Search NASA⌕ Search

SEARCH · Search NASA

Results for “IMPLANTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Bias in bonding behavior among boron, carbon, and nitrogen atoms in ion implanted a-BN, a-BC, and diamond like carbon films

In this study, we implanted N{sup +} and N{sub 2}{sup +} ions into sputter deposited amorphous boron carbide (a-BC) and diamond like carbon (DLC) thin films in an effort to understand the chemical bonding involved and investigate possible phase separation routes in boron carbon nitride (BCN) films. In addition, we investigated the effect of implanted C{sup +} ions in sputter deposited amorphous boron nitride (a-BN) films. Implanted ion energies for all ion species were set at 40 KeV. Implanted films were then analyzed using x-ray photoelectron spectroscopy (XPS). The changes in the chemical composition and bonding chemistry due to ion-implantation were examined at different depths of the films using sequential ion-beam etching and high resolution XPS analysis cycles. A comparative analysis has been made with the results from sputter deposited BCN films suggesting that implanted nitrogen and carbon atoms behaved very similar to nitrogen and carbon atoms in sputter deposited BCN films. We found that implanted nitrogen atoms would prefer bonding to carbon atoms in the films only if there is no boron atom in the vicinity or after all available boron atoms have been saturated with nitrogen. Implanted carbon atoms also preferred to either bond with available boron atoms or, more likely bonded with other implanted carbon atoms. These results were also supported by ab-initio density functional theory calculations which indicated that carbon-carbon bonds were energetically preferable to carbon-boron and carbon-nitrogen bonds.

36 MATERIALS SCIENCE↗

Effects of nitrogen ion implantation time on tungsten films deposited by DC magnetron sputtering on AISI 410 martensitic stainless steel

Nitrogen ion implantation time on tungsten thin film deposited on surface of AISI 410 steel has been performed. Tungsten thin film produced by dc magnetron sputtering method was deposited on AISI 410 martensitic stainless steel substrates, and then the nitrogen ions were implanted on tungsten thin film. The objective of this research is to investigate the effects of implantation deposition time on surface roughness, microhardness, specific wear and corrosion rate of nitrogen implanted on tungsten film. Magnetron sputtering process was performed by using plasma gas of argon (Ar) to bombardier tungsten target (W) in a vacuum chamber with a pressure of 7.6 x 10{sup −2} torr, a voltage of 300 V, a sputter current of 80 mA for sputtered time of 10 minutes. Nitrogen implantation on tungsten film was done with an initial pressure of 3x10{sup −6} mbar, a fluence of 2 x 10{sup 17} ions/cm{sup 2}, an energy of 100 keV and implantation deposition times of 0, 20, 30 and 40 minutes. The surface roughness, microhardness, specific wear and corrosion rate of the films were evaluated by surfcorder test, Vickers microhardness test, wear test and potentiostat (galvanostat) test respectively. The results show that the nitrogen ions implanted deposition time on tungsten film can modify the surface roughness, microhardness, specific wear and corrosion rate. The minimum surface roughness, specific wear and corrosion rate can be obtained for implantation time of 20 minutes and the maximum microhardness of the film is 329 VHN (Vickers Hardness Number) for implantation time of 30 minutes. The specific wear and corrosion rate of the film depend directly on the surface roughness.

