Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID DROP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Self-Assembly and Phase Separation for Transport: A brief argument for the continued exploration of liquid crystal flows and electrodeposition in micro-gravity

Phase separation, interfacial tension gradients, and molecular self-assembly are all phenomena frequently observed when manipulating soft condensed matter systems on Earth. Depending on the system these processes can also be quite predictable. For instance, on Earth water droplets placed on hydrophobic surfaces will have contact angles > 90° with limited spread, contrary to their wetting behavior on hydrophilic surfaces. However, in an environment that is in a constant state of free-fall, where the gravitational field is reduced by 10%, such as on the International Space Station (ISS), buoyancy and its effect on fluid convection also become negligible. Fluid flow and phase behavior become less predictable. Thus, continuing the prior example, even if water droplets still remain in contact with a surface in microgravity (µg), the interface between the air and droplets will still remain significantly curved, appearing almost as if they were placed over completely nonwetting surfaces (Fig. 1a). Moreover, the negligible opposing buoyant force would also mean that if immiscible liquid droplets of a less dense character, or air bubbles even (Fig. 1b), were to be suspended within a larger water drop, these immiscible droplets or air bubbles would not migrate toward any one direction unless either artificially propelled by an external force or internal reaction inducing flow.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Semi-Empirical Correlation for the Onset of Density Wave Oscillations in a Helical Coil Steam Generator

NuScale Power has completed full length helical coil steam generator (HCSG) tests at SIET Laboratories in Piacenza, Italy. The test program included an investigation of the onset and evolution of density wave oscillations (DWO). This paper describes the mechanisms leading to the onset of DWO as inferred from tests performed in the full-height TF-2 counter-flow test facility. This research supports the concept that the onset of DWO is caused by liquid bridging inside the boiling length of the tubes. Using a separate cylinders approximation, a DWO onset correlation is obtained by performing a steady-state momentum balance on the density front created by liquid bridging. This yields a momentum balance equation in terms of a set of dimensionless superficial velocities, a corresponding dimensionless pressure drop term and an average void fraction. Envelope theory is then used to obtain a critical void fraction which is substituted into the dimensionless momentum balance to obtain a DWO onset correlation similar to the Wallis counter-current flooding correlation. A comparison of the DWO onset correlation to the TF-2 DWO experimental data is presented and shows excellent agreement when the average equilibrium vapor quality is greater than 0.2.

Density Wave Oscillations, Helical Coil Steam Gene↗

Pressure Drop with Moving Contact Lines and Dynamic Contact Angles in a Hydrophobic Round Minichannel: Visualization via Synchrotron X-ray Imaging and Verification of Experimental Correlations

In hydrophobic mini- and microchannels, slug flow with moving contact lines is typically generated under various two-phase flow conditions. There is a significant pressure drop in this flow pattern with moving contact lines, which is closely related to the dynamic contact angles. Researchers have investigated dynamic contact angles experimentally for decades, but due to the limitations of visualization techniques, these experiments have typically been conducted in low Weber number regions (We < 10 –3 ). In this study, we clearly visualized the dynamic contact angles of a liquid slug in high Weber number regions (10 –3 < We <1) via synchrotron X-ray imaging with high temporal (~1000 fps) and spatial (~ 2 μm/pixel) resolutions. We precisely measured the pressure drop with moving contact lines in a hydrophobic minichannel (inner diameter = 1.018 mm). On the basis of our experimental data, we verified previous correlations for dynamic contact angles and explored the relationship between pressure drop with moving contact lines and dynamic contact angles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sound speed measurements in silver shock compressed to 300 GPa: Solid-state transition, melting, and liquid-state response

