In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

analysis↗

Impact of Utilizing Photos and Deimos as Waypoints for Mars Human Surface Missions

Phobos and Deimos, the moons of Mars, are interesting exploration destinations that offer extensibility of the Asteroid Redirect Mission (ARM) technologies. Solar Electric Propulsion (SEP), asteroid rendezvous and docking, and surface operations can be used to land on and explore the moons of Mars. The close Mars vicinity of Phobos and Deimos warrant examining them as waypoints, or intermediate staging orbits, for Mars surface missions. This paper outlines the analysis performed to determine the mass impact of using the moons of Mars both as an intermediate staging point for exploration as well as for in-situ recourse utilization, namely propellant, to determine if the moons are viable options to include in the broader Mars surface exploration architecture.

Cianciolo, Alicia D.↗

Evidence for the nonuniform distribution of microwave attenuating clouds in the atmosphere of Venus - Mariner 2

Data obtained by Mariner 2 in three microwave-radiometer scans of Venus are reanalyzed using model Venusian atmospheres based on observations by Veneras 4 through 8 as well as by Mariners 5 and 10. It is noted that a previous analysis of this microwave data revealed a CO2 percentage and surface pressures that were considerably lower than those measured in situ as well as a longitudinal temperature gradient that was much larger than that indicated by the more recent measurements. The reanalysis shows that the measured scan ratios require different average values of microwave-cloud opacity for each scan and that the anomalous temperature decrease observed in the south polar region of the terminator scan requires a very opaque microwave cloud between local zenith angles of 40 and 70 deg. It is suggested that a nonuniform microwave-attenuating cloud is located below the IR and visible cloud deck of Venus.

Jones, D. E.↗

Mars Volatiles and Climate Surveyor (MVACS) Integrated Payload for the Mars Polar Lander Mission

The Mars Volatiles and Climate Surveyor (MVACS) integrated payload for the Mars Polar Lander will be launched in January 1999, with a scheduled landing on Mars' south-polar layered deposits in December 1999. Over the course of its 90-day nominal mission during the martian southern spring and summer seasons, it will make in situ measurements that will provide new insights into the behavior and distribution of martian volatiles, MVACS consists of four major instrument systems: a surface stereo imager (SSI), which will acquire multispectral stereo images of the surface and atmosphere; a 2-m robotic arm (RA), which will dig a O.5-m deep trench and acquire surface and subsurface samples that will be imaged by a focusable robotic arm camera (RAC), which will take close-up images of surface and subsurface samples at a spatial resolution of 21 micron; a meteorology package (MET), which will make the first measurements of surface pressure, temperature, and winds in Mars' southern hemisphere and employ a tunable diode laser (TDL) spectrometer to measure the water-vapor concentration and isotopic composition of CO2 in the martian atmosphere; and a thermal and evolved gas analyzer (TEGA), which will use differential scanning calorimetry and TDL-evolved gas analysis to determine the concentrations of ices, adsorbed volatiles, and volatile-bearing minerals in surface and subsurface soil samples. The unique in situ measurements made by MVACS at its high-latitude landing site will define a number of important aspects of the physical, isotopic, and chemical nature of the martian near-surface and subsurface environment that will be valuable in better understanding Mars meteorites and returned samples, as well as in the search for martian resources that could be utilized by humans.

