Search NASA⌕ Search

SEARCH · Search NASA

Results for “ION INJECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Estimation of radiation fields generated by injected beam losses at the EIC's RCS

This technical note provides a general estimate of radiation fields generated by injection fault events at the electron-ion collider´s (EIC) Rapid Cycling Synchrotron (RCS), calculated with the Monte Carlo particle transport and interaction code FLUKA. Calculations were performed for two major injection loss scenarios that involve iron targets and featured different electron beam energy and current values. The results presented here constitute a first order assessment of several radiological quantities associated with these electromagnetic showers and their potential effect on environmental safety and health (ESH) systems in the vicinity of injection areas.

43 PARTICLE ACCELERATORS↗

An Induction-Type Septum Magnet for the Hadron and Electron Injection of the EIC Complex

The design of the electron Ion Collider (EIC) project is under way to be built at the Brookhaven National Laboratory (BNL) with the collaboration of the Thomas Jefferson National Accelerator Facility (TJNAF). The Rapid Cycling Synchrotron (RCS) which is part of the EIC accelerator complex will accelerate the electron beam up to 18 GeV, and the beam will be injected into the Electron Storage Ring (ESR) to collide with the hadron beam circulating in the Hadron Storage Ring (HSR) which is a modified version of the Relativistic Heavy Ion Collider (RHIC). All three synchrotrons will be located in the same tunnel. This technical note provides information on the latest electromagnetic design of the induction-type septum magnet which will be employed by EIC to Inject the beam into the HSR and RCS and also extract the beam from the RCS.

43 PARTICLE ACCELERATORS↗

Flow Injection Electrochemical Quartz Crystal Microbalance with ICP-OES Detection: Electroprecipitation and Stripping of Lanthanum and Neodymium in a Flow Cell

We used an improved version of our hyphenated analysis technique, flow injection electrochemical quartz crystal microbalance (EQCM) with inductively coupled optical emission spectroscopy, to investigate the electroprecipitation of lanthanum and neodymium from flowing solutions. The improved version has two independent flow injection circuits, allowing different conditions for electrochemical precipitation (pH=4.3 or 2.6) and quick stripping (2% HNO3) with EQCM mass detection and ICP-OES elemental analysis. Lanthanum or neodymium ions in a 500 uL sample were injected into a carrier stream and deposited onto an EQCM housed in a micro flow cell, owing to a localized high-pH layer. The deposits are subsequently stripped from the electrode using HNO3 and analyzed downstream using an ICP-OES. We found that using acidic solutions without supporting electrolyte leads to an increase of the amount of lanthanum detected by 4-fold. The enhanced deposition can be attributed to enhanced mass transfer by migration. Furthermore, we showed that by applying chronopotentiometry, we can detect a change in the hydrogen evolution reaction mechanism that enables the precipitation of lanthanides on the surface of the electrode. Understanding and enhancing the deposition of lanthanides is relevant for elemental or isotopic detection in nuclear forensics.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Non‐Traditional Positively‐Biased Narrow‐Band Perovskite Single‐Crystal Photodetectors Enabled by Interfacial Engineering

Abstract The positive bias in theory narrows down the depletion region and thus results in significant charge injection, which should be detrimental to charge generation and collection performance for traditional photodetectors. Here, instead, it is found that the external quantum efficiency (EQE) is increased by more than 50 times when the photodetector is positively biased. A positive bias of +6 V drives ion migration of Br − and Cs + towards the anode and cathode, respectively, leading to self‐doping within bulk single crystals to form an advantageous p‐i‐n junction for better charge collection in the devices. Meanwhile, the injected holes are allowed to tunnel through the cesium lead bromide/fullerene interface to reach the cathode which also significantly contributes to the enhancement of EQE in the forward‐biased devices. The positively‐biased narrow‐band (full width at half maxima (FWHM) = 16 nm) photodetectors exhibit a specific detectivity of 6.5 × 10 10 Jones at 550 nm, along with the −3 dB cutoff frequency of 2776 Hz. By manipulating charge injection and ion migration using interfacial engineering, a class of non‐traditional, positively‐biased, and highly narrow‐band photodetectors is demonstrated, which offers an alternative design strategy for imaging, biosensing, automatic control, and optical communication.

