Search NASA⌕ Search

SEARCH · Search NASA

Results for “Infrared absorption spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Molecular line parameters for the atmospheric trace molecule spectroscopy experiment

During its first mission in 1985 onboard Spacelab 3, the ATMOS (atmospheric trace molecule spectroscopy) instrument, a high speed Fourier transform spectrometer, produced a large number of high resolution infrared solar absorption spectra recorded in the occultation mode. The analysis and interpretation of these data in terms of composition, chemistry, and dynamics of the earth's upper atmosphere required good knowledge of the molecular line parameters for those species giving rise to the absorptions in the atmospheric spectra. This paper describes the spectroscopic line parameter database compiled for the ATMOS experiment and referenced in other papers describing ATMOS results. With over 400,000 entries, the linelist catalogs parameters of 46 minor and trace species in the 1-10,000/cm region.

Brown, L. R.↗

Far-IR Measurements at Cerro Toco, Chile: FIRST, REFIR, and AERI

In mid-2009, the Radiative Heating in the Underexplored Bands Campaign II (RHUBC-II) was conducted from Cerro Toco, Chile, a high, dry, remote mountain plateau, 23degS , 67.8degW at 5.4km, in the Atacama Desert of Northern Chile. From this site, dominant IR water vapor absorption bands and continuum, saturated when viewed from the surface at lower altitudes, or in less dry locales, were investigated in detail, elucidating IR absorption and emission in the atmosphere. Three FTIR instruments were at the site, the Far-Infrared Spectroscopy of the Troposphere (FIRST), the Radiation Explorer in the Far Infrared (REFIR), and the Atmospheric Emitted Radiance Interferometer (AERI). In a side-by-side comparison, these measured atmospheric downwelling radiation, with overlapping spectral coverage from 5 to100um (2000 to 100/cm), and instrument spectral resolutions from 0.5 to 0.64/cm, unapodized. In addition to the FTIR and other ground-based IR and microwave instrumentation, pressure/temperature/relative humidity measuring sondes, for atmospheric profiles to 18km, were launched from the site several times a day. The derived water vapor profiles, determined at times matching the FTIR measurement times, were used to model atmospheric radiative transfer. Comparison of instrument data, all at the same spectral resolution, and model calculations, are presented along with a technique for determining adjustments to line-by-line calculation continuum models. This was a major objective of the campaign.

Cageao, Richard P.↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗

Heterodyne spectroscopy of astronomical and laboratory sources at 8.5 microns using diode laser local oscillators

The first 8.5 microns infrared heterodyne spectrometer has been constructed using tuneable semiconductor (PbSe) diode lasers and was used to measure absorption line profiles of N2O in the laboratory, as well as black-body emission from the moon and from Mars. Spectral information was recorded over a 200 MHz bandwidth using an 8-channel filter bank. The resolution was 25 MHz (6 millionths of a micron), and the minimum detectable (black-body) power was approximately 1 times 10 to the minus 16th power W for 8 min of integration. The results demonstrate the usefulness of heterodyne spectroscopy for the study of remote and local sources in the infrared.

Mumma, M.↗

Composition of the Martian aerosols through near-IR spectroscopy

Near-infrared spectroscopy is a powerful technique to study the composition of planetary surfaces, as the main minerals exhibit absorption bands in this spectral range. It gave important information on the mineralogy and petrology of Mars in the past twenty years although in this case it is well known that a large fraction of light is scattered by the airborne particles before reaching the surface. The measured signal is thus the sum of two different contributions that should be studied separately: One from the surface and one from the aerosols that depends on their density, size distribution and composition. Data from the ISM imaging spectrometer are used here to derive the aerosols spectrum. They consist in sets of spectra (from 0.76 to 3.16 microns) of approximately 3000 pixels approximately 25x25 sq km in size. The resulting spectrum exhibits both water-ice and clay mineral features superimposed on a scattering continuum.

