Search NASA⌕ Search

SEARCH · Search NASA

Results for “Instrumentation and Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Editorial: Resolving atmospheric flow in complex environments: recent experiments in terrain and forest canopies

The characterization of atmospheric flows in complex environments, which may include steep terrain slopes and heterogeneous vegetation and/or forest cover, is a long-standing challenge in boundary-layer meteorology. Atmospheric observations are complicated by the presence of transient, terrain-induced flow features, forest-canopy-atmosphere interactions, and atmospheric stability effects, not to mention the logistical hurdles involved with instrument deployment, data analysis, and quality control. Furthermore, challenges in atmospheric modeling arise due to numerical errors associated with complex terrain flows, as well as reliance on simplified parameterizations for unresolved processes such as turbulent mixing and land-surface or forest-canopy-atmosphere interactions. These modeling challenges are exacerbated in the so-called “gray zone,” wherein features of interest have length scales that are similar to the model grid spacing, or when the principal flow layer is smaller than the grid spacing (e.g., slope flows).

54 ENVIRONMENTAL SCIENCES↗

Walnut v1.2 Code Abstract

Abstract for publication for copyright assertion for Walnut v1.2 software code to satisfy prime contract requirements. HQ approval to assert copyright on this code was granted to NNSS on 9/30/2024

47 OTHER INSTRUMENTATION↗

MRP Review - MARVEL I&C Overview

MARVEL I&C Overview - The design and status of MARVEL I&C is discussed, along with the safety foundations that constrain and enable the design. Included are outlines of the safety-related I&C components, the non-safety-related I&C components, and the additional elements to be added after dry criticality in preparation for full power operations. Finding the path to remote operations will also be briefly discussed.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Crosstalk Effects in Microwave SQUID Multiplexed TES Bolometer Readout

Transition-edge sensor (TES) bolometers are broadly used for background-limited astrophysical measurements from the far-infrared to mm-waves. Many planned future instruments require increasingly large detector arrays, but their scalability is limited by their cryogenic readout electronics. Microwave SQUID multiplexing offers a highly capable scaling solution through the use of inherently broadband circuitry, enabling readout of hundreds to thousands of channels per microwave line. As with any multiplexing technique, the channelization mechanism gives rise to electrical crosstalk which must be understood and controlled so as to not degrade the instrument sensitivity. Here, in this study, we explore implications relevant for TES bolometer array applications, focusing in particular on upcoming mm-wave observatories such as the Simons Observatory and AliCPT. We model the relative contributions of the various underlying crosstalk mechanisms, evaluate the difference between fixed-tone and tone-tracking readout systems, and discuss ways in which crosstalk nonlinearity will complicate on-sky measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data & Code from Phoenix CPPP Phase 2 Analysis

This data and code package supports the analysis presented in “Beyond Surface Cooling: Comprehensive Field Assessment of Reflective Pavement Thermal Performance in Phoenix, Arizona” and provides fully reproducible workflows for evaluating the thermal performance of cool pavement treatments in a hot urban environment. The dataset integrates multi-modal field measurements collected across residential and nonresidential settings, including mobile air temperature traverses, stationary air temperature monitoring, residential mean radiant temperature (MRT) measurements, subsurface temperature profiles, and controlled testbed observations. The data package contains raw and processed datasets in comma-separated value (CSV) format, accompanying metadata files describing site characteristics and measurement protocols, and R scripts (.R files) used for data cleaning, time synchronization, spatial and temporal matching, quality control filtering, statistical comparison, and figure generation. All analyses were conducted using R (version ≥ 4.2.0) with commonly available packages (e.g., tidyverse, lubridate, data.table, ggplot2). No proprietary software is required to reproduce results. Field campaigns were designed to quantify the effects of high-reflectance pavement coatings on surface temperature, near-surface air temperature, subsurface heat propagation, and radiative heat exposure. Temporal alignment procedures include standardized timestamp conversion and nearest-neighbor matching of high-frequency sensor measurements to stop-based metadata within defined tolerance windows to ensure comparability across instruments. The workflows generate summary statistics, treatment–control contrasts, depth-dependent thermal gradients, and time-series visualizations used in the associated publication. By integrating mobile, stationary, radiative, and subsurface measurements within a unified and transparent processing framework, this package enables comprehensive evaluation of cool pavement performance across multiple thermal exposure pathways and supports reuse in future urban heat mitigation and climate resilience studies.