Li, Junchi↗

Low-energy H- beam injectors for particle accelerators: upgrade requirements, challenges and future plans [Slides]

High brightness, negative hydrogen ion sources are used extensively in large, accelerator-based, user facilities operating worldwide. Negative hydrogen beams have become the preferred means of filling circular accelerators and storage rings as well as enabling efficient extraction from cyclotrons. Much larger beams of H- ions are also utilized for neutral beams injection into fusion machines and will be discussed in a separate companion presentation. Some of the accelerator facilities include the US Spallation Neutron Source (SNS), Japan Proton Accelerator Research Complex (J-PARC), Rutherford Appleton Laboratory (RAL-ISIS), Los Alamos Neutron Science Center (LANSCE), Fermi National Accelerator Laboratory (FNAL), Brookhaven National Laboratory (BNL), the CERN LHC injector, the Chinese Spallation Neutron Source (CSNS) as well as numerous installations of D-Pace (licenced by TRIUMF) ion sources used mainly with cyclotrons. Many facilities are currently working on various improvement / upgrade projects, both in the near and long term, which are driving further development of their ion source and LEBT (Low Energy Beam Transport) and, in some cases, their overall front end injector system. This report will first provide a simple description of each facilities existing ion source and LEBT and summarize the operational parameters which are currently being routinely injected into their accelerators. Next, the parametric goals of each of the facilities upgrade projects are specified as well as development efforts currently underway to meet these requirement and improvement goals. It is hoped that that this work will not only capture the current state-of-the-art of worldwide H- beam injectors and clarify the research goals and efforts of the community in general but will also encourage further inter laboratory collaborations.

43 PARTICLE ACCELERATORS↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

High-performance plasmas after pellet injections in Wendelstein 7-X

A significant improvement of plasma parameters in the optimized stellarator W7-X is found after injections of frozen hydrogen pellets. The ion temperature in the post-pellet phase exceeds 3 keV with 5 MW of electron heating and the global energy confinement time surpasses the empirical ISS04-scaling. The plasma parameters realized in such experiments are significantly above those in comparable gas-fuelled discharges. Here, we present details of these pellet experiments and discuss the main plasma properties during the enhanced confinement phases. Local power balance is applied to show that the heat transport in post-pellet phases is close to the neoclassical level for the ion channel and is about a factor of two above that level for the combined losses. In comparable gas-fuelled discharges, the heat transport is by about ten times larger than the neoclassical level, and thus is largely anomalous. It is further observed that the improvement in the transport is related to the peaked density profiles that lead to a stabilization of the ion-scale turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A novel measurement of marginal Alfvén eigenmode stability during high power auxiliary heating in JET

The interaction of Alfvén eigenmodes (AEs) and energetic particles is one of many important factors determining the success of future tokamaks. In JET, eight in-vessel antennas were installed to actively probe stable AEs with frequencies ranging 25–250 kHz and toroidal mode numbers |n| < 20. During the 2019–2020 deuterium campaign, almost 7500 resonances and their frequencies f 0 , net damping rates γ < 0, and toroidal mode numbers were measured in almost 800 plasma discharges. From a statistical analysis of this database, continuum and radiative damping are inferred to increase with edge safety factor, edge magnetic shear, and when including non-ideal effects. Both stable AE observations and their associated damping rates are found to decrease with |n|. Active antenna excitation is also found to be ineffective in H-mode as opposed to L-mode; this is likely due to the increased edge density gradient’s effect on accessibility and ELM-related noise’s impact on mode identification. A novel measurement is reported of a marginally stable, edge-localized ellipticity-induced AE probed by the antennas during high-power auxiliary heating (ion cyclotron resonance heating and neutral beam injection) up to 25 MW. NOVA-K kinetic-MHD simulations show good agreement with experimental measurements of f 0 , γ, and n, indicating the dominance of continuum and electron Landau damping in this case. Similar experimental and computational studies are planned for the recent hydrogen and ongoing tritium campaigns, in preparation for the upcoming DT campaign.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The ion-gas-neutral interactions with surfaces-2 (IGNIS-2) facility for the study of plasma–material interactions

The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma–material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two <5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.