Paige, D. A.↗

Analysis of a Radioisotope Thermal Rocket Engine

The Triton Hopper is a concept for a global hopper vehicle which uses a radioisotope rocket engine and In-situ propellant acquisition to explore the surface of Neptune's moon, Triton. The current Triton Hopper concept stores heated Nitrogen in a spherical tank to be used as the propellant. The aim of the research was to investigate the benefits of storing propellant at ambient temperature and heating it through the use of a thermal block during engine operation, as opposed to storing gas at a high temperature. Lithium, Lithium Fluoride and Beryllium were considered as possible materials for the thermal block. A heat energy analysis indicated that a lithium thermal mass would provide the highest heat energy for a temperature change from 900 Celsius to -100 Celsius. A heat transfer analysis was performed for Nitrogen at -100 Celsius flowing through 1000 passages inside a 1kg lithium thermal block at a temperature of 900 Celsius. The system was analyzed as turbulent flow through a tube with constant surface temperature. The analysis indicated that the propellant reached a maximum temperature of 877 Celsius before entering the nozzle. At this exit temperature, the average specific impulse [I(sub sp)] of the engine was determined to be 157s. Previous studies for the stored heated gas concept suggest that the engine would have an average I(sub sp) of approximately 52s. Thus, the use of a thermal block concept results in a 200 percent engine performance increase. In addition, a tank sizing study was performed to determine if the concept is feasible in terms of mass requirements. The mass for a spherical carbon fiber COPV storing 35kg of nitrogen at an initial temperature of -100 Celsius and a pressure of 1000psia, was determined to be 7.2kg. The specific impulse analysis indicated that the maximum engine performance is obtained for a mass ratio of 5kg of Nitrogen per every 1kg of lithium thermal mass. Thus for 35kg of Nitrogen the total thermal mass would be 7kg. This brings the total mass of the system to 49.2.kg which is less than the 56kg landing payload capacity of the Triton Hopper. Finally, an insulation analysis using 10mm of MLI insulation indicated that a total of 22 watts of heat are lost to the environment. With the heat loss known, the power required to heat the thermal mass to 900 Celsius in 24 days was determined to be 2.15 watts. The study's results allowed us to conclude that the thermal mass concept is the better option due to the performance increase provided, the low power requirement and its compliance with the landing mass requirement of the Triton Hopper.

Radioisotope↗

Remote X-Ray Diffraction and X-Ray Fluorescence Analysis on Planetary Surfaces

The legacy of planetary X-ray Diffraction (XRD) and X-ray Fluorescence (XRF) began in 1960 when W. Parish proposed an XRD instrument for deployment on the moon. The instrument was built and flight qualified, but the Lunar XRD program was cancelled shortly before the first human landing in 1969. XRF chemical data have been collected in situ by surface landers on Mars (Viking 1 & 2, Pathfinder) and Venus (Venera 13 & 14). These highly successful experiments provide critical constraints on our current understanding of surface processes and planetary evolution. However, the mineralogy, which is more critical to planetary surface science than simple chemical analysis, will remain unknown or will at best be imprecisely constrained until X-ray diffraction (XRD) data are collected. Recent progress in X-ray detector technology allows the consideration of simultaneous XRD (mineralogic analysis) and high-precision XRF (elemental analysis) in systems miniaturized to the point where they can be mounted on fixed landers or small robotic rovers. There is a variety of potential targets for XRD/XRF equipped landers within the solar system, the most compelling of which are the poles of the moon, the southern highlands of Mars and Europa.

Blake, David F.↗

Spatially resolved organic analysis of the Allende meteorite

The distribution of polycyclic aromatic hydrocarbons (PAHs) in the Allende meteorite has been probed with two-step laser desorption/laser multiphoton ionization mass spectrometry. This method allows direct in situ analysis with a spatial resolution of 1 sq mm or better of selected organic molecules. Spectra from freshly fractured interior surfaces of the meteorite show that PAH concentrations are locally high compared to the average concentrations found by wet chemical analysis of pulverized samples. The data suggest that the PAHs are primarily associated with the fine-grained matrix, where the organic polymer occurs. In addition, highly substituted PAH skeletons were observed. Interiors of individual chondrules were devoid of PAHs at the detection limit (about 0.05 ppm).

