Search NASA⌕ Search

SEARCH · Search NASA

Results for “Integrated optics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Development of Novel Ceramic Nanofilm-Fiber Integrated Optical Sensors for Rapid Detection of Coal Derived Synthesis Gas

The overall goal of this project is to conduct fundamental studies on advanced ceramic materials and fiber optic devices for developing new types of high temperature (>500°C) fiber optic chemical sensors (FOCS) for monitoring fossil (mainly coal) and biomass derived gases in power plants. The primary technical objective is to investigate and demonstrate the nanocrystalline doped-ceramic thin film enabled FOCS that possess desired stability, sensitivity and selectivity for in-situ, rapid gas detection in the syngas streams from gasification and combustion flue gases. This report summarizes research works of two integrated parts: (1) development of metal oxide solid thin films as sensing materials for detection and measurement of important gas components relevant to the coal- and biomass-derived syngas and combustion gas streams at high temperatures; and (2) development of fiber optic devices that are potentially useful for constructing FOCS in combination with the solid oxide thin films identified in this program.

10 SYNTHETIC FUELS↗

Integrable optics design principles for beam halo suppression in accelerator rings at the intensity frontier

RadiaSoft LLC is collaborating with Fermilab to fundamentally advance the field of particle accelerator design, in order to reduce cost and technical risk for next-generation hadron accelerators, and to more rapidly advance the intensity frontier of high energy physics. The Fermilab PI is one of the originators of the theory of integrable nonlinear magnetic lattices. Fermilab is the only laboratory in the world pursuing the experimental verification of the theory. Transferring Fermilab expertise to RadiaSoft LLC will enhance US competitiveness by enabling US industry to engage in the design of future high intensity hadron rings for spallation sources, neutrino sources, muon sources, subcritical nuclear reactors and waste transmutation facilities.

43 PARTICLE ACCELERATORS↗

Fabrication of Position Controlled Si/SiGe Quantum Dots for Integrated Optical Sources and Beyond

Recent work done at the University of Florida (UF) revealed a tremendously enhanced germanium diffusion process along silicon/silicon dioxide interfaces during oxidizing anneals, allowing for the controlled formation of Si quantum wires. This project seeks to further explore this unusual germanium behavior during oxidation for the purpose of forming unique and useful nano and quantum structures. Specifically, we propose here to demonstrate for the first time that this phenomenon can be extended to realize OD Si nanostructures through the oxidation of axially heterostructured vertical Si/SiGe pillars. Such structures could be of great interest for applications in integrated optoelectronics, beyond Moore's Law computing, and quantum computing.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Micromachined silicon cantilever beam accelerometer incorporating an integrated optical waveguide

A micromachined cantilever beam accelerometer is described in which beam deflection is determined optically. A diving board structure is anisotropically etched into a silicon wafer. This diving board structure is patterned from the wafer backside so as to leave a small gap between the tip of the diving board and the opposite fixed edge on the front side of the wafer. In order to sense a realistic range of accelerations, a foot mass incorporated onto the end of the beam is found to provide design flexibility. A silicon nitride optical waveguide is then deposited by low pressure chemical vapor deposition (LPCVD) onto the sample. Beam deflection is measured by the decrease of light coupled across the gap between the waveguide sections. In order to investigate sensor response and simulate deflection of the beam, we utilized a separate beam and waveguide section which could be displaced from one another in a precisely controlled manner. Measurements were performed on samples with gaps of 4.0, 6.0, and 8.0 micron and the variation of the fraction of light coupled across the gap as a function of displacement and gap spacing was found to agree with overlap integral calculations.

Burcham, Kevin E.↗

First fringes with an integrated-optics beam combiner at 10 µm A new step towards instrument miniaturization for mid-infrared interferometry

Context. Observations of milliarcsecond-resolution scales and high dynamic range hold a central place in the exploration of distant planetary systems in order to achieve, for instance, the spectroscopic characterization of exo-Earths or the detailed mapping of their protoplanetary disc birthplace. Multi-aperture infrared interferometry, either from the ground or from space, is a very powerful technique to tackle these goals. However, significant technical

79 ASTRONOMY AND ASTROPHYSICS↗

Vacuum annealed cerium-substituted yttrium iron garnet films on non-garnet substrates for integrated optical circuits

Polycrystalline cerium-substituted yttrium iron garnet (CeYIG) showing large Faraday rotation (FR) in the near-IR region was grown on non-garnet (synthetic fused silica, Si, and Si-on-insulator) substrates by sputtering followed by thermal annealing in vacuum. The FR of the films is comparable to the single crystal value. Structural characterization, magnetic properties, refractive index, extinction coefficient, surface topography, and FR vs. wavelength were measured and the magnetooptical figure of merit was compared with that of CeYIG films on garnet substrates.

