Search NASA⌕ Search

SEARCH · Search NASA

Results for “LASER SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Laser induced photoluminescence spectroscopy of cometary radicals

Flash photolysis together with laser excitation of the product fragments was used in laboratory studies of cometary radicals. The LIPS method has been applied to the CN radical to determine: (1) Radiative lifetimes of individual rotational levels in the zeroth vibrational level of the B state; (2) energy partitioning during photodissociation of C2N2; and (3) vibrational and rotational excitation during formation of CN radicals in the photodissociation of dicyanoacetylene.

Jackson, W. M.↗

A Comparison of Multivariate and Pre-Processing Methods for Quantitative Laser-Induced Breakdown Spectroscopy of Geologic Samples

The ChemCam instrument selected for the Curiosity rover is capable of remote laser-induced breakdown spectroscopy (LIBS).[1] We used a remote LIBS instrument similar to ChemCam to analyze 197 geologic slab samples and 32 pressed-powder geostandards. The slab samples are well-characterized and have been used to validate the calibration of previous instruments on Mars missions, including CRISM [2], OMEGA [3], the MER Pancam [4], Mini-TES [5], and Moessbauer [6] instruments and the Phoenix SSI [7]. The resulting dataset was used to compare multivariate methods for quantitative LIBS and to determine the effect of grain size on calculations. Three multivariate methods - partial least squares (PLS), multilayer perceptron artificial neural networks (MLP ANNs) and cascade correlation (CC) ANNs - were used to generate models and extract the quantitative composition of unknown samples. PLS can be used to predict one element (PLS1) or multiple elements (PLS2) at a time, as can the neural network methods. Although MLP and CC ANNs were successful in some cases, PLS generally produced the most accurate and precise results.

Anderson, R. B.↗

Precision measurements of NH3 spectral lines near 11 microns using the infrared heterodyne technique

Absolute line-center frequencies for eleven lines of ammonia in near coincidence with CO2-laser transitions have been determined to accuracies of + or -3 MHz by infrared heterodyne detection. These results were obtained by heterodyning a blackbody with a stable grating-tuned CO2 gas laser. A discussion of the apparatus and method of calculation, including error analysis, is presented. With these accurately determined line-center positions, the ammonia molecule will be a useful secondary-frequency standard for diode-laser spectroscopy in the 11-micron wavelength region.

Hillman, J. J.↗

High resolution absorption coefficients for Freon-12

The ultra high resolution absorption coefficients of the Q-branch of Freon-12 obtained with tunable diode laser spectroscopy are presented. Continuous spectra are presented from 1155/cm to 1163/cm, and absolute wavelength calibration was obtained using SO2 spectra as a standard and a 5 cm Ge etalon for relative calibration between SO2 lines. The Freon-12 data obtained at a pressure of 0.05 torr showed a rich and highly structured spectra, but with the exception of three isolated features, collisional broadening reduces the spectra to a structureless continuum for nitrogen pressures greater than 20 torr. The spectra at 1161/cm continue to exhibit structure at atmospheric pressure.

Hoell, J. M.↗

Rotational inelastic cross sections for OCS-Ar, OCS-He, OCS-H2 collisions - A comparison between theory and experiment

The experimental determination of absorption line profiles for OCS nu3 vibrational transitions broadened by collisions with Ar, He, and H3 buffer gases is reported. The experimental method using diode laser spectroscopy in the five micron region is described. The data are compared with theoretical values obtained using intermolecular potentials previously suggested for these systems and infinite order sudden approximation molecular scattering calculations.

Broquier, M.↗

Physics through the 1990s: Condensed-matter physics

The volume presents the current status of condensed-matter physics from developments since the 1970s to opportunities in the 1990s. Topics include electronic structure, vibrational properties, critical phenomena and phase transitions, magnetism, semiconductors, defects and diffusion, surfaces and interfaces, low-temperature physics, liquid-state physics, polymers, nonlinear dynamics, instabilities, and chaos. Appendices cover the connections between condensed-matter physics and applications of national interest, new experimental techniques and materials, laser spectroscopy, and national facilities for condensed-matter physics research. The needs of the research community regarding support for individual researchers and for national facilities are presented, as are recommendations for improved government-academic-industrial relations.

