Search NASA⌕ Search

SEARCH · Search NASA

Results for “LIQUID NITROGEN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System

NASA Kennedy Space Center (KSC) recently entered into a nonexclusive license agreement with Applied Cryogenic Solutions (ACS), Inc. (Galveston, TX) to commercialize its Gas-Liquid Supersonic Cleaning and Cleaning Verification Spray System technology. This technology, developed by KSC, is a critical component of processes being developed and commercialized by ACS to replace current mechanical and chemical cleaning and descaling methods used by numerous industries. Pilot trials on heat exchanger tubing components have shown that the ACS technology provides for: Superior cleaning in a much shorter period of time. Lower energy and labor requirements for cleaning and de-scaling uper.ninih. Significant reductions in waste volumes by not using water, acidic or basic solutions, organic solvents, or nonvolatile solid abrasives as components in the cleaning process. Improved energy efficiency in post-cleaning heat exchanger operations. The ACS process consists of a spray head containing supersonic converging/diverging nozzles, a source of liquid gas; a novel, proprietary pumping system that permits pumping liquid nitrogen, liquid air, or supercritical carbon dioxide to pressures in the range of 20,000 to 60,000 psi; and various hoses, fittings, valves, and gauges. The size and number of nozzles can be varied so the system can be built in configurations ranging from small hand-held spray heads to large multinozzle cleaners. The system also can be used to verify if a part has been adequately cleaned.

Parrish, Lewis M.↗

Liquid air mixing system

A device for mixing liquid nitrogen and liquid oxygen to form liquid air. The mixing device consists of a tube for transferring liquid oxygen positioned within a tube for transferring liquid nitrogen. Supply vessels for liquid oxygen and liquid nitrogen are equally pressurized and connected to the appropriate tubes. Liquid oxygen and nitrogen flow from the supply vessels through the respective tubes and are mixed to form liquid air upon exiting the outlets of the tube. The resulting liquid air is transferred to a holding vessel.

Martin, Robert B.↗

Subcritical crack growth of selected aerospace pressure vessel materials

This experimental program was undertaken to determine the effects of combined cyclic/sustained loads, stress level, and crack shape on the fatigue crack growth rate behavior of cracks subjected to plane strain conditions. Material/environment combinations tested included: 2219-T87 aluminum plate in gaseous helium, room air, and 3.5% NaCl solution at room temperature, liquid nitrogen, and liquid hydrogen; 5Al-2.5 Sn (ELI) titanium plate in liquid nitrogen and liquid hydrogen and 6AL-4V (ELI) STA titanium plate in gaseous helium and methanol at room temperature. Most testing was accomplished using surface flawed specimens instrumented with a clip gage to continuously monitor crack opening displacements at the specimen surface. Tapered double cantilever beam specimens were also tested. Static fracture and ten hour sustained load tests were conducted to determine fracture toughness and apparent threshold stress intensity values. Cyclic tests were performed using sinusoidal loading profiles at 333 MHz (20 cpm) and trapezoidal loading profiles at both 8.3 MHz (0.5 cpm) and 3.3 MHz (0.2 cpm). Data were evaluated using modified linear elastic fracture mechanics parameters.

Hall, L. R.↗

Temperature and pressure effects on capacitance probe cryogenic liquid level measurement accuracy

The inaccuracies of liquid nitrogen and liquid hydrogen level measurements by use of a coaxial capacitance probe were investigated as a function of fluid temperatures and pressures. Significant liquid level measurement errors were found to occur due to the changes in the fluids dielectric constants which develop over the operating temperature and pressure ranges of the cryogenic storage tanks. The level measurement inaccuracies can be reduced by using fluid dielectric correction factors based on measured fluid temperatures and pressures. The errors in the corrected liquid level measurements were estimated based on the reported calibration errors of the temperature and pressure measurement systems. Experimental liquid nitrogen (LN2) and liquid hydrogen (LH2) level measurements were obtained using the calibrated capacitance probe equations and also by the dielectric constant correction factor method. The liquid levels obtained by the capacitance probe for the two methods were compared with the liquid level estimated from the fluid temperature profiles. Results show that the dielectric constant corrected liquid levels agreed within 0.5 percent of the temperature profile estimated liquid level. The uncorrected dielectric constant capacitance liquid level measurements deviated from the temperature profile level by more than 5 percent. This paper identifies the magnitude of liquid level measurement error that can occur for LN2 and LH2 fluids due to temperature and pressure effects on the dielectric constants over the tank storage conditions from 5 to 40 psia. A method of reducing the level measurement errors by using dielectric constant correction factors based on fluid temperature and pressure measurements is derived. The improved accuracy by use of the correction factors is experimentally verified by comparing liquid levels derived from fluid temperature profiles.