AIR TEMPERATURE↗

The NanoSIMS-HR: The Next Generation of High Spatial Resolution Dynamic SIMS

The high lateral resolution and sensitivity of the NanoSIMS 50 and 50L series of dynamic SIMS instruments have enabled numerous scientific advances over the past 25 years. Here, in this study, we report on the NanoSIMS-HR, the first major upgrade to the series, and analytical tests in a suite of sample types, including an aluminum sample containing silicon crystals, microalgae, and plant roots colonized with a symbiotic fungus. Significant improvements have been made in the Cs + ion source, high voltage (HV) control, stage reproducibility, and other aspects of the instrument that affect performance. The modified design of the NanoSIMS-HR thermal-ionization Cs + source enables a 5 pA primary ion beam to be focused into a 100 nm spot, a ~2.5-fold increase compared to Cs + sources on previous instruments (~2 pA at 100 nm). The brightness of the new Cs + source enables an ultimate lateral resolution as high as 30 nm and improved detection limits for a given analysis area. Sample stage movement accuracy is higher than 500 nm, enabling many-fold higher throughput automated analyses. With the new HV control, the primary ion beam impact energy can be reduced from 16 to 2 keV, which enables higher depth resolution during depth profiling (a 2-fold improvement), albeit with a 5-fold decrease in lateral resolution. In the NanoSIMS-HR, the secondary ion column and detection system are identical to those used in the previous series, and the isotopic analysis performance is as precise as in previous NanoSIMS instruments.

54 ENVIRONMENTAL SCIENCES↗

Employing MACS/ViBRANT as a Surrogate MARVEL Reactor for Startup Reactivity Tuning and Supervisory Control Processes

Advanced nuclear reactors are a key part of the future of nuclear energy both in the United States and globally. They offer unique benefits for various energy-demanding applications, including use in remote locations, compact size, modular manufacturing, remote monitoring, low and/or variable power rating operation, and reliance on novel technologies to enhance operational safety. To achieve economic feasibility, advanced reactors must significantly reduce their workforces in comparison with the current fleet. Achieving this reduction will occur through reducing staff workloads using technology to achieve autonomous or semi-autonomous operations, demonstrated by comprehensive testing and validation activities. These operations will require both software and hardware platforms during the design and testing phases. While simulations are useful during the design phase, their performance can significantly deviate during actual deployment on hardware. This report presents the outcomes of a collaborative technical initiative between the U.S. Department of Energy (DOE) Microreactor Program (MRP) and Advanced Sensors and Instrumentation (ASI) Program. The collaboration utilized the Microreactor Automated Control System (MACS) hardware platform to bridge the gap between theoretical reactor design and actual startup and control operations. Two key use cases were investigated: facilitating the startup testing period and demonstrating supervisory control. The first use case details the key Microreactor Applications Research Validation and Evaluation (MARVEL) reactor startup physics testing activities conducted using the MACS platform. These activities included drum worth measurements, shutdown margin assessment, temperature feedback analysis, and scram time evaluation, as well as unique testing that would apply to the MARVEL reactor to demonstrate the testing methodologies in a low-risk environment. The MACS platform, serving as a surrogate representation of the MARVEL reactor, proved instrumental in performing these tests. The exercise revealed aspects that led to optimized processes, refined hardware design, and enhanced base software capabilities. By maturing methods and technologies in this manner, the initiative promises to reduce wasted time in the actual on-site reactor deployment effort, thereby saving significant time and resources. The second use case focuses on the development and implementation of supervisory control methods aimed at managing core tilt, which can result from asymmetrical operations or manufacturing imperfections in fuel rods or reactivity control devices. A key objective was to assess and compare the use of artificial intelligence (AI) for supervisory control. The effort aimed to define the role of supervisory control to enhance performance without risking control instability. This effort explored three distinct approaches: rules-based (RB) methods, optimization techniques, and reinforcement learning (RL) algorithms. Each approach was evaluated for its ease of implementation, its usability, and its effectiveness in responding to asymmetries in neutron flux. Comparative analysis of these approaches provided valuable insights into their applicability and effectiveness, offering a robust framework for advanced reactor operations. Together, these two use cases highlight the potential of hardware test beds to help streamline the design, operation, and control of advanced nuclear reactors. This collaborative effort underscores the importance of continued innovation and experimentation in achieving the next generation of safe, reliable, and economically viable nuclear energy solutions.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

