At least 145 records · Page 8

The Characterization and Performance of the Luminosity Monitors for the Qweak Experiment at Jefferson Lab

The $Q_{weak}$ experiment at Jefferson Lab is a precision measurement of the weak charge of the proton using parity-violating electron scattering. To make this measurement the experiment uses diagnostic detectors with small counting statistical errors that provide information about beam and target properties. The $Q_{weak}$ luminosity monitors were designed to provide this information. The luminosity monitors are arrays of quartz \v Cerenkov detectors coupled with air lightguides to photomultiplier tubes operating in unity gain mode and read out in current mode. There are two sets of luminosity monitors, a ``downstream'' array at a mean laboratory scattering angle of 0.5 degrees that detects an equal mixture of elastic e-p and M\o ller scattered electrons and an ``upstream'' array at a mean scattering angle of 5 degrees that primarily detects low energy M\o ller scattered electrons. The monitors can also be equipped with high gain bases to operate in pulse counting mode for use as beam monitors in special low beam current diagnostic runs. The characterization and performance of the luminosity monitors will be presented.

Leacock, John↗

The SHMS 11 GeV/c spectrometer in Hall C at Jefferson Lab

The Super High Momentum Spectrometer (SHMS) has been built for Hall C at the Thomas Jefferson National Accelerator Facility (Jefferson Lab). With a momentum capability reaching 11 GeV/ c , the SHMS provides measurements of charged particles produced in electron-scattering experiments using the maximum available beam energy from the upgraded Jefferson Lab accelerator. The SHMS is an ion-optics magnetic spectrometer comprised of a series of new superconducting magnets which transport charged particles through an array of triggering, tracking, and particle-identification detectors that measure momentum, energy, angle and position in order to allow kinematic reconstruction of the events back to their origin at the scattering target. The detector system is protected from background radiation by a sophisticated shielding enclosure. The entire spectrometer is mounted on a rotating support structure which permits measurements to be taken with a large acceptance over laboratory scattering angles from 5.5° to 40°, thus allowing a wide range of low cross-section experiments to be conducted. Finally, these experiments complement and extend the previous Hall C research program to higher energies.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Machine Learning for Optimized Polarization at Jefferson Lab

Polarized cryo-targets and polarized photon beams are widely used in experiments at Jefferson Lab. Traditional methods for maintaining the optimal polarization involve manual adjustments throughout data taking by human shift takers. This may introduce some level of inconsistency simply due to the wide variety of experience and expertise of the shift takers themselves. Implementing machine learning-based control systems can improve the stability of the polarization without relying on human intervention. The cryo-target polarization is influenced by temperature, microwave energy, the distribution of paramagnetic radicals, as well as operational conditions including the radiation dose. Diamond radiators are used to generate linearly polarized photons from a primary electron beam. The energy spectrum of these photons can drift over time due to changes in the primary electron beam conditions and diamond degradation. As a first step towards automating the continuous optimization and control processes, uncertainty aware surrogate models have been developed to predict the polarization based on historical data. This talk will provide an overview of the use cases and models developed, highlighting the collaboration between data scientists and physicists at Jefferson Lab.

Jeske, Torri [Thomas Jefferson National Accelerato↗

Design and Prototyping of a Novel Toroidal Magnet System for MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment— Measurement of Lepton-Lepton Electroweak Reaction (MOLLER)—requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for three years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. The five magnets operate in a vacuum and provide the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER Collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This article presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER Collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet (TM0) of the magnet system to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 were fabricated by Everson-Tesla Incorporated, PA (USA). Finally, this article presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce↗