Instruments & Instrumentation↗

Activating Bi p- orbitals in Dispersed Clusters of Amorphous BiO x for Electrocatalytic Nitrogen Reduction

Catalytic strategies based on main group metals are significantly less advanced than those of transition metal catalysis, leaving untapped areas of potentially fruitful research. Here, in this study, we demonstrate an effective approach for the modulation of Bi 6p energy levels during the construction of atomically dispersed clusters of amorphous BiO x . Bi oxidation state is proposed to strongly affects the nitrogen fixation activity, with the half-occupied p z orbitals of the Bi 2+ ions being highly efficient toward electron injection into the inert N 2 molecule. With sufficient catalytic sites to adsorb and activate N 2 , the bonding between N 2 and catalyst is able to be in situ identified. The catalyst shows an outstanding Faraday efficiency (≈30 %) and high yield (≈113 μg h -1 mg -1 cat ) in NH 3 production, outperforming most of the existing catalysts in aqueous solution. These results lay the basis for developing the potential of p-block elements for catalysis of multi-electron reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Total Dissolved Nitrogen and Ammonia Data for the East River Watershed, Colorado (2015-2025)

This data package contains mean values for total dissolved nitrogen (TDN) and ammonia concentrations for water samples taken from the East River Watershed in Colorado. The East River is part of the Watershed Function Scientific Focus Area (WFSFA) located in the Upper Colorado River Basin, United States. TDN was analyzed using a Shimadzu Total Nitrogen Module (TNM-1) combined with the TOC-VCSH analyzer (Shimadzu Corporation, Japan). TNM-1 is a non-specific measurement of total nitrogen (TN). All nitrogen species in samples are combusted to nitrogen monoxide and nitrogen dioxide, then reacted with ozone to form an excited state of nitrogen dioxide. Upon returning to ground state, light energy is emitted. Then, TDN is measured using a chemiluminescence detector. Ammonia was determined using a Lachat's QuikChem 8500 Series 2 Flow Injection Analysis System (LACHAT Instruments, QuckChem 8500 series 2, Automated Ion Analyzer, Loveland, Colorado). When ammonia in water samples is heated (60 degrees C) with salicylate and hypochlorite in an alkaline phosphate buffer, an emerald green color is produced which is proportional to the ammonia concentration. The color is intensified by the addition of nitroprusside. Ethylenediaminetetraacetic acid (EDTA) is added to the buffer to prevent the interference of metal ions (Ca, Mg, and Fe etc.). Ammonia-N is then determined by LACHAT flow injection and a colorimetric assay at an absorbance wavelength 660 nm. (Reference: LACHAT Instruments: QuickChem Method 90-107-06-3-A, Determination of Ammonia by Flow Injection Analysis (High Throughput, Salicylate Method/DCIC) (Multi Matrix method). Written by Lynn Egan (Application group), February 08, 2011.) All files are labeled by location and variable, and data reported are the mean values upon replicate measurements. All samples were analyzed under a rigorous quality assurance and quality control (QA/QC) process as detailed in the methods. This data package contains (1) a zip file (tdn_ammonia_data_2015-2025.zip) containing a total of 299 files: 298 data files of ammonia and TDN data from across the Lawrence Berkeley National Laboratory (LBNL) Watershed Function Scientific Focus Area (SFA) which is reported in .csv files per location and a locations.csv (1 file) with latitude and longitude for each location; (2) a file-level metadata (v7_20260901_flmd.csv) file that lists each file contained in the dataset with associated metadata; (3) a data dictionary (v7_20260901_dd.csv) file that contains terms/column_headers used throughout the files along with a definition, units, and data type; (4) PDF and docx files for the determination of Method Detection Limits (MDLs) for TDN data, which has been updated in 2026-08; and (5) PDF and docx files for the detemination of Method Detection Limits (MDLs) for Ammonia and the Interferences by LACHAT Flow Injection Analysis. Missing values within the anion data files are noted as either "-9999" or "0.0" for not detectable (N.D.) data. There are a total of 105 locations containing TDN and Ammonia-N data. Update 2020-10-07: Updated the data files to remove times from the timestamps, so that only dates remain. The data values have not changed. Update 2021-04-11: Added Determination of Method Detection Limits (MDLs) for DIC, NPOC and TDN Analyses and Determination of Method Detection Limit for Ammonia and the Interferences by LACHAT Flow Injection Analysis documents, which can be accessed as PDFs or with Microsoft Word.Update on 6/10/2022: versioned updates to this dataset was made along with these changes: (1) updated total dissolved nitrogen and ammonia data for all locations up to 2021-12-31, (2) removal of units from column headers in datafiles, (3) added row underneath headers to contain units of variables, (4) restructure of units to comply with CSV reporting format requirements, (5) added -9999 for empty numerical cells, and (6) the addition of the file-level metadata (flmd.csv) and data dictionary (dd.csv) were added to comply with the File-Level Metadata Reporting Format. Update on 2022-09-09: Updates were made to reporting format specific files (file-level metadata and data dictionary) to correct swapped file names, add additional details on metadata descriptions on both files, add a header_row column to enable parsing, and add version number and date to file names (v2_20220909_flmd.csv and v2_20220909_dd.csv). Update on 2022-12-20: Updates were made to both the data files and reporting format specific files. Units were listed incorrectly, but have been fixed to reflect correct units (ug/L). File level metadata (flmd) and data dictionary (dd) files were updated to reflect the updated versions of these files. Available data was added up until 2022-06-01. Update on 2023-08-08: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-01-05. The file level metadata and data dictionary files were updated to reflect the additional data added. Update on 2024-03-11: Updates were made to both the data files and reporting format specific files. New available anion data was added, up until 2023-10-27. Further, revisions to the data files were made to remove incorrect data points (from 1970 and 2001). The reporting format specific files were updated to reflect the additional data added. Revised versions of the PDF and docx files for determination of MDLs for TDN were added to replace previous versions. Update on 2025-05-15: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2024 (September 30, 2024). International Generic Sample Numbers (IGSNs), when registered, were added to the data files. The reporting format specific files were updated to reflect the additional data added. Update on 2026-09-01: Updates were made to both the data files and reporting format specific files. New available TDN and Ammonia-N data was added, up until the end of WY2025 (September 30, 2025). Updated versions, as of 2026-08-10, of the PDF and docx files for determination of MDLs for TDN data were added to this dataset.

