Search NASASearch

SEARCH · Search NASA

Results for “Infrared light”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A Miniaturized Video System for Monitoring Drosophila Behavior

Long-term spaceflight may induce a variety of harmful effects in astronauts, resulting in altered motor and cognitive behavior. The stresses experienced by humans in space - most significantly weightlessness (microgravity) and cosmic radiation - are difficult to accurately simulate on Earth. In fact, prolonged and concomitant exposure to microgravity and cosmic radiation can only be studied in space. Behavioral studies in space have focused on model organisms, including Drosophila melanogaster. Drosophila is often used due to its short life span and generational cycle, small size, and ease of maintenance. Additionally, the well-characterized genetics of Drosophila behavior on Earth can be applied to the analysis of results from spaceflights, provided that the behavior in space is accurately recorded. In 2001, the BioExplorer project introduced a low-cost option for researchers: the small satellite. While this approach enabled multiple inexpensive launches of biological experiments, it also imposed stringent restrictions on the monitoring systems in terms of size, mass, data bandwidth, and power consumption. Suggested parameters for size are on the order of 100 mm3 and 1 kg mass for the entire payload. For Drosophila behavioral studies, these engineering requirements are not met by commercially available systems. One system that does meet many requirements for behavioral studies in space is the actimeter. Actimeters use infrared light gates to track the number of times a fly crosses a boundary within a small container (3x3x40 mm). Unfortunately, the apparatus needed to monitor several flies at once would be larger than the capacity of the small satellite. A system is presented, which expands on the actimeter approach to achieve a highly compact, low-power, ultra-low bandwidth solution for simultaneous monitoring of the behavior of multiple flies in space. This also provides a simple, inexpensive alternative to the current systems for monitoring Drosophila populations in terrestrial experiments, and could be especially useful in field experiments in remote locations. Two practical limitations of the system should be noted: first, only walking flies can be observed - not flying - and second, although it enables population studies, tracking individual flies within the population is not currently possible. The system used video recording and an analog circuit to extract the average light changes as a function of time. Flies were held in a 5-cm diameter Petri dish and illuminated from below by a uniform light source. A miniature, monochrome CMOS (complementary metal-oxide semiconductor) video camera imaged the flies. This camera had automatic gain control, and this did not affect system performance. The camera was positioned 5-7 cm above the Petri dish such that the imaging area was 2.25 sq cm. With this basic setup, still images and continuous video of 15 flies at one time were obtained. To reduce the required data bandwidth by several orders of magnitude, a band-pass filter (0.3-10 Hz) circuit compressed the video signal and extracted changes in image luminance over time. The raw activity signal output of this circuit was recorded on a computer and digitally processed to extract the fly movement "events" from the waveform. These events corresponded to flies entering and leaving the image and were used for extracting activity parameters such as inter-event duration. The efficacy of the system in quantifying locomotor activity was evaluated by varying environmental temperature, then measuring the activity level of the flies.

Bhattacharya, Sharmila

Multispectral Scanner for Monitoring Plants

A multispectral scanner has been adapted to capture spectral images of living plants under various types of illumination for purposes of monitoring the health of, or monitoring the transfer of genes into, the plants. In a health-monitoring application, the plants are illuminated with full-spectrum visible and near infrared light and the scanner is used to acquire a reflected-light spectral signature known to be indicative of the health of the plants. In a gene-transfer- monitoring application, the plants are illuminated with blue or ultraviolet light and the scanner is used to capture fluorescence images from a green fluorescent protein (GFP) that is expressed as result of the gene transfer. The choice of wavelength of the illumination and the wavelength of the fluorescence to be monitored depends on the specific GFP.

Gat, Nahum

Nanolaminate Mirrors With "Piston" Figure-Control Actuators

Efforts are under way to develop a special class of thin-shell curved mirrors for high-resolution imaging in visible and infrared light in a variety of terrestrial or extraterrestrial applications. These mirrors can have diameters of the order of a meter and include metallic film reflectors on nanolaminate substrates supported by multiple distributed piezoceramic gpiston h-type actuators for micron-level figure control. Whereas conventional glass mirrors of equivalent size and precision have areal mass densities between 50 and 150 kg/sq m, the nanolaminate mirrors, including not only the reflector/ shell portions but also the actuators and the backing structures needed to react the actuation forces, would have areal mass densities that may approach .5 kg/m2. Moreover, whereas fabrication of a conventional glass mirror of equivalent precision takes several years, the reflector/shell portion of a nanolaminate mirror can be fabricated in less than a week, and its actuation system can be fabricated in 1 to 2 months. The engineering of these mirrors involves a fusion of the technological heritage of multisegmented adaptive optics and deformable mirrors with more recent advances in metallic nanolaminates and in mathematical modeling of the deflections of thin, curved shells in response to displacements by multiple, distributed actuators. Because a nanolaminate shell is of the order of 10 times as strong as an otherwise identical shell made of a single, high-strength, non-nanolaminate metal suitable for mirror use, a nanolaminate mirror can be made very thin (typically between 100 and 150 m from the back of the nanolaminate substrate to the front reflecting surface). The thinness and strength of the nanolaminate are what make it possible to use distributed gpiston h-type actuators for surface figure control with minimal local concentrated distortion (called print-through in the art) at the actuation points.