ML-based calibration and control of the GlueX Central Drift Chamber

The GlueX Central Drift Chamber (CDC) in Hall D at Jefferson Lab, used for detecting and tracking charged particles, is calibrated and controlled during data taking using a Gaussian process. The system dynamically adjusts the high voltage applied to the anode wires inside the chamber in response to changing environmental and experimental conditions such that the gain is stabilized. Control policies have been established to manage the CDC's behavior. These policies are activated when the model's uncertainty exceeds a configurable threshold or during human-initiated tests during normal production running. Finally, we demonstrate the system reduces the time detector experts dedicate to calibration of the data offline, leading to a marked decrease in computing resource usage without compromising detector performance.

47 OTHER INSTRUMENTATION↗

Experimental validation of a Kalman observer using linearized OpenFAST and a fully instrumented 1:70 model

Abstract To enable real‐time monitoring and control strategies for floating offshore wind turbines, accurate information about the state of the system is needed. This paper details the application of a Kalman filter to the UMaine VolturnUS‐S floating wind platform to provide accurate state estimates in real time using minimal system measurements. The midfidelity nonlinear simulation tool OpenFAST was used to generate the underlying linear state‐space model for the Kalman filter. This linear model and its limitations are demonstrated through comparison with experimental data collected on a 1:70 froude‐scaled model of the floating platform and tower. Using a selection of five measurements from the real system, a Kalman filter was developed to provide estimates for the remaining system states and measurements. These estimates were then validated against the experimental values collected from testing of the scale model. Validation of the Kalman filter produced accurate estimates of surge, heave, and tower base bending moment, measurements of which were not available to the Kalman filter. Performance of the Kalman filter was tested and validated over a range of sea conditions from rated wind speed to storm events and demonstrated robustness in the Kalman filter to maintain accuracy across all operating conditions despite significant error in the underlying linear model for extreme conditions.

17 WIND ENERGY↗

Comparison of Sub-Ppm Instrument Response Suggests Higher Detection Limits Could Be Used to Quantify Methane Emissions from Oil and Gas Infrastructure

Quantifying and controlling fugitive methane emissions from oil and gas facilities remains essential for addressing climate goals, but the costs associated with monitoring millions of production sites remain prohibitively expensive. Current thinking, supported by measurement and simple dispersion modelling, assumes single-digit parts-per-million instrumentation is required. To investigate instrument response, the inlets of three trace-methane (sub-ppm) analyzers were collocated on a facility designed to release gas of known composition at known flow rates between 0.4 and 5.2 kg CH 4 h –1 from simulated oil and gas infrastructure. Methane mixing ratios were measured by each instrument at 1 Hertz resolution over nine hours. While mixing ratios reported by a cavity ring-down spectrometer (CRDS)-based instrument were on average 10.0 ppm (range 1.8 to 83 ppm), a mid-infrared laser absorption spectroscopy (MIRA)-based instrument reported short-lived mixing ratios far larger than expected (range 1.8 to 779 ppm) with a similar nine-hour average to the CRDS (10.1 ppm). We suggest the peaks detected by the MIRA are likely caused by a micrometeorological phenomenon, where vortex shedding has resulted in heterogeneous methane plumes which only the MIRA can observe. Further analysis suggests an instrument like the MIRA (an optical-cavity-based instrument with cavity size ≤10 cm3 measuring at ≥2 Hz with air flow rates in the order of ≤0.3 slpm at distances of ≤20 m from the source) but with a higher detection limit (25 ppm) could detect enough of the high-concentration events to generate representative 20 min-average methane mixing ratios. Even though development of a lower-cost, high-precision, high-accuracy instrument with a 25 ppm detection threshold remains a significant problem, this has implications for the use of instrumentation with higher detection thresholds, resulting in the reduction in cost to measure methane emissions and providing a mechanism for the widespread deployment of effective leak detection and repair programs for all oil and gas infrastructure.