54 ENVIRONMENTAL SCIENCES↗

Record of Decision: LEBT Energy Change

The LAMP Conceptual Design (LCD), as described in the LAMP Conceptual Design Report incorporates multiple 100-keV low-energy beam transport (LEBT) lines between the ion sources and the radiofrequency quadrupole (RFQ). The LEBT lines transport H + and H - beams from their respective ion sources to the RFQ entrance, and provide the required manipulations (focusing, steering, chopping, etc.) to the ion beams to prepare them for injection into the RFQ and further acceleration.

43 PARTICLE ACCELERATORS↗

Accelerating discoveries at DIII-D with the Integrated Research Infrastructure

DIII-D research is being accelerated by leveraging high performance computing (HPC) and data resources available through the National Energy Research Scientific Computing Center (NERSC) Superfacility initiative. As part of this initiative, a high-resolution, fully automated, whole discharge kinetic equilibrium reconstruction workflow was developed that runs at the NERSC for most DIII-D shots in under 20 min. This has eliminated a long-standing research barrier and opened the door to more sophisticated analyses, including plasma transport and stability. These capabilities would benefit from being automated and executed within the larger Department of Energy Advanced Scientific Computing Research program’s Integrated Research Infrastructure (IRI) framework. The goal of IRI is to empower researchers to meld DOE’s world-class research tools, infrastructure, and user facilities seamlessly and securely in novel ways to radically accelerate discovery and innovation. For transport, we are looking at producing flux matched profiles and also using particle tracing to predict fast ion heat deposition from neutral beam injection before a shot takes place. Our starting point for evaluating plasma stability focuses on the pedestal limits that must be navigated to achieve better confinement. This information is meant to help operators run more effective experiments, so it needs to be available rapidly inside the DIII-D control room. So far this has been achieved by ensuring the data is available with existing tools, but as more novel results are produced new visualization tools must be developed. In addition, all of the high-quality data we have generated has been collected into databases that can unlock even deeper insights. This has already been leveraged for model and code validation studies as well as for developing AI/ML surrogates. The workflows developed for this project are intended to serve as prototypes that can be replicated on other experiments and can be run to provide timely and essential information for ITER, as well as next stage fusion power plants.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Resonance Ionization Spectroscopy Experiment at Facility for Rare Isotope Beams