Source record↗

Tunable diode laser spectral diagnostic studies of a pressure modulator radiometer

The successful application of high-resolution tunable diode laser spectroscopy to the diagnostic measurement of a pressure modulator radiometer (PMR) is reported, and recorded line transmission profiles for a single N2O line at 1272/cm are presented. PMR measurements obtained for mean cell pressures of about 10, 20, and 30 Torr were found to be consistent with theoretical predictions. The validity of single-pressure and two-pressure approximation representations of the mean and modulated PMR transmission spectra has been verified.

May, Randy D.↗

In situ mineralogical-chemical analysis of Martian materials at landing/roving sites by active and passive remote sensing methods

Remote sensing of the Martian surface from the ground and from orbiting spacecraft has provided some first-order insight into the mineralogical-chemical composition and the weathering state of Martian surface materials. Much more detailed information can be gathered from performing such measurements in situ at the landing sites or from a rover in combination with analogous measurements from orbit. Measurements in the wavelength range of approximately 0.3 to 12.0 micrometers appear to be suitable to characterize much of the physical, mineralogical, petrological, and chemical properties of Martian surface materials and the weathering and other alteration processes that have acted on them. It is of particular importance to carry out measurements at the same time over a broad wavelength range since the reflectance signatures are caused by different effects and hence give different and complementing information. It appears particularly useful to employ a combination of active and passive methods because the use of active laser spectroscopy allows the obtaining of specific information on thermal infrared reflectance of surface materials. It seems to be evident that a spectrometric survey of Martian materials has to be focused on the analysis of altered and fresh mafic materials and rocks, water-bearing silicates, and possibly carbonates.

Neukum, G.↗

Stirling-Cycle Cooling For Tunable Diode Laser

Miniature Stirling-cycle cooler effective in continously cooling PbSnTe tunable diode laser to stable operating temperature near 80 K. Simplifies laboratory diode-laser spectroscopy and instruments for use aboard aircraft and balloons.

Durso, Santo S.↗

Line-width temperature dependence of selected R-branch transitions in the nu-3 fundamental of (N-14)2O-16 between 135 and 295 K

Tunable diode laser spectroscopy has been used to measure the temperature dependence of N2 foreign gas broadening coefficients for eight R-branch transitions in the nu-3 fundamental of (N-14)2O-16 at 135, 176, 210, and 295 K. The exponent n of the relation for quadrupole-quadrupole collisional interactions is found to range from 0.66 to 0.71, in approximate agreement with the theoretically predicted value of 0.75.

Loewenstein, Max↗

Toward the detection of pure carbon clusters in the Interstellar Medium (ISM)

Determination of the form and distribution of carbon in the universe is critical to understanding the origin of life on Earth and elsewhere. Two potentially large reservoirs of carbon in the interstellar medium (ISM) remain unexplored. These are polycyclic aromatic hydrocarbons (PAH) and pure carbon clusters. Little information exists on the structures, properties, and transition frequencies of pure carbon clusters. The work described is designed to provide a specific inventory of laboratory frequencies and physical properties of this carbon clusters so that efforts can be made to detect them in cold interstellar sources by far-infrared astronomy. Data is given from infrared laser spectroscopy determination of the structure of C3, C4, C5, C6, C7, and C9.

Heath, J. R.↗

Improved Optics For Quasi-Elastic Light Scattering

Improved optical train devised for use in light-scattering measurements of quasi-elastic light scattering (QELS) and laser spectroscopy. Measurements performed on solutions, microemulsions, micellular solutions, and colloidal dispersions. Simultaneous measurements of total intensity and fluctuations in total intensity of light scattered from sample at various angles provides data used, in conjunction with diffusion coefficients, to compute sizes of particles in sample.

Cheung, Harry Michael↗

Laboratory Studies of Chemical and Photochemical Processes Relevant to Stratospheric Ozone

This is the final report for this project. Its purpose is to reduce the uncertainty in rate coefficients for key gas-phase kinetic processes which impact our understanding of stratospheric ozone. The main emphasis of this work is on measuring the rate coefficients for the reactions of HO2 + O3, and HO2 + NO2 in the temperature range (200-240 K) relevant to the lower stratosphere. In order to accomplish this, a high pressure turbulent flow tube reactor was built and its flow characteristics were quantified. The instrument was coupled with tunable diode laser spectroscopy for HO2 detection. Room temperature measurements of the HO2 + NO2 rate coefficients over the pressure range of 50-300 torr agree well with previous measurements. Preliminary measurements of the HO2 + O, rate coefficients at 50 - 300 Torr over the temperature range of 208-294 K agree with the NASA evaluation from 294-225 K but deviate significantly (50 % higher) at approximately 210 K.