03 NATURAL GAS↗

Investigation of Abnormal Level Control Oscillations in a BWR Feedwater System

In the long-term operation of nuclear power plants, the aging of systems, structures, and components can lead to maintenance issues that must be dealt with to maintain cost-effective plant operations. One common issue affecting the currently operated boiling water reactors is the onset of unexpected level oscillations in feedwater heaters. This phenomenon can cause excessive cycling of drain valves and lead to premature failures. In this work, we develop a dynamic model of a set of feedwater heaters to determine the root cause of oscillations observed in an operating plant. Simulation results of various transient scenarios were used to investigate the effects of the controller parameters, boundary conditions, and possible valve and instrument issues. The analysis led to the conclusion that the most likely causes of the observed self-sustained oscillations in the system are the nonlinear behaviors of the drain valve and the level transmitter induced by degraded equipment condition. In conclusion, a partial plug of the pressure line used for level sensing in the system can account for a significant deadtime in the level transmitter, a nonlinear effect shown to induce self-sustained oscillatory behaviors.

Boiling water reactors↗

Continued Evaluation of the Use of a Raman Spectrometer for H-Canyon Dissolver Monitoring

Remote monitoring of dissolver activities in H-Canyon can help operators avoid delays associated with excessive levels of fuel fragments remaining after a run. SRNL has proposed that effective monitoring can be achieved by using a Raman spectrometer to measure NO 2 concentrations in the offgas stream sampled from the facility stack. Prior work (SRNL-STI-2021-00451) measuring the offgas from one dissolution batch of High Flux Isotope Reactor (HFIR) fuel suggested a relationship between %NO 2 levels and fragment height. Herein, we report the results of monitoring and analysis of the dissolution of four batches of Material Test Reactor (MTR) fuel. A rigorous quantitative relationship between %NO 2 measurements and fragment heights could not be established, due to high uncertainties associated with both measurements. Uncertainties with gas measurements are associated with the %NO 2 levels in the offgas being close to the detection limit for the analyzer. Alternative gas measurement strategies are discussed which could improve sensitivity and reduce uncertainty. Limitations to the precision of the probe measurements are also discussed. It is also noted that the offgas is an average of the products from simultaneous dissolution of elements in multiple wells. Detection of a high fragment height level in an individual well may be hindered by low levels in other wells.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LuSEE-night power distribution system design

The Lunar Surface Electromagnetic Experiment at Night (LuSEE-Night) is a low-frequency, 0.5 to 50 MHz, radio experiment on the radio-quiet far side of the Moon. The instrument will be launched by NASA Commercial Lunar Payload Services in 2026. The LuSEE-Night instrument core is composed of a radio frequency spectrometer (SPT) processing signals from four antennas, the Data Controller Board (DCB), low electromagnetic interference (EMI) Picket Fence Power Supply (PFPS), and Power Distribution Unit (PDU). The battery powers the instrument during the lunar night and stores energy harvested by the solar panel array during the lunar day. The battery charging is controlled by the Power Conditioning and Distribution Unit (PCDU). The unregulated power is supplied either by the SpaceCraft (S/C) or the battery and gets distributed to the PFPS, communication radio, heaters, and deployables through the PDU. The PFPS generates all regulated low-voltage rails using switching regulation synchronized to the LuSEE-Night clock, which ensures self-generated EMI will be confined to well-defined frequency bins. Here, we discussed the unregulated power distribution system architecture and functionality. The PDU engineering and flight modules are developed and characterized to confirm compliance with LuSEE-Night requirements. At the time of writing, all power subsystem components have been integrated into the payload.

47 OTHER INSTRUMENTATION↗

DDCP framework

DDCP protocol software 1.0 This repository contains the C++ implementation of version 1.x of the Distributed Data Communications Protocol (DDCP). DDCP provides request/reply, feature discovery, data transfer, control, interrupt, and transaction support for communicating with accelerator instrumentation over UDP. The standard server port is 65000. The framework is a source dependency for services that communicate directly with DDCP hardware. It is not a deployable service by itself.

