Search NASA⌕ Search

SEARCH · Search NASA

Results for “Joule”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

Gary A. Sneiderman↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and Joule-Thomson and Stirling cryocoolers to reduce heat load on the He tank supporting the ADRs. Resolve was designed with tunable cryocooler drive frequencies so that interference could be avoided. The cryocooler generated micro-vibration changes with drive frequency and that micro-vibration causes interference and degrades instrument performance. Poor drive frequency choices have been shown to dramatically impact ADR cooling power, temperature stability, detector noise, and degrading spectroscopic performance. However, some choices are free of these features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is critical to achieving peak instrument performance. The drive frequencies of the Joule-Thomson cooler, near 52 Hz, and the Stirling coolers, near 15 Hz, were adjusted in three scan sequences while measuring interference to narrow candidate frequency options. Choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. These scans were performed routinely during ground testing. Surprisingly though, the results were not repeatable after the Dewar was warmed and re-cooled but were repeatable when remeasured during the same test campaign. Since the good/bad drive frequencies change during Dewar warmup/cooldown, and possibly after vibration events, the drive frequencies could not be finalized before launch. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

In-Orbit Selection of Cryocooler Drive Frequencies for XRISM/Resolve

The XRISM/Resolve instrument cooling system uses adiabatic demagnetization refrigerators (ADRs) to cool the detectors to 50 mK and two types of cryocoolers to reduce heat load on the He tank, Joule-Thomson and Stirling cryocoolers. Resolve was designed with tunable cryocooler frequencies so that any mechanical interference and its effect on performance could be minimized. Measurements at different cryocooler drive frequencies were used to quantify the interference and narrow the acceptable range of frequency options. For Resolve the choice of cryocooler drive frequencies dramatically influences the instrument performance. Poor choices have been shown to degrade ADR cooling power and degrade the spectroscopic performance of the instrument. However, good choices have been shown to be free of undesirable features, allowing the instrument to satisfy its performance requirements with significant margin. Thus, the choice of drive frequencies is a critical factor for overall instrument performance. The drive frequencies of the Joule-Thomson cooler operating near 52 Hz, and the Stirling coolers operating near 15 Hz were adjusted in three distinct scan sequences to efficiently narrow the candidate frequency options. The frequency choices were based on stability of the 50 mK control thermometer, changes in the ADR demagnetization rate, and changes in detector noise. Scans across the drive frequency range of each cryocooler were performed multiple times during ground testing. Surprisingly, the results were not repeatable across test campaigns and did not conform to any discernable trend, but they were repeatable when remeasured within a single cool-down cycle. The conclusion was that the good/bad drive frequencies changed during Dewar warmup/cooldown, and possibly after mechanical vibration tests. Therefore, the settings could not be finalized before launch, and scans during instrument commissioning were necessary. This paper describes the cryocooler frequency scan measurements and compares the results during instrument commissioning to those performed during ground tests.

XRISM↗

(abstract) Development of Sorbent Bed Assembly for a Periodic 10K Solid Hydrogen Cryocooler

A closed-cycle 10K sorption cryocooler is being fabricated for microgravity testing during a future space shuttle mission. A critical component of this cryogenic refrigerator is the metal hydride sorbent bed assembly (SBA). The SBA uses hydrides which absorb hydrogen gas at low pressure, (i.e., about 0.25 MPa from liquid hydrogen at 25K and below 0.2 kPa from solid hydrogen near 10K) and subsequently delivers hydrogen at nearly 10 MPa to a storage reservoir to repeat the Joule-Thomson (J-T) expansion process. The SBA includes three independent hydride beds where two contain LaNi(sub 4.8)Sn(sub 0.2) alloy and the third ZrNi. Detailed descriptions will be given for the three beds, which have specialized design features to enhance performance at each step of operation. In particular, two beds must rapidly absorb hydrogen in order for the J-T cold stage to reach 10K within two minutes from a 65K holding temperature. Performance characterization results will be compared to model analyses of the SBA.

applications microgravity↗

Long-Term Cryogenic Propellant Storage on Mars with Hercules Propellant Storage Facility