To gain insight into the thermodynamic response of shock compressed Ag states corresponding to the face-centered-cubic (fcc) to body-centered-cubic (bcc) transformation and melting observed using in-situ x-ray diffraction (XRD) measurements, we present longitudinal sound speed results and their analysis in Ag at peak stresses ranging from 60 to 300 GPa. The measured sound speeds increased linearly with density compression to 171 GPa, showing that the sound speeds (and longitudinal moduli) in the fcc and bcc phases are very similar. Between 171 and 218 GPa, the sound speed dropped significantly, consistent with the melting reported using XRD measurements in shock compressed Ag. From 218 to 300 GPa, the increasing sound speeds and Hugoniot states provide a determination of the liquid phase Ag response. In particular, determination of the Grüneisen parameter (Γ) showed that the density – Grüneisen parameter product (ρΓ) for liquid Ag is constant, but differs significantly from that for solid Ag at ambient conditions. Furthermore, the Mie- Grüneisen equation of state can be used to describe the Hugoniot and off-Hugoniot response of liquid Ag.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ACE-ENA: Fast Liquid Water Content

These data were collected during the Aerosol and Cloud Experiments in the Eastern North Atlantic field campaign as part of ARM Aerial Facility deployment (ACE-ENA, https://www.arm.gov/research/campaigns/aaf2017ace-ena). The ARM Aerial Facility Gulfstream-1 was deployed at Lajes Air Base (IATA: TER, ICAO: LPLA), on Terceira Island in the Azores, Portugal, for the two Intensive Observation Periods from June 20 through July 22, 2017 (IOP#1) and from January 11 through February 22, 2018 (IOP#2). The G-1 aircraft performed 20+19 research flights over the ARM Eastern North Atlantic (ENA) site and Atlantic Ocean to measure atmospheric turbulence, cloud water content and drop size distributions, aerosol precursor gases, aerosol chemical composition and size distributions. The current data set presents re-processed Particle Volume Monitor PVM-100A (aka Gerber probe) data: Liquid Water Content (LWC), Particle Surface Area (PSA), and the effective droplet radius (re) averaged to 50 Hz, 10 Hz, and 1 Hz.

54 ENVIRONMENTAL SCIENCES↗

From casting to 3D printing geopolymers: A proof of concept

The objective of this paper is to define a mix design strategy allowing the implementation of geopolymer in powder bed 3D printing. In a selective binder approach, an aluminosilicate powder bed is activated through the deposit of an alkaline silicate solution. We first show that, in comparison to casting, this technology requires mastering the spreading of the liquid into the powder bed to ensure that the reaction takes place where it is needed. A series of experiments at the drop level, mimicking the 3D printing process, were performed to determine the printing solution composition for a given powder bed packing. We then highlight the relationship between the compressive strength of the printed geopolymer and the powder bed saturation, controlled by the printing parameters. Finally, SEM/EDX analysis confirm the formation of geopolymer with desired Si/Al and Na/Al ratios in the resulting printed material.

36 MATERIALS SCIENCE↗

Structure of molten ytterbium aluminum garnet

Rare earth aluminum garnets are important materials in optical, dielectric, and thermal barrier applications. To advance the understanding of their melt processing and glass forming ability, we report the atomic structure of molten Yb 3 Al 5 O 12 over 1770–2630 K, which spans the equilibrium and supercooled liquid regimes. The melt density at T m = 2283 K is 5.50 g cm –3 , measured via silhouette imaging of electrostatically levitated drops over 1010–2420 K. Four separate structure measurements were made with aerodynamically levitated melts using x-ray and neutron diffraction with isotope substitution of Yb ( 172 Yb, 174 Yb, or nat Yb). Empirical potential structure refinement models were developed, which are in excellent agreement with the experiments. Coordination environments for Al–O are predominantly 4- and 5-coordinate, with a mean coordination of n AlO = 4.43(8), while Yb–O environments mostly range from 5- to 8-coordinate, with n YbO = 6.26(8). The cation–oxygen polyhedra are connected primarily by corner-sharing, with edge-sharing constituting up to ~1/3 of the connectivity among polyhedra with Yb or higher-coordinated Al–O. Structurally, the –Al–O– network in molten Yb 3 Al 5 O 12 appears conducive to glass formation: n OAl = 1.85(3), there are 1.86 AlO x –AlO x connections per Al atom (e.g., a mixture of Q 3 and Q 4 units), and the modal ring size is six cations. These characterize a network that is somewhat less constrained compared to SiO 2 glass, yet Yb 3 Al 5 O 12 cannot be quenched into crystal-free glass. Here, aluminum garnet compositions with larger rare earth cations do form glass, so these characterizations help reveal the structural characteristics corresponding to the limit of glass forming ability in rare earth aluminates.