36 MATERIALS SCIENCE↗

Reconfigurable acquisition system with integrated optics for a portable flow cytometer

Portable and inexpensive scientific instruments that are capable of performing point of care diagnostics are needed for applications such as disease detection and diagnosis in resource-poor settings, for water quality and food supply monitoring, and for biosurveillance activities in autonomous vehicles. In this paper, we describe the development of a compact flow cytometer built from three separate, customizable, and interchangeable modules. The instrument as configured in this work is being developed specifically for the detection of selected Centers for Disease Control (CDC) category B biothreat agents through a bead-based assay: E. coli O157:H7, Salmonella, Listeria, and Shigella. It has two-color excitation, three-color fluorescence and light scattering detection, embedded electronics, and capillary based flow. However, these attributes can be easily modified for other applications such as cluster of differentiation 4 (CD4) counting. Proof of concept is demonstrated through a 6-plex bead assay with the results compared to a commercially available benchtop-sized instrument.

60 APPLIED LIFE SCIENCES↗

Theoretical simulations of protective thin film Fabry-Pérot filters for integrated optical elements of diode pumped alkali lasers (DPAL)

The lifetime of Diode-Pumped Alkali Lasers (DPALs) is limited by damage initiated by reaction of the glass envelope of its gain medium with rubidium vapor. Rubidium is absorbed into the glass and the rubidium cations diffuse through the glass structure, breaking bridging Si-O bonds. A damage-resistant thin film was developed enhancing high-optical transmission at natural rubidium resonance input and output laser beam wavelengths of 780 nm and 795 nm, while protecting the optical windows of the gain cell in a DPAL. The methodology developed here can be readily modified for simulation of expected transmission performance at input pump and output laser wavelengths using different combination of thin film materials in a DPAL. High coupling efficiency of the light through the gas cell was accomplished by matching the air-glass and glass-gas interfaces at the appropriate wavelengths using a dielectric stack of high and low index of refraction materials selected to work at the laser energies and protected from the alkali metal vapor in the gain cell. Thin films as oxides of aluminum, zirconium, tantalum, and silicon were selected allowing the creation of Fabry-Perot optical filters on the optical windows achieving close to 100% laser transmission in a solid optic combination of window and highly reflective mirror. This approach allows for the development of a new whole solid optic laser.

36 MATERIALS SCIENCE↗

Integrated optics for coupled-cavity QED

We present an array of Fabry-Pérot free space microcavities, intended to contain atoms or other quantum emitters, coupled to each other by waveguides resonators on a chip. The concept is highly scalable and offers a unique degree of control, making it a promising platform for quantum simulations. We demonstrate experimentally the basic units of the device.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Integrated optical devices based on sol – gel waveguides using the temperature dependence of the effective refractive index

A possibility of designing optical waveguide devices based on sol – gel SiO{sub 2} – TiO{sub 2} films using the temperature dependence of the effective refractive index is shown. The dependences of the device characteristics on the parameters of the film and opticalsystem elements are analysed. The operation of a temperature recorder and a temperature limiter with a resolution of 0.6 K mm{sup -1} is demonstrated. The film and output-prism parameters are optimised. (fibreoptic and nonlinear-optic devices)

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Experimental 3-dimensional tracking of the dynamics of a single electron in the Fermilab Integrable Optics Test Accelerator (IOTA)

We present the results of experimental studies on the transverse and longitudinal dynamics of a single electron in the IOTA storage ring. IOTA is a flexible machine dedicated to beam physics experiments with electrons and protons. A method was developed to reliably inject and circulate a controlled number of electrons in the ring. A key beam diagnostic system is the set of sensitive high-resolution digital cameras for the detection of synchrotron light emitted by the electrons. With 60–130 electrons in the machine, we measured beam lifetime and derived an absolute calibration of the optical system. At exposure times of 0.5 s, the cameras were sensitive to individual electrons. Camera images were used to reconstruct the time evolution of oscillation amplitudes of a single electron in all 3 degrees of freedom. The evolution of amplitudes directly showed the interplay between synchrotron-radiation damping, quantum excitations, and scattering with the residual gas. From the distribution of measured single-electron oscillation amplitudes, we deduced transverse emittances, momentum spread, damping times, and beam energy. Estimates of residual-gas density and composition were calculated from the measured distributions of vertical scattering angles. Combining scattering and lifetime data, we also provide an estimate of the aperture of the ring. To our knowledge, this is the first time that the dynamics of a single electron are tracked in all three dimensions with digital cameras in a storage ring.

43 PARTICLE ACCELERATORS↗