy of the reconstructed ptychography image is highly dependent on the accuracy of the recorded probe positions which often contain errors. These errors are typically corrected jointly with phase retrieval through numerical optimization approaches. When the error accumulates along the scan path or when the error magnitude is large, these approaches may not converge with satisfactory result. We propose a fundamentally new approach for ptychography probe position prediction for data with large position errors, where a neural network is used to make single-shot phase retrieval on individual diffraction patterns, yielding the object image at each scan point. The pairwise offsets among these images are then found using a robust image registration method, and the results are combined to yield the complete scan path by constructing and solving a linear equation. We show that our method can achieve good position prediction accuracy for data with large and accumulating errors on the order of 10 2 pixels, a magnitude that often makes optimization-based algorithms fail to converge. For ptychography instruments without sophisticated position control equipment such as interferometers, our method is of significant practical potential.

47 OTHER INSTRUMENTATION↗

Geophysical Signatures of Crack Network Coalescence in Rocks at Multiple Length Scales

The main goal of the research project was to identify the geophysical signatures of fracture growth in natural rocks by utilizing novel geophysical techniques. The research objectives were to (a) investigate the potential for geophysical methods to determine when cracks initiate, the types and locations of propagated cracks, and the coalescence of networks of cracks in natural rocks at multiple scales, (b) determine how damage at the microscale evolved into damage at the macroscale and then link the microscopic and macroscopic observations, (c) quantify crack coalescence in rocks under realistic stress conditions using coupled mechanical-geophysical-optical visualization, and (d) identify the precursors in geophysical signals to crack coalescence. The following research thrusts were explored to achieve the research objectives: (1) uniaxial compression testing of rock specimens with and without a set of pre‐existing flaws and (2) triaxial compression testing of natural rock specimens. These thrusts allowed for exploring fracturing in rocks under realistic in situ environments and at multiple scales. This project provided educational opportunities for nine graduate and undergraduate students and resulted in 27 peer-reviewed publications. This first research thrust focused on investigating the micromechanics of fractures in rocks through uniaxial compression testing combined with advanced geophysical and imaging techniques, specifically acoustic emission (AE) monitoring, ultrasonic imaging, and 2-dimensional Digital Image Correlation (2D-DIC). By examining damage processes under time-independent and time-dependent loading conditions, insights into damage localization, crack initiation, and fracturing mechanisms were gained. It was observed that the AE signals and the strain-based measurements directly reflect the state of damage in the rock specimen and could be used to identify the cracking levels, such as the crack initiation (CI) and crack damage (CD), and the mode of deformation. A novel calibration apparatus was developed to enhance the accuracy of AE sensors, allowing for the estimation of key parameters such as magnitude, source dimension, stress drop, and radiated seismic energy associated with the fractures. The findings highlighted significant variations in the temporal evolution of AE source parameters during the primary, secondary, and tertiary stages of creep, identifying tensile cracking as the primary deformation mode. The second research thrust focused on enhancing the understanding of fracturing processes in natural rocks through triaxial compression testing, real-time AE monitoring, and ultrasonic monitoring. We investigated the impact of various factors such as fracture propagation regimes, injection parameters, rock types, and pre-existing conditions on the hydraulic fracture (HF) behavior using scaled true-triaxially loaded specimens of Barre granite and Lyons sandstone. Custom sensor housing facilitated concurrent active and passive monitoring to analyze hydro-mechanical responses and microseismicity associated with different HF scenarios. A coupled investigation of passive microseismicity and active signal attributes permitted a detailed comprehension of the various HF processes (aseismic deformation, fracture initiation and propagation, fluid permeation, and leak-off) and their dependence on the specific rock type. The findings of this research demonstrated the effectiveness of AE monitoring techniques in providing valuable insights into the impact of various factors on the behavior and dynamics of HF processes. The advancements in monitoring techniques, offering a more thorough and precise approach, represent a significant step towards optimizing HF practices and ensuring sustainable resource extraction.

58 GEOSCIENCES↗

Fast widefield imaging of neuronal structure and function with optical sectioning in vivo

Optical microscopy, owing to its noninvasiveness and subcellular resolution, enables in vivo visualization of neuronal structure and function in the physiological context. Optical-sectioning structured illumination microscopy (OS-SIM) is a widefield fluorescence imaging technique that uses structured illumination patterns to encode in-focus structures and optically sections 3D samples. However, its application to in vivo imaging has been limited. In this study, we optimized OS-SIM for in vivo neural imaging. We modified OS-SIM reconstruction algorithms to improve signal-to-noise ratio and correct motion-induced artifacts in live samples. Incorporating an adaptive optics (AO) module to OS-SIM, we found that correcting sample-induced optical aberrations was essential for achieving accurate structural and functional characterizations in vivo. With AO OS-SIM, we demonstrated fast, high-resolution in vivo imaging with optical sectioning for structural imaging of mouse cortical neurons and zebrafish larval motor neurons, and functional imaging of quantal synaptic transmission at Drosophila larval neuromuscular junctions.