36 MATERIALS SCIENCE↗

Formulation of autoconversion and drop spectra shape in shallow cumulus clouds

Two-moment autoconversion parameterizations as compared to accretion parameterizations exhibit significant errors suggesting that additional moments are needed to increase their accuracy. We develop a three-moment autoconversion parameterization using output from an LES model with size-resolved microphysics. Adding the third moment decreases the errors of parameterization and improves precipitation prediction. However, the errors are still significantly larger than errors of accretion rate. An analysis of the cloud drop size distributions (DSDs) in the simulated tropical convective cloud system reveals that most of DSDs have a significant fraction of cloud liquid water content (qc) in the mid-size droplet range (radii from 20 to 40 microns). Our data indicates that more than 30% of DSDs have over half of qc contained in the mid-size range and about 60% of spectra have, at least, one third of qc in this range. Even when the rain/drizzle mode is small (radar reflectivity Z < -10 dBZ), there is a significant number of spectra in which fraction of qc in the mid-size range is as large as 60%. These DSDs are more complex than the frequently used single-mode Gamma or Log-normal distributions, which usually do not have a considerable tail extending to the mid-size range and can be defined by three microphysical moments. The need to define DSDs by more than three moments explains the large errors in the three-moment autoconversion parameterization. The limitation of three-parameter Gamma or Log-normal distributions should be kept in mind when applying them in precipitating shallow Cu clouds.

Kogan, Yefim↗

Hydrodynamic instabilities and heat transfer characteristics in the duct flow of a fluid in the supercritical thermodynamic regime

The behavior of fluids at supercritical thermodynamic conditions is inherently complex due to large variations in thermodynamic and transport properties. Recent numerical and experimental investigations illustrate ongoing interest for these fluids, especially supercritical CO 2 and supercritical water, for a variety of applications. For example, supercritical water reactors (SCWR) operate in this extreme condition of high-pressure and temperature, resulting in highly dynamic flow fields and unexpected heat transfer regimes. The potential heat transfer benefits in this regime are directly associated with the extreme variations in thermodynamic and transport properties, which occur at, and above, the critical point. This work characterizes the hydrodynamic instabilities that arise for fluids at supercritical thermodynamic conditions when buoyancy forces are significant. Two specific configurations are considered, a natural convection cavity flow, and a mixed convection, heated, horizontal channel flow. Natural convection flow in a cavity is a classical configuration with expected behavior below the critical point. This configuration aids in characterizing the effect of the variable properties in the supercritical thermodynamic regime. Further, limited studies in the existing literature have been conducted for low-Reynolds and intermediate-Rayleigh numbers, mixed-convection channel flows for supercritical water, which is the focus of the channel flow configuration. To investigate the thermally driven hydrodynamic instabilities in this regime, a high-order fully-implicit numerical method is used. Such strong variations in thermophysical properties (in particular, density) are difficult to simulate and an altogether compressible framework is needed. Therefore, the compressible Navier-Stokes equations are solved without any additional assumptions. The fully implicit, high-order in space and time, reconstructed discontinuous Galerkin method as implemented within the multi-physics code called ALE3D (Arbitrary Lagrangian and Eulerian in 2D and 3D), developed at Lawrence Livermore National Laboratory (LLNL), is used. This fully implicit, L-stable method accurately captures the compressible nature of the ow in the limit of very low Mach number. It has been widely accepted that above the critical point, only one phase is observed. However, recent research has indicated the existence of the distinct gas-like and liquid-like regions separated by the Widom line, the locus of the maxima of the specific heat. Along the Widom line, density decreases 6-fold, viscosity drops by a factor of 2, while specific heat spikes by an order of magnitude. These variations, specifically in density and viscosity, produce a thick pseudo-interface and flow dynamics behavior akin to film boiling. A pseudo-film at the heated wall of the cavity and the horizontal channel is observed where buoyancy forces induce mixing through the specific configurations. Further the local Rayleigh and Richardson numbers provide maps of the flow field and the buoyancy forces driving the microscopic mixing. In the first chapter, I describe a background of supercritical fluid and the various applications. The second chapter focuses on the mathematical model and numerical method used for simulations, where a description of the equation of state for supercritical water is described. The third chapter focuses on the natural convection cavity with a heated bottom wall. In this cavity a gas-like and a liquid-like flow within the supercritical thermodynamic regime are observed. The fourth chapter focuses on a forced convection, horizontal channel, distinguishing between the gas-like, liquid-like, and mixed flow regimes. Mixed convection flow, with the addition of gravitational forces in the horizontal channel show the influence of variable properties on the hydrodynamic development, heat transfer, and rising instabilities. The last chapter of this research focuses on characterizing the unstable hydrodynamics through time-averaging processes and analysis of the movement of energy through the developing plumes.