This manuscript reports on the commissioning of the Resonance Ionization Spectroscopy Experiment (RISE) at the BEam COoler and LAser spectroscopy (BECOLA) facility at Facility for Rare Isotope Beams (FRIB). The instrument implements the collinear resonance ionization spectroscopy technique for sensitive measurements of isotope shifts and hyperfine structure of short-lived isotopes produced at FRIB. The existing BECOLA beamline was extended to integrate an electrostatic ion-beam bender and an ion detector at ultrahigh vacuum. An injection-seeded titanium-sapphire laser and a multiharmonic pulsed neodymium-doped yttrium aluminum garnet laser were installed to perform resonant excitation and selective ionization. Commissioning tests were performed to demonstrate the capabilities of the instrument by measuring the hyperfine structure of stable 27 Al produced in an offline ion source. The RISE instrument is ready and operational for future studies of short-lived isotopes at FRIB.

Atomic spectra↗

A fusion relevant data-driven engineering void swelling model for 9Cr tempered martensitic steels

The UCSB database on cavity evolution in 9-12Cr tempered martensitic steels (TMS), includes the results for both dual heavy and helium ion (DII), and High Flux Isotope Reactor (HFIR) in situ helium injection (ISHI) neutron irradiations at 500°C. These results were combined with literature single ion and fission neutron irradiation data to derive a model for the void volume fraction, f v , as a function of displacements per atom (dpa) and transmutant helium concentrations in atomic parts per million (appm). The scientific foundation for the paper is described in a companion paper entitled “Cavity Evolution and Void Swelling in Dual Ion Irradiated Tempered Martensitic Steels”. Here, in this study, we show that f v (dpa, He/dpa) is described by the incubation dose, dpa i , for the onset of void growth, and the post-incubation growth rate, f v ’(%/dpa). Both dpa i and f v ’ decrease with increasing He/dpa at > ~ 5. The dpa i is also lower for the ISHI neutron irradiations at the same He/dpa. Single heavy ion and fission reactor neutron irradiations, with low He/dpa ratios, have a much larger dpa i . Based on a combined analysis of DII, single ion, ISHI and fission neutron data, we further show that the post-incubation f v data analyzed here have a common empirical curve shape, with f v ’ reaching up to ~ 0.2%/dpa at very high dpa. We also show that f v ’ can be predicted based on a physical model of defect partitioning between evolving sinks. At 500°C and fusion relevant He/dpa ≈ 10, the best-fit model predicts nominal swelling, S = f v /(1-f v ), of ~ 1.1, 4.9 and 16% at 50, 100 and 200 dpa, respectively. The physically motivated, data-driven model includes estimated uncertainties for both dpa i and f v ’.

36 MATERIALS SCIENCE↗

Bifurcated merging operations of two spherical tokamak plasmas for reconnection heating and magnetic helicity injection

In tokamak plasma merging experiments, high-power ion heating is achieved only when the current sheet thickness is compressed to ion gyroradius ρ i . The magnetic reconnection converts 40%–50% of the reconnecting magnetic field energy (B rec 2 /2μ 0 ) into the ion heating energy (W i ) with the scaling law of W i proportional to B rec 2 . If the compressed current sheet thickness is larger than ρ i the magnetic reconnection converts only 5%–10% of B rec 2 /2μ 0 into W i . Finally, the high-power ion heating can be understood from the experimental finding that the poloidal electric field due to electrostatic quadrupolar potential in the downstream region increases linearly with both B rec and the guide field B t .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Current status of the electron transport line from RCS to ESR: RTE line

The electron injection system of the U.S. Electron-Ion Collider (EIC) is located outside of the RHIC tunnel. Electrons beams accelerated by the Rapid Cycling Synchrotron (RCS) must be transported to the Electron Storage Ring (ESR), which resides within the RHIC tunnel. To accomplish this, a dedicated beam transport line, referred to as RTE (RCS-to-ESR) line is being designed. The proposed conceptual design comprises three main sections; RCS extraction, a vertical bend and dispersion suppression region, and ESR injection matching. The extraction section uses pulsed kickers and septum magnets to achieve a total deflection angle of 3 degrees. To align the injection section with ESR, the beamline must provide a vertical elevation of 1.68 m, and an array of FODO cells is used to suppress the vertical dispersion. The total length of the RTE line is approximately 133 m, and this paper presents the current design status and considerations for this transport line.

Accelerator Physics↗