Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION EXCHANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Uptake and binding of La 3+ and Cr 3+ ions by alkali metal substituted alpha-zirconium phosphate

The conversion of alpha-zirconium phosphate, Zr(HPO 4 ) 2 ·H 2 O, to the K-, Rb-, and Cs-phases and the subsequent ion exchange behavior of these alkali metal phases, A-ZrP, with La 3+ and Cr 3+ have been investigated. The conversion to the A-ZrP phases was achieved by reaction with metal chloride, metal hydroxide solution, and confirmed through various techniques, including X-ray powder diffraction, thermogravimetry analysis, IR spectroscopy, scanning and transmission electron microscopy, and X-ray photoelectron spectroscopy. The effect of material hydration, which increased the interlayer distance, was also examined. The ion exchange behavior of the A-ZrP showed strong affinity for both La 3+ , a representative for trivalent lanthanide metals, and Cr 3+ , a representative for the trivalent transition metals, with a rapid, near quantitative removal of the M 3+ ions at a pH of 3 when the ion concentration was ≤25% of the ion exchange capacity of the materials. Additionally, the ion affinity was shown to be pH and concentration-dependent, decreasing with a decrease in pH or an increase in ion concentration. Lastly, the binding strength of La- and Cr-loaded ZrP materials was examined through a series of leaching experiments in a carbonate buffer, phosphate buffer, HEPES buffer, and a series of EDTA solutions at various concentrations. No observable leaching occurred in the carbonate buffer, phosphate buffer, HEPES buffer, or when the EDTA concentration was below 0.1 mM. These results highlight the potential for the A-ZrP materials to provide a platform for trivalent transition metal and trivalent lanthanide radionuclide capture for various applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Operational Experience and Development of a Reliability Model for the ATR Demineralizer System (Slides)

The Advanced Test Reactor (ATR) is a light water reactor with aluminum clad driver fuel. Strict limits are implemented on pH, conductivity, and filterable solids to assure the performance of the driver fuel limit corrosion of the primary coolant system (PCS) pressure boundary components. A bypass demineralizer system is used to maintain PCS coolant within allowable bands for each of the aforementioned variables. Unlike many other reactors, the ATR does not have a filtration system. As such, failure of ion exchange resin in the bypass demineralizer can defeat the purpose of the system and result in high filterable solids in the PCS. Power operations with high filterable solids is prohibited by a technical safety requirement. This paper discusses recent failures of the ATR bypass demineralizer system. The testing and analysis done to deduce the cause of the failures is covered, as well as short term mitigative steps that were taken. To prevent the likelihood of future issues, historical data from the ATR and industry is used to develop a reliability model of the ATR bypass demineralizer system. Evidence of radiolytic decomposition of ion exchange resin was found in the cause investigation. As such, special attention is given to ion exchange resin failure due to high radiation environments. The reliability model is used to develop the ATR testing and maintenance program. Specifically, limits on resin service life are discussed.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Comparison of automated pre-column and post-column analysis of amino acid oligomers

It has been shown that various amino acids will polymerize under plausible prebiotic conditions on mineral surfaces, such as clays and soluble salts, to form varying amounts of oligomers (n = 2-6). The investigations of these surface reactions required a quantitative method for the separation and detection of these amino acid oligomers at the picomole level in the presence of nanomole levels of the parent amino acid. In initial high-performance liquid chromatography (HPLC) studies using a classical postcolumn o-phthalaldehyde (OPA) derivatization ion-exchange HPLC procedure with fluorescence detection, problems encountered included lengthy analysis time, inadequate separation and large relative differences in sensitivity for the separated species, expressed as a variable fluorescent yield, which contributed to poor quantitation. We have compared a simple, automated, pre-column OPA derivatization and reversed-phase HPLC method with the classical post-column OPA derivatization and ion-exchange HPLC procedure. A comparison of UV and fluorescent detection of the amino acid oligomers is also presented. The conclusion reached is that the pre-column OPA derivatization, reversed-phase HPLC and UV detection produces enhanced separation, improved sensitivity and faster analysis than post-column OPA derivatization, ion-exchange HPLC and fluorescence detection.

NASA Discipline Exobiology↗

Method of Synthesizing a Novel Absorbent Titanosilicate Material (UPRM-5)

A titanium silicate variant named UPRM-5 was prepared using tetraethylammonium hydroxide as a structure-directing agent (SDA). Successful detemplation was achieved via ion exchange with NH4Cl. Effective functionalization was obtained after ion exchanging the detemplated material using SrCl2 and BaCl2. Adsorption of CO2 at 25 deg C in Sr(-) and Ba-UPRM-5 materials activated at different temperatures. For low partial pressures, the observed CO2 adsorption capacities increased as follows: NH4-UPRM-5 less than Sr-UPRM-5 less than Ba-UPRM-5. Both the Sr(-) and Ba-UPRM-5 materials exhibited outstanding selectivity for CO2 over CH4, N2 and O2.