Lowman, Andrew

Optical Coating Performance for Heat Reflectors of the JWST-ISIM Electronic Component

A document discusses a thermal radiator design consisting of lightweight composite materials and low-emittance metal coatings for use on the James Webb Space Telescope (JWST) structure. The structure will have a Thermal Subsystem unit to provide passive cooling to the Integrated Science Instrument Module (ISIM) control electronics. The ISIM, in the JWST observatory, is the platform that provides the mounting surfaces for the instrument control electronics. Dissipating the control electronic generated-heat away from JWST is of paramount importance so that the spacecraft s own heat does not interfere with the infrared-light gathering of distant cosmic sources. The need to have lateral control in the emission direction of the IEC (ISIM Electronics Compartment) radiators led to the development of a directional baffle design that uses multiple curved mirrorlike surfaces. This concept started out from the so-called Winston non-imaging optical concentrators that use opposing parabolic reflector surfaces, where each parabola has its focus at the opposite edge of the exit aperture. For this reason they are often known as compound parabolic concentrators or CPCs. This radiator system with the circular section was chosen for the IEC reflectors because it offers two advantages over other designs. The first is that the area of the reflector strips for a given radiator area is less, which results in a lower mass baffle assembly. Secondly, the fraction of energy emitted by the radiator strips and subsequently reflected by the baffle is less. These fewer reflections reduced the amount of energy that is absorbed and eventually re-emitted, typically in a direction outside the design emission range angle. A baffle frame holds the mirrors in position above a radiator panel on the IEC. Together, these will direct the majority of the heat from the IEC above the sunshield away towards empty space.

Rashford, Robert A.

Subaru Imaging of Asymmetric Features in a Transitional Disk in Upper Scorpius

We report high-resolution (0.07 arcsec) near-infrared polarized intensity images of the circumstellar disk around the star 2MASS J16042165.2130284 obtained with HiCIAO mounted on the Subaru 8.2 m telescope. We present our H-band data, which clearly exhibit a resolved, face-on disk with a large inner hole for the first time at infrared wavelengths. We detect the centrosymmetric polarization pattern in the circumstellar material as has been observed in other disks. Elliptical fitting gives the semi-major axis, semi-minor axis, and position angle (P.A.) of the disk as 63 AU, 62 AU, and -14deg, respectively. The disk is asymmetric, with one dip located at P.A.s of approx. 85deg. Our observed disk size agrees well with a previous study of dust and CO emission at submillimeter wavelength with Submillimeter Array. Hence, the near-infrared light is interpreted as scattered light reflected from the inner edge of the disk. Our observations also detect an elongated arc (50 AU) extending over the disk inner hole. It emanates at the inner edge of the western side of the disk, extending inward first, then curving to the northeast. We discuss the possibility that the inner hole, the dip, and the arc that we have observed may be related to the existence of unseen bodies within the disk.

Mayama, S.

Subaru Imaging of Asymmetric Features in a Transitional Disk in a Transitional Disk in Upper Scorpius

We report high-resolution (0.07 arcsec) near-infrared polarized intensity images of the circumstellar disk around the star 2MASS J16042165−2130284 obtained with HiCIAO mounted on the Subaru 8.2 m telescope. We present our H-band data, which clearly exhibit a resolved, face-on disk with a large inner hole for the first time at infrared wavelengths.We detect the centrosymmetric polarization pattern in the circumstellar material as has been observed in other disks. Elliptical fitting gives the semimajor axis, semiminor axis, and position angle (P.A.) of the disk as 63 AU, 62 AU, and −14◦, respectively. The disk is asymmetric, with one dip located at P.A.s of ∼85◦. Our observed disk size agrees well with a previous study of dust and CO emission at submillimeter wavelength with Submillimeter Array. Hence, the near-infrared light is interpreted as scattered light reflected from the inner edge of the disk. Our observations also detect an elongated arc (50 AU) extending over the disk inner hole. It emanates at the inner edge of the western side of the disk, extending inward first, then curving to the northeast. We discuss the possibility that the inner hole, the dip, and the arc that we have observed may be related to the existence of unseen bodies within the disk

protoplanetary disks

Nitrogen Dioxide Observations from the Geostationary Trace Gas and Aerosol Sensor Optimization (GeoTaso) Airborne Instrument: Retrieval Algorithm and Measurements During DISCOVER-AQ Texas 2013