This report details the process and results of roughly sizing the steady state, zero boil-off thermal and power parameters of the Hercules Propellant Storage Facility. For power analysis, isothermal and isobaric common bulkhead tank scenarios are considered. An estimated minimum power requirement of 8.3 kW for the Reverse Turbo-Brayton Cryocooler is calculated. Heat rejection concerns in soft vacuum Mars atmosphere are noted and potential solutions are proposed. Choice of coolant for liquid propellant conditioning and issues with current proposed cryocooler cycle are addressed; recommendations are made, e.g. adding a Joule-Thomson expansion valve after the Reverse Turbo-Brayton turbine in order to have two-phase, isothermal heat exchange through the Broad Area Cooling system. Issues with cross-country transfer lines from propellant storage to flight vehicle are briefly discussed: traditional vacuum jacketed lines are implausible, and Mars insulation needs to be developed.

Propellant Storage↗

Numerical Investigation of Heat Transfer and Fluid Flow within Electrochemical Hydrogen Peroxide Generation Unit

Long-term manned space missions require the onboard production of disinfectants essential for maintaining crew health and supporting life systems. Currently, disinfection aboard the International Space Station (ISS) relies on disposable wetted wipes, which are regularly resupplied from Earth. This approach imposes a significant burden on resupply logistics, storage, and waste management. To address these challenges and support future missions, efforts are underway to develop an in-situ solution that electrochemically generates hydrogen peroxide disinfectant using onboard resources. In collaboration with NASA, Faraday Technology, Inc. has advanced this concept through a series of Small Business Innovation Research (SBIR) projects, resulting in the development of a Peroxide Generation Unit (PGU). The PGU can produce up to 3 wt.% hydrogen peroxide on-demand at a rate of 1 liter per day, providing a sustainable alternative to Earth-dependent supplies. The resulting aqueous hydrogen peroxide (H₂O₂) is an effective disinfectant, safe for crew use, compatible with spacecraft systems, and free from volatiles, off-gassing, or residues. This innovation offers a reliable, efficient solution for onboard disinfection, reducing dependence on Earth-based resupply while ensuring the health and safety of space crews. Generating hydrogen peroxide at the required rate needs high voltages and currents, exceeding 20V and 2A respectively, which leads to significant heat generation from Joule heating. This temperature rise poses a risk to sensitive system components, especially critical and expensive membranes that can degrade under thermal stress. To mitigate this risk, the thermal, fluid, and electrical flows within the system are modeled computationally using the commercial software COMSOL. The numerical simulations are validated against experimental data from both sub-scale and alpha-scale systems. Once verified, the model is employed to identify thermal hotspots, investigate their underlying causes, and explore solutions to prevent them.

Life Support Systems (LSS)↗

Eddy current disk valve

Quick-opening, intermittent flow valve requires a small amount of electrical energy to open and which closes by the restoring action of a rubber stop. This eddy current disk valve opens in less than 100 microseconds and takes only 10 joules of energy.

Larson, A. V.↗

High-pressure oxygen impact tester

To extend the compatibility evaluation of candidate materials in oxygen, a high-pressure oxygen impact tester has been designed, developed, and installed at NASA/MSFC, Huntsville, Alabama. The tester has an operating range from ambient to 69,000 newton/sq m (10,000 psig) pressures and from the normal boiling point of liquid oxygen to 394 K (121 C) temperatures. The tester was designed to deliver 97.63 joules (72 ft-lb) of impact energy; however, variable height and weight can be achieved for threshold analysis. The system is completely remote and highly automated to furnish safe, reliable operation. High-frequency, fast-response instrumentation capabilities are provided to ensure maximum information output with the hope of minimizing the number of tests required for material acceptance.

Raniere, F. D.↗

Thermophysical properties of parahydrogen from the freezing liquid line to 5000 R for pressures to 10000 psia

The tables include entropy, enthalpy, internal energy, density, volume, speed of sound, specific heat, thermal conductivity, viscosity, thermal diffusivity, Prandtl number, and the dielectric constant for 65 isobars. Quantities of special utility in heat transfer and thermodynamic calculations are also included in the isobaric tables. In addition to the isobaric tables, tables for the saturated vapor and liquid are given, which include all of the above properties, plus the surface tension. Tables for the P-T of the freezing liquid, index of refraction, and the derived Joule-Thomson inversion curve are also presented.