36 MATERIALS SCIENCE↗

Intrauterine exosomes are required for bovine conceptus implantation

Highlights: • Exosomes derived from the conceptuses acted on the endometrial epithelium. • Global protein analysis identified 596 exosomal proteins during peri-implantation. • Exosomes at pre-implantation up-regulated apoptosis-related genes in uterine cells. • Exosomes at post-implantation up-regulated adhesion molecule in uterine cells. Exosomes, extracellular vesicles, are present in uterine flushing fluids (UFs), which are involved in conceptus-endometrial interactions during peri-implantation periods. Despite several studies on intrauterine exosomes conducted, the roles conceptus and endometrial exosomes play during peri-implantation periods have not been well characterized. To investigate the effect of bovine intrauterine exosomes on conceptus implantation, exosomes isolated from bovine UFs during peri-implantation periods were subjected to global protein analysis. The analysis detected 596 exosomal proteins, including ruminants' pregnancy recognition factor IFNT, and 172 differentially expressed proteins with more than 1.5-fold changes in UFs on days 17, 20 and 22 pregnancy (day of conceptus implantation is initiated on days 19–19.5). Treatment of primary bovine endometrial epithelial cells with exosomes from day 17 UFs up-regulated the expression of apoptosis-related genes, and treatment with exosomes from day 20 and 22 UFs up-regulated the expression of adhesion molecule. Based on these findings, intrauterine exosomes should be considered as an essential constituent for successful implantation.

60 APPLIED LIFE SCIENCES↗

Ion implantation of magnesium guests into type II silicon clathrate films: an alternate approach to doping a cage-like silicon allotrope

Type II silicon clathrates, with their unique cage-like structure, offer exciting potential for applications in thermoelectrics, photovoltaics, and quantum materials due to their tunable electronic and thermal properties. This study investigates the use of ion implantation to introduce targeted guest atoms, which act as dopants, into type II Si clathrate films. The focus is on Mg as a test case for implantation, a dopant previously unreported in type II Si clathrates. The effects of ion implantation on the metastable Si clathrate structure were examined through systematic investigation of implant parameters. Time-of-flight secondary ion mass spectrometry depth profiling confirmed the successful implantation of Mg, while X-ray diffraction and confocal Raman spectroscopy demonstrated minimal structural damage at lower fluences, with the clathrate framework retaining its integrity without converting to other phases. At the higher end of the fluence range implantation caused localized transitions from clathrate to amorphous silicon. Implant activation using rapid thermal annealing was examined with the clathrate structure stable up to 500 °C and being converted to diamond silicon above this temperature. Post-implantation and activation structural characterization showed evidence of damage reversal. Electron paramagnetic resonance studies provided indirect evidence of dopant incorporation. These findings establish a foundation for introducing alternative guests/dopants into the Si clathrate cages through ion implantation, advancing their tunability for next-generation quantum and optoelectronic devices.

36 MATERIALS SCIENCE↗

Structural transition and recovery of Ge implanted β -Ga 2 O 3

Ion implantation-induced effects were studied in Ge implanted β-Ga 2 O 3 with the fluence and energy of 3 × 10 13 cm -2 /60 keV, 5 × 10 13 cm -2 /100 keV, and 7 × 10 13 cm -2 /200 keV using analytical electron microscopy via scanning/transmission electron microscopy, electron energy loss spectroscopy, and precession electron diffraction via TopSpin. Imaging shows an isolated band of damage after Ge implantation, which extends ~130 nm from the sample surface and corresponds to the projected range of the ions. Electron diffraction demonstrates that the entirety of the damage band is the κ phase, indicating an implantation-induced phase transition from β to κ-Ga 2 O 3 . Post-implantation annealing at 1150 °C for 60 s under the O 2 atmosphere led to a back transformation of κ to β; however, an ~17 nm damage zone remained at the sample surface. Despite the back transformation from κ to β with annealing, O K-edge spectra show changes in the fine structure between the pristine, implanted, and implanted-annealed samples, and topspin strain analysis shows a change in strain between the two samples. These data indicate differences in the electronic/chemical structure, where the change of the oxygen environment extended beyond the implantation zone (~130 nm) due to the diffusion of Ge into the bulk material, which, in turn, causes a tensile strain of 0.5%. This work provides a foundation for understanding of the effects of ion implantation on defect/phase evolution in β-Ga 2 O 3 and the related recovery mechanism, opening a window toward building a reliable device for targeted applications.