42 ENGINEERING↗

Toward inverse backscatter absorption gas imaging: imaging a dry gas plume with ambient H 2 O absorption

This paper introduces inverse backscatter absorption gas imaging (iBAGI), a transparent gas imaging technique based on absorption spectroscopy of gases naturally present in ambient air being displaced by transparent gases. We demonstrate reconstruction of a 2-D image of a dry gas plume by measuring light of a raster-scanned diode laser tuned to an absorption line of atmospheric H 2 O. We quantify the performance depending on the distance to the backdrop and show that the key transmission metric is independent of absorption path length. We conclude with an outlook toward calibration-free, single-ended iBAGI using scattering from low-reflectivity backdrops.

Klug, Joseph C.↗

First-principles simulation of light-ion microscopy of graphene

The extreme sensitivity of 2D materials to defects and nanostructure requires precise imaging techniques to verify presence of desirable and absence of undesirable features in the atomic geometry. Helium-ion beams have emerged as a promising materials imaging tool, achieving up to 20 times higher resolution and 10 times larger depth-of-field than conventional or environmental scanning electron microscopes. Here, we offer first-principles theoretical insights to advance ion-beam imaging of atomically thin materials by performing real-time time-dependent density functional theory simulations of single impacts of 10–200 keV light ions in free-standing graphene. Here we predict that detecting electrons emitted from the back of the material (the side from which the ion exits) would result in up to three times higher signal and up to five times higher contrast images, making 2D materials especially compelling targets for ion-beam microscopy. This predicted superiority of exit-side emission likely arises from anisotropic kinetic emission. The charge induced in the graphene equilibrates on a sub-fs time scale, leading to only slight disturbances in the carbon lattice that are unlikely to damage the atomic structure for any of the beam parameters investigated here.

36 MATERIALS SCIENCE↗

Single-Filament Imaging Mass Spectrometry Lipidomics in Arthrospira platensis

Elucidating intra-organismal biochemical and lipid organization in photosynthetic biological cell factories of filamentous cyanobacteria, i.e., Arthrospira platensis (Spirulina), is important to track physiological response mechanisms during growth. Little is known about the filaments' biochemical organization and cellular structure and no label-free imaging techniques exist that provide molecular mapping. We applied ultra-high resolution mass spectrometry (7T FT-ICR-MS) matrix-assisted laser desorption ionization (MALDI) imaging to immobilized Spirulina filaments to investigate the localization of lipids across distinct physiological regions. We optimized matrix selection and deposition methods with the goal of facilitating high spatial, and intra-filament, resolution using untargeted multivariate statistical spectral deconvolution across MS pixels. Our results demonstrate an improved two step application with an optimized procedure for intra-organismal lipid profiling to improve analyte sensitivity and achieve higher spatial resolution, whereby we evaluate three conventional matrices 2,5-dihydroxybenzoic acid (DHB), a 9:1 ratio of DHB:superDHB (sDHB), 1,5- diaminonaphthalene (DAN) and a 50:50 mix of DHB:sDHB and compare delineation and pixel-based elucidation of intra-filament lipidomics. We identified a total of 1,626 features that could be putatively assigned a lipid-like formula based on database query and 46 unique features, with associated lipid assignments that were significantly distinct in their intra-filament location. MALDI- imaging MS with untargeted statistical spectral deconvolution was used to visualize intra-filament lipidomics organization in Spirulina filaments. Improvements in matrix deposition, including sequential sublimation and pneumatic spraying, increased signal abundance at high spatial resolution and allowed for identification of distinct lipid composition regions. Here in this work outlines a methodology that may be used for micro-ecological untargeted molecular phenotyping.

09 BIOMASS FUELS↗

6 nm super-resolution optical transmission and scattering spectroscopic imaging of carbon nanotubes using a nanometer-scale white light source

Abstract Optical transmission and scattering spectroscopic microscopy at the visible and adjacent wavelengths denote one of the most informative and inclusive characterization methods in material research. Unfortunately, restricted by the diffraction limit of light, it cannot resolve the nanoscale variation in light absorption and scattering, diagnostics of the local inhomogeneity in material structure and properties. Moreover, a large quantity of nanomaterials has anisotropic optical properties that are appealing yet hard to characterize through conventional optical methods. There is an increasing demand to extend the optical hyperspectral imaging into the nanometer length scale. In this work, we report a super-resolution hyperspectral imaging technique that uses a nanoscale white light source generated by superfocusing the light from a tungsten-halogen lamp to simultaneously obtain optical transmission and scattering spectroscopic images. A 6-nm spatial resolution in the visible to near-infrared wavelength regime (415–980 nm) is demonstrated on an individual single-walled carbon nanotube (SW-CNT). Both the longitudinal and transverse optical electronic transitions are measured, and the SW-CNT chiral indices can be identified. The band structure modulation in a SW-CNT through strain engineering is mapped.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sparse-Data Deep Learning Strategies for Radiographic Non-Destructive Testing