The Geostationary Trace gas and Aerosol Sensor Optimization (GeoTASO) airborne instrument is a test bed for upcoming air quality satellite instruments that will measure backscattered ultraviolet, visible and near-infrared light from geostationary orbit. GeoTASO flew on the NASA Falcon aircraft in its first intensive field measurement campaign during the Deriving Information on Surface Conditions from Column and Vertically Resolved Observations Relevant to Air Quality (DISCOVER-AQ) Earth Venture Mission over Houston, Texas, in September 2013. Measurements of backscattered solar radiation between 420 and 465 nm collected on 4 days during the campaign are used to determine slant column amounts of NO2 at 250 m x 250 m spatial resolution with a fitting precision of 2.2 x 10(exp 15) molecules/sq cm. These slant columns are converted to tropospheric NO2 vertical columns using a radiative transfer model and trace gas profiles from the Community Multiscale Air Quality (CMAQ) model. Total column NO2 from GeoTASO is well correlated with ground-based Pandora observations (r = 0.90 on the most polluted and cloud-free day of measurements and r = 0.74 overall), with GeoTASO NO2 slightly higher for the most polluted observations. Surface NO2 mixing ratios inferred from GeoTASO using the CMAQ model show good correlation with NO2 measured in situ at the surface during the campaign (r = 0.85). NO2 slant columns from GeoTASO also agree well with preliminary retrievals from the GEO-CAPE Airborne Simulator (GCAS) which flew on the NASA King Air B200 (r = 0.81, slope = 0.91). Enhanced NO2 is resolvable over areas of traffic NOx emissions and near individual petrochemical facilities.

Aerosol Sensor Optimization

Growth Curve Parameterization of Metabolic Activity of Yeast Cells for BioSentinel

The goal of the BioSentinel small satellite payload is to measure the effect of deep space radiation on the growth and metabolic activity of yeast cells. Raw test data is generated by fluidics cards containing yeast cells rehydrated at different periods, with metabolic activity measured by the reduction of alamarBlue. Each card well has a sensor array that measures the amount of red, green, and infrared light transmitted through the yeast culture. This illumination data is then converted to absorbance values, which are further converted into concentrations. The ultimate objective is to convert these concentrations into biologically-relevant metrics that can be compared against one another to determine changes due to differential radiation exposure. Beginning with IR absorbance data (corresponding to cell density) from ground studies, three parameters from a sigmoidal growth curve were extracted and analyzed: 𝜆 (lag phase), 𝜇 (max growth rate), and A (max cell growth). The data was fit to the Gompertz model of microbial growth using non-linear regression (Minitab), as the fit error was reduced compared to the simpler logistic growth curve. Graphs showed that the data contained a discrepancy (drift) in the lag phase that is attributable to a slow, constant loss of moisture. Correcting this discrepancy by fitting the first 25 hours of the data to a power function and subtracting these values from the absorbance readings obtained a better statistical fit to the growth curve in the lag phase. A power fit was selected over a linear fit because it reflected the effects of constant volume loss. This correction to the BioSentinel data analysis pipeline will enable quantitative statistical analysis of the effect of different levels of deep space radiation on yeast cells. Future work includes automation of drift correction and curve modeling to extract these parameters directly from data.

Growth Curve

Estimating the Rate of Growth or Shrinkage of the Amundsen Crater PSR Area

Permanently shadowed regions (PSRs) contain some areas [Figure 1] where frozen volatiles can be observed at the lunar poles. They have maximum surface temperatures < 100 K [1, 2]. Surface temperatures in these shadowed regions are largely controlled by reflected sunlight and irradiated infrared light from adjacent topography [3-6]. These areas are cold traps, capable of accumulating water and other volatile compounds over time [7]. There is a lack of understanding regarding the surface thermal changes at these PSRs, particularly how these pockets of < 100 K temperatures change on a yearly basis and may inhibit growth or shrinkage of volatile accumulation or ablation, respectively. Here, we measure the bolometric temperatures derived from Diviner over several years (2010-2016).

C J Ahrens

The Webb Space Telescope - An Engineering Marvel Story

This presentation will provide an overview of the James Webb Space Telescope (JWST) and its engineering development process. JWST has succeeded the Hubble Space Telescope in our quest for the first galaxies formed out of the darkness of the early universe. Since its launch in December 2021, JWST has helped us understand how these galaxies evolved over billions of years, how stars and planetary systems form, what exoplanets look like and if they can harbor life. JWST uses a ~6.5-m-diameter primary mirror to collect infrared light, which is sent to four scientific instruments. It operates at the second Sun-Earth Lagrange point and has a five-layer sunshield to be able to operate at cryogenic temperatures. JWST is an international effort of NASA and the European and Canadian Space Agencies.

