Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION IMPLANTATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In-Situ RBS Channelling Studies Of Ion Implanted Semiconductors And Insulators

The experimental set-up at the ion beam facility in Jena allows the performance of Rutherford backscattering spectrometry (RBS) in channeling configuration at any temperature between 15 K and room temperature without changing the environment or the temperature of the sample. Doing RBS channeling studies at 15 K increases the sensitivity to defects, because the influence of lattice vibrations is reduced. Thus, the very early processes of ion induced damage formation can be studied and the cross section of damage formation per ion in virgin material, P, can be determined. At 15 K ion-beam induced damage formation itself can be investigated, because the occurrence of thermal effects can be widely excluded. In AlAs, GaN, and ZnO the cross section P measured at 15 K can be used to estimate the displacement energy for the heavier component, which is in reasonable agreement with other experiments or theoretical calculations. For a given ion species (here Ar ions) the measured cross section P exhibits a quadratic dependence P{proportional_to}P{sub SRIM}{sup 2} with P{sub SRIM} being the value calculated with SRIM using established displacement energies from other sources. From these results the displacement energy of AlN can be estimated to about 40 eV. Applying the computer code DICADA to calculate the depth distribution of displaced lattice atoms from the channeling spectra, indirect information about the type of defects produced during ion implantation at 15 K can be obtained. In some materials like GaN or ZnO the results indicate the formation of extended defects most probably dislocation loops and thus suggest an athermal mobility of defect at 15 K.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Boron Profile Sharpening in Ultra-Shallow p{sup +}-n Junction Produced by Plasma Immersion Ion Implantation from BF{sub 3} Plasma

We have investigated plasma immersion ion implantation (PI{sup 3}) of boron with energies of 500 eV (doses up to 2x10{sup 15} cm{sup -2}) from BF{sub 3} plasma with He pre-amorphizing implantation (PAI)(energy 3 keV, dose 5x10{sup 16} cm{sup -2}). Implanted samples were subjected to RTA (T = 900 to 1050 deg. C, t = 2 to 24 sec and spike anneal). SIMS analysis of boron profiles revealed its anomalous behavior. For short RTA times the profile tail (below 5x10{sup 19} cm{sup -3}) moves toward the surface and then, as in the usual diffusion, toward the bulk at longer annealing times.

36 MATERIALS SCIENCE↗

Stress engineering for crack and dendrite prevention in solid electrolytes via ion implantation

Solid-state batteries represent a promising technology that offers safer and more densely packed energy storage. A primary cause of failure in solid-state cells is the penetration of metal dendrites through the solid electrolyte. Here, we report that fluorine-ion implantation can enhance the mechanical resistance of solid electrolyte Li 6.5 La 3 Zr 1.5 Ta 0.5 O 12 to dendrite propagation by inducing residual compressive stress in the subsurface of the electrolyte. Ion implantation modifies subsurface residual stress and also alters the electrolyte’s surface, resulting in multifunctional enhancement. The combined chemical and mechanical effects of ion implantation enable reversible lithium metal stripping and plating at elevated current densities while enhancing air stability and mitigating the formation of a harmful carbonate layer at the surface. This study provides new insights into a scalable dendrite-suppression strategy for designing solid-state batteries suitable for cycling at room temperature and low stack pressures.

25 ENERGY STORAGE↗

Introduction of the MC3-II/GP system, medium current ion implanter with enhanced multi-charge beam current

The MC3-II/GP is a leading-edge single-wafer medium-current ion implanter, newly developed by SEN Corporation. It demonstrates exceptional productivity based on a high speed wafer-handling station and enhanced beam current. It covers a substantively wider energy range in order to fully meet advanced device requirements. Retaining the superior features of the MC3-II/WR, the MC3-II/GP provides a remarkable increase of multiply-charged beam current coupled with longer ion source lifetime. Another advanced feature of the MC3-II/GP is a 30 second or 14% reduction in auto beam setup time. These improvements enable a fabrication line to reduce the total number of ion implanters and dramatically reduce COO.