Radiography is an imaging technique used in a variety of applications, such as medical diagnosis, airport security, and nondestructive testing. We present a deep learning system for extracting information from radiographic images. We perform various prediction tasks using our system, including material classification and regression on the dimensions of a given object that is being radiographed. Our system is designed to address the sparse-data issue for radiographic nondestructive testing applications. It uses a radiographic simulation tool for synthetic data augmentation, and it uses transfer learning with a pre-trained convolutional neural network model. Using this system, our preliminary results indicate that the object geometry regression task saw an improvement of 70% in the R-squared value when using a multi-regime model. In addition, we increase the performance of the object material classification tasks by utilizing data from different imaging systems. In particular, using neutron imaging improved the material classification accuracy by 20% when compared to x-ray imaging.

convolutional neural networks↗

Confined hyperbolic metasurface modes for structured illumination microscopy

Plasmonic hyperbolic metasurfaces have emerged as an effective platform for manipulating the propagation of light. Here, confined modes on arrays of silver nanoridges that exhibit hyperbolic dispersion are used to demonstrate and model a super-resolution imaging technique based on structured illumination microscopy. A spatial resolution of ∼75 nm at 458 nm is demonstrated, which is 3.1 times better than an equivalent diffraction limited image. This work emphasizes the ability to engineer the properties of confined optical modes and to leverage those characteristics for applications in imaging. The results of this work could lead to improved approaches for super-resolution imaging using designed sub-wavelength structures.

42 ENGINEERING↗

Visualization of shocked material instabilities using a fast-framing camera and XFEL four-pulse train

Many questions regarding dynamic materials could be answered by using time-resolved ultra-fast imaging techniques to characterize the physical and chemical behavior of materials in extreme conditions and their evolution on the nanosecond scale. In this work, we perform multi-frame phase-contrast imaging (PCI) of micro-voids in low density polymers under laser-driven shock compression. At the Matter in Extreme Conditions (MEC) Instrument at the Linac Coherent Light Source (LCLS), we used a train of four x-ray free electron laser (XFEL) pulses to probe the evolution of the samples. To visualize the void and shock wave interaction, here, we deployed the Icarus V2 detector to record up to four XFEL pulses, separated by 1-3 nanoseconds. In this work, we image elastic waves interacting with the micro-voids at a pressure of several GPa. Monitoring how the material’s heterogeneities, like micro-voids, dictate its response to a compressive wave is important for benchmarking the performances of inertial confinement fusion energy materials. For the first time in a single sample, we have combined an ultrafast x-ray framing camera and four XFEL pulse train to create an ultrafast movie of micro-void evolution under laser-driven shock compression. Eventually, we hope this technique will resolve the material density as it evolves dynamically under laser shock compression.

fusion↗

ExoReL{sup R}: A Bayesian Inverse Retrieval Framework for Exoplanetary Reflected Light Spectra

The high-contrast imaging technique is meant to provide insight into those planets orbiting several astronomical units from their host star. Space missions such as Wide-Field InfraRed Survey Telescope, Habitable Exoplanet Imaging Mission, and Large Ultra-Violet/Optical/InfraRed Surveyor will measure reflected light spectra of cold gaseous and rocky planets. To interpret these observations, we introduce ExoReL{sup R} (Exoplanetary Reflected Light Retrieval), a novel Bayesian retrieval framework to retrieve cloud properties and atmospheric structures from exoplanetary reflected light spectra. As a unique feature, it assumes a vertically nonuniform volume mixing ratio (VMR) profile of water and ammonia, and uses it to construct cloud densities. In this way, clouds and molecular mixture ratios are consistent. We apply ExoReL{sup R} on three test cases: two exoplanets (υ And e and 47 Uma b) and Jupiter. We show that we are able to retrieve the concentration of methane in the atmosphere, and estimate the position of clouds when the signal-to-noise ratio of the spectrum is higher than 15, in line with previous works. Moreover, we described the ability of our model to give a chemical identity to clouds, and we discussed whether or not we can observe this difference in the planetary reflection spectrum. Finally, we demonstrate how it could be possible to retrieve molecular concentrations (water and ammonia in this work) below the clouds by linking the nonuniform VMR profile to the cloud presence. This will help to constrain the concentration of water and ammonia unseen in direct measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Atomic-Scale Structural Mapping of Active Sites in Monolayer PGM-Free Catalysts by Low-Voltage 4D-STEM