42 ENGINEERING↗

Highly supercooled riming and unusual triple-frequency radar signatures over McMurdo Station, Antarctica

Abstract. Riming of ice crystals by supercooled water droplets is an efficient ice growth process, but its basic properties are still poorly known. While it has been shown to contribute significantly to surface precipitation at mid-latitudes, little is known about its occurrence at high latitudes. In Antarctica, two competing effects can influence the occurrence of riming: (i) the scarcity of supercooled liquid water clouds due to the extremely low tropospheric temperatures and (ii) the low aerosol concentration, which may lead to the formation of fewer and larger supercooled drops potentially resulting in an enhanced riming efficiency. In this work, by exploiting the deployment of an unprecedented number of multiwavelength remote sensing systems (including triple-frequency radar measurements) in West Antarctica, during the Atmospheric Radiation Measurements West Antarctic Radiation Experiment (AWARE) field campaign, we evaluate the riming incidence at McMurdo Station and find that riming occurs at much lower temperatures when compared to previous results in the mid-latitudes. This suggests the possible occurrence of a common atmospheric state over Antarctica that includes a rather stable atmosphere inhibiting turbulent mixing, and a high riming efficiency driven by large cloud droplets. We then focus on a peculiar case study featuring a persistent layer with a particularly pronounced riming signature in triple-frequency radar data but only a relatively modest amount of supercooled liquid water. In-depth analysis of the radar observations suggests that such signatures can only be explained by the combined effects of moderately rimed aggregates or similarly shaped florid polycrystals and a narrow particle size distribution (PSD). Simulations of this case study performed with a one-dimensional bin model indicate that similar triple-frequency radar observations can be reproduced when narrow PSDs are simulated. Such narrow PSDs can in turn be explained by two key factors: (i) the presence of a shallow homogeneous droplet or humidified aerosol freezing layer aloft seeding an underlying supercooled liquid layer, and (ii) the absence of turbulent mixing throughout a stable polar atmosphere that sustains narrow PSDs, as hydrometeors grow from the nucleation region aloft to ice particles of several millimeters in size, by vapor deposition and then riming.