43 PARTICLE ACCELERATORS↗

Dose Control System in the Optima XE Single Wafer High Energy Ion Implanter

Photoresist outgassing can significantly compromise accurate dosimetry of high energy implants. High energy implant even at a modest beam current produces high beam powers which create significantly worse outgassing than low and medium energy implants and the outgassing continues throughout the implant due to the low dose in typical high energy implant recipes. In the previous generation of high energy implanters, dose correction by monitoring of process chamber pressure during photoresist outgassing has been used. However, as applications diversify and requirements change, the need arises for a more versatile photoresist correction system to match the versatility of a single wafer high energy ion implanter. We have successfully developed a new dosimetry system for the Optima XE single wafer high energy ion implanter which does not require any form of compensation due to the implant conditions. This paper describes the principles and performance of this new dose system.

43 PARTICLE ACCELERATORS↗

Electron conductivity in GeTe and GeSe upon ion implantation of Bi

This paper presents results on ion implantation of bismuth in GeTe and GeSe films. The conductivity and the thermopower of amorphous chalcogenide films are investigated. Electron conductivity in the films is attained at the Bi implantation doses higher than (1.5–2) × 10{sup 16} cm{sup −2}. In conjunction with the structural modification in the films as revealed Raman spectroscopy, the results suggest the structural re-arrangement of the amorphous network occurs via weakening the bonds of a lower energy. The onset of electron conductivity is hindered by a stronger bond in an alloy. In GeTe, this is the Ge-Ge bond.

36 MATERIALS SCIENCE↗

Effects of nitrogen ion implantation time on tungsten films deposited by DC magnetron sputtering on AISI 410 martensitic stainless steel

Nitrogen ion implantation time on tungsten thin film deposited on surface of AISI 410 steel has been performed. Tungsten thin film produced by dc magnetron sputtering method was deposited on AISI 410 martensitic stainless steel substrates, and then the nitrogen ions were implanted on tungsten thin film. The objective of this research is to investigate the effects of implantation deposition time on surface roughness, microhardness, specific wear and corrosion rate of nitrogen implanted on tungsten film. Magnetron sputtering process was performed by using plasma gas of argon (Ar) to bombardier tungsten target (W) in a vacuum chamber with a pressure of 7.6 x 10{sup −2} torr, a voltage of 300 V, a sputter current of 80 mA for sputtered time of 10 minutes. Nitrogen implantation on tungsten film was done with an initial pressure of 3x10{sup −6} mbar, a fluence of 2 x 10{sup 17} ions/cm{sup 2}, an energy of 100 keV and implantation deposition times of 0, 20, 30 and 40 minutes. The surface roughness, microhardness, specific wear and corrosion rate of the films were evaluated by surfcorder test, Vickers microhardness test, wear test and potentiostat (galvanostat) test respectively. The results show that the nitrogen ions implanted deposition time on tungsten film can modify the surface roughness, microhardness, specific wear and corrosion rate. The minimum surface roughness, specific wear and corrosion rate can be obtained for implantation time of 20 minutes and the maximum microhardness of the film is 329 VHN (Vickers Hardness Number) for implantation time of 30 minutes. The specific wear and corrosion rate of the film depend directly on the surface roughness.

36 MATERIALS SCIENCE↗

Stress influenced trapping processes in Si based multi-quantum well structures and heavy ions implanted Si

Multi-quantum well structures and Si wafers implanted with heavy iodine and bismuth ions are studied in order to evaluate the influence of stress on the parameters of trapping centers. The experimental method of thermostimullatedcurrents without applied bias is used, and the trapping centers are filled by illumination. By modeling the discharge curves, we found in multilayered structures the parameters of both 'normal' traps and 'stress-induced' ones, the last having a Gaussian-shaped temperature dependence of the cross section. The stress field due to the presence of stopped heavy ions implanted into Si was modeled by a permanent electric field. The increase of the strain from the neighborhood of I ions to the neighborhood of Bi ions produces the broadening of some energy levels and also a temperature dependence of the cross sections for all levels.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fourth-generation plasma immersion ion implantation and deposition facility for hybrid surface modification layer fabrication

