Search NASA⌕ Search

SEARCH · Search NASA

Results for “Image”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Quantifying the heterogeneity of shale through statistical combination of imaging across scales

Shale is a highly heterogeneous material across multiple scales. A typical shale consists of nanometer-scale pores and minerals mixed with macro-scale fractures and particles of varying size. High-resolution imaging is crucial for characterizing the composition and microstructure of this rock. Yet, it is generally not feasible to image a large sample of shale at a high resolution over a large field of view (FOV), thus limiting a full characterization of the microstructure of this material. We present a stochastic framework based on multiple-point statistics that uses high-resolution training images to enhance low-resolution images obtained over a large FOV. Here, we demonstrate the approach using X-ray micro-tomography images of organic-rich Woodford shale obtained at two different resolutions and FOV. Results show that the proposed technique can generate realistic high-resolution images of the microstructure of shale over a large FOV.

58 GEOSCIENCES↗

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical System

High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MR Imaging of Chondrogenic Tumors: Update on Select Imaging Challenges

Purpose of Review: This review article discusses the updated World Health Classification of chondrogenic skeletal tumors and the role of conventional and advanced magnetic resonance (MR) imaging in the evaluation of chondrogenic skeletal lesions with emphasis on select diagnostic dilemmas. Recent Findings: The majority of benign chondrogenic skeletal lesions have typical radiographic and MR features. Conventional MR imaging sequences can be helpful in the distinction of tumor-like lesions from chondrogenic tumors, and the evaluation of anatomic extent, particularly with regard to the detection of soft tissue masses associated with a chondrosarcoma (CS). Benign, atypical, and malignant chondrogenic lesions can have overlapping features on diffusion-weighted imaging (DWI) with apparent diffusion coefficient (ADC) mapping although dynamic contrast-enhanced (DCE) sequences can be helpful in the characterization of chondrogenic tumors as benign or malignant. Patients with multiple chondrogenic tumor conditions or syndromes are predisposed to developing CS and extra-skeletal malignancies, and as such, a small subset may benefit from imaging surveillance. Summary: The majority of chondrogenic skeletal lesions can be characterized confidently on imaging. In the small subset of intermediate and malignant chondrogenic lesions with overlapping imaging and pathological features, a multidisciplinary approach should be used.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Retrieving images from tarnished daguerreotypes using X-ray fluorescence imaging with an X-ray micro beam with tunable energy

We report recent observations using a synchrotron X-ray micro-beam to retrieve images from tarnished 19th century daguerreotypes. We confirm that high quality image can always be retrieved from tarnished plates using Hg L α XRF as long as the bulk of the image particles and their distribution remains intact. We also report results from using tunable tender X-rays (2 - 7 keV) to conduct imaging in high vacuum at energy above the Ag L-edge and the Hg M-edge, extracting images using Ag L α and Hg M α , respectively among others (e.g., S to track corrosion). Images obtained with the surface sensitive total electron yield (TEY) and the bulk sensitive fluorescence yield (FLY) as well as corresponding micro-XANES are reported. Flux tolerance to high intensity X-beam is also explored. These results and their implications for cultural heritage research are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A single-pixel X-ray imager concept and its application to secure radiographic inspections

Imaging technology is generally considered too invasive for arms control inspections due to the concern that it cannot properly secure sensitive features of the inspected item. However, this same sensitive information, which could include direct information on the form and function of the items under inspection, could be used for robust arms control inspections. The single-pixel X-ray imager (SPXI) is introduced as a method to make such inspections, capturing the salient spatial information of an object in a secure manner while never forming an actual image. The method is built on the theory of compressive sensing and the single pixel optical camera. The performance of the system is quantified here using simulated inspections of simple objects. Measures of the robustness and security of the method are introduced and used to determine how such an inspection would be made which can maintain high robustness and security. In particular, it is found that an inspection with low noise (<1%) and high undersampling (>256×) exhibits high robustness and security.