Design and Prototyping of a Novel Toroid Magnet System for the MOLLER Experiment at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has designed a unique spectrometer system to measure the weak interaction between electrons. The experiment ?Measurement of Lepton-Lepton Electroweak Reaction? (MOLLER) requires leveraging the recent 12 GeV electron beam upgrade and will run in JLab for 3 years. Focusing the signal for the MOLLER experiment requires five water-cooled toroidal magnets, each with unique geometry and with 7-fold symmetry. This system of magnets provides the magnetic field required to separate the incident beam electrons scattered from the target electrons (Møller scattering) and protons (elastic e-p scattering) in a liquid hydrogen target. The conceptual design was developed by the MOLLER collaboration and was given to JLab in the form of amp turns and physical location, with additional physics requirements. This paper presents prototyping of the coils and magnet support system and discusses the lessons learned during the process along with the plans for full magnet testing and installation. The JLab Magnet Group along with the MOLLER collaboration developed the specification document that includes keep out zones to design the set of magnets. JLab contracted the design of the first toroid magnet in the magnet (TM0) to Massachusetts Institute of Technology. The other four toroid magnets (TM1 through TM4) have been designed by JLab and are in the process of fabrication and assembly. Prototype coils of TM1-TM4 have been fabricated by Everson-Tesla Incorporated, PA (USA). The manuscript presents the unique challenges of the design, alignment, high current density, operating range, high radiation dose, and vacuum environment.

Kashy, David↗

DC High Voltage Conditioning of Photoemission Guns at Jefferson Lab FEL

DC high voltage photoemission electron guns with GaAs photocathodes have been used to produce polarized electron beams for nuclear physics experiments for about 3 decades with great success. In the late 1990s, Jefferson Lab adopted this gun technology for a free electron laser (FEL), but to assist with high bunch charge operation, considerably higher bias voltage is required compared to the photoguns used at the Jefferson Lab Continuous Electron Beam Accelerator Facility. The FEL gun has been conditioned above 400 kV several times, albeit encountering non-trivial challenges with ceramic insulators and field emission from electrodes. Recently, high voltage processing with krypton gas was employed to process very stubborn field emitters. This work presents a summary of the high voltage techniques used to high voltage condition the Jefferson Lab FEL photoemission gun.

43 PARTICLE ACCELERATORS↗

OPERATION AND COMMISSIONING OF THE JEFFERSON LAB UV FEL USING AN SRF DRIVER ERL

We describe the operation and commissioning of the Jefferson Lab UV FEL using a CW SRF ERL driver. Based on the same 135 MeV linear accelerator as the Jefferson Lab 10 kW IR Upgrade FEL, the UV driver ERL uses a bypass geometry to provide transverse phase space control, bunch length compression, and nonlinear aberration compensation necessitating a unique set of commissioning and operational procedures. Additionally, a novel technique to initiate lasing is described. To meet these constraints and accommodate a challenging installation schedule, we adopted a staged commissioning plan with alternating installation and operation periods. This report addresses these issues and presents operational results from on-going beam operations.

43 PARTICLE ACCELERATORS↗

Electron polarimetry at low energies in Hall C at JLab

Although the majority of Jefferson Lab experiments require multi-GeV electron beams, there have been a few opportunities to make electron beam polarization measurements at rather low energies. This proceedings will discuss some of the practical difficulties encountered in performing electron polarimetry via Mo/ller scattering at energies on the order of a few hundred MeV. Prospects for Compton polarimetry at very low energies will also be discussed. While Mo/ller scattering is likely the preferred method for electron polarimetry at energies below 500 MeV, there are certain aspects of the polarimeter and experiment design that must be carefully considered.

43 PARTICLE ACCELERATORS↗

A VXS [VITA41] Trigger Processor for the 12GEV Experimental Programs at Jefferson Lab

The VXS_Trigger_Processor [VTP] was developed and commissioned for CLAS12 in the fall of 2016. This board is a VITA41 switch card and it collects data from a variety of front-end TDC and Flash ADC modules. The VTP has since been used in several experiments at Jefferson Lab serving as the L1 trigger module for a variety of detector types, such as stacked calorimeters, strip calorimeters, time-of-flight, Cerenkov, hodoscopes, drift chambers, and silicon strips. Trigger algorithms implemented include cluster finding (1D, 2D), drift chamber segment and road finding, geometry matching between various detectors, particle counting, and general global trigger bit processing. The VTP is also capable of reading out each front-end crate with up to 40Gbps Ethernet which is an enormous increase compared to the currently used 200MB/s VME bus. Recent progress has been made to show that a firmware and software upgrade can enable existing Jefferson Lab front-end crates to operate in a streaming DAQ mode. In February 2020, tests will be performed on a full calorimeter and matched hodoscope which are components of the CLAS12 Forward Tagger detector system with beam in Hall B. This paper details the hardware performance, triggered, and streaming applications that have been implemented using the VTP for several experiments at Jefferson Lab.