The fourth-generation plasma immersion ion implantation and deposition (PIIID) facility for hybrid and batch treatment was built in our laboratory recently. Comparing with our previous PIIID facilities, several novel designs are utilized. Two multicathode pulsed cathodic arc plasma sources are fixed on the chamber wall symmetrically, which can increase the steady working time from 6 h (the single cathode source in our previous facilities) to about 18 h. Meanwhile, the inner diameter of the pulsed cathodic arc plasma source is increased from the previous 80 to 209 mm, thus, large area metal plasma can be obtained by the source. Instead of the simple sample holder in our previous facility, a complex revolution-rotation sample holder composed of 24 shafts, which can rotate around its axis and adjust its position through revolving around the center axis of the vacuum chamber, is fixed in the center of the vacuum chamber. In addition, one magnetron sputtering source is set on the chamber wall instead of the top cover in the previous facility. Because of the above characteristic, the PIIID hybrid process involving ion implantation, vacuum arc, and magnetron sputtering deposition can be acquired without breaking vacuum. In addition, the PIIID batch treatment of cylinderlike components can be finished by installing these components on the rotating shafts on the sample holder.

36 MATERIALS SCIENCE↗

PROGRESS IN CHARACTERIZATION OF PRECIPITATES AND DEFECT STRUCTURES IN Mg+ ION IMPLANTED CUBIC SILICON CARBIDE

This report describes the progress of our current experimental effort on Mg+ ion implanted 3C-SiC. Following our initial study [ ] that suggests possible formation of Mg2Si and MgC2 precipitates as well as tetrahedral voids in 24Mg+ ion implanted 3C-SiC, we have designed specific experiments to confirm the results and examine the inclusions and defects. Relatively low fluence (5.0×1015 24Mg+/cm2) implantation in 3C-SiC was performed to reduce defect concentrations and isolate individual defect features for characterization. In addition, 25Mg+ isotope was implanted in 3C-SiC to the same previously applied ion fluence (9.6×1016 ions/cm2) for atom probe tomography (APT) study of precipitates. Each set of the samples was annealed at 1573 K for 2, 6 and 12 h, respectively. The depth profiles of the implanted Mg were measured using secondary ion mass spectrometry (SIMS) before and after the annealing steps. The samples are currently being analyzed using transmission electron microscopy (TEM) and APT.

Environmental Molecular Sciences Laboratory↗

Plasma immersion ion implantation for sub-22 nm node devices: FD-SOI and Tri-Gate

Here, we present and discuss the electrical characteristics of fully depleted MOSFET transistors of planar and tridimensional architecture, doped by Plasma Immersion Ion Implantation (PIII) or Beam Line Ion Implantation (BLII). Both techniques delivered similar and satisfactory results in considering the planar architecture. For tri-dimensional Tri-Gate transistors, the results obtained with PIII are superior.

36 MATERIALS SCIENCE↗

Understanding and engineering of NiGe/Ge junction formed by phosphorus ion implantation after germanidation

Modulation of the effective electron Schottky barrier height (eSBH) of NiGe/Ge contacts induced by phosphorus ion implantation after germanide formation was investigated by considering local inhomogeneity in the eSBH. Systematic studies of NiGe/Ge contact devices having various germanide thicknesses and ion implantation areas indicated the threshold dopant concentration at the NiGe/Ge interface required for eSBH modulation and negligible dopant diffusion even at NiGe/Ge interface during drive-in annealing, leading to variation in the eSBH between the bottom and sidewall portions of the NiGe regions. Consequently, this method makes it possible to design source/drain contacts with low-resistivity Ohmic and ideal rectifying characteristics for future Ge-based transistors.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Basic Aspects of the Formation and Activation of Boron Junctions Using Plasma Immersion Ion Implantation

This study investigates the basic aspects of junction formation using Plasma Immersion Ion Implantation using BF{sub 3} and addresses the role of (pre)amorphization, C(F)-co-implantation, plasma parameters (bias, dose) and the thermal anneal cycle (spike versus msec laser anneal). The basic physics are studied using Secondary Ion Mass Spectrometry, sheet resistance and using four point probe and RsL. Profiles with junction depths ranging from 10-12 nm and sheet resistance values below 800 Ohm/sq are readily achievable.