Hernandez-Maldonado, Arturo↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

Biocide↗

Hot Water, Cold Reality: Feasibility Assessment of Iodine Removal in Heated Spacecraft Potable Water Systems

The current eXploration Potable Water Dispenser (xPWD) design removes iodine upstream of the heated leg due to concerns with the Activated Carbon and Ion Exchange (ACTEX) functionality in hot water, leaving the downstream volume without residual biocide. The NESC determined that this non-iodinated volume is a concern for microbial growth during exploration missions and proposed 33 biocide architecture options for future missions that could address this concern. The top-ranked architecture out of the report was Option 1: moving the iodine removal media as close to the dispensing needle as possible to minimize the wetted components without biocide in the xPWD. Three main challenges were identified with this proposed configuration. First, the hot water at 175 ± 25 °F is a concern for the potential physical degradation of the ion exchange resin and lowered adsorption capacity in activated carbon. Second, moving the ACTEX or alternative sorption media closer to the dispense needle increases the unheated volume downstream of the heater, challenging the ability for dispensed water to meet temperature requirements. Finally, bubbles evolved from dissolved gas coming out of solution in the heater could clog or reduce the efficiency of the sorption media. To address the first challenge, more thermally robust ion exchange resins were identified and adsorption capacity tests were planned and will be discussed in a companion ICES paper (ICES-2026-5). To address the dispense temperature concerns, allowable bed size and architectural configuration changes are proposed. The value of adding phase separators to remove bubbles and potential implementation schemes are discussed. These findings support the development of potable water systems resilient to microbial risks during long-duration space missions.

PWD↗

Assessing the Long-Term Stability of Anion Exchange Membranes for Electrochemical CO 2 Reduction

Materials and cell components used in CO 2 electrolysis have largely been adapted from technologies initially developed for water electrolysis and fuel cells. However, electrochemical CO 2 reduction introduces distinct material challenges due to the unique chemical environment in this process. Here, in this study, we conducted ex-situ 1000 h stability tests on commonly used anion exchange membranes, exposing them exclusively to electrolytes and organic molecules used or produced during CO 2 electrolysis, at concentrations relevant to and compatible with postseparation processes. Notably, 15% w/w n-propanol and 5 M acetic acid caused complete dissolution or partial disintegration of the membranes unless cross-linking was present and remained stable throughout the test. When the membranes stayed physically intact, most of them exhibited excellent chemical stability in alkaline medium containing alcohols or formic acid, which was confirmed by vibrational spectroscopy and ion exchange capacity measurements. However, exposure to alcohol-and acid-containing solutions led to a substantial increase in swelling and water uptake, with potential implications for mechanical stability, ion/product crossover, and compression management of adjacent components. The potential effects of CO 2 electroreduction products on membrane stability, their subsequent impact on electrolyzer performance, and mitigation strategies are discussed.

CO2RR↗

Biocidal quaternary ammonium resin

Activated carbon (charcoal) and polymeric resin sorbents are widely used in the filtration and treatment of drinking water, mainly to remove dissolved organic and inorganic impurities and to improve the taste. Earlier hopes that activated carbon might "disinfect' water proved to be unfounded. The feasibility of protecting against microbial infestation in charcoal and resin beds such as those to be incorporated into total water reuse systems in spacecraft was investigated. The biocidal effect of IPCD (insoluable polymeric contact disinfectants) in combination with a representative charcoal was assessed. The ion exchange resins (IPCD) were shown to adequately protect charcoal and ion exchange beds.