Villalta, P. W.↗

The Effects of Gravity on ZBLAN Glass

Heavy metal fluoride glass fibers show promise in applications such as surgical lasers, spectroscopy and imaging fiber bundles. ZBLAN, which is within this class has been studied for a number of years. ZBLAN's theoretical attenuation coefficient is approximately 0.002 dB/km which is much better than that of fused silica at 0.2 dB/km. However, due to impurities and crystallites the attenuation coefficients achieved to date are considerably larger than those of fused silica. Impurities can be controlled with better processing techniques. Crystallization has been found to be a function of gravity. It is found that heating to the crystallization temperature in unit gravity results in crystallization while heating in reduced gravity does not. The exact mechanism for this phenomenon is not known but is speculated to be related to stress.

Tucker, Dennis S.↗

Theoretical Study of Electron Scattering By Small Clusters and Adsorbates

Current interest in clusters stems from their role as novel materials as well as a possible extension of cluster results to bulk systems. Experimental investigations on clusters have been carried out using laser spectroscopy, microwave spectroscopy, heavy-particle collisions, as well as electron collisions with earlier experimental work on electron attachment and ionization having been reviewed previously. Recently, Mark and coworkers studied the decay channels of cluster ions following electron impact ionization. Rauth et al. reported the formation of the superhalogen ion SF7(-) and other nonstoichiometric cluster ions in their study of electron attachment to SF6 clusters. Kresin et al. measured the absolute electron-impact depletion cross section of metal clusters Na8, Na(20), and Na(40). They found that the inelastic scattering cross section increased with cluster size and was considerably greater than the hard sphere collision cross sections. They hypothesized that electron attachment and collision-induced fragmentation were the dominant physical processes responsible for this effect. For the two smaller clusters, they also found a sharp increase in the cross section near threshold. Most theoretical studies of clusters have been devoted to their electronic structures, vibrational relaxation, and predissociation while investigations of electron scattering from clusters has been lacking. In view of this, we recently undertook an ab initio study of electron scattering from small Be clusters and BeCO. Beryllium was chosen because it is readily amenable to ab t'nitio calculations. Moreover, the electronic structure of Be clusters has been studied extensively, showing that the Be-Be bond is relatively weak in comparison with a normal chemical bond. Our investigation focuses on how the cross sections change with cluster size and geometry. The range of energy studied, 0.05 - 5.0 eV, is chosen because of the ubiquitous resonance in the low-energy scattering of Be. Hence it can be determined if it is possible, as a consequence of the weaker bonds in the Be clusters, to identify the atomic origin of the cluster resonance.