ABBOTT, David↗

Jefferson Lab at 12 GeV: The Science Program

Jefferson Lab’s upgrade of its Continuous Electron Beam Accelerator Facility (CEBAF) has recently been completed. The project involved an upgrade of the accelerator to achieve a maximum beam energy of 12 GeV and the construction of a fourth end station, Experimental Hall D, as well as new detector equipment for two of the three existing halls (A, B, and C). A broad experimental program has been developed to map the nucleon’s intrinsic quark distributions in transverse space and in longitudinal momentum through measurements of deeply exclusive and semi-inclusive processes, and to probe color confinement by studying the spectrum of hadrons with active gluon degrees of freedom in the wave function. Other programs include the forward parton distribution function at large quark momentum fraction χ, the quark and gluon polarized distribution functions, measurements of electromagnetic form factors of the nucleon ground state and of nucleon resonance transitions at short distances, and the exploration of physics beyond the Standard Model in high-precision parity-violating processes and in the search for signals of dark matter. The higher beam energy is also suitable for exploration of quark hadronization properties using the nucleus as a laboratory. This review highlights major areas of hadron and nuclear science that will be the focus of the first 5 years of operation.

3D imaging↗

Operation of Jefferson Lab Polarized Electron Sources

This contribution describes Jefferson Lab polarized electron sources where the world record of high current polarized electron beam was delivered. Polarized GaAs Superlattice photoguns with long lifetime represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. Damage due to ion bombardment is the dominant mechanism that reduces photocathode yield. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

Suleiman, Riad↗

Field Mapper for Superconducting Torus Magnet for the Jefferson Lab 12GeV Upgrade

As part of the Jefferson Lab 12 GeV upgrade, the Hall B magnet system requires two conduction cooled superconducting magnets ? a Torus and a Solenoid. The Torus consists of 6 trapezoidal coils connected in series with an operating current of 3770 A. During commissioning of the torus magnet, field mapping was carried out at different levels of operating current in order to determine the field profile and field error table. In order to meet the physics requirement of the field accuracy we need magnetic field strength measurements which are accurate at the 0.1% level, and we need to know radius and azimuth to 0.1 mm and z to 0.5 mm. The center line of the torus magnet is approximately 6 m from ground level and the overall height of the torus magnet is approximately 8.5 m. There is also limited space around the magnet and in between the coils. Field mapping had to be carried out along the Z axis (i.e. along the bore) and at 4 radial locations between each coil. These restrictions provided certain challenges for the magnetic field mapping task. The mapper prototype was built and tested prior to use on the Torus itself. In this presentation the field mapper design, prototyping and actual data collection procedure will be presented.

Rajput-Ghoshal, Renuka↗

Options for an 11 GeV RF Beam Separator for the Jefferson Lab CEBAF Upgrade

The CEBAF accelerator at Jefferson Lab has had, since first demonstration in 1996, the ability to deliver a 5-pass electron beam to experimental halls (A, B, and C) simultaneously. This capability was provided by a set of three, room temperature 499 MHz rf separators in the 5th pass beamline. The separator was two-rod, TEM mode type resonator, which has a high shunt impedance. The maximum rf power to deflect the 6 GeV beams was about 3.4kW. The 12 GeV baseline design does not preserve the capability of separating the 5th pass, 11 GeV beam for the 3 existing halls. Several options for restoring this capability, including extension of the present room temperature system or a new superconducting design in combination with magnetic systems, are under investigation and are presented.

