Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrument”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Changing-look Active Galactic Nuclei from the Dark Energy Spectroscopic Instrument. II. Statistical Properties from the First Data Release

We present the identification of changing-look active galactic nuclei (CL-AGNs) from the Dark Energy Spectroscopic Instrument First Data Release and Sloan Digital Sky Survey Data Release 16 at z≤ 0.9. To confirm the CL-AGNs, we utilize spectral flux calibration assessment via an [O iii]-based calibration, pseudophotometry examination, and visual inspection. This rigorous selection process allows us to compile a statistical catalog of 561 CL-AGNs, encompassing 527 Hβ, 149 Hα, and 129 Mg ii CL behaviors. In this sample, we find (1) a 283:278 ratio of turn-on to turn-off CL-AGNs. (2) The median Eddington ratio for CL-AGNs in the dim state is approximately λ$_{Edd}$ ∼ 0.01. (3) A strong correlation between the change in the luminosity of the broad emission lines (BELs) and variation in the continuum luminosity, with Mg ii and Hβ displaying similar responses during CL phases. (4) The Baldwin–Phillips–Terlevich diagram for CL-AGNs shows no statistical difference from the general AGN catalog. (5) Five CL-AGNs are associated with asymmetrical mid-infrared flares, possibly linked to tidal disruption events. Given the large CL-AGN sample and the stochastic sampling of spectra, we propose that some CL phenomena are inherently due to typical AGN variability during low accretion rates, particularly for CL phenomenon only occurring on one BEL. Finally, we introduce a monotonically dimming CL phase for objects characterized by a gradual decline over decades in the light curve and the complete disappearance of entire BELs in faint spectra, indicative of a real transition in the accretion disk.

79 ASTRONOMY AND ASTROPHYSICS↗

Domain Knowledge Guided Bayesian Optimization For Autonomous Alignment Of Complex Scientific Instruments

Bayesian Optimization (BO) is a powerful tool for optimizing complex non-linear systems. However, its performance degrades in high-dimensional problems with tightly coupled parameters and highly asymmetric objective landscapes, where rewards are sparse. In such needle-in-a-haystack scenarios, even advanced methods like trust-region BO (TurBO) often lead to unsatisfactory results. We propose a domain knowledge guided Bayesian Optimization approach, which leverages physical insight to fundamentally simplify the search problem by transforming coordinates to decouple input features and align the active subspaces with the primary search axes. We demonstrate this approach's efficacy on a challenging 12-dimensional, 6-crystal Split-and-Delay optical system, where conventional approaches, including standard BO, TuRBO and multi-objective BO, consistently led to unsatisfactory results. When combined with an reverse annealing exploration strategy, this approach reliably converges to the global optimum. The coordinate transformation itself is the key to this success, significantly accelerating the search by aligning input co-ordinate axes with the problem's active subspaces. As increasingly complex scientific instruments, from large telescopes to new spectrometers at X-ray Free Electron Lasers are deployed, the demand for robust high-dimensional optimization grows. Our results demonstrate a generalizable paradigm: leveraging physical insight to transform high-dimensional, coupled optimization problems into simpler representations can enable rapid and robust automated tuning for consistent high performance while still retaining current optimization algorithms.

FOS: Computer and information sciences↗

DICER: A new instrument at LANSCE to constrain neutron capture rates on radionuclides

. With very few exceptions, direct measurements of neutron capture rates on radionuclides have not been possible. A number of indirect methods have been pursued such as the surrogate method, the γ-ray strength function method, the Oslo method and the β-Oslo method. Substantial effort has been devoted to quantify the usually large systematic errors that accompany the results from these techniques. A new instrument has been developed at the Los Alamos Neutron Science Center (LANSCE) to provide more accu rate data on several radionuclides relevant to nuclear criticality safety, radiochemical diagnostics, astrophysics, nuclear forensics and nuclear security, by measuring the transmission of neutrons through radioactive samples and studying resonance properties. The Device for Indirect Capture on Radionuclides (DICER) and as sociated radionuclide production at the Isotope Production Facility (IPF), both at LANSCE, as well radioactive sample fabrication, have been under development the last few years. A description of the new apparatus, data on a few mid-weight stable isotopes and efforts on radionuclide measurements will be presented.