Janauer, G. E.↗

The corrosion behavior of borosilicate glass in the presence of cementitious waste forms

Borosilicate glasses are widely used for radioactive waste disposal due to their ability to incorporate a variety of contaminants and radionuclides while exhibiting high durability in various disposal scenarios. This research evaluated the dissolution of borosilicate glass using both single-pass-flow-through (ASTM C1662-18) and product consistency test (ASTM C1285-21) methods with different solutions, including a cementitious-contacted water (called grout-contacted, GC, from this point) and solutions with varying levels of dissolved cementitious species such as Si, Ca, Al. Here, the results indicated that the presence of Ca plays a crucial role in suppressing glass corrosion, as evidenced by the slower normalized dissolution rates, which were one order of magnitude lower for boron and two orders of magnitude lower for rhenium, observed in both Ca-amended and GC solutions compared to the pH 12 buffer solution. This effect is attributed to the formation of a dense, low-porosity, and strongly bonded calcium silicate hydrate (CSH) layer on the glass surface, which implies that a glass corrosion process is influenced by ion exchange involving alkali ions Na + , K + , Ca 2+ , and hydrogen-containing species. A small number of glass particles treated in the GC solution showed minor corrosion pits in the form of shallow craters with an average diameter of approximately 500 μm. This observation is correlated with a significant reduction, 2000 to 3000 times lower, in the cumulative volume of glass pores, indicating that smaller pore voids were “sealed” in the presence of Ca 2+ ions, likely attributed to the formation of CSH precipitation or other corrosion products such as calcium carbonate saturated from the grout solution. These findings suggest that the presence of dissolved Ca in the GC solution can slow down the dissolution of borosilicate glass, contrary to the expected trend of higher dissolution rates resulting from exposure to high alkaline and thus higher pH solutions.

36 MATERIALS SCIENCE↗

On the use of antibiotics to reduce rhizoplane microbial populations in root physiology and ecology investigations

No straightforward method exists for separating the proportion of ion exchange and respiration due to rhizoplane microbial organisms from that of root ion exchange and respiration. We examined several antibiotics that might be used for the temporary elimination of rhizoplane bacteria from hydroponically grown wheat roots (Triticum aestivum cv. Veery 10). Each antibiotic was tested for herbicidal activity and plate counts were used to enumerate bacteria and evaluate antibiotic kinetics. Only lactam antibiotics (penicillins and cephalosporins) did not reduce wheat growth rates. Aminoglycosides, the pyrimidine trimethoprim, colistin and rifampicin reduced growth rates substantially. Antibiotics acted slowly, with maximum reductions in rhizoplane bacteria occurring after more than 48 h of exposure. Combinations of nonphytotoxic antibiotics reduced platable rhizoplane bacteria by as much as 98%; however, this was generally a reduction from about 10(9) to 10(6) colony forming units per gram of dry root mass, so that many viable bacteria remained on root surfaces. We present evidence which suggests that insufficient bacterial biomass exists on root surfaces of nonstressed plants grown under well-aerated conditions to quantitatively interfere with root nitrogen absorption measurements.

NASA Discipline Life Support Systems↗

Erosion rate diagnostics in ion thrusters using laser-induced fluorescence

We have used laser-induced fluorescence (LIF) to monitor the charge-exchange ion erosion of the molybdenum accelerator electrode in ion thrusters. This real-time, nonintrusive method was implemented by operating a 30cm-diam ring-cusp thruster using xenon propellant. With the thruster operating at a total power of 5 kW, laser radiation at a wavelength of 390 nm (corresponding to a ground state atomic transition of molybdenum) was directed through the extracted ion beam adjacent to the downstream surface of the molybdenum accelerator electrode. Molybdenum atoms, sputtered from this surface as a result of charge-exchange ion erosion, were excited by the laser radiation. The intensity of the laser-induced fluorescence radiation, which is proportional to the sputter rate of the molybdenum atoms, was measured and correlated with variations in thruster operating conditions such as accelerator electrode voltage, accelerator electrode current, and test facility background pressure. We also demonstrated that the LIF technique has sufficient sensitivity and spatial resolution to evaluate accelerator electrode lifetime in ground-based test facilities.

Gaeta, C. J.↗

Sulfate Conversion of Reillex HPQ Anion Exchange Resin for Disposal (Interim Report)