James Webb Space Telescope

High Efficiency Near Infrared Spectrometer for Zodiacal Light Spectral Study

We are developing a near infrared spectrometer for measuring solar absorption lines in the zodiacal light in the near infrared region. R. Reynolds at el. (2004, ApJ 61 2, 1206) demonstrated that observing single Fraunhofer line can be a powerful tool for extracting zodiacal light parameters based on their measurements of the profile of the Mg I l~neat 5 184 A. We are extending this technique to the near infrared with the primary goal of measuring the absolute intensity of the zodiacal light. This measurement will provide the crucial information needed to accurately subtract zodiacal emission from the DIRBE measurements to get a much higher quality measurement of the extragalactic IR background. The instrument design is based on a dual Fabry-Perot interferometer with a narrow band filter. Its double etalon design allows to achieve high spectral contrast to reject the bright out of band telluric OH emission. High spectral contrast is absolutely necessary to achieve detection limits needed to accurately measure the intensity of the absorption line. We present the design, estimated performance of the instrument with the expected results of the observing program.

Kutyrea, A. S.

The Use of NASA Light-Emitting Diode Near-Infrared Technology for Biostimulation

Studies on cells exposed to microgravity and hypergravity indicate that human cells need gravity to stimulate growth. As the gravitational force increases or decreases, the cell function responds in a linear fashion. This poses significant health risks for astronauts in long-term spaceflight. The application of light therapy with the use of NASA LEDs will significantly improve the medical care that is available to astronauts on long-term space missions. NASA LEDs stimulate the basic energy processes in the mitochondria (energy compartments) of each cell, particularly when near-infrared light is used to activate the color sensitive chemicals (chromophores, cytochrome systems) inside. Optimal LED wavelengths include 680, 730 and 880 nm and our laboratory has improved the healing of wounds in laboratory animals by using both NASA LED light and hyperbaric oxygen. Furthermore, DNA synthesis in fibroblasts and muscle cells has been quintupled using NASA LED light alone, in a single application combining 680, 730 and 880 nm each at 4 Joules per centimeter squared. Muscle and bone atrophy are well documented in astronauts, and various minor injuries occurring in space have been reported not to heal until landing on Earth. An LED blanket device may be used for the prevention of bone and muscle atrophy in astronauts. The depth of near-infrared light penetration into human tissue has been measured spectroscopically.

Whelan, Harry T.

Carrier suppression device for a heterodyne gas analyzer

Analyzer operates with broadband light from blackbody infrared source. Light is passed sequentially through two gas-filled chambers to suitable infrared detector while pressures in gas-filled chambers are modulated in sinusoidal manner. Because pressure of infrared-absorbing gases in chambers is modulated, amount of light absorbed by gases is also modulated.

Mcclatchie, E. A.

Stray light in the Infrared Astronomical Satellite (IRAS)

Changes made to the telescope and critical objects considered in modeling these changes into the APART program are described. The optical system was analyzed for scattered light, diffracted then scattered radiation, and thermally emitted radiation. The damaged area of the primary to mirror was also examined. Results are presented in tables and graphs.

Lange, S. R.

Optical Coupling Mechnisms in Quantum Well Infrared Photodetectors

Light coupling systems, such as gratings are required becuase Quantum Well Infrared Photodetectors do not respond to normal incident light due to the quantum mechanical selection rules associated with intersubband transitions. The resolution of the photolithography and acuracy of the etching beomce key issues in producing smaller rating feature sizes expecially in shorter wavelengths.

Quantum Wells Intersubband infrared detectors grat

'Infrared cirrus' - New light on the interstellar medium

The observational data on 'infared cirrus', considered here to be emission from tenuous dust clouds scattered throughout the ISM, are reviewed. The morphology of individual clouds and of the global distribution of infared cirrus is addressed, as well as the energy distribution. Some of the implications of the results for the ISM are summarized, and prospects for future cirrus measurements are briefly addressed.

Hauser, Michael G.

The optical and near-infrared distribution of light in the edge-on galaxy IC 2531

Optical and near-IR imaging of the edge-on galaxy IC 2531 is presented, and an attempt is made to derive the true distributions of stars and dust in this galaxy. The results suggest that the z dependence of the light distribution is better fitted by an exponential than by the isothermal sech-squared distribution. The dynamical implication of such a distribution is that the vertical velocity dispersion near the galactic plane should increase with z. A simple model for the light and dust distribution in IC 2531 employing three exponential components is constructed: an old disk, a young disk, and dust. Vertical scale heights of h(zd) = h(z)/4 and h(zy) = h(z)/8 and an absorption equivalent to about half of that in the Galaxy are found to produce the best fits.

Wainscoat, R. J.