36 MATERIALS SCIENCE↗

Moving Toward Focal Therapy in Prostate Cancer: Dual-Isotope Permanent Seed Implants as a Possible Solution

Purpose: To compare the ability of single- and dual-isotope prostate seed implants to escalate biologically effective dose (BED) to foci of disease while reducing prescription dose to the prostate. Methods and Materials: Nine plans, using {sup 125}I, {sup 103}Pd, and {sup 131}Cs alone and in combination were created retrospectively for 2 patients. Ultrasound and MRI/MRS datasets were used for treatment planning. Voxel-by-voxel BED was calculated for single- and dual-isotope plans. Equivalent uniform BED (EUBED) was used to compare plans. The MRS-positive planning target volumes (PTV{sub i}) were delineated along with PTV (prostate + 5 mm), rectum, and urethra. Single-isotope implants, prescribed to conventional doses, were generated to achieve good PTV coverage. The PTV{sub i} were prospectively used to generate implants using mixtures of isotopes. For mixed-radioisotope implants, we also explored the impact on EUBED of lowering prescription doses by 15%. Results: The EUBED of PTV{sub i} in the setting of primary {sup 125}I implant increased 20-66% when {sup 103}Pd and {sup 131}Cs were used compared with {sup 125}I boost. Decreasing prescription dose by 15% in mixed-isotope implants results in a potential 10% reduction in urethral EUBED with preservation of PTV coverage while still boosting PTV{sub i} (up to 80%). When radiobiologic parameters corresponding to more-aggressive disease are assigned to foci, faster-decaying isotopes used in mixed implants have the potential to preserve the equivalent biological effect of mono-isotope implants considering less-aggressive disease distributed in the entire prostate. Conclusions: This is a hypothesis-generating study proposing a treatment paradigm that could be the middle ground between whole-gland irradiation and focal-only treatment. The use of two isotopes concurrent with decreasing the minimal peripheral dose is shown to increase EUBED of selected subvolumes while preserving the therapeutic effect at the level of the gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nanoscale lattice strains in self-ion implanted tungsten

Developing a comprehensive understanding of the modification of material properties by neutron irradiation is important for the design of future fission and fusion power reactors. Self-ion implantation is commonly used to mimic neutron irradiation damage, however an interesting question concerns the effect of ion energy on the resulting damage structures. The reduction in the thickness of the implanted layer as the implantation energy is reduced results in the significant quandary: Does one attempt to match the primary knock-on atom energy produced during neutron irradiation or implant at a much higher energy, such that a thicker damage layer is produced? In this work, we address this question by measuring the full strain tensor for two ion implantation energies, 2 MeV and 20 MeV in self-ion implanted tungsten, a critical material for the first wall and divertor of fusion reactors. A comparison of 2 MeV and 20 MeV implanted samples is shown to result in similar lattice swelling. Multi-reflection Bragg coherent diffractive imaging (MBCDI) shows that implantation induced strain is in fact heterogeneous at the nanoscale, suggesting that there is a non-uniform distribution of defects, an observation that is not fully captured by micro-beam Laue diffraction. At the surface, MBCDI and high-resolution electron back-scattered diffraction (HR-EBSD) strain measurements agree quite well in terms of this clustering/non-uniformity of the strain distribution. However, MBCDI reveals that the heterogeneity at greater depths in the sample is much larger than at the surface. This combination of techniques provides a powerful method for detailed investigation of the microstructural damage caused by ion bombardment, and more generally of strain related phenomena in micro-volumes that are inaccessible via any other technique.

