Pulse height defect and energy dispersion in semiconductor detectors.
Atomic scattering contribution to pulse height defect and energy dispersion of heavy ions in semiconductor detectors
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Atomic scattering contribution to pulse height defect and energy dispersion of heavy ions in semiconductor detectors
Many of the spacecraft launched thus far have carried detectors for investigating cosmic rays, solar protons, solar plasmas, and the geomagnetically trapped radiation. These detectors, which will find continued application in the future, include ion chambers; proportional, Geiger-Muller, scintillation, Cerenkov, and solid state detectors; ion collectors; and nuclear emulsions. The instrumentation required to condition the signals from these detectors prior to telemetering is steadily growing more complex in order to permit more meaningful measurements. This report describes a number of instrumentation elements typical of the present state of the art, and a present-generation three-detector system which illustrates the integration of such basic elements into a complex system.
In the harsh radiation environment of Jupiter and with the JUpiter ICy moon Explorer (JUICE) mission including two Europa flybys where local intensities are approx. 150 krad/month behind 100 mils of Al shielding, so background from penetrating radiation can be a serious issue for detectors inside an Ion Mass Spectrometer (IMS). This can especially be important for minor ion detection designs. Detectors of choice for time-of-flight (TOF) designs are microchannel plates (MCP) and some designs may include solid state detectors (SSD). The standard approach is to use shielding designs so background event rates are low enough that the detector max rates and lifetimes are first not exceeded and then the more stringent requirement that the desired measurement can successfully be made (i.e., desired signal is sufficiently greater than background noise after background subtraction is made). GEANT codes are typically used along with various electronic techniques, but such designs need to know how the detectors will respond to the simulated primary and secondary radiations produced within the instrument. We will be presenting some preliminary measurements made on the response of MCPs to energetic electrons (20 ke V to 1400 ke V) using a Miniature TOF (MTOF) device and the High Energy Facility at Goddard Space Flight Center which has a Van de Graaff accelerator.
The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the Polar satellite is studied by using a three-dimensional particle-in-cell (PIC) code. When the satellite passes through the region of low-density plasma, the satellite charges to positive potentials as high as 40-50 V, owing to the photoelectron emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, ion-rich xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at approximately 2 V. Accordingly, in our three-dimensional PIC simulation we considered that the potential of the satellite is 2 V as a fixed bias. Considering the relatively high density of the xenon plasma in the sheath (10-10(exp 3)/cc), the ambient plasma of low density (<1/cc) is neglected. In the simulations the electric fields and plasma dynamics are calculated self-consistently. We found that an 'apple'-shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission a high positive potential hill develops. Near the Thermal Ion Dynamics Experiment detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations it takes only about a couple of tens of electron gyroperiods for the sheath to reach a quasi steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. After this time the expansion of the sheath in directions transverse to the ambient magnetic field slows down because the electrons are magnetized. Using the quasi steady sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.
In the Indian cosmic ray experiment (IONS) in Spacelab-3 the intention is to study nuclei up to iron in low energy cosmic rays, using CR-39 (DOP) detectors. CR-39 (DOP) was exposed to He4, C12, O16, Ne20, Si28, Ar40, Cr52 and Fe56 accelerated beams from various accelerator facilities available around the world. Different beam energies and exposure angles were used. From these exposures, the charge resolution and energy resolution for the detector in the region of interest were studied. The effect of pre-annealing and depth on the response of our detector was studied. For isotopic resolution, exposed the detector samples were exposed to Ne2O and Ne22 accelerated beams. Samples of CR-39 (DOP) exposed to different accelerated heavy ions were kept in the detector module to take into account the effect of ambient conditions on detector response during the flight.
The application of Calorimetric Low-Temperature Detectors (CLTDs) has been proposed at the Heavy-Ion TRAP facility HITRAP which is currently being installed at the Helmholtz Research Center for Heavy Ion Research GSI. This cold ion trap setup will allow the investigation of X-rays from ions practically at rest, for which the excellent energy resolution of CLTDs can be used to its full advantage. However, the relatively low intensities at HITRAP demand larger solid angles and an optimized cryogenic setup. The influence of external magnetic fields has to be taken into account. CLTDs will also be a substantial part of the instrumental equipment at the future Facility for Antiproton and Heavy Ion Research (FAIR), for which a wide variety of high-precision X-ray spectroscopy experiments has been proposed. This contribution will give an overview on the chances and challenges for the application of CLTDs at HITRAP as well as perspectives for future experiments at the FAIR facility.