Erard, Stephane↗

InGaAsSb/AlGaAsSb Heterojunction Phototransistors for Infrared Applications

High quality infrared (IR) quantum detectors are important for several applications, such as atmospheric remote sensing, chemical detection and absorption spectroscopy. Although several IR detectors are commercially available, with different materials and structures, they provide limited performance regarding the signal-to-noise ratio and the corresponding minimum detectable signal. InGaAsSb/AlGaAsSb heterojunction based phototransistors show strong potential for developing IR sensors with improved performance. In this paper, the performance of a novel npn InGaAsSb/AlGaAsSb heterojunction phototransistor is presented. This performance study is based on experimental characterization of the device dark current, noise and spectral response. Detectivity of 1.7x10(exp 9) cmHz(exp 1/2)/W at 2 microns was obtained at 100 C temperature and 2 V bias voltage. This corresponds to a responsivity of 94.7 A/W and an internal gain of 156 with about 37.7% quantum efficiency. Reducing the temperature to -30 C allows to increase the bias to 3V and enhance the detectivity to 8.7x10(exp 10) cmHz(exp 1/2)/W at the same wavelength, which corresponds to a responsivity of 386.5 A/W and an internal gain of 288.2 with about 83.3% quantum efficiency. The device impulse response and linearity, including the corresponding dynamic range, also are presented. Impulse response analysis indicated a settling time of about 1.1 s at 2V and 100 C, while linearity measurements indicated a constant responsivity in the radiation intensity range of 1.6x10(exp -7) W/sq cm and 31.6 mW/sq cm.

Refaat, Tamer F.↗

High resolution atmospheric spectroscopy using a diode laser heterodyne spectrometer

Ultrahigh resolution (0.007 per cm) atmospheric solar absorption spectra that have been obtained from a tunable infrared heterodyne radiometer are discussed. The radiometer was developed for ground based observations in the 8-12 micron region, and tunability is achieved through the use of Pb-salt semiconductor laser local oscillators. Spectra have been obtained in a piecewise fashion from 9.1 to 11.1 microns using laser emission modes that exhibit characteristics suitable for local-oscillator operation. Spectra showing absorption features of HNO3, O3, CO2, and H2O are presented along with comparisons of experimental and synthetic spectra calculated using a line-by-line atmospheric transmission model.

Hoell, J. M., Jr.↗

The C9 cluster - Structure and infrared frequencies

A structural characterization is presented for C9, the largest cluster predicted to have a linear ground state. IR laser diode absorption spectroscopy of a supersonic carbon jet is used to measure 51 lines of the nu6 (sigma u) antisymmetric stretch fundamental transition within the linear 1Sigma(g)+ ground electronic state of C9. The measured ground state rotational constant suggests an effective C-C bond length which is in good agreement with ab initio theory and consistent with cumulenic bonding in this cluster.

Heath, J. R.↗

'Diamondlike' carbon films - Optical absorption, dielectric properties, and hardness dependence on deposition parameters

An RF plasma deposition system was used to prepare amorphous 'diamondlike' carbon films. The source gases for the RF system include methane, ethylene, propane, and propylene, and the parameters varied were power, dc substrate bias, and postdeposition anneal temperature. Films were deposited on various substrates. The main diagnostics were optical absorption in the visible and in the infrared, admittance as a function of frequency, hardness, and Auger and ESCA spectroscopy. Band gap is found to depend strongly on RF power level and band gaps up to 2.7 eV and hardness up to 7 Mohs were found. There appears to be an inverse relationship between hardness and optical band gap.