Zenobi, Renato↗

Molecular and Higher Precision Isotopic Measurements of the Mars Atmosphere and Subsurface Volatiles

In response to the question 'what to do next' at Mars we explore the value of a high precision in situ measurement of isotopic and trace gas constituents in the atmosphere combined with a similar analysis of gas extracted from near surface rocks and soils. The scientific goals are to advance our understanding of the evolution of the Martian atmosphere and to search for fossils of past geochemical conditions. One element of this program that ties directly to the goals of the Astrobiology Program will be a sensitive search for simple or complex organic molecules contained in the atmosphere and in the solid phase. The broad chemical and isotopic analysis planned insures that a highly successful program will be carried out even if no organics are detected. We will demonstrate that the technology to carry out this Program is presently in hand.

Mahaffy, P. R.↗

Mission Design for the Deep Space 4/Champollion Comet Sample Return Mission

The Deep Space 4/Champollion mission will be the first to land a spacecraft on the surface of a comet, perform in-situ science, and collect a subsurface sample which it will return to Earth for analysis. This paper describes the trade studies resulting in the current reference mission, which uses solar electric propulsion to rendezvous with the comet Tempel 1 in December 2005 after launching in April 2003. An option which uses a chemical propulsion system to return to Earth is discussed.

4/Champollion↗

Enhanced Microbial Detection Capabilities by a Rapid Portable Instrument

We present data describing a progression of continuing technology development - from expanding the detection capabilities of the current PTS unit to re-outfitting the instrument with a protein microarray increasing the number of detectable compounds. To illustrate the adaptability of the cartridge format, on-orbit operations data from the ISS demonstrate the detection of the fungal cell wall compound beta-glucan using applicable LOCAD-PTS cartridges. LOCAD-PTS is a handheld device consisting of a spectrophotometer, an onboard pumping mechanism, and data storage capabilities. A suite of interchangeable cartridges lined with four distinct capillaries allow a hydrated sample to mix with necessary reagents in the channels before being pumped to the optical well for spectrophotometric analysis. The reagents housed in one type of cartridge trigger a reaction based on the Limulus Amebocyte Lysate (LAL) assay, which results in the release of paranitroaniline dye. The dye is measured using a 395 nm filter. The LAL assay detects the Gram-negative bacterial cell wall molecule, endotoxin or lipopolysaccharide (LPS). The more dye released, the greater the concentration of endotoxin in the sample. Sampling, quantitative analysis, and data retrieval require less than 20 minutes. This is significantly faster than standard culture-based methods, which require at least a 24 hour incubation period.Using modified cartridges, we demonstrate the detection of Gram negative bacteria with protein microarray technology. Additionally, we provide data from multiple field tests where both standard and advanced PTS technologies were used. These tests investigate the transfer of target microbial molecules from one surface to another. Collectively, these data demonstrate that the new cartridges expand the number of compounds detected by LOCAD-PTS, while maintaining the rapid, in situ analysis characteristic of the instrument. The unit provides relevant data for verifying sterile sample collection protocols, which are critical for conducting accurate scientific experiments during future missions to the Moon and Mars.

Morris, Heather↗

Version 4 of the SMAP Level-4 Soil Moisture Algorithm and Data Product

The NASA Soil Moisture Active Passive (SMAP) mission Level-4 Soil Moisture (L4_SM) product provides global, 3-hourly, 9-km resolution estimates of surface (0-5 cm) and root-zone (0-100 cm) soil moisture with a mean latency of ~2.5 days. The underlying L4_SM algorithm assimilates SMAP radiometer brightness temperature (Tb) observations into the NASA Catchment land surface model using a spatially-distributed ensemble Kalman filter. Version 4 of the L4_SM modeling system includes a reduction in the upward recharge of surface soil moisture from below under non-equilibrium conditions, resulting in reduced bias and improved dynamic range of L4_SM surface soil moisture compared to earlier versions. This change and additional technical modifications to the system reduce the mean and standard deviation of the observation-minus-forecast Tb residuals and overall soil moisture analysis increments while maintaining the skill of the L4_SM soil moisture estimates versus independent in situ measurements; the average, bias-adjusted RMSE in Version 4 is 0.039 m(exp 3) m(exp -3) for surface and 0.026 m(exp 3) m(exp -3) for root-zone soil moisture. Moreover, the coverage of assimilated SMAP observations in Version 4 is near-global owing to the use of additional satellite Tb records for algorithm calibration. L4_SM soil moisture uncertainty estimates are biased low (by 0.01-0.02 m(exp 3) m(exp -3)) against actual errors (computed versus in situ measurements). L4_SM runoff estimates, an additional product of the L4_SM algorithm, are biased low (by 35 mm year (exp -1)) against streamflow measurements. Compared to Version 3, bias in Version 4 is reduced by 46% for surface soil moisture uncertainty estimates and by 33% for runoff estimates.