Edwards, Lawrence G.↗

A Generalized Multi-Phase Framework for Modeling Cavitation in Cryogenic Fluids

A generalized multi-phase formulation for cavitation in fluids operating at temperatures elevated relative to their critical temperatures is presented. The thermal effects and the accompanying property variations due to phase change are modeled rigorously. Thermal equilibrium is assumed and fluid thermodynamic properties are specified along the saturation line using the NIST-12 databank. Fundamental changes in the physical characteristics of the cavity when thermal effects become pronounced are identified; the cavity becomes more porous, the interface less distinct, and has increased entrainment when temperature variations are present. Quantitative estimates of temperature and pressure depressions in both liquid nitrogen and liquid hydrogen were computed and compared with experimental data of Hord for hydrofoils. Excellent estimates of the leading edge temperature and pressure depression were obtained while the comparisons in the cavity closure region were reasonable. Liquid nitrogen cavities were consistently found to be in thermal equilibrium while liquid hydrogen cavities exhibited small, but distinct, non-equilibrium effects.

Dorney, Dan↗

Mount makes liquid nitrogen-cooled gamma ray detector portable

Liquid nitrogen-cooled gamma ray detector system is made portable by attaching the detector to a fixture which provides a good thermal conductive path between the detector and the liquid nitrogen in a dewar flask and a low heat leak path between the detector and the external environment.

Fessler, T. E.↗

Brush Seals for Cryogenic Applications: Performance, Stage Effects, and Preliminary Wear Results in LN2 and LH2

Brush seals are compliant contacting seals and have significantly lower leakage than labyrinth seals in gas turbine applications. Their long life and low leakage make them candidates for use in rocket engine turbopumps. Brush seals, 50.8 mm (2 in.) in diameter with a nominal 127-micron (0.005-in.) radial interference, were tested in liquid nitrogen (LN2) and liquid hydrogen (LH2) at shaft speeds up to 35,000 and 65,000 rpm, respectively, and at pressure drops up to 1.21 MPa (175 psid) per brush. A labyrinth seal was also tested in liquid nitrogen to provide a baseline. The LN2 leakage rate of a single brush seal with an initial radial shaft interference of 127 micron (0.005 in.) measured one-half to one-third the leakage rate of a 12-tooth labyrinth seal with a radial clearance of 127 micron (0.005 in.). Two brushes spaced 7.21 micron (0.248 in.) apart leaked about one-half as much as a single brush, and two brushes tightly packed together leaked about three-fourths as much as a single brush. The maximum measured groove depth on the Inconel 718 rotor with a surface finish of 0.81 micron (32 microinch) was 25 micron (0.0010 in.) after 4.3 hr of shaft rotation in liquid nitrogen. The Haynes-25 bristles wore approximately 25 to 76 micron (0.001 to 0.003 in.) under the same conditions. Wear results in liquid hydrogen were significantly different. In liquid hydrogen the rotor did not wear, but the bristle material transferred onto the rotor and the initial 127 micron (0.005 in.) radial interference was consumed. Relatively high leakage rates were measured in liquid hydrogen. More testing is required to verify the leakage performance, to validate and calibrate analysis techniques, and to determine the wear mechanisms. Performance, staging effects, and preliminary wear results are presented.