Nuclear Criticality Safety Program (NCSP)↗

Measurement of Parity-Violating Modes of the Dark Energy Spectroscopic Instrument (DESI) Year 1 Luminous Red Galaxies' 4-Point Correlation Function

Here we report the first measurement of the parity-violating (PV) 4-Point Correlation Function (4PCF) of the Dark Energy Spectroscopic Instrument's Year 1 Luminous Red Galaxy (DESI Y1 LRG) sample, motivated by the potential detection of the PV 4PCF in the Sloan Digital Sky Survey Baryon Oscillation Spectroscopic Survey (SDSS BOSS) galaxies. In our auto-correlation ("auto") analysis, we find a statistically significant excess of the PV signal compared to mocks without any PV, at 4-10$σ$ depending on details of the analysis. This could arise either from genuine PV or from an underestimation of the variance in the mocks; it is unlikely to arise, at the signal level, from a systematic. We then cross-correlate ("cross") the putative PV signal between different, independent patches of sky, and there find no detection of parity violation. The two measurements are in significant tension: while the cross has somewhat larger error bars than the auto, this is not sufficient to explain the discrepancy. We thus present the current work as an intriguing addition to the PV work on BOSS and as motivation for exploring further the relationship between the auto and cross PV 4PCF analyses.

Slepian, Zachary [Florida U.]↗

Redis-Based Streaming Architecture for Accelerator Beam Instrumentation DAQ Systems

The Fermilab Acceleraor Division, Beam Instrumentation Department, is always adopting modern and current software methodologies for complex DAQ architectures. This paper highlights the Redis Adapter (RA) as the key software component enabling high performance, modular communication between digitizers and distributed control systems by leveraging Redis and containerization. The RA provides a unified, efficient interface between Redis based data streams and consumer systems. In the legacy architecture, digitized data flowed through the custom, UDP based Distributed Data Communication Protocol in the middle layer. In the current system, DDCP remains the ingestion path, while the RA serves as the decoupling layer. The proposed system replaces old VME digitizers with a SOM-based digitizer that communicates with Redis using the RA. The RA acts as both a performance-critical bridge and a protocol-agnostic adapter, ensuring compatibility with legacy control frameworks while enabling future scalability and modularity. This restructuring of the middle layer also helps the system achieve high throughput, reduce latency, and simplify the data path. Finally, we will demonstrate how RA is utilized in our two core products to deliver both legacy compatibility and future flexibility.

Joshi, S. [Fermilab]↗

Modeling and simulation study for the design of the Fuel Interrogation and Examination using Submersible Tomography Analysis Mk II instrument

Here, the design of a submersible, gamma-ray tomography system for imaging irradiated nuclear fuel is described. The system—named Fuel Interrogation and Examination using Submersible Tomography Analysis (FIESTA) Mk. II—is a variation on a previous Mk. I I design, which was developed to non-destructively image fuel capsules irradiated in the Advanced Test Reactor at the Idaho National Laboratory. The FIESTA system uses a combination of transmission computed tomography and emission computed tomography to image the restructuring and fission product migration at different points of burnup. Changes made to FIESTA Mk. I reflect the revised design requirements and a need to reduce background noise, largely originating from downscattered photons from fuel and transmission source. The computational design and radiation transport simulations are described.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Ultra-pure nickel for structural components of low-radioactivity instruments

The next generation of nuclear and particle physics rare-event search experiments demand structural materials combining ultra-low levels of radioactive contamination with exceptional mechanical strength. Here, this study evaluates chemical vapor deposition (CVD) nickel as a low radioactive background candidate structural material for such applications. Manufacturer-supplied CVD Ni grown on aluminum substrates was assayed via inductively coupled plasma mass spectrometry (ICP-MS) employing isotope-dilution. These material assays produced measured bulk concentration of 232 Th, 238 U, and nat K at the levels of ~70 ppq, ≲100 ppq, and ~900 ppt, respectively, which is the lowest reported in nickel. Surface-etch profiling uncovered higher concentrations of these contaminants extending ~10 μ m beneath the surface, likely associated with the aluminum growth substrate. Additionally, the CVD Ni underwent tensile testing alongside standard Ni samples. CVD Ni exhibited a planar tensile strength of ~600 MPa, significantly surpassing standard nickel. However, heat treatment was found to reduce the tensile strength to levels comparable to standard Ni, with implications for high-temperature weld joining methods. The results reported are compared to the one other well documented usage of CVD Ni in a low radioactive background physics research experiment and a discussion is provided on how the currently reported results may arise from changes in CVD fabrication or testing process. These results establish CVD Ni as a promising low-radioactivity structural material, while outlining the need for further development in surface cleaning and weld-joining techniques to fully realize its potential in large-scale, low radioactive background rare-event search experiments.

47 OTHER INSTRUMENTATION↗