Determination of the elemental composition of lunar, asteroid, and planetary surfaces is a major concern for science and resource utilization of space. The science associated with the development of a satellite or lunar rover laser-mass spectrometer instrument is presented here. The instrument would include a pulsed laser with sufficient energy to create a plasma on a remote surface. Ions ejected from this plasma travel back to the spacecraft or rover, where they are analyzed by a time-of-flight mass spectrometer, giving the elemental and isotope composition. This concept is based on the LIMA-D instrument on board the former Soviet Union Phobos-88 spacecraft sent to Mars. A laser-mass spectrometer placed on a rover or satellite would substantially improve the data return over alternative techniques. The spatial resolution would be centimeters, and a complete mass spectrum could be achieved in one laser shot. An experiment is described that demonstrates these features. A 400 mj Nd:YAG laser is focused, to an intensity of 10(exp 11) w/sq cm, onto a Al, Ag, Cu, Ge, or lunar simulant target. A plasma forms from which ions are ejected. Some of these ions travel down an 18-m evacuated flight tube to a microchannel plate detector. Alternatively, the ions are captured by an ion trap where they are stored until pulsed into a 1-m time-of-flight mass spectrometer, giving the elemental composition of the remote surface. A television camera monitors the plasma plume shape, and a photodiode monitors the temporal plasma emission . With this system, ions of Al, Ag, Cu, Ge, and lunar simulant have been detected at 18 m. The mass spectrum from the ion trap and 1-m time-of-flight tube will be presented.
Utilization of elastically scattered recoil ions to measure solid state track detector registration characteristics and particle trajectory analysis
We report on extensive tests of large-area (10cm diameter) high-purity ion-implanted silicon detectors for th Solar Isotope Spectrometer (SIS), and lithium-drifted silicon detetors for the Cosmic Ray Isotope Spectrometer (CRIS), which are under development for launch on the Advanced Composition Explorer (ACE) mission.
Far-IR Ge detectors fabricated using boron ion implantation are shown to exhibit operating characteristics compatible with requirements for low background applications. Device parameters such as low dark currents, reasonably good sensitivity, and extended wavelength threshold demonstrate that ion-implanted Ge far-IR detectors offer promise for use in astrophysics instrumentation.
Features include high ion-extraction efficiency, compactness, and light weight. Improved version of previous ionization detector features in-line geometry that enables extraction of almost every ion from region of formation. Focusing electrodes arranged and shaped into compact system of space-charge-limited reversal electron optics and ion-extraction optics. Provides controllability of ionizing electron energies, greater efficiency of ionization, and nearly 100 percent ion-collection efficiency.
An airborne vapor analyzer for detecting sub- to low- parts-per-million (ppm) hydrazine in the presence of higher concentration levels of ammonia has been under development for the Orion program. The detector is based on ambient pressure ionization and ion mobility characterization. The detector encompasses: 1) a membrane inlet to exclude particulate and aerosols from the analyzer inlet; 2) a method to separate hydrazine from ammonia which would otherwise lead to loss of calibration and quantitative accuracy for the hydrazine determination; and 3) response and quantitative determinations for both hydrazine and ammonia. Laboratory studies were made to explore some of these features including mobility measurements mindful of power, size, and weight issues. The study recommended the use of a mobility spectrometer of traditional design with a reagent gas and equipped with an inlet transfer line of bonded phase fused silica tube. The inlet transfer line provided gas phase separation of neutrals of ammonia from hydrazine at 50 C simplifying significantly the ionization chemistry that underlies response in a mobility spectrometer. Performance of the analyzer was acceptable between ranges of 30 to 80 C for both the pre-fractionation column and the drift tube. An inlet comprised of a combined membrane with valve-less injector allowed high speed quantitative determination of ammonia and hydrazine without cross reactivity from common metabolites such as alcohols, esters, and aldehydes. Preliminary test results and some of the design features are discussed.