This report describes preliminary data to validate the Savannah River Plutonium Processing Facility’s (SRPPF) flowsheet for conversion of used Reillex HPQ anion exchange resin from the nitrate form to the sulfate form. The nitrate form is an oxidizer and therefore does not meet acceptance criteria for disposal at the Waste Isolation Pilot Plant (WIPP). The purpose of this study is to develop data to support acceptance for this disposition pathway. Due to the challenges characterizing the nitrate concentration on solid resin, the data developed to date are based upon indirect analysis of the ion exchange column effluent by ion chromatography. These challenges are discussed and two methods for quantification of nitrate directly on the resin are recommended for further development: TGA-MS and permanganate digestion followed by IC. The resin used for this work was provided in the chloride form; this is the form in which resin is supplied by the manufacturer. However, it had to be converted to the nitrate form, which is the form that will be used in SRPPF’s ion exchange process, prior to use in the sulfate conversion experiments. The chloride-form resin was characterized. A lab-scale procedure for the conversion of Reillex HPQ resin from the chloride to nitrate form was validated. The nitrate-form resin was assessed for particle size and chloride concentration to ensure it met SRPPF’s facility specifications. The baseline sulfate conversion flowsheet was tested. However, nitrate was still detectable in the effluent after approximately 10 bed volumes of 1 M sodium sulfate had been passed through the resin bed. Additional experiments were performed to assess the effect of increasing the feed volume, reducing the flowrate, the use of 2 M sulfuric acid instead of sodium sulfate, and the use of irradiated resin. The sulfuric acid test was the only one which provided a nondetectable nitrate concentration (<0.002 M) in the effluent. Detectable nitrate in the column effluent suggests that nitrate is still present on the resin itself.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dilute Regeneration-Driven Membrane Capacitive Deionization of Synthetic Seawater Using Nanopatterned Membranes and Prussian Blue Analog Electrodes

Membrane capacitive deionization (MCDI) offers energy-efficient seawater desalination but is limited at high salinity by membrane resistance and incomplete electrode regeneration. Nanopatterned ion-exchange membranes, dilute regeneration protocols, and Prussian blue analog (PBA)-functionalized electrodes are combined in a flow-by-MCDI cell. Nanopatterned ion-exchange membranes (hexagonal, octagonal, double-ring, rectangular) enhance interfacial ion transport, with hexagonal geometry delivering ≈12.5% greater surface area and the best performance. PBA-functionalized electrodes increase salt adsorption and charge-transfer kinetic rates. The integrated system lowers the area-specific resistance by 45 Ω cm2, resulting in a 500 mV reduction in the cell voltage for a current density of 2 mA cm−2 for a 35 000 ppm NaCl feed. This improves the energy-normalized salt adsorption six fold (64–382 mmol J−1). Low salinity (2000 ppm) and mixed-salt regeneration sustains a ≈39% water recovery and stable performance for at least seven cycles. Overall, combining nanopatterned membranes, which promote confinement-enhanced ion mobility, and PBA electrodes, which enhance salt adsorption, improved the energy efficiency of MCDI.

Hasan, Mahmudul↗

Enhanced Optical Contrast and Switching in Near‐Infrared Electrochromic Devices by Optimizing Conjugated Polymer Oligo(Ethylene Glycol) Sidechain Content and Gel Electrolyte Composition

Abstract A detailed investigation addressing the effects of functionalizing conjugated polymers with oligo(ethylene glycol) (EG n ) sidechains on the performance and polymer‐electrolyte compatibility of electrochromic devices (ECDs) is reported. The electrochemistry for a series of donor‐acceptor copolymers having near‐infrared (NIR)‐optical absorption, where the donor fragment is 3,4‐ethylenedioxythiophene (EDOT) or an EG n functionalized bithiophene (g2T) and the acceptor fragment is diketopyrrolopyrrole (DPP) functionalized with branched alkyl or EG n sidechains, is extensively probed. ECDs are next fabricated and it is found that EG n sidechain incorporation must be finely balanced to promote polymer‐electrolyte compatibility and provide efficient ion exchange. Proper electrolyte‐cation pairing and polymer structural tuning affords a 2x increase in optical contrast (from 12% to 24%) and >60x reduction in switching time (from 20 to 0.3 s). Atomic force microscopy (AFM)/grazing incidence wide‐angle X‐ray scattering (GIWAXS) characterization of the polymer film morphology/microstructure reveals that an over‐abundance of EG n sidechains generates large polymer crystallites, which can suppress ion exchange. Lastly, time‐of‐flight secondary ion mass spectrometry (ToF‐SIMS) indicates sidechain/electrolyte identity does not influence the electrolyte penetration depth into the films, and EG n sidechain inclusion increases electrolyte cation uptake. The material structural design insight and guidelines regarding the polymer‐electrolyte ion insertion/expulsion dynamics reported here should be of significant utility for developing next‐generation mixed ionic‐electronic conducting materials.

Chemistry↗

Three-grid accelerator system for an ion propulsion engine

An apparatus is presented for an ion engine comprising a three-grid accelerator system with the decelerator grid biased negative of the beam plasma. This arrangement substantially reduces the charge-exchange ion current reaching the accelerator grid at high tank pressures, which minimizes erosion of the accelerator grid due to charge exchange ion sputtering, known to be the major accelerator grid wear mechanism. An improved method for life testing ion engines is also provided using the disclosed apparatus. In addition, the invention can also be applied in materials processing.

Brophy, John R.↗