36 MATERIALS SCIENCE↗

Implantation and Stability of Metallic Fiducials Within Pulmonary Lesions

Purpose: To report and describe implantation techniques and stability of metallic fiducials in lung lesions to be treated with external beam radiotherapy. Methods and Materials: Patients undergoing radiation therapy for small early-stage lung cancer underwent implantation with small metallic markers. Implantation was either transcutaneous under computed tomographic (CT) or fluoroscopic guidance or transbronchial with the superDimension/Bronchus system (radiofrequency signal-based bronchoscopy guidance related to CT images). Results: Implantation was performed transcutaneously in 15 patients and transbronchially in 8 patients. Pneumothorax occurred with eight of the 15 transcutaneous implants, six of which required chest tube placement. None of the patients who underwent transbronchial implantation developed pneumothorax. Successfully inserted markers were all usable during gated image-guided radiotherapy. Marker stability was determined by observing the variation in gross target volume (GTV) centroid relative to the marker on repeated CT scans. Average three-dimensional variation in the GTV center relative to the marker was 2.6 {+-} 1.3 (SD) mm, and the largest variation along any anatomic axis for any patient was <5 mm. Average GTV volume decrease during the observation period was 34% {+-} 23%. Gross tumor volumes do not appear to shrink uniformly about the center of the tumor, but rather the tumor shapes deform substantially throughout treatment. Conclusions: Transbronchial marker placement is less invasive than transcutaneous placement, which is associated with high pneumothorax rates. Although marker geometry can be affected by tumor shrinkage, implanted markers are stable within tumors throughout the treatment duration regardless of implantation method.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Bronchoscopic Implantation of a Novel Wireless Electromagnetic Transponder in the Canine Lung: A Feasibility Study

Purpose: The success of targeted radiation therapy for lung cancer treatment is limited by tumor motion during breathing. A real-time, objective, nonionizing, electromagnetic localization system using implanted electromagnetic transponders has been developed (Beacon electromagnetic transponder, Calypso Medical Technologies, Inc., Seattle, WA). We evaluated the feasibility and fixation of electromagnetic transponders bronchoscopically implanted in small airways of canine lungs and compared to results using gold markers. Methods and Materials: After approval of the Animal Studies Committee, five mongrel dogs were anesthetized, intubated, and ventilated. Three transponders were inserted into the tip of a plastic catheter, passed through the working channel of a flexible bronchoscope, and implanted into small airways of a single lobe using fluoroscopic guidance. This procedure was repeated for three spherical gold markers in the opposite lung. One, 7, 14, 28, and 60 days postimplantation imaging was used to assess implant fixation. Results: Successful bronchoscopic implantation was possible for 15 of 15 transponders and 12 of 15 gold markers; 3 markers were deposited in the pleural space. Fixation at 1 day was 15 of 15 for transponders and 12 of 12 for gold markers. Fixation at 60 days was 6 of 15 for transponders and 7 of 12 for gold markers, p value = 0.45. Conclusions: Bronchoscopic implantation of both transponders and gold markers into the canine lung is feasible, but fixation rates are low. If fixation rates can be improved, implantable electromagnetic transponders may allow improved radiation therapy for lung cancer by providing real-time continuous target tracking. Developmental work is under way to improve the fixation rates and to reduce sensitivity to implantation technique.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Depth Profiling of N and C in Ion Implanted ZnO and Si Using Deuterium Induced Nuclear Reaction Analysis

Nuclear Reaction Analysis (NRA) with deuteron ion beams has been used to probe for ion implanted nitrogen and carbon with high sensitivity in zinc oxide and silicon single crystals. The ion implanted N was measured using 1.4 MeV deuteron ion beams and was found to be in agreement with calculated values. The limit of detection for N in ZnO is 8x10{sup 14} ions cm{sup -2}. Raman measurements of the ion implanted samples showed three additional modes at 275, 504, and 644 cm{sup -1} compared to the un-implanted ZnO crystals. The NRA and Raman results provided information on the N concentration, depth distribution, and structural changes that occur in dependence on the nitrogen ion fluences. The deuterium induced {sup 12}C(d,p){sup 13}C reaction was used to measure the carbon impurity/dose in ion implanted silicon. It was found that the use of a large cold shield (liquid nitrogen trap) in the ion implanter chamber greatly reduces the amount of carbon impurity on the surface of ion implanted silicon. Various implantations with N{sub 2}, O{sub 2}, NO, NO{sub 2} and Pb ions were performed with and without cooling of the liquid nitrogen trap. Simultaneous detection of ppm-level concentrations of {sup 12}C, {sup 16}O and {sup 14}N enables highly sensitive measurement of impurities that may be incorporated during the fabrication process, transport of the samples and/or storage of the samples in air.