Arms Control↗

Iridium Atoms Bonded to Crystalline Powder MgO: Characterization by Imaging and Spectroscopy

Samples with low loadings of metals on well-defined supports provide some of the best opportunities to determine the metal–support structure and bonding. We illustrate methods for characterizing atomically dispersed heavy metals on metal oxide supports by aberration-corrected scanning transmission electron microscopy (STEM) complemented by fluorescence detection extended X-ray absorption fine structure and infrared spectroscopies. STEM images of Ir atoms derived from Ir(C 2 H 4 ) 2 (acac) (acac = acetylacetonato) on high-surface-area MgO powder were obtained with minimized electron beam damage by quickly recording images near where the focus had been established. The images show that iridium at a loading of 1.0 wt % on MgO calcined at 1073 K was atomically dispersed, populating much of the surface of the MgO particles, which had irregular shapes—consequently the Ir atoms were bonded at various sites to two or three surface O atoms. In contrast, MgO calcined at 1273 K consisted of almost perfectly cubic crystals, and Ir atoms at a loading of only 0.01 wt % on this nearly ideal support were anchored preferentially at edges and corners of the (100) faces and bonded to three surface O atoms. The latter results indicate a path forward for the determination of precise structures of atomically dispersed metals on crystalline metal oxide supports.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Cross-calibration of Fuji TR image plate and RAR 2492 x-ray film to determine the response of a DITABIS Super Micron image plate scanner

Fuji TR image plate is frequently used as a replacement detector medium for x-ray imaging and spectroscopy diagnostics at NIF, Omega, and Z facilities. However, the familiar Fuji BAS line of image plate scanners is no longer supported by the industry, and so a replacement scanning system is needed. While the General Electric Typhoon line of scanners could replace the Fuji systems, the shift away from photo stimulated luminescence units to 16-bit grayscale Tag Image File Format (TIFF) leaves a discontinuity when comparing data collected from both systems. For the purposes of quantitative spectroscopy, a known unit of intensity applied to the grayscale values of the TIFF is needed. The DITABIS Super Micron image plate scanning system was tested and shown to potentially rival the resolution and dynamic range of Kodak RAR 2492 x-ray film. However, the absolute sensitivity of the scanner is unknown. In this work, a methodology to cross calibrate Fuji TR image plate and the absolutely calibrated Kodak RAR 2492 x-ray film is presented. Details of the experimental configurations used are included. An energy dependent scale factor to convert Fuji TR IP scanned on a DITABIS Super Micron scanner from 16-bit grayscale TIFF to intensity units (i.e., photons per square micron) is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Real-time X-ray phase-contrast imaging using SPINNet—a speckle-based phase-contrast imaging neural network

X-ray phase-contrast imaging has become indispensable for visualizing samples with low absorption contrast. In this regard, speckle-based techniques have shown significant advantages in spatial resolution, phase sensitivity, and implementation flexibility compared with traditional methods. However, the computational cost associated with data inversion has hindered their wider adoption. By exploiting the power of deep learning, we developed a speckle-based phase-contrast imaging neural network (SPINNet) that significantly improves the imaging quality and boosts the phase retrieval speed by at least 2 orders of magnitude compared to existing methods. To achieve this performance, we combined SPINNet with a coded-mask-based technique, an enhanced version of the speckle-based method. Using this scheme, we demonstrate the simultaneous reconstruction of absorption and phase images on the order of 100 ms, where a traditional correlation-based analysis would take several minutes even with a cluster. In addition to significant improvement in speed, our experimental results show that the imaging and phase retrieval quality of SPINNet outperform existing single-shot speckle-based methods. Furthermore, we successfully demonstrate SPINNet application in x-ray optics metrology and 3D x-ray phase-contrast tomography. Our result shows that SPINNet could enable many applications requiring high-resolution and fast data acquisition and processing, such as in situ and in operando 2D and 3D phase-contrast imaging and real-time at-wavelength metrology and wavefront sensing.

36 MATERIALS SCIENCE↗

A Molecular-MNIST Dataset for Machine Learning Study on Diffraction Imaging and Microscopy

An image dataset of 10 different size molecules, where each molecule has 2,000 structural variants, is generated from the 2D cross-sectional projection of Molecular Dynamics trajectories. The purpose of this dataset is to provide a benchmark dataset for the increasing need of machine learning, deep learning and image processing on the study of scattering, imaging and microscopy.