Two-dimensional (2D) materials have attracted a large amount of attention in both basic and applied fields, and scanning transmission electron microscopy (STEM) is often uniquely well-suited for characterizing the atomic-scale structure of these materials [1-4]. As a result, STEM is poised to significantly impact progress on platinum group metal (PGM)-free catalysts, which are currently under intense development to enable low-cost, commercially viable hydrogen fuel cells [5]. While recent advancements have resulted in fuel cell performance comparable to Pt catalysts by some measures [6], cell durability remains a significant challenge, limiting practical applications [7]. Catalytically active sites in PGM-free materials are proposed to be FeN4 complexes embedded in a graphene lattice (Fig. 1b) within layered or other larger materials, but this is still under debate largely due to the range of potential actives sites predicted by computational methods and lack of methods for directly validating these models [5]. Fundamental insights into the atomic structure and resulting degradation pathways of proposed active sites are therefore needed to fully understand and control cell performance and durability [6].2D materials typically make ideal samples for STEM, but those within PGM-free catalysts present additional challenges since these materials are often defect-rich, with a high density of edges, dopant atoms, etc., which significantly increase susceptibility to beam damage at standard operating voltages. This makes analysis of potential FeN4 active sites particularly challenging, since a large proportion of Fe exists at edge sites where beam-induced atomic displacements can prohibit high-resolution structural characterization [6]. Conventional dark-field imaging compounds this problem by producing less signal for a given dose and being less sensitive to light elements than dose-efficient phase contrast imaging techniques such as those enabled by four-dimensional (4D)-STEM [8-10] (Fig. 1a). Consequently, active site structural analysis is often left to methods such as low-resolution imaging combined with quantum chemical calculations [6], which hinders accurate determination of reaction and degradation mechanisms.Here, we demonstrate direct atomic-scale structural mapping of FeN4 sites by performing low-voltage 4D-STEM on a model PGM-free catalyst system with many exposed monolayer regions. To accomplish this, we pair a 30 keV aberration-corrected probe with a fast pixelated detector that has optimal performance at low beam voltages [11]. This enables us to simultaneously image light and heavy elements with high signal-to-noise by center-of-mass analysis (Fig. 1c) while minimizing beam-induced atomic displacements at sensitive sites. The monolayer nature of these materials additionally allows for experimental validation by direct comparison with multislice simulations [12] of model structures (Fig. 1d-e). This work demonstrates how low-voltage 4D-STEM will provide new insights into the atomic-scale structure and degradation mechanisms of active sites in PGM-free catalysts, facilitating the development of low-cost hydrogen fuel cells and other energy conversion technologies in the future [13].

Zachman, Michael↗

Development of a true single line of sight 3D hot-spot imaging for the National Ignition Facility

High resolution 3D self-emission x-ray imaging during inertial confinement fusion capsule implosion enables the measurement of the shape of the hotspot. While current 3D imaging capabilities use multiple lines of sight to perform image reconstruction, it would be highly desirable to use only one line of sight, as this would significantly reduce the number of windows in the target hohlraum and decrease their impacts on implosion symmetry. Such a goal is achievable using the zone plate coded imaging technique developed by N. M. Ceglio [Proc. SPIE 0106, 55-62 (1977)]. It consists of fielding a visible light Fresnel zone plate on shot to record a shadowgraph. Here, the image can then be reconstructed either by printing the shadowgraph on a transparent film and shining a suitable wavelength light through it or by numerical reconstruction. A new approach using numerical reconstruction is presented, and it relaxes the constraint by an order of magnitude on the optic design, thus enabling an easier fabrication process, as it allows a scaling-up of the optic dimensions. The design, fabrication process, and testing with an x-ray source of a prototype is presented. The reconstruction of an ~14.5 × 17 μm 2 broadband x-ray source was successful and shows that the performances are in line with expectation with an at least 5 mm axial resolution.

47 OTHER INSTRUMENTATION↗

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Ultra-compact Imaging Technology (CRADA Final Report)

As part of the Cyclotron Road program, Synopic (formerly FlatCam LLC) sought to investigate the benefits of its depth-sensitive imaging techniques. The basic principle involved using a thin mask specially designed to encode light reaching a sensor, in conjunction with optimized computational algorithms, in such a manner that allowed for both miniaturization of imaging systems and improved computation toward high resolution, three-dimensional imaging. By thoroughly exploring the resolution, mask/optical design, and algorithmic capabilities of our depth sensitive technology, we expand the potential applications for (but not limited to) medical, consumer and industrial purposes. The project aimed to develop new imaging systems by building on previous work and using 1) materials capable of modulating and 2) sensors capable of measuring visible and longer wavelengths. Preliminary research was conducted to design, fabricate and characterize imaging systems with the goal of improving resolution, enhancing single capture, three-dimensional imaging, and extending depth of field of captured images. The primary goal was to determine whether adapting the depth-sensitive imaging system is feasible, and early results are promising.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