Proctor, Margaret P.↗

Investigation of flaw geometry and loading effects on plane strain fracture in metallic structures

The effects on fracture and flaw growth of weld-induced residual stresses, combined bending and tension stresses, and stress fields adjacent to circular holes in 2219-T87 aluminum and 5AI-2.5Sn(ELI) titanium alloys were evaluated. Static fracture tests were conducted in liquid nitrogen; fatigue tests were performed in room air, liquid nitrogen, and liquid hydrogen. Evaluation of results was based on linear elastic fracture mechanics concepts and was directed to improving existing methods of estimating minimum fracture strength and fatigue lives for pressurized structure in spacecraft and booster systems. Effects of specimen design in plane-strain fracture toughness testing were investigated. Four different specimen types were tested in room air, liquid nitrogen and liquid hydrogen environments using the aluminum and titanium alloys. Interferometry and holograph were used to measure crack-opening displacements in surface-flawed plexiglass test specimens. Comparisons were made between stress intensities calculated using displacement measurements, and approximate analytical solutions.

Hall, L. R.↗

Thermal vacuum chamber shroud performance with gaseous nitrogen cooling

The results are presented for calculations of shroud surface temperature for various flow rates of gaseous nitrogen through the liquid nitrogen shrouds of a large thermal vacuum chamber. The conditions imposed provide conservative bounds for Mars surface simulation inside the chamber during thermal testing of an appropriate test object. It is shown that the shroud surfaces seen by the object can be held within an acceptable temperature range by providing a reasonable flow of gaseous nitrogen to the shrouds at a reasonable pressure, and that no change to the present shroud system need be made which would affect its suitability for liquid nitrogen cooling.

Farmer, R. A.↗

Cryo-mechanical tests of Ames 24E2 IR-black coating

In addition to the ambient condition tape test, five mechanical tests of the IR-black coating, Ames 24E2, were performed at either liquid helium or liquid nitrogen temperatures. Tensile strain in the coating at liquid nitrogen temperature was measured up to values of 4E-3, both before and after the coating was cycled down to liquid helium temperature. When applied to an aluminum substrate which was then bent in liquid nitrogen, the aluminum substrate always failed (permanently deformed) well before the coating failed. Sinusoidal accelerations up to 45 Gs in liquid nitrogen and 25 Gs in liquid helium did not crack or otherwise visibly damage the coating. Both sinusoidal and random acceleration at about 90 K of a representative baffle vane structure, at frequencies from 10 to 2000 Hz and up to 15 Gs, did not damage the coating, even at the intersection of a baffle with the telescope tube. Thus on a macroscopic level, cryogenic cooling and various levels of acceleration and strain did not affect this coating. However, on a microscopic scale, some loose particles were found associated with several tests. Outgassing data are also given.

Smith, Sheldon M.↗

Cryo-mechanical tests of Ames 24E2 IR-black coating

In addition to the ambient condition tape test, five mechanical tests of the IR-black coating, Ames 24E2, were performed at either liquid helium or liquid nitrogen teperatures. Tensile strain in the coating at liquid nitrogen temperature was measured up to values of 4E-3, both before and after the coating was cycled down to liquid helium temperature. When applied to an aluminum substrate which was then bent in liquid nitrogen, the aluminum substrate always failed (permanently deformed) well before the coating failed. Sinusoidal accelerations up to 45 Gs in liquid nitrogen and 25 Gs in liquid helium did not crack or otherwise visibly damage the coating. Both sinusoidal and random acceleration at about 90 K of a representative baffle vane structure, at frequencies from 10 to 2000 Hz and up to 15 Gs, did not damage the coating, even at the intersection of a baffle with the telescope tube. Thus on a macroscopic level, cryogenic cooling and various levels of acceleration and strain did not affect this coating. However, on a microscopic scale, some loose particles were found associated with several tests. Outgassing data are also given

Smith, Sheldon M.↗

Recovering Trichloroethane From Nitrogen Gas

Trichloroethane condensed in liquid nitrogen. Manifold promotes condensation of trichloroethane. Each U-shaped sections packed with pall rings to increase contact area and create turbulence for increased transfer of heat to liquid nitrogen that normally fills tank. Useful where hardware is cleaned with trichloroethane solvent, then dried with hot nitrogen gas. Hot gas absorbs some solvent, and if gas is simply released to atmosphere, entrained solvent constitutes health hazard and contributes depletion of ozone.