BASIC BIOLOGICAL SCIENCES,OTHER INSTRUMENTATION↗

Intact, Commercial Lithium-Polymer Batteries: Spatially Resolved Grating-Based Interferometry Imaging, Bragg Edge Imaging, and Neutron Diffraction

We survey several neutron imaging and diffraction methods for non-destructive testing and evaluation of intact, commercial lithium-ion batteries. Specifically, far-field interferometry was explored as an option to probe a wide range of autocorrelation lengths within the batteries via neutron imaging. The dark-field interferometry images change remarkably from fresh to worn batteries, and from charged to discharged batteries. When attempting to search for visual evidence of battery degradation, neutron Talbot-Lau grating interferometry exposed battery layering and particle scattering through dark-field imaging. Bragg edge imaging also reveals battery wear and state of charge. Neutron diffraction observed chemical changes between fresh and worn, charged and discharged batteries. However, the utility of these methods, for commercial batteries, is dependent upon battery size and shape, with 19 to 43 mAh prismatic batteries proving most convenient for these experimental methods. This study reports some of the first spatially resolved, small angle scattering (dark-field) images showing battery degradation.

36 MATERIALS SCIENCE↗

Galaxy–Galaxy Weak-lensing Measurements from SDSS. I. Image Processing and Lensing Signals

We present our image processing pipeline that corrects the systematics introduced by the point-spread function (PSF). Using this pipeline, we processed Sloan Digital Sky Survey (SDSS) DR7 imaging data in r band and generated a galaxy catalog containing the shape information. Based on our shape measurements of the galaxy images from SDSS DR7, we extract the galaxy–galaxy (GG) lensing signals around foreground spectroscopic galaxies binned in different luminosities and stellar masses. We estimated the systematics, e.g., selection bias, PSF reconstruction bias, PSF dilution bias, shear responsivity bias, and noise rectification bias, which in total is between −9.1% and 20.8% at 2 σ levels. The overall GG lensing signals we measured are in good agreement with Mandelbaum et al. The reduced χ {sup 2} between the two measurements in different luminosity bins are from 0.43 to 0.83. Larger reduced χ {sup 2} from 0.60 to 1.87 are seen for different stellar mass bins, which is mainly caused by the different stellar mass estimator. The results in this paper with higher signal-to-noise ratio are due to the larger survey area than SDSS DR4, confirming that more luminous/massive galaxies bear stronger GG lensing signals. We divide the foreground galaxies into red/blue and star-forming/quenched subsamples and measure their GG lensing signals. We find that, at a specific stellar mass/luminosity, the red/quenched galaxies have stronger GG lensing signals than their counterparts, especially at large radii. These GG lensing signals can be used to probe the galaxy–halo mass relations and their environmental dependences in the halo occupation or conditional luminosity function framework.

79 ASTRONOMY AND ASTROPHYSICS↗

The need for standardization of nuclear cardiology reporting and data system (NCAD-RADS): Learning from coronary artery disease (CAD), breast imaging (BI), liver imaging (LI), and prostate imaging (PI) RADS

Newer structured reporting manners, the reporting and data system (RADS), have made vast steps in improving standardized and structured reporting, allowing better communication between radiologists and referring providers. This has been implemented in several fields: breast (BI-RADS), lung (Lung-RADS), liver (LI-RADS), thyroid (TI-RADS), prostate (PI-RADS), and in cardiovascular radiology (CAD-RADS). The field of nuclear cardiology began its efforts of standardization years ago; however, a widespread standardized reporting structure has not yet been adopted. Such an approach in nuclear cardiology, the nuclear cardiology reporting and data system (NCAD-RADS), will assist radiologists and treating clinicians in conveying and understanding reports and determining the appropriate next steps in management. By linking explicit findings to defined recommendations, patients will receive more consistent and appropriate care.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Atomic-scale imaging of ultrafast materials dynamics

The advent of short-pulse electron and x-ray sources has enabled pump-probe approaches for elucidating ultrafast materials dynamics. From such studies, a comprehensive picture of the time-dependent evolution of the initial steps of energy deposition, propagation, relaxation, and conversion in a wide range of materials can be generated. In this article, we provide an overview of the capabilities of femtosecond electron and x-ray scattering for resolving structural dynamics of materials. With such approaches, time resolutions are ultimately limited by the durations of the electron and x-ray pulses, and dynamics can be studied at length scales spanning atomic to mesoscale dimensions. The articles in this issue represent a cross section of the vigorous activity occurring in the study of light-induced ultrafast materials dynamics as it relates to charge carriers, surfaces and interfaces, lattice-coupling mechanisms, coherent structural motions, and next-generation instrument development. Here, the approaches highlighted here are leading to new physical insights, new possibilities for engineering the properties of matter, and ultimately, a new understanding of materials functionality on ultrasmall and ultrashort spatiotemporal scales.

36 MATERIALS SCIENCE↗