36 MATERIALS SCIENCE↗

Structural and cathodoluminescence properties of ZnO nanorods after Ga-implantation and annealing

Single-crystalline ZnO nanorods were implanted with 30 keV Ga{sup +} ions and fluences between 5x10{sup 12} and 1.5x10{sup 16} cm{sup -2}. Annealing treatments at temperatures up to 700 deg. C for 1 h were carried out to reduce implantation-induced structural defects. The structural and optical properties of the nanorods were studied by transmission electron microscopy (TEM) and cathodoluminescence (CL) spectroscopy. TEM shows that extended implantation defects vanish completely in nanorods implanted with doses up to 5x10{sup 13} cm{sup -2} after annealing at 700 deg. C. Dislocation loops remain after implantation with higher fluences. The CL intensity of as-grown nanorods and implanted ZnO nanorods is low. Annealing at 700 deg. C leads to a significant increase in the CL intensity for as-grown nanorods and implanted with a dose of up to 5x10{sup 13} cm{sup -2}. The strong CL intensity in implanted and annealed nanorods correlates with the complete disappearance of extended structural defects.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Properties of nitrogen implanted and electron beam annealed bulk ZnO

The optical properties of bulk ZnO ion implanted with nitrogen ions, at an energy of 23 keV have been studied as a function of implantation fluence and electron beam (EB) annealing conditions. Nuclear reaction analysis and Raman results have revealed the implanted N concentration and its structural changes with respect to various nitrogen ion fluences. The optical properties of nitrogen implanted bulk ZnO were investigated by low temperature photoluminescence measurements. An enhanced peak at 3.235 eV has been attributed to donor-accepter pair (DAP) emission involving the implanted N acceptor in ZnO. The emission near 3.3085 eV is attributed to a free electron to acceptor transition. We also report a broad band emission feature at {approx}3.09 eV in the nitrogen implanted with 1-2x10{sup 15} ions cm{sup -2} and EB annealed at 800-900 deg. C. This is assigned to a thermally activated nitrogen acceptor transition as it is unique only to nitrogen implanted samples. An ionization energy of 377 meV indicates that this line may correspond to a significantly less shallow acceptor level. In addition an increase in the intensity and dominance of this DAP line in nitrogen implanted samples over the other acceptor transitions was observed with increasing annealing time and temperatures. It is shown that EB annealing offers a method of enhanced nitrogen activation when compared to a more conventional furnace approach.

36 MATERIALS SCIENCE↗

Phosphorous transient enhanced diffusion suppression and activation enhancement with cluster carbon co-implantation

Carbon co-implantation is well known as an effective method for suppressing boron/phosphorous transient enhanced diffusion (TED). Germanium pre-amorphization implantation (PAI) is usually applied prior to carbon co-implantation for suppressing channeling tail of dopants. In this study, cluster carbon was applied instead of the combination of germanium PAI and monomer carbon co-implantation prior to phosphorous implantation. Dependence of phosphorous activation and TED on amorphous layer thickness, carbon dose, carbon distribution and substrate temperature have been investigated. Cluster carbon implantation enables thick amorphous layer formation and TED suppression at the same time and low temperature implantation enhances the ability of amorphous layer formation so that shallow junction and low Rs can be achieved without Ge implantation.