43 PARTICLE ACCELERATORS↗

Large Gas Electron Multiplier Trackers for Super Bigbite Spectrometer at Jefferson lab Hall A

The 12 GeV upgrade at Jefferson Lab (JLAB) makes many exciting nuclear experiments possible. These experiments also require new high performance instrumentation. The Super Bigbite Spectrometer (SBS) was proposed to perform a series of high precision nucleon form factor experiments at large momentum transfer. The SBS will be capable of operating at a very high luminosity and provide a large solid angle acceptance of 76 msr. SBS will be equipped with a double focal plane polarimeter. Thus, SBS will have three large trackers made of Gas Electron Multiplier (GEM) chambers. The first, second, and third trackers will consist of six, four, and four tracking layers respectively. When completed in 2017, the SBS GEM trackers will form one of the largest sets of GEM chambers in the world. The GEM trackers allow the SBS to operate under high background rates over 500 kHz/cm2, while providing an excellent spatial resolution of 70 ?m. The first tracker will be constructed at the Istituto Nazionale di Fisica Nucleare in Italy, while the second and third trackers will be built at the University of Virginia. In 2012, the first UVa SBS GEM chamber prototype was successfully constructed and tested. The GEM chamber construction details and test results will be presented in this talk.

Saenboonruang, Kiadtisak↗

Testing of the SIDIS framework at Jefferson Lab Hall C using precise measurements of light meson electroproduction

Semi-inclusive deep inelastic scattering (SIDIS) has proved to be an important tool for unveiling the inner structure of the core of the atom, the nucleons and their basic constituents. Azimuthal spin asymmetries in polarized SIDIS are directly related to transverse momentum dependent parton distributions (TMDs) and fragmentation functions. The TMDs allow one to probe the 3D dynamical structure of partons inside the nucleon. Understanding the nature of the SIDIS process is essential for TMD studies, in particular at modest energies where deviations from the leading-order factorized picture may be a significant. Precise maps of the meson cross sections and their ratios at low transverse momentum and Jefferson Lab beam energies provide a stringent test of the use of the standard SIDIS framework in terms of factorized parton distributions convoluted with fragmentation functions. The magnetic spectrometers in Hall C at Jefferson Lab are well suited for such precision measurements of fully L/T separated cross sections and their ratios. The addition of neutral particle detection enables additional opportunities. Plans for upcoming experiments that will investigate the SIDIS process at the 12 GeV Jefferson Lab will be presented.

Kinney, Edward↗

Results From the N* Program at Jefferson Lab

We discuss the results on the fundamental degrees of freedom underlying the nucleon excitation spectrum and how they evolve as the resonance transitions are investigated with increasingly better space-time resolution of the electromagnetic probe. Improved photocouplings for a number of resonant states, those for the N(1720)P13 being significantly changed, have been determined and entered into the 2008 edition of the RPP. Strong sensitivity to the N(1900)P13 state, listed now as a 2-star state in the same edition of RPP, has been observed in KΛ and KΣ photoproduction. None of the earlier observations of a Θ+5(1540) was confirmed in a series of three Jefferson Lab high statistics dedicated measurements, and stringent upper limits on production cross sections were placed in several channels. For the four lowest excited states, the Δ(1232)P33, N(1440)P11, N(1520)D13, and N(1535)S11, the transition amplitudes have been measured in a wide range in photon virtuality Q2. The amplitudes for the Δ(1232) show the importance of the pion-cloud contribution and do not show any sign of approaching the pQCD regime for Q2 < 7 GeV2. For the Roper resonance, N(1440)P11, the data provide strong evidence for this state as a predominantly radial excitation of the nucleon as a 3-quark ground state. For the N(1535)S11, comparison of the results extracted from π and η photo- and electroproduction data allowed one to specify the branching ratios of this state to the πN and ηN channels; they entered into the 2010 edition of the RPP. Measured for the first time, the longitudinal transition amplitude for the N(1535)S11 became a challenge for quark models and can be indicative of large meson-cloud contributions or alternative representations of this state. The N(1520)D13 clearly shows the rapid changeover from helicity-3/2 dominance at the real photon point to helicity-1/2 dominance at Q2 > 0.5 GeV2 confirming a long-standing prediction of the constituent quark model. The search for undiscovered but predicted states continues to be pursued with a vigorous experimental program. While recent data from Jefferson Lab and elsewhere provide intriguing hints of new states, final conclusions will have to wait for the results of the broad experimental effort currently underway with CLAS, and subsequent analyses involving the EBAC at Jefferson Lab.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