54 ENVIRONMENTAL SCIENCES↗

Cryogenic Carbon Capture™ (CCC) Status Report

The Cryogenic Carbon Capture™ (CCC) process separates CO2 from light gases in essentially any continuous process. CCC cools the gases to the frost or desublimation point of CO2 (-100 to -135 °C), separates and pressurizes the solids, and warms all streams to produce a CO2-depleted stream at ambient pressure and a pure (99+%) pressurized liquid CO2 stream typically to about 150 bar, both at ambient temperature. The process also recovers all gas moisture and most gas impurities less volatile than CO2 (NOx, SOx, Hg, PM, UHC, CCC, etc.) in separable streams. CCC nearly eliminates refrigeration energy for sensible temperature changes through heat integration. CCC does require energy to change the CO2 phase from a mixed vapor to a pressurized fluid, which represents the minimum energy required of any process for this separation. CCC uses additional energy for turbomachinery inefficiencies, heat losses, moisture removal and overall process pressure drop. Aside from these real-world energy demands, CCC operates near the minimum energy required to perform this gas separation by minimizing stream recycling. CCC compresses CO2 as a liquid, which is one of several reasons it costs about about half as much and consumes about half as much energy as an amine process when using flue gases with about 15% CO2. The process also has several major additional advantages, including (a) it is a bolt-on retrofit technology that does not need steam or any modification of existing equipment, (b) it recovers water and nearly all pollutants in addition to CO2 from the flue gas, (c) it enables highly efficient and cost effective energy storage at grid scale and on time scales of minutes, (d) it enables NG storage if the energy storage option is used, and (d) it has a small footprint and is minimally disruptive to existing plants, requiring only electrical power and a gas source to operate. Sustainable Energy Solutions (SES) has scaled this technology through several levels, the largest of which captures nominally 1 tonne of CO2/day and is called the skid system. Skid system field tests include utility-scale power plants, cement plants, heating plants, and other utility or industrial sites that burn natural gas, biomass, coal, shredded tires, municipal waste, and combinations of these fuels. These field tests produced 95-99% CO2 capture with CO2 purities of 99+% and initial CO2 contents that range from 4 to 28%. SES currently seeks to scale the system to merchant scale (10-80 tonnes of CO2 per day). In the process of doing so, SES has demonstrated the potential for CCC to contribute to energy storage and direct air capture in innovative and cost-effective ways. This presentation discusses the overall process and highlights results from field and in-house tests. These include (a) measured CO2 capture rates and operating conditions from in-house and field tests, and (b) predicted utility-scale costs and energy demands. This discussion also includes the application of the CCC technology to energy storage and direct air capture.

20 FOSSIL-FUELED POWER PLANTS↗

Numerical assessment of triply periodic minimal surfaces for direct air capture of carbon dioxide

Direct air capture (DAC) systems often consist of packing material wetted by a capture fluid that reacts with CO 2 in the airstream. The efficiency of the contactor is determined by a complex relationship of fluid dynamics, heat and mass transfer, contactor geometry, and chemical properties. The efficiency of the contactor must be balanced with other factors, primarily pressure drop through the system. Triply periodic minimal surfaces (TPMS) are a class of differential surfaces that have been explored in multiple engineering applications and have been shown to exhibit excellent performance when used in heat exchangers. Their tortuous path provides a high surface-to-volume ratio and favorable trade-off between contact area and pressure drop. In this work, a gyroid-type TPMS contactor was evaluated using computational fluid dynamics for a variety of geometric parameters to explore the potential benefit of TPMS shapes for DAC applications. A thin-film model was employed to model the flow and distribution of the capture solvent, allowing efficient simulations of TPMS structures at scale by eliminating the need for a computationally intensive interface capturing method. A liquid-gas mass transfer model was implemented in the commercial software STAR-CCM+ and used to predict the CO 2 capture efficiency and study the trade-off between capture performance and pressure drop through analysis of capture rates, mass transfer coefficients, and other relevant variables. TPMS contactors with a variety of geometric parameters and two capture solvent options were investigated to determine the effect of design choices on the operational performance of DAC systems. In conclusion, results showed that while contactor geometry is the dominant factor in efficiency and pressure drop, the physiochemical properties of the solvent are an important secondary influence on the contactor performance.