36 MATERIALS SCIENCE↗

Effects of surface oxide layer on nanocavity formation and silver gettering in hydrogen ion implanted silicon

We have made an investigation of the surface oxide effects on nanocavity formation in hydrogen implanted silicon and the influence of resultant nanocavities on diffusion and gettering of implanted silver atoms. A wafer with a 200-nm SiO{sub 2} surface layer was implanted with 22.5 keV H ions to a dose of 1 Multiplication-Sign 10{sup 17} cm{sup -2}, yielding the concentration peak of implanted H ions at {approx}140 nm below the SiO{sub 2}/Si interface. Subsequently, two sets of Si samples were prepared, depending on whether the oxide layer was etched off before (Group-A) or after (Group-B) post-H-implantation annealing. As evidenced by transmission electron microscopy, Group-A samples exhibited an array of large-sized nanocavities in hexagon-like shape, extending from the surface to the depth {approx}140 nm, whereas a narrow band of sphere-shaped nanocavities of small size was present around 140 nm below the surface in Group-B samples. These Si samples with pre-existing nanocavities were further implanted with Ag ions in the surface region ({approx}40 nm projected range) and post-Ag-implantation annealing was conducted in the temperature range between 600 and 900 Degree-Sign C. Measurements based on Rutherford backscattering spectroscopy revealed much different behaviors for Ag redistribution and defect accumulation in these two sets of samples. Compared to the case for Group-B Si, Group-A Si exhibited a lower concentration of residual defects and a slower kinetics in Ag diffusion as well. We discuss the role of thick surface oxide in point defect generation and recombination, and the consequence on nanocavity formation and defect retention in Si. The properties of nanocavities, e.g., their depth distribution, size, and even shape, are believed to be responsible for the observed disparities between these samples, including an interesting contrast of surface vs. bulk diffusion phenomena for implanted Ag atoms.

36 MATERIALS SCIENCE↗

Synthesis and properties of ferromagnetic nanostructures embedded within a high-quality crystalline silicon matrix via ion implantation and nanocavity assisted gettering processes

Integrating magnetic functionalities with silicon holds the promise of developing, in the most dominant semiconductor, a paradigm-shift information technology based on the manipulation and control of electron spin and charge. Here, we demonstrate an ion implantation approach enabling the synthesis of a ferromagnetic layer within a defect free Si environment by exploiting an additional implant of hydrogen in a region deep below the metal implanted layer. Upon post-implantation annealing, nanocavities created within the H-implanted region act as trapping sites for gettering the implanted metal species, resulting in the formation of metal nanoparticles in a Si region of excellent crystal quality. This is exemplified by the synthesis of magnetic nickel nanoparticles in Si implanted with H{sup +} (range: ∼850 nm; dose: 1.5 × 10{sup 16 }cm{sup −2}) and Ni{sup +} (range: ∼60 nm; dose: 2 × 10{sup 15 }cm{sup −2}). Following annealing, the H implanted regions populated with Ni nanoparticles of size (∼10–25 nm) and density (∼10{sup 11}/cm{sup 2}) typical of those achievable via conventional thin film deposition and growth techniques. In particular, a maximum amount of gettered Ni atoms occurs after annealing at 900 °C, yielding strong ferromagnetism persisting even at room temperature, as well as fully recovered crystalline Si environments adjacent to these Ni nanoparticles. Furthermore, Ni nanoparticles capsulated within a high-quality crystalline Si layer exhibit a very high magnetic switching energy barrier of ∼0.86 eV, an increase by about one order of magnitude as compared to their counterparts on a Si surface or in a highly defective Si environment.

36 MATERIALS SCIENCE↗

Cracks and blisters formed close to a silicon wafer surface by He-H co-implantation at low energy