RMSE↗

Microwave Extraction of Volatiles for Mars Science and ISRU

The greatest advantage of microwave heating for volatiles extraction is that excavation can be greatly reduced. Surface support operations would be simple consisting of rovers with drilling capability for insertion of microwaves down bore holes to heat at desired depths. The rovers would also provide support to scientific instruments for volatiles analysis and for volatiles collection and storage. The process has the potential for a much lower mass and a less complex system than other in-situ processes. Microwave energy penetrates the surface heating within with subsequent sublimation of water or decomposition of volatile containing minerals. On Mars the volatiles should migrate to the surface to be captured with a cold trap. The water extraction and transport process coupled with atmospheric CO2 collection could readily lead to a propellant production process, H2O + CO2 yields CH4 + O2.

Ethridge, Edwin C.↗

The Miniaturized Moessbauer Spectrometer MIMOS II of the Athena Payload for the 2003 MER Missions

A first-order requirement of spacecraft missions that land on Mars is instrumentation for in situ mineralogical analysis. Moessbauer Spectroscopy is a powerful tool for quantitative analysis of Fe-bearing materials. The Athena Moessbauer spectrometer MIMOS II on the martian surface will provide: (1) identification of iron-bearing phases (e.g., oxides, silicates, sulfides, sulfates, and carbonates), (2) quantitative measurement of the distribution of iron among its oxidation states (e.g., Fe(2+)/Fe(3+) ratio), and (3) quantitative measurement of the distribution of iron among iron-bearing phases (e.g., the relative proportions of iron in olivine, pyroxene, and magnetite in a basalt) in rocks and soils. Moessbauer data will also be highly complementary with chemical analyses from the APXS and the Mini-TES compositional data. Mars is a particularly good place to do Moessbauer mineralogy because its surface is iron rich (approx. 20% Fe as Fe2O3). Moessbauer spectrometers that are built with backscatter measurement geometry require no sample preparation, a factor important for in situ planetary measurements.

G Klingelhoefer↗

Challenges of Rover Navigation at the Lunar Poles

Observations from Lunar Prospector, LCROSS, Lunar Reconnaissance Orbiter (LRO), and other missions have contributed evidence that water and other volatiles exist at the lunar poles in permanently shadowed regions. Combining a surface rover and a volatile prospecting and analysis payload would enable the detection and characterization of volatiles in terms of nature, abundance, and distribution. This knowledge could have impact on planetary science, in-situ resource utilization, and human exploration of space. While Lunar equatorial regions of the Moon have been explored by manned (Apollo) and robotic missions (Lunokhod, Cheng'e), no surface mission has reached the lunar poles.