Mccarty, R. D.↗

Transient heating in the upper atmosphere

The time-dependent response of the upper atmosphere to transient heat sources is considered. The basic problem is that of heating a compressible, heat-conducting fluid, which is described in the one-dimensional case by an analytic solution. Comparisons with satellite drag data of such first-order solutions are shown to be useful in determining energy requirements and in determining some constraints on the spatial distribution of the heating. Recent OGO-6 mass spectrometer and interferometric temperature measurements show that atmospheric disturbances during geomagnetic storms are much more prominent in the auroral zones. These results suggest that joule dissipation of auroral currents are important contributors to orbital perturbations of satellites.

Thomas, G. E.↗

Dissipation of electric fields in the ionosphere

The heating and movement of the upper atmosphere at ionospheric levels in response to electric currents are discussed. Joule dissipation, generation of winds, and pressure gradients are significant factors in the energetics of the ionospheric electric currents flowing during magnetic storms and also of the Sq current system.

Cole, K. D.↗

Generation of a uranium plasma at near gaseous core reactor conditions.

A constricted sliding spark discharge is used to generate a high density, high temperature uranium plasma. Uranium particle densities up to 10 to the 20th power per cu cm are obtained over a temperature range of 30,000 to 50,000 K. The device consists of a capillary discharge channel lined with pressed and sintered UO2. A 250 joule capacitor bank is discharged into the channel, producing a plasma of 10-20 microsec duration. Spectroscopic observations are made over the spectral range of 1300 to 2500 A.

Davis, J. F., III↗

Magnetic storm effects in the neutral composition.

Demonstration that the thermospheric wind circulation excited during magnetic storms, presumably by Joule heating within the auroral zone, is an effective mechanism for removing atomic oxygen at high latitudes. Wind-induced variations in O exceed the temperature effects up to 250 km. The calculated depletion is most pronounced at around 180 km, where the density can decrease by as much as a factor of two, consistent with the observed storm time variations in the ionosphere. At higher altitudes, this effect is canceled by the thermal expansion in atomic oxygen, thus explaining the negligible response in the concentration of this atmospheric constituent under disturbed conditions, when N2 increased by as much as a factor of ten.

Mayr, H. G.↗

Performance testing of a solid propellant pulsed plasma microthruster.

Extensive performance testing has been carried out on a solid propellant, pulsed plasma microthruster essentially identical to the four units aboard the DOD, Lincoln Experimental Satellite (LES)-6. Tests include measurements of thrust, specific impulse, thrust vector, impulse bit repeatability, intermittency and endurance. The results show good impulse bit repeatability and a well defined thrust vector. The impulse bit, with a 1.85-joule input, was found to be approximately 26 micronewton-seconds at 190 seconds specific impulse. Based upon the results of the intermittency tests, a better understanding of the intermittency mechanism has been achieved.

Williams, T. E.↗

Longitudinal variations of thermospheric composition indicating magnetic control of polar heat input.

Measurement of neutral N2, O, and He densities from Ogo 6 over the south polar region during magnetically quiet periods in late August and early September 1969. It is found that N2 densities, when they are extrapolated to a common altitude, maximize at about 0800 UT near 70 deg invariant latitude. The density of He has a minimum at this time, and the density of O has a slight maximum. It is proposed that these phenomena are the result of cyclic variations in soft electron precipitation, which heats the thermosphere either directly or through enhanced Joule heating. This heat energy would increase the gas temperature, the increase in the gas temperature leading to the N2 increase, and would vary the composition by generation of a wind system.

Hedin, A. E.↗

Magnetogasdynamic heat transfer to a hemispherical body in a supersonic argon plasma.

Measurements of the heat transfer to a hemispherical body in a Mach 4.6, low density, argon plasma are reported. The experiments demonstrated that local wall currents affected the heat flux to the electrically conducting surface, both without and with internally applied magnetic fields. Such currents were induced by a nonuniform shock-layer plasma potential; but with applied fields, Hall currents dominated. Magnetic fields significantly increased the stagnation-region heat flux while causing a reduction over the remainder of the hemisphere. For an electrically nonconducting surface, the local heat flux was reduced, and magnetic fields insignificantly affected the heat flux. Analytical treatments indicate that joule and radiation heating were negligible.

Nowak, R. J.↗