Natarajan, V.↗

Tunable Electro-optic modulators for lidar systems and atmospheric applications

In global sensing applications using different types of lidars, the spectral range and fine frequency coverages are often limited because of the finite tunabilities of molecular lasers and the number of molecular species that are available. To overcome the above obstacle, we have proposed new broadband frequency tunable electro-optic (EO) modulators that can cover a wide range from the mid-infrared to the visible as lidar sources in atmospheric sensing applications such as high resolution atmospheric molecular spectroscopy, Differential Absorption Lidar (DIAL), and laser radar imaging. The configuration of the proposed new tunable EO modulators includes an electro-optic active crystal element surrounded by a ferrite tuning element which is placed inside a microwave waveguide. The tuning is provided by an external magnetic field, which is either longitudinal or transverse, and the modulator can be either single sideband type or a double sideband type depending on the application required for the spectral purity of the modulator output.

Eng, R. S.↗

Methane concentration and isotopic composition measurements with a mid-infrared quantum-cascade laser

A quantum-cascade laser operating at a wavelength of 8.1 micrometers was used for high-sensitivity absorption spectroscopy of methane (CH4). The laser frequency was continuously scanned with current over more than 3 cm-1, and absorption spectra of the CH4 nu 4 P branch were recorded. The measured laser linewidth was 50 MHz. A CH4 concentration of 15.6 parts in 10(6) ( ppm) in 50 Torr of air was measured in a 43-cm path length with +/- 0.5-ppm accuracy when the signal was averaged over 400 scans. The minimum detectable absorption in such direct absorption measurements is estimated to be 1.1 x 10(-4). The content of 13CH4 and CH3D species in a CH4 sample was determined.

Non-NASA Center↗

Design Through Integration of On-Board Calibration Device with Imaging Spectroscopy Instruments

The main purpose of the Airborne Visible and Infrared Imaging Spectroscopy (AVIRIS) project is to "identify, measure, and monitor constituents of the Earth's surface and atmosphere based on molecular absorption and particle scattering signatures." The project designs, builds, and tests various imaging spectroscopy instruments that use On-Board Calibration devices (OBC) to check the accuracy of the data collected by the spectrometers. The imaging instrument records the spectral signatures of light collected during flight. To verify the data is correct, the OBC shines light which is collected by the imaging spectrometer and compared against previous calibration data to track spectral response changes in the instrument. The spectral data has the calibration applied to it based on the readings from the OBC data in order to ensure accuracy.

imaging spectroscopy↗

Detection of carbonyl fluoride in the stratosphere

Infrared solar absorption spectra of the stratosphere recorded at a resolution of 0.01/cm by the ATMOS (Atmospheric Trace Molecule Spectroscopy) instrument from onboard Spacelab 3 (04/30 to 05/6/85) have revealed the existence of many previously unobserved absorption features in the 1925 to 1960/cm and 1249 to 1255/cm regions and one at 774/cm. On the basis of comparisons with laboratory spectra, these features have been identified as belonging to the nu1, nu4, and nu6 bands of carbonyl fluoride, respectively. Volume mixing ratios of COF2 between 17 and 40 km have been deduced from analysis of the nu1 and nu6 bands.

Rinsland, C. P.↗

Mineral composition of Al-rich float rocks in Jezero crater as seen by Super-Cam

During its traverse across the Jezero crater floor and western fan, the Perseverance rover encountered > 4000 float rocks – of variable size (up to ~ 50 cm) scattered on the ground without apparent connection to the surrounding stratigraphy [1]. Analysis performed using the SuperCam instrument’s [2,3,4], Laser Induced Breakdown Spectroscopy (LIBS) revealed a high concentration of Al 2 O 3 , Cr, Ti and Ni [5], and very low of Fe, Mg, Ca and Na [5, 1]. SuperCam’s infrared reflectance spectroscopy (IRS, between 1.3 and 2.6 μm) showed the presence of Al-rich aqueous alteration minerals (characteristic absorption bands of kaolinite and Al-smectites at 1.4 and 2.2 μm) as well as some (likely Cr-) spinels, identified uthrough their broad asymmetric 2 μm band, responsible for the concavity of IR spectra. These mineral species alone do not fully account for the spectral shapes; hence, the objective is to further investigate spectral modeling to determine the most probable mineral assemblages. Here, we present the results of modeling 17 light-toned float rocks, up to Sol 924, complementary to [1].