Joshi, Shreya [Fermi National Accelerator Laborato↗

Water-cooled Helmholtz coil for Ultra-low Magnetic Field Testing

Ultra-low magnetic field testing requires precise and finely calibrated instrumentation interacting with very marginal magnetic fields in highly controlled environments. We designed a large Helmholtz coil system for implementation around a 17.825-inch outer diameter Helium-3 Cryogenic fridge, to serve as both a field-zeroing device and to enable higher resolution on magnetic field sweeps during experiments. We present finite volume modeling and finite element analysis results which indicate the device could safely run at 20 [A] in perpetuity, producing a magnetic field of 65 [mT], without the surface facing the Cryogenic fridge exceeding 50°C. The overall system parts expense is $\$$4,882.76.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Enabling Command-and-Control in Advanced In Situ Workflows

Scientific discovery is progressing towards autonomous science with the combination of scientific instruments, high-performance computing, and artificial intelligence in complex workflows. This evolution introduces new requirements for managing scientific workflows, including feedback loops, near real-time constraints, and the ability to dynamically control workflow execution. In situ workflows that analyze and visualize data as it is generated are well-suited to satisfy stringent time constraints and their iterative nature offers greater opportunities for command-and-control. However, only a few of the many workflow management systems available have been specifically designed to manage in situ workflows and often lack support for automated feedback loops that allow analysis and visualization components to interact with the main scientific data producer. To address this need, we present in this paper how to add command-and-control capabilities to a workflow management system. We identify the functional design requirements of such a command-and-control system, detail its architecture, interface, and core mechanisms, and illustrate how advanced in situ workflows can leverage command-and-control in three use cases: graceful termination with checkpoint, dynamic and adaptive data reduction, and event-triggered analysis.

Mehta, Kshitij [ORNL] (ORCID:0000000297149981)↗

Poster: Hardware-Based Demonstration of Temperature Control Functions for Reactor Systems

Autonomous thermal regulation in nuclear reactors remains crucial for maintaining stable operation and ensuring the integrity of fuel. To alleviate public skepticism of the safety of nuclear reactors, demonstrating control over this key factor is pivotal. Utilizing electric heat pads to simulate the heat released in a reactor core, thermocouples for temperature monitoring, and an Arduino micro programmable logic controller (PLC) with an embedded proportional-integral-derivative (PID) algorithm for control, a hardware-based demonstration of a reactor heating system will validate the efficacy of reactor control over this key parameter.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Automation of Nanoparticle Synthesis Processes in a Plasma Environment Using LabVIEW

This work presents an automated control system for the synthesis of nanomaterials by plasma-enhanced chemical vapor deposition (PECVD), implemented using the LabVIEW software environment. The main objective of the study is to develop an integrated hardware-software platform that enables sequential control of the key stages of the PECVD process, including vacuum chamber preparation, pressure monitoring, working gas supply, plasma ignition, power matching, cyclic nanomaterial growth, and optical monitoring of nanoparticles in the plasma environment. The use of LabVIEW made it possible to integrate actuator control, experimental parameter acquisition, and realtime process visualization within a single automated system. The automated cycle begins with evacuation of the reaction chamber to a predefined base pressure. Transition to the next stage is permitted only after the specified pressure threshold has been reached, ensuring reproducible initial conditions for each experiment. The program then controls the supply of the working gas through mass flow controllers (MFCs). In this work, two gas-flow control modes were considered: analog control using a 0-5 V voltage signal and digital communication via RS-232 interface. It was shown that the analog approach requires accurate scaling of the control voltage, since applying 5 V corresponds to full-scale opening of the controller and results in the maximum gas flow. In contrast, the RS232 interface enables the gas flow rate to be specified directly in sccm, improving the accuracy, flexibility, and convenience of gas-environment control. After pressure stabilization, LabVIEW initiates RF plasma ignition and executes the RF matching algorithm aimed at minimizing reflected power and improving the stability of the plasma process. A separate software module implements the cyclic nanomaterial growth mode, in which the plasma-on time, plasma duration, and total number of synthesis cycles are predefined. This approach makes it possible to control material accumulation on the substrate and to correlate the process parameters with the morphological characteristics of the resulting nanostructures. The final module of the system is designed for optical monitoring of the nanoparticle cloud density in dusty plasma. For this purpose, the change in the intensity of laser radiation passing through the plasma region is recorded using a photodetector and a Keithley 2401 measuring unit connected to LabVIEW via RS-232 interface. The difference between the initial and modified optical signal intensity is used as a diagnostic parameter characterizing the formation and temporal evolution of nanoparticles. The developed system demonstrates that LabVIEW can be effectively applied not only for the automation of individual instruments, but also for the implementation of a complete digital control cycle for PECVD-based nanomaterial synthesis.

PECVD↗