Search NASA⌕ Search

SEARCH · Search NASA

Results for “LEED”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Catalysts for electrochemical generation of oxygen

An effort was made to study the effects of cation and anion additions on oxygen evolution kinetics on platinum and the inhibitive or catalytic nature of the additions. The kinetics and mechanism of oxygen evolution on planitum metal in hydrofluoric and sulfuric acids, including the effects of foreign anions, were examined. The LEED-Auger-thin layer electrochemical system was developed for the examination of electrocatalytic surfaces. Samples for electrocatalytic LEED-Auger studies were prepared and examined.

Ogrady, W. E.↗

Adsorption of oxygen on W/100/ - Adsorption kinetics and structure

The adsorption of oxygen on W(100) single-crystal surfaces is studied by Auger electron spectroscopy (AES), flash desorption, low-energy electron diffraction (LEED), and retarding-field work-function measurements. The AES results reveal stepwise changes in the sticking coefficients in the coverage range 0 to 1 and activated adsorption at higher coverages. Upon room-temperature adsorption, a series of complex LEED patterns is observed. In layers adsorbed at 1050 K and cooled to room temperature, the p(2 x 1) structure is the first ordered structure observed. This structure shows a reversible order-disorder transition between 700 and 1000 K and is characterized by a work function which is lower than that of the clean surface. Heating room-temperature adsorbates changes their structure irreversibly. At temperatures below 750 K, some new structures are observed.

Bauer, E.↗

Catalysts for electrochemical generation of oxygen

Single crystal surfaces of platinum and gold and transition metal oxides of the spinel type were studied to find more effective catalysts for the electrolytic evolution of oxygen and to understand the mechanism and kinetics for the electrocatalysis in relation to the surface electronic and lattice properties of the catalyst. The single crystal studies involve the use of low energy electron diffraction (LEED) and Auger electron spectroscopy as complementary tools to the electrochemical measurements. Modifications to the transfer system and to the thin-layer electrochemical cell used to facilitate the transfer between the ultrahigh vacuum environment of the electron surface physics equipment and the electrochemical environment with a minimal possibility of changes in the surface structure, are described. The electrosorption underpotential deposition of Pb onto the Au(111), (100) and (110) single crystal surfaces with the thin-layer cell-LEED-Auger system is discussed as well as the synthesis of spinels for oxygen evolution studies.

Hagans, P.↗

Silicide surface phases on gold

The crystalline silicide layers formed on (111) and (100) surfaces of Au films on various Si single-crystal substrates are studied by LEED and AES in conjunction with sputter-depth profiling as a function of annealing temperature. On the (111) surface, three basic silicide structures are obtained corresponding to layers of various thicknesses as obtained by different preparation conditions. The (100) surface shows only two different structures. None of the structures is compatible with the various bulk silicide structures deduced from X-ray diffraction. Using LEED as a criterion for the presence or absence of silicide on the surface, smaller layer thicknesses are obtained than reported previously on the basis of AES studies.

Green, A. K.↗

Nitridation of Si(111) by nitrogen atoms. II

The reaction between Si(111) and nitrogen atoms has been investigated by LEED, Auger, and electron energy loss (ELS) techniques. The early stage of the reaction at 850-1050 C involves the formation of a chemically reacted monolayer which grows in islands. The sticking coefficient for the submonolayer is estimated to be of the order of unity. Two electronically different surface structures can be formed during these stages, yielding the '8 x 8' and the quadruplet LEED patterns; the quadruplet unit cell is the one with the highest nitrogen density. A pure quadruplet structure is obtained from samples with a carbon contamination of the Si monolayer of about 5 pct. During the multilayer stages, the influence of the substrate is not as important, and the reactions at 850 C and above produce quadruplet-like local structures.

Schrott, A. G.↗

Growth and characterization of epitaxial SrF2 on InP(100)

The epitaxial growth of 100-262.5-nm SrF2 films on n-type and p-type (100)InP in a conventional baked UHV system at base pressure about 200 ptorr, temperature 250-350 C, and growth rate from less than 100 to about 200 pm/s. Substrates are chemicomechanically polished, degreased, bombarded with 500-eV Ar ions for 3-4 min at 350 C, and annealed for 23-30 min at 350 C, producing a slightly In-rich (In/P = 1.02) In-island-free surface with a (4 x 1) or (1 x 1) LEED structure. Films grown at 350 C and less than 100 pm/s are found to be smooth and free of cracks in most cases, with a highly faceted (1 x 1) LEED structure. The electrical properties of the SrF2 films are found to be acceptable only when the ohmic contacts are applied prior to the substrate prior to SrF2 growth.