We have studied the effect of reducing the implantation energy towards low keV values on the areal density of He and H atoms stored within populations of blister cavities formed by co-implantation of the same fluence of He then H ions into Si(001) wafers and annealing. Using a variety of experimental techniques, we have measured blister heights and depth from the surface, diameter, areal density of the cracks from which they originate as functions of implantation energy and fluence. We show that there is a direct correlation between the diameters of the cracks and the heights of the associated blisters. This correlation only depends on the implantation energy, i.e., only on the depth at which the cracks are located. Using finite element method modeling, we infer the pressure inside the blister cavities from the elastic deformations they generate, i.e., from the height of the blisters. From this, we demonstrate that the gas pressure within a blister only depends on the diameter of the associated crack and not on its depth position and derive an analytical expression relating these parameters. Relating the pressure inside a blister to the respective concentrations of gas molecules it contains, we deduce the areal densities of He and H atoms contained within the populations of blisters. After low-energy implantations (8 keV He{sup +}, 3 keV H{sup +}), all the implanted He and H atoms contribute to the formation of the blisters. There is no measurable exo-diffusion of any of the implanted gases, in contrast to what was assumed at the state of the art to explain the failure of the Smart-Cut technology when using very low energy ion implantation for the fabrication of ultra-thin layers. Alternative explanations must be investigated.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Elucidation of Iron Gettering Mechanisms in Boron-Implanted Silicon Solar Cells

To facilitate cost-effective manufacturing of boron-implanted silicon solar cells as an alternative to BBr 3 diffusion, we performed a quantitative test of the gettering induced by solar-typical boron-implants with the potential for low saturation current density emitters (< 50 fA/cm 2 ). We show that depending on the contamination level and the gettering anneal chosen, such boron-implanted emitters can induce more than a 99.9% reduction in bulk iron point defect concentration. The iron point defect results as well as synchrotron-based Nano-X-ray-fluorescence investigations of iron precipitates formed in the implanted layer imply that, with the chosen experimental parameters, iron precipitation is the dominant gettering mechanism, with segregation-based gettering playing a smaller role. We reproduce the measured iron point defect and precipitate distributions via kinetics modeling. First, we simulate the structural defect distribution created by the implantation process, and then we model these structural defects as heterogeneous precipitation sites for iron. Unlike previous theoretical work on gettering via boron- or phosphorus-implantation, our model is free of adjustable simulation parameters. The close agreement between the model and experimental results indicates that the model successfully captures the necessary physics to describe the iron gettering mechanisms operating in boron-implanted silicon. Furthermore, this modeling capability allows high-performance, cost-effective implanted silicon solar cells to be designed.

14 SOLAR ENERGY↗

SU-F-T-653: Radiation Exposure from Cs-131 Permanent Seed Implants

Purpose: Permanent seed implants have traditionally been used to treat prostate, lung and head or neck cancers using I-125 and Pd-103. Cs-131, which has higher dose rate is being used to treat brain, head and/or neck cancers in our clinic, therefore, we chose to monitor the dose received by surgeons during the extensive procedure. The aims of this work are to assess the level of radiation exposure to surgeons and the instantaneous exposure at bedside and 1 m from patients. Methods: Ten patients received Cs-131 implants for recurrent brain,head and/or neck cancer; the median implanted activity, number of implanted seeds and prescription dose at 0.5 cm from the perpendicular plane of the implant were: 54.3 mCi (14.52 – 77); 19 (4 – 24) and 60 Gy (range 42 – 60) respectively. Radiation exposure was recorded at bedside and 1 m from the patient using Victoreen ion chamber (Fluke Biomedical, Cleveland, OH). Exposure to surgeons was measured using TLD (Mirion Technologies (GDS), Inc., USA). Results: The median equivalent dose rate at 1 m and bedside immediately following implantation were 1.49×10-2 mSv/h (8.77×10-3–2.63×10-2) and 7.76×10-2 mSv/h (3.1×10-2– 1.53×10-1) respectively. Median equivalent dose to surgeons’ hands was 0.60 mSv (0.33 – 1.48) and no doses were detected for whole-body. Surgical reconstruction for one patient was performed 71 days post-implant and resulted in zero exposure to surgeons. Conclusion: The recorded exposure rates were low when compared with the literature. Post procedure surveys at bed site and 1 m indicated that all patients were within safe limits for discharge (< 0.05 mSv/h at 1 m). However, as a precautionary measure, patients were advised to avoid direct contact with children and pregnant women within four weeks of the implant and stay at least at 3 ft from other people. Surgeons doses were well within occupational dose limits.

60 APPLIED LIFE SCIENCES↗