C. Royer↗

Investigating Si Bonding Environments in Mercurian Melts

Mercury’s low oxygen fugacity results in lavas with extraordinarily high sulfur contents (> 1 wt%). The high S lowers melt viscosity, but why this occurs is unclear (Mouser et al., 2021). The detection of Si-S bonds (using NMR) in such highly reduced basaltic glasses, suggest that the decreased viscosity is due to changes in the Si bonding environment (Pommier et al., 2023). To investigate further, we synthesized a series of Mercurian glasses at 1 GPa, with S contents ranging from 0-6 wt% and oxygen fugacities from IW-4 to IW-6. The experimental glasses were analyzed by Si K-edge X-ray Absorption Near Edge Structure (XANES) spectroscopy and 29Si Nuclear Magnetic Resonance (NMR). Ongoing analyses will include Raman and Fourier Transform Infrared (FTIR). The 29Si NMR analyses suggest the presence of Si-S bonds in the melts, in agreement with Pommier et al. (2023). The Si K-edge XANES spectra show a decrease in K-edge position of 0.4 to 0.6 eV from terrestrial basalts (at ~IW+3) to the experimental melts at IW-4 to IW-6. This shift suggests a moderate (<20 mole %) amount of Si has shifted to lower valence states (Boujibar et al, 2019). The melts contain 0-6 wt% S, so if the K-edge shifts are the results of Si-S bonding, it implies that the majority of the S in the melts is bonded to Si. However, S K-edge XANES analyses indicate that much of the S is also bonded with Mg and Ca at these low oxygen fugacities (Anzures et al, 2020). The implication is that non-bridging Si-S-(Mg,Ca) bonds are prevalent in the reduced melts, consistent with the decrease in viscosity of the melts being due to melt depolymerization. Overall, our results suggest that dissolution of S into the melts at low fO2 is accomplished through bonding with Si, and is accompanied by significant structural changes that lower melt viscosity. Lower melt viscosities will affect many aspects of Mercury’s evolution, from magma ocean dynamics, to melt migration in the mantle, to eruption dynamics and degassing.

Emily L Fischer↗

Study of dynamic emission spectra from lubricant films in an elastohydrodynamic contact using Fourier transform spectroscopy

Infrared emission spectra were obtained through a diamond window from lubricating fluids in an operating sliding elastohydrodynamic contact and analyzed by comparison with static absorption spectra under similar pressures. Different loads, shear rates and temperatures were used. Most of the spectra exhibited polarization characteristics, indicating directional alignment of the lubricant in the EHD contact. Among the fluids studied were a "traction" fluid, an advanced ester, and their mixtures, a synthetic paraffin, a naphthenic reference fluid (N-1), both neat and containing 1 percent of p-tricresyl phosphate as an anti-wear additive, and a C-ether. Traction properties were found to be nearly proportional to mixture composition for traction fluid and ester mixtures. The anti-wear additive reduced traction and fluid temperature under low loads but increased them under higher loads, giving rise to formation of a friction polymer.

Lauer, J. L.↗

Infrared spectroscopy of homogeneously nucleated hydrazine aerosols - Disordered and crystalline phases

It is shown that aerosols generated at low temperatures and high condensation rate spontaneously form in a highly crystalline state. The resonant absorption bands in the IR spectra of these highly crystalline particles are much sharper than any reported previously in the bulk, and reveal details in the N-H vibrational bands that have not been previously observed. A disordered phase is also observed at somewhat higher temperatures. These results are consistent with this being a supercooled liquid. The fact that the spectra associated with these two aerosol phases are quite different is important to any future attempts at detecting hydrazine aerosols in planetary atmospheres by remote sensing techniques.

Dunder, T.↗