Sinharoy, S.↗

Surface Reconstruction of Hexagonal Y-doped HoMnO3 and LuMnO3 Studied using Low-energy Electron Diffraction

We have investigated the (0001) surfaces of several hexagonal manganite perovskites by low-energy electron diffraction (LEED) in order to determine if the surface periodicity is different from that of the bulk materials. These LEED studies were conducted using near-normal incidence geometry with a low energy electron microscope (LEEM)/LEED apparatus from room temperature to 1200 C and with an electron energy in the range of 15-50 eV. Diffraction patterns showed features of bulk-terminated periodicity as well as a 2 x 2 surface reconstruction. Possible origins for this surface reconstruction structure are discussed and comparisons are made with surface studies of other complex oxides.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Startup of the New 200 West Pump-and-Treat, Hanford Site, Richland, Washington - 13214

On June 28, 2012, CH2M HILL Plateau Remediation Company (CHPRC) completed the construction and acceptance testing for a new 2,500 gallon-per-minute (gpm) pump-and-treat (P and T) system in the 200 West Area of the Hanford Site in Washington State. This system is designed to remove Tc-99, carbon tetrachloride, trichloroethene (TCE), nitrate, and total and hexavalent chromium from groundwater using ion exchange, anoxic and aerobic bioreactors, and air stripping. The system will eventually remove uranium from groundwater using ion exchange as well. The startup of the P and T system is important because it will ensure that contaminants from the 200 West Area never reach the Columbia River. When fully operational, the 200 West P and T will include approximately 23 extraction wells and 21 injection wells. The extraction wells are 8 inches in diameter, are completed with well screens 100 feet or more in length, and are distributed throughout the central portion of the 5-square-mile carbon tetrachloride plume. The injection wells are also 8 inches in diameter and are installed up-gradient of the plumes to recharge the aquifer and down-gradient of the plumes for flow-path control. Groundwater in the 200 West Area is approximately 250 feet below ground surface, and the aquifer is 200 feet or more in thickness. All of the contaminants (except nitrate) are found within the perimeter of the carbon tetrachloride plume and occur at various depths throughout the aquifer. The 200 West P and T consists of two separate buildings to conduct groundwater treatment. The RAD building contains an ion exchange system to remove Tc-99 from groundwater at a maximum flow rate of 600 gpm. The RAD building only accepts water from those extraction wells showing elevated Tc-99 concentrations. Groundwater initially fills an influent tank, is then pumped through particulate filters (to remove suspended materials), and then passes through two parallel treatment trains containing Purolite{sup R} A530E resin (which has been proven effective in removing Tc-99). The water is then transferred to the biological treatment building for further treatment. When the lead vessel in each of the two treatment trains becomes fully loaded with Tc-99, the Purolite A530E resin is transferred to a separate tank where it is heated to 160 deg. F to remove volatile organics prior to disposal at the Environmental Restoration Disposal Facility. The biological treatment building has a maximum flow capacity of 2,500 gpm. Groundwater from the nonradiological extraction wells and treated groundwater from the RAD building are initially pumped into an equalization tank and then into two parallel fluidized bed reactors (FBRs). The FBRs contain granulated activated carbon in suspension for microbes to populate, a carbon-based food source for the microbes to eat (e.g., MicroCg{sup TM}, molasses, or sodium lactate), and nitrate for the microbes to breathe (represents 'anoxic' conditions that contain little or no dissolved oxygen). The FBRs are maintained at a temperature between 55 deg. F and 90 deg. F, and at a pH between 6.5 and 6.8, to maximize microbial growth. The FBRs break down the nitrate, reduce the hexavalent chromium to trivalent chromium, and break down a good portion of the carbon tetrachloride and TCE. From the FBRs, groundwater is pumped through a carbon separation tank, then through a splitter box that divides the water evenly between four membrane bioreactors (MBRs) that further break down the contaminants. The MBRs have aeration capacity to provide sufficient oxygen for maintaining the aerobic biological process. The MBRs use submerged membranes for filtration. Vertically strung fibers are found in the membrane zone where a vacuum draws water through tiny pores in the fibers. The liquid is then pumped to air strippers to remove any volatile organics that have passed through the bioreactors. Solids from the MBRs are pumped to rotary drum thickeners and centrifuges for dewatering prior to lime being added to kill the bacteria and control odor. The conditioned sludge is then disposed at the Environmental Restoration Disposal Facility. The final treated water is then pumped to the injection well field. The 200 West P and T is a Leadership in Energy and Environmental Design (LEED) gold-certified facility that has an expected 70% energy cost savings over the lifetime of the plant. Fifty percent of the steel used in construction was recycled, 420 tons of recycled concrete were used, and over 75% of construction waste was diverted from landfills. The plant is only staffed one shift per day, and it uses a call-out system if the plant goes down during off-shift hours. Initial sampling results have shown that the 200 West P and T is successfully reducing contaminant levels well below the cleanup levels specified in the Record of Decision, Hanford 200 Area 200-ZP-1 Superfund Site, Benton County, Washington [1]. CHPRC and the U.S. Department of Energy are continuing to look for ways to reduce operational costs, such as testing alternative resins for removing radionuclides and finding less expensive carbon substrate sources. The benefit to others is a LEED gold-certified, 2,500 gpm P and T system that may be used as a model for other complex sites. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Daemen Alternative Energy/Geothermal Technologies Demonstration Program Erie County