CFD↗

Loop Thermosyphon Enhanced Solar Collector

A two-phase loop thermosyphon solar collector was developed to transfer thermal energy efficiently and passively from a concentrated solar collector to a thermal desalination process. The two-phase flow in the loop thermosyphon is driven by a difference in gravitational pressure head between the liquid return line and the two-phase riser located between the evaporator and condenser. A numerical model incorporating mass, energy, and pressure drop balances was developed to predict system performance and use as a design tool. Three iterations of loop thermosyphon solar collectors were designed, fabricated, and tested to validate the numerical analysis and demonstrate system integration. Additionally, a novel solar receiver design was evaluated based on volumetric absorption of the concentrated sunlight by an optically absorptive two-phase working fluid. Life tests were performed to evaluate the working fluid thermal stability and resistance to ultraviolet degradation. A glass receiver tube and associated glass-to-metal junctions were developed. Finally, a full-scale loop thermosyphon was integrated with a parabolic trough solar collector and tested on-sun.

14 SOLAR ENERGY↗

Investigating the Relative Roles of INPs and CCN in a Simulated Thunderstorm Using a New Immersion Freezing Algorithm

Microphysical processes in deep convective clouds are sensitive to the number concentrations of cloud condensation nuclei (CCN) and ice nucleating particles (INPs), but the effects of INPs are less studied. Modeling studies investigating the effects of INPs and/or CCN on deep convection typically retain a volume‐dependent raindrop freezing relation. The resulting neglect of aerosol accumulation in raindrops via drop collisions has likely produced unrealistic storm responses to INPs in past studies. To address this deficiency, a new immersion freezing algorithm was developed and embedded in a bulk microphysics scheme that freezes both cloud drops and raindrops using the same immersion freezing INP (IF‐INP) activity spectrum based on measurements. Multiple idealized simulations of a single case of deep convection observed during the Clouds, Aerosols, and Complex Terrain Interactions (CACTI) field campaign were conducted, with microphysical differences produced by independently altering IF‐INP temperature dependencies and CCN number concentrations from their observed values. Surface precipitation in all simulations resulted almost exclusively from riming graupel that melted upon descending to the surface. Rainfall and cold pools were substantially and systematically weakened with increased CCN due to decreased graupel riming rates but were relatively insensitive to variations in the magnitude and slope of IF‐INP spectra due to compensating depletion of supercooled liquid water. These compensating processes were a consequence of the accumulation of IF‐INPs in raindrops, encouraging caution in studying IF‐INP effects upon thunderstorms using traditional volume‐dependent drop freezing relationships.

CCN↗

Full Length Assembly Testing in PELICAN (Final Report)

In support of the development of the U.S. Department of Energy (DOE) Versatile Test Reactor (VTR), a thermal hydraulics test facility was constructed to generate experimental measurement of the pressure drop across a single full-scale assembly containing prototypic axial reflectors, fuel, and plena components. Constructed and operated at Argonne National Laboratory, the Pressure drop Experimental Loop for Investigations of Core Assemblies in Nuclear reactors (PELICAN) facility was designed to achieve hydraulic conditions identical to those anticipated for a full-scale fuel assembly located in the VTR core in the region with the highest flow rate. Using water as surrogate for liquid sodium, the flow loop was operated at elevated temperatures and pressures to match the thermophysical properties of liquid sodium and ensure matching Reynolds and Euler numbers. The measurement objectives for data generated from this test facility was driven primarily by the validation needs for code calculations and simulations of the reference VTR core. These objectives focused on the need to validate pressure drop results across the various segments of the fuel assembly as they relate directly to the pumping power and safety of the reactor. Presented in this report are experimental results and analytical comparisons based on testing of a full-length assembly in PELICAN. Housed within a hexagonal test section extending 3.4 m in length, the tested assembly features a prototypic lower reflector, grid plates, wire-wrapped rod bundle, upper reflector, and exit region. The rod bundle extends over 1.5 m in length and contains 217 individual wire-wrapped rods with dimensions that best reflect the reference VTR design. The as-tested bundle assembly was fabricated using 316 stainless steel 0.25-inch (6.35-mm) diameter rods wrapped with 0.04-inch (1.016-mm) diameter wire at a helical pitch of 10.51 inch (26.6 cm). Details of the method for in-house wire-wrapping, assembly, and installation are provided later in this report. Experimental measurements of pressure drop at 19 positions along the test assembly were recorded for a range of flow conditions, with special attention paid to key locations within the assembly, including component inlet and outlet, transition, and wire-wrapped rod bundle regions. Testing conditions were based on 110°C water with flow rates ranging from 50 to 450 GPM (3 to 27 kg/s) at the inlet of the test assembly generating Reynolds numbers and velocities up to ~8.0×10 4 and ~7.8 m/s, respectively, within the rod bundle region. Non-dimensional values for the friction factor were then calculated based on these experimental measurements and compared against those predicted by various analytical correlations available from open literature. Predictions by the upgraded Cheng and Todreas, Rehme, and Novendstern correlations fell within 4% to those values measured experimentally.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Design optimization of gap distance for the capillary limitation of a heat pipe with annular-type wick structure