36 MATERIALS SCIENCE↗

FeN foils by nitrogen ion-implantation

Iron nitride samples in foil shape (free standing, 500 nm in thickness) were prepared by a nitrogen ion-implantation method. To facilitate phase transformation, the samples were bonded on the substrate followed by a post-annealing step. By using two different substrates, single crystal Si and GaAs, structural and magnetic properties of iron nitride foil samples prepared with different nitrogen ion fluences were characterized. α″-Fe{sub 16}N{sub 2} phase in iron nitride foil samples was obtained and confirmed by the proposed approach. A hard magnetic property with coercivity up to 780 Oe was achieved for the FeN foil samples bonded on Si substrate. The feasibility of using nitrogen ion implantation techniques to prepare FeN foil samples up to 500 nm thickness with a stable martensitic phase under high ion fluences has been demonstrated. A possible mechanism was proposed to explain this result. This proposed method could potentially be an alternative route to prepare rare-earth-free FeN bulk magnets by stacking and pressing multiple free-standing thick α″-Fe{sub 16}N{sub 2} foils together.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Impact of ion-implantation-induced band gap engineering on the temperature-dependent photoluminescence properties of InAs/InP quantum dashes

We report on the effects of the As/P intermixing induced by phosphorus ion implantation in InAs/InP quantum dashes (QDas) on their photoluminescence (PL) properties. For nonintermixed QDas, usual temperature-dependent PL properties characterized by a monotonic redshift in the emission band and a continual broadening of the PL linewidth as the temperature increases, are observed. For intermediate ion implantation doses, the inhomogeneous intermixing enhances the QDas size dispersion and the enlarged distribution of carrier confining potential depths strongly affects the temperature-dependent PL properties below 180 K. An important redshift in the PL emission band occurs between 10 and 180 K which is explained by a redistribution of carriers among the different intermixed QDas of the ensemble. For higher implantation doses, the homogeneous intermixing reduces the broadening of the localized QDas state distribution and the measured linewidth temperature behavior matches that of the nonintermixed QDas. An anomalous temperature-dependent emission energy behavior has been observed for extremely high implantation doses, which is interpreted by a possible QDas dissolution.

36 MATERIALS SCIENCE↗

Microwave Annealing of Ion Implanted 4H-SiC

Ultra-fast high-temperature microwave annealing at temperatures as high as 2050 deg. C for 30 s has been performed on phosphorus ion-implanted 4H-SiC for phosphorus doping concentrations in the range 5x10{sup 19} cm{sup -3}-8x10{sup 20} cm{sup -3}. For comparison, inductive heating furnace anneals were performed at 1800 deg. C-1950 deg. C for 5 min. Electrical resistivity of the P{sup +}-implanted samples decreased with increasing annealing temperature reaching a minimum value of 6.8x10{sup -4} {Omega}cm for 2050 deg. C/30 s microwave annealing and a slightly higher value for 1950 deg. C/5 min inductive heating furnace annealing. X-ray rocking curve measurements showed that the microwave annealing not only removed the lattice damage introduced by the ion-implantation process, but also the defects present in the original virgin sample as well.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thermal annealing behavior of hydrogen and surface topography of H 2 + ion implanted tungsten

Tungsten (W) has been proposed as a plasma-facing material (PFM) in fusion reactors due to its outstanding properties. Degradation of the material properties is expected to occur as a result of hydrogen (H) isotope permeation and trapping in W. In this study, two polycrystalline W plates were implanted with 80 keV H 2 + ions to a fluence of 2E21 H+/m2 at room temperature (RT). Time-of-flight secondary ion mass spectrometry (ToF-SIMS), focused ion beam (FIB) and scanning electron microscopy (SEM) were used for sample characterization. The SIMS data shows that H atoms are distributed well beyond the ion projected range. Isochronal annealing appears to suggest two H release stages that might be associated with the reported activation energies. H release at RT was observed between days 10 and 70 following ion implantation, and the level was maintained over the next 60 days. In addition, FIB/SEM results exhibit H2 blister formation near the surface of the as-implanted W. The blister distribution remains unchanged after thermal annealing up to 600 °C.

H diffusion and release↗

High Current Low Energy Beam Transport for Ion Implanters

One of the last remaining frontiers of the semiconductor industry is low energy ion implantation. Since the invention of the transistor, the trend has been to miniaturize semiconductor devices. As devices get smaller, shallower ion implantation for semiconductor manufacturing is needed.

Rohatgi, Upendra↗