The purpose of the Daemen Alternative Energy/Geothermal Technologies Demonstration Project is to demonstrate the use of geothermal technology as model for energy and environmental efficiency in heating and cooling older, highly inefficient buildings. The former Marian Library building at Daemen College is a 19,000 square foot building located in the center of campus. Through this project, the building was equipped with geothermal technology and results were disseminated. Gold LEED certification for the building was awarded. 1) How the research adds to the understanding of the area investigated. This project is primarily a demonstration project. Information about the installation is available to other companies, organizations, and higher education institutions that may be interested in using geothermal energy for heating and cooling older buildings. 2) The technical effectiveness and economic feasibility of the methods or techniques investigated or demonstrated. According to the modeling and estimates through Stantec, the energy-efficiency cost savings is estimated at 20%, or $24,000 per year. Over 20 years this represents $480,000 in unrestricted revenue available for College operations. See attached technical assistance report. 3) How the project is otherwise of benefit to the public. The Daemen College Geothermal Technologies Ground Source Heat Pumps project sets a standard for retrofitting older, highly inefficient, energy wasting and environmentally irresponsible buildings quite typical of many of the buildings on the campuses of regional colleges and universities. As a model, the project serves as an energy-efficient system with significant environmental advantages. Information about the energy-efficiency measures is available to other colleges and universities, organizations and companies, students, and other interested parties. The installation and renovation provided employment for 120 individuals during the award period. Through the new Center, Daemen will continue to host a range of events on campus for the general public. The College does not charge fees for speakers or most other events. This has been a long-standing tradition of the College.

15 GEOTHERMAL ENERGY↗

Installing Hotel Rooftop Solar Array

This case study describes how a luxury hotel, Bardessono, utilized a major roof-top solar array in its design to achieve significant energy savings and LEED Platinum certification.

LEED, LEED Platinum, rooftop array, solar, solar p↗

Formaldehyde and acetaldehyde exposure mitigation in US residences: In-home measurements of ventilation control and source control