Mitchel and Roelof (1980) reported the detection of iron in high speed solar wind flows using the small, but finite sensitivity of solid state detectors to Fe ions in the low energy (50-200 keV protons) L1 channel of the NOAA/JHU energetic particle experiment (EPE). In the current investigation, the EPE response is modeled to a convected Maxwellian to obtain the thermal velocity, flow angle, and bulk velocity of the iron distribution. It is assumed that the iron bulk flow velocity can be represented as a vector sum of the hydrogen bulk velocity and an interplanetary magnetic field (IMF) aligned velocity increment. It is found that the velocity increment is smaller than the local Alfven speed in magnitude, and that the iron thermal velocity is comparable with or greater than the proton thermal velocity, with the 'thermal' velocity defined as the square root of 2kT/m.
The field ionization neutral detector FIND operates according to the following principle: Neutral atoms are attracted toward the field ionization tips since they are polarized by the electric field of the tips. The atoms are singly ionized and repelled by the positive potential of the tips toward the detector situated behind a grid at ground potential. The ions deposit in the detector their kinetic energies, typically 26 keV, corresponding to the potential difference between the ionization region and the detector. Laboratory results show that FIND can have the resolution, sensitivities and durability required to perform in situ measurements of neutral H and He fluxes in interplanetary space, cometary halos and exospheres.
Experimental methods of mapping the equipotential surfaces near some structure of interest rely on the detection of charged particles which have traversed the regions of interest and are detected remotely. One method is the measurement of ion energies for ions created at a point of interest and expelled from the region by the fields. The ion energy at the detector in eV corresponds to the potential where the ion was created. An ionizing beam forms the ions from background neutrals. The other method is to inject charged particles into the region of interest and to locate their exit points. A set of several trajectories becomes a data base for a systematic mapping technique. An iterative solution of a boundary value problem establishes concepts and limitations pertaining to the mapping problem.
The plasma sheath generated by the operation of the Plasma Source Instrument (PSI) aboard the POLAR satellite is studied by using a 3-dimensional Particle-In-Cell (PIC) code. When the satellite passes through the region of low density plasma, the satellite charges to positive potentials as high as 4050Volts due to the photoelectrons emission. In such a case, ambient core ions cannot accurately be measured or detected. The goal of the onboard PSI is to reduce the floating potential of the satellite to a sufficiently low value so that the ions in the polar wind become detectable. When the PSI is operated, an ion-rich Xenon plasma is ejected from the satellite, such that the floating potential of the satellite is reduced and is maintained at about 2Volts. Accordingly, in our 3-dimensional PIC simulation, we considered that the potential of the satellite is 2Volts as a fixed bias. Considering the relatively high density of the Xenon plasma in the sheath (approx. 10 - 10(exp 3)/cc), the ambient plasma of low density (less than 1/cc) is neglected. In the simulations, the electric fields and plasma dynamics are calculated self-consistently. We found that an "Apple" shape positive potential sheath forms surrounding the satellite. In the region near the PSI emission, a high positive potential hill develops. Near the Thermal Ion Detection Experiment (TIDE) detector away from the PSI, the potentials are sufficiently low for the ambient polar wind ions to reach it. In the simulations, it takes about a hundred electron gyroperiods for the sheath to reach a quasi-steady state. This time is approximately the time taken by the heavy Xe(+) ions to expand up to about one average Larmor radius of electrons from the satellite surface. Using the steady state sheath, we performed trajectory calculations to characterize the detector response to a highly supersonic polar wind flow. The detected ions' velocity distribution shows significant deviations from a shifted Maxwellian in the ambient polar wind population. The deviations are caused by the effects of electric fields on the ions' motion as they traverse the sheath.
A high resolution gas Cerenkov imaging detector for Cosmic Ray heavy ions is described. The performances of this detector are evaluated in view of its association with a superconducting magnet.
A new detector system has been developed to measure light fragments from heavy ion fragmentation reactions. The detector system separately measures the signals from simultaneous fragments.