Huo, Winifred M.↗

A Kinetic and Product Study of the Cl + HO2 Reaction

Absolute rate data and product branching ratios for the reactions Cl + HO2 to HCl + O2 (k1a) and Cl + HO2 to OH + ClO (k1b) have been measured from 226 to 336 K at a total pressure of 1 Torr of helium using the discharge flow resonance fluorescence technique coupled with infrared diode laser spectroscopy. For kinetic measurements, pseudo-first-order conditions were used with both reagents in excess in separate experiments. HO2 was produced by two methods: through the termolecular reaction of H atoms with O2 and also by the reaction of F atoms with H2O2. Cl atoms were produced by a microwave discharge of Cl2 in He. HO2 radicals were converted to OH radicals prior to detection by resonance fluorescence at 308 nm. Cl atoms were detected directly at 138 nm also by resonance fluorescence. Measurement of the consumption of HO2 in excess Cl yielded k1a and measurement of the consumption of Cl in excess HO2 yielded the total rate coefficient, k1. Values of k1a and k1 derived from kinetic experiments expressed in Arrhenius form are (1.6 +/- 0.2) x 10-11 exp[(249 +/- 34)/T] and (2.8 +/- 0.1) x 10-11 exp[(123 +/- 15)/T] cm3 molecule-1 s-1, respectively. As the expression for k1 is only weakly temperature dependent, we report a temperature-independent value of k1 = (4.5 +/- 0.4) x 10-11 cm3 molecule-1 s-1. Additionally, an Arrhenius expression for k1b can also be derived: k1b = (7.7 +/- 0.8) x 10-11 exp[-(708 +/- 29)/T] cm3 molecule-1 s-1. These expressions for k1a and k1b are valid for 226 K T 336 and 256 K T 296 K, respectively. The cited errors are at the level of a single standard deviation. For the product measurements, an excess of Cl was added to known concentrations of HO2 and the reaction was allowed to reach completion. HCl product concentrations were determined by IR absorption yielding the ratio k1a/k1 over the temperature range 236 K T 296 K. OH product concentrations were determined by resonance fluorescence giving rise to the ratio k1b/k1 over the temperature range 226 K T 336 K. Both of these ratios were subsequently converted to absolute numbers. Values of k1a and k1b from the product experiments expressed in Arrhenius form are (1.5 +/- 0.1) x 10-11 exp[(222 +/- 17)/T] and (10.6 +/- 1.5) x 10-11 exp[-(733 +/- 41)/T] cm3 molecule-1 s-1, respectively. These expressions for k1a and k1b are valid for 256 K T 296 and 226 K T 336 K, respectively. A combination of the kinetic and product data results in the following Arrhenius expressions for k1a and k1b of (1.4 +/- 0.3) x 10-11 exp[(269 +/- 58)/T] and (12.7 +/- 4.1) x 10-11 exp[-(801 +/- 94)/T] cm3 molecule-1 s-1, respectively. Numerical simulations were used to check for interferences from secondary chemistry in both the kinetic and product experiments and also to quantify the losses incurred during the conversion process HO2 to OH for detection purposes.

rate constants↗

Portable Multigas Monitors for International Space Station

The Environmental Health System (EHS) on International Space Station (ISS) includes portable instruments to measure various cabin gases that acutely impact crew health. These hand-held devices measure oxygen, carbon dioxide, carbon monoxide, hydrogen chloride and hydrogen cyanide. The oxygen and carbon dioxide units also serve to back up key functions of the Major Constituent Analyzers. Wherever possible, commercial off-the-shelf (COTS) devices are employed by EHS to save development and sustaining costs. COTS hardware designed for general terrestrial applications however has limitations such as no pressure compensation, limited life of the active sensor, calibration drift, battery issues, unpredictable vendor support and obsolescence. The EHS fleet (inflight and ground inventory) of instruments is both aging and dwindling in number. With the retirement of the US Space Shuttle, maintenance of on-orbit equipment becomes all the more difficult. A project is underway to search for gas monitoring technology that is highly reliable and stable for years. Tunable Diode Laser Spectroscopy (TDLS) seems to be the front-runner technology, but generally is not yet commercially available in portable form. NASA has fostered the development of TDLS through the Small Business Innovative Research (SBIR) program. A number of gases of interest to the aerospace and submarine communities can be addressed by TDLS including the list mentioned above plus hydrogen fluoride, ammonia and water (humidity). There are several different forms of TDLS including photoacoustic and direct absorption spectroscopy using various multipass cell geometries. This paper describes the history of portable gas monitoring on NASA spacecraft and provides a status of the development of TDLS based instruments. Planned TDLS flight experiments on ISS could lead both to operational use on ISS and important roles in future Exploration spacecraft and habitats.

Mudgett, Paul D.↗

Organic Molecules in the Sheepbed Mudstone, Gale Crater, Mars

The Sample Analysis at Mars (SAM) instrument on the Curiosity rover is designed to determine the inventory of organic and inorganic volatiles thermally released from solid samples using a combination of evolved gas analysis (EGA), gas chromatography mass spectrometry (GCMS), and tunable laser spectroscopy. Here we report on various chlorinated hydrocarbons (chloromethanes, chlorobenzene and dichloroalkanes) detected at elevated levels above instrument background at the Cumberland (CB) drill site, and discuss their possible sources.

Freissinet, C.↗