In this study, an experimental investigation was conducted on the rising height and contact angle of fluid in an annular wick-type heat pipe. The annular wick-type heat pipe was characterized by a small gap between the wick structure and tube wall, which compensated for the pressure drop along the porous media and created additional capillary force. To describe and model the advantage of this gap, the rising of a wetting liquid in the gap between a vertical solid plate and a mesh (with a small angle between them) was experimentally measured and analyzed. An additional experiment was performed to investigate the effect of curvature on the capillary rise using tubes and meshes of varying radii. Resultantly, we confirmed that the linear combination of the contact angles of the solid plate and mesh could be applied to calculate the rising height from the Laplace–Young equation. Furthermore, the effect of curvature on the rising height of the liquid was negligible. These results were extended to the investigation of finding the optimal gap distance for the annular wick-type heat pipe by referring to previous studies. We observed that a gap distance of 1.27 mm provided the largest permeability (K) over the effective pore radius (r eff ) value for a heat pipe with ethanol, which in turn resulted in the highest capillary limitation. For a sodium heat pipe, a gap distance of 0.84 mm resulted in the highest capillary limitation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Enhancing the sensitivity of the LUX-ZEPLIN (LZ) dark matter experiment to low energy signals

Two-phase xenon detectors, such as that at the core of the forthcoming LZ dark matter experiment, use photomultiplier tubes to sense the primary (S1) and secondary (S2) scintillation signals resulting from particle interactions in their liquid xenon target. This paper describes a simulation study exploring two techniques to lower the energy threshold of LZ to gain sensitivity to low-mass dark matter and astrophysical neutrinos, which will be applicable to other liquid xenon detectors. The energy threshold is determined by the number of detected S1 photons; typically, these must be recorded in three or more photomultiplier channels to avoid dark count coincidences that mimic real signals. To lower this threshold: a) we take advantage of the double photoelectron emission effect, whereby a single vacuum ultraviolet photon has a $\sim20\%$ probability of ejecting two photoelectrons from a photomultiplier tube photocathode; and b) we drop the requirement of an S1 signal altogether, and use only the ionization signal, which can be detected more efficiently. For both techniques we develop signal and background models for the nominal exposure, and explore accompanying systematic effects, including the dependence on the free electron lifetime in the liquid xenon. When incorporating double photoelectron signals, we predict a factor of $\sim 4$ sensitivity improvement to the dark matter-nucleon scattering cross-section at $2.5$ GeV/c$^2$, and a factor of $\sim1.6$ increase in the solar $^8$B neutrino detection rate. Dropping the S1 requirement may allow sensitivity gains of two orders of magnitude in both cases. Finally, we apply these techniques to even lower masses by taking into account the atomic Migdal effect; this could lower the dark matter particle mass threshold to $80$ MeV/c$^2$.

Akerib, DS↗