Robotics↗

Land Surface Verification Toolkit (LVT) - A Generalized Framework for Land Surface Model Evaluation

Model evaluation and verification are key in improving the usage and applicability of simulation models for real-world applications. In this article, the development and capabilities of a formal system for land surface model evaluation called the Land surface Verification Toolkit (LVT) is described. LVT is designed to provide an integrated environment for systematic land model evaluation and facilitates a range of verification approaches and analysis capabilities. LVT operates across multiple temporal and spatial scales and employs a large suite of in-situ, remotely sensed and other model and reanalysis datasets in their native formats. In addition to the traditional accuracy-based measures, LVT also includes uncertainty and ensemble diagnostics, information theory measures, spatial similarity metrics and scale decomposition techniques that provide novel ways for performing diagnostic model evaluations. Though LVT was originally designed to support the land surface modeling and data assimilation framework known as the Land Information System (LIS), it also supports hydrological data products from other, non-LIS environments. In addition, the analysis of diagnostics from various computational subsystems of LIS including data assimilation, optimization and uncertainty estimation are supported within LVT. Together, LIS and LVT provide a robust end-to-end environment for enabling the concepts of model data fusion for hydrological applications. The evolving capabilities of LVT framework are expected to facilitate rapid model evaluation efforts and aid the definition and refinement of formal evaluation procedures for the land surface modeling community.

Kumar, Sujay V.↗

Extracting Olivine (Fo-Fa) Compositions from Raman Spectral Peak Positions

Olivine and pyroxene are two major basaltic minerals that have been identified at Gusev Crater and Meridiani Planum by the Mars Exploration Rovers. Full petrologic characterization of a sample (rock or soil), however, requires determining the range of mineral compositions, extent of zoning, range of grain sizes, mineral associations, presence of xenocrysts, etc. Information of this sort will aid the interpretation of sample crystallization and differentiation histories and help discriminate between lithologies. In Raman spectroscopic experiments, minerals are identified by their spectral patterns and mineral compositions can be inferred from the peak positions. Instruments currently in use or slated for impending surface exploration missions provide only average elemental compositions for relatively large rock or soil targets or bulk mineral analysis. No techniques currently in use or scheduled for flight can characterize both structure and composition of individual mineral grains, in-situ, like the Mars Microbeam Raman Spectrometer (MMRS). The MMRS is designed to take 100 spectra along a 1 cm linear traverse on the surface of a sample, with contributions from one or a few mineral phases per spectrum. We presented a method to extract structural and compositional information from the Raman spectra of quadrilateral pyroxenes. The pyroxene calibration was applied to a Raman spectroscopic study of Martian meteorite EETA79001 along with a preliminary olivine calibration, where we demonstrated the capability to discriminate related lithologies using Raman point counts. This paper presents an improved olivine calibration that will further aid sample characterization and the study of alteration processes.

Kuebler, K.↗

In situ XRF and gamma ray spectrometer for Mars sample return mission

A combined in situ X-ray fluorescence (XRF) and passive gamma ray spectrometer instrument is proposed for the chemical elemental analysis of various Martian surfaces and samples. The combined instrument can be carried on board a rover. The passive gamma ray or the neutron excited gamma ray system would be used to determine the elemental composition of the Martian surface while the rover is in motion. The XRF system would be used to perform analysis either on the Martian surface or on collected samples when the rover is stationary. The latter function is important both in cataloging the collected samples and in the selection of samples to be returned to earth. For both systems, data accumulation time would be on the order of 30 minutes. No sample preparation would be necessary.

Lo, I. Yin↗

In situ extraction and analysis of volatile elements and molecules from carbonaceous chondrites

A laser microprobe mass spectrometer was used to measure volatiles released, on a scale of 30-50 microns, from freshly broken, sawed, and weathered surfaces in fragments of the Allende, Murchison, Coolidge, Felix, and Orgueil carbonaceous chondrites. Samples were heated to about 120 C under a vacuum of 200 ntorr and illuminated with the focused beam of a Q-switched Nd:glass laser of variable energy output (0.1-1.0 J); the gases released were analyzed using a computer-controlled mass-selective detector. The results are presented in tables and graphs and discussed in detail, with particular attention to aqueous alteration; weathering; thermal metamorphism; the distribution of sulfur-bearing phases; and differences in the amounts of volatiles in matrix, inclusions, and chondrules.

Hartmetz, C. P.↗