Measurements were taken in new US residences to assess the extent to which ventilation and source control can mitigate formaldehyde exposure. Increasing ventilation consistently lowered indoor formaldehyde concentrations. However, at a reference air exchange rate of 0.35 h -1 , increasing ventilation was up to 60% less effective than would be predicted if the emission rate were constant. This is consistent with formaldehyde emission rates decreasing as air concentrations increase, as observed in chamber studies. In contrast, measurements suggest acetaldehyde emission was independent of ventilation rate. To evaluate the effectiveness of source control, formaldehyde concentrations were measured in Leadership in Energy and Environmental Design (LEED) certified/Indoor airPLUS homes constructed with materials certified to have low emission rates of volatile organic compounds (VOC). At a reference air exchange rate of 0.35 h -1 , and adjusting for home age, temperature and relative humidity, formaldehyde concentrations in homes built with low-VOC materials were 42% lower on average than in reference new homes with conventional building materials. Without adjustment, concentrations were 27% lower in the low-VOC homes. The mean and standard deviation of formaldehyde concentration were 33 μg m-3 and 22 μg m -3 for low-VOC homes and 45 μg m -3 and 30 μg m -3 for conventional.

99 GENERAL AND MISCELLANEOUS↗

Daemen Alternative Energy/Geothermal Technologies Demonstration Program, Erie County

The purpose of the Daemen Alternative Energy/Geothermal Technologies Demonstration Project is to demonstrate the use of geothermal technology as model for energy and environmental efficiency in heating and cooling older, highly inefficient buildings. The former Marian Library building at Daemen College is a 19,000 square foot building located in the center of campus. Through this project, the building was equipped with geothermal technology and results were disseminated. Gold LEED certification for the building was awarded. 1) How the research adds to the understanding of the area investigated. This project is primarily a demonstration project. Information about the installation is available to other companies, organizations, and higher education institutions that may be interested in using geothermal energy for heating and cooling older buildings. 2) The technical effectiveness and economic feasibility of the methods or techniques investigated or demonstrated. According to the modeling and estimates through Stantec, the energy-efficiency cost savings is estimated at 20%, or $24,000 per year. Over 20 years this represents $480,000 in unrestricted revenue available for College operations. See attached technical assistance report. 3) How the project is otherwise of benefit to the public. The Daemen College Geothermal Technologies Ground Source Heat Pumps project sets a standard for retrofitting older, highly inefficient, energy wasting and environmentally irresponsible buildings that are quite typical of many of the buildings on the campuses of regional colleges and universities. As a model, the project serves as an energy-efficient system with significant environmental advantages. Information about the energy-efficiency measures is available to other colleges and universities, organizations and companies, students, and other interested parties. The installation and renovation provided employment for 120 individuals during the award period. Through the new Center, Daemen will continue to host a range of events on campus for the general public. The College does not charge fees for speakers or most other events. This has been a long-standing tradition of the College.

15 GEOTHERMAL ENERGY↗

Memorial Pools Energy Efficiency Retrofits

The National September 11 Memorial & Museum completed a retrofit of the submergible LED lighting fixtures in its North and South Memorial Pools, located at the World Trade Center site in New York City. The two one-acre pools are illuminated nightly by custom LED fixtures set into their base, and the original lights — in place since 2011 — had begun reaching the end of their useful life, leaving sections of the pools dim or dark. Rather than fully replacing the fixtures, the project team worked with the original manufacturer, Acuity Brands, to retrofit and reuse existing components across all eight pool walls (34 fixtures per wall), reducing cost and waste. Fixtures were shipped in custom crates to Minnesota for retrofitting, then reinstalled onsite by Memorial & Museum staff and contractor ABM. The team addressed two key technical challenges during the project: early leakage in retrofitted fixtures, resolved by introducing vacuum-sealing and nitrogen-fill testing before shipment; and chord damage during transit, resolved with custom-designed shipping crates. All eight pool walls were successfully retrofitted and reinstalled by August 27, 2025, ahead of the 25th anniversary of the September 11, 2001 attacks. Sitewide electrical consumption in September 2025 reflected an approximate 7% reduction, contributing to the institution's broader net-zero and LEED Gold sustainability goals.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

NREL Buildings Research Video

Through research, the National Renewable Energy Laboratory (NREL) has developed many strategies and design techniques to ensure both commercial and residential buildings use as little energy as possible and also work well with the surroundings. Here you will find a video that introduces the work of NREL Buildings Research, highlights some of the facilities on the NREL campus, and demonstrates these efficient building strategies. Watch this video to see design highlights of the Science and Technology Facility on the NREL campus—the first Federal building to be LEED® Platinum certified. Additionally, the video demonstrates the energy-saving features of NRELs Thermal Test Facility.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