Shepard, Timothy S.↗

Preliminary Study of a Piston Pump for Cryogenic Fluids

Preliminary data are presented covering the performance of a low-speed, five-cylinder piston pump designed for handling boiling hydrogen. This pump was designed for a flow of 55 gallons per minute at 240 rpm with a discharge pressure of 135 pounds per square inch. Tests were made using JP-4 fuel, liquid nitrogen, and liquid hydrogen. Pump delivery and endurance characteristics were satisfactory for the range of operation covered. In connection with the foregoing pump development, the cavitation characteristics of a preliminary visual model, glass-cylinder pump and of a simple reciprocating disk were studied. Subcooling of approximately 0.60 F was obtained from the cavitation produced by reciprocating a disk in boiling nitrogen and in boiling water. The subcooling obtained in a similar manner with liquid hydrogen was somewhat less.

Biermann, Arnold E.↗

Onset of condensation effects as detected by total pressure probes in the Langley 0.3-meter transonic cryogenic tunnel

Total pressure probes mounted in the test section of a 0.3 meter transonic cryogenic tunnel were used to detect the onset of condensation effects for free stream Mach numbers of 0.50, 0.75, 0.85, and 0.95 and for total pressure between one and five atmospheres. The amount of supercooling was found to be about 3 K and suggests that condensation was occurring on pre-existing liquid nitrogen droplets resulting from incomplete evaporation of the liquid nitrogen injected to cool the tunnel. The liquid nitrogen injection process presently being used for the 0.3 m tunnel was found to result in a wide spectrum of droplet sizes being injected into the flow. Since the relatively larger droplets took much more time to evaporate than the more numerous smaller droplets, the larger ones reached the test section first as the tunnel operating temperature was reduced. However, condensation effects in the test section were not immediately measurable because there was not a sufficient number of the larger droplets to have an influence on the thermodynamics of the flow.

Hall, R. M.↗

Advanced Coating Removal Techniques

An important step in the repair and protection against corrosion damage is the safe removal of the oxidation and protective coatings without further damaging the integrity of the substrate. Two such methods that are proving to be safe and effective in this task are liquid nitrogen and laser removal operations. Laser technology used for the removal of protective coatings is currently being researched and implemented in various areas of the aerospace industry. Delivering thousands of focused energy pulses, the laser ablates the coating surface by heating and dissolving the material applied to the substrate. The metal substrate will reflect the laser and redirect the energy to any remaining protective coating, thus preventing any collateral damage the substrate may suffer throughout the process. Liquid nitrogen jets are comparable to blasting with an ultra high-pressure water jet but without the residual liquid that requires collection and removal .As the liquid nitrogen reaches the surface it is transformed into gaseous nitrogen and reenters the atmosphere without any contamination to surrounding hardware. These innovative technologies simplify corrosion repair by eliminating hazardous chemicals and repetitive manual labor from the coating removal process. One very significant advantage is the reduction of particulate contamination exposure to personnel. With the removal of coatings adjacent to sensitive flight hardware, a benefit of each technique for the space program is that no contamination such as beads, water, or sanding residue is left behind when the job is finished. One primary concern is the safe removal of coatings from thin aluminum honeycomb face sheet. NASA recently conducted thermal testing on liquid nitrogen systems and found that no damage occurred on 1/6", aluminum substrates. Wright Patterson Air Force Base in conjunction with Boeing and NASA is currently testing the laser remOval technique for process qualification. Other applications of liquid nitrogen operations include cutting of both soft and hard materials. While the laser will not cut materials, it can be used to roughen surfaces and to remove other materials from the substrate including oil, grease, and mold. The space program can benefit from several of these applications with the need for precise removal of coatings and other organic compounds in areas adjacent to sensitive space flight hardware. Significant advantages are evident when comparing liquid nitrogen and laser removal operations over current techniques of media blasting and sanding.

Seibert, Jon↗

Moessbauer studies on LaNi(4.7)Sn(0.3) and its hydride

Moessbauer measurements were made on LaNi(4.7)Sn(0.3) at room and liquid nitrogen temperatures. Experimental data yielded a singlet at room temperature and a doublet at liquid-nitrogen temperature. Spectra of the hydrided sample yielded a doublet at liquid-nitrogen temperature with an increase in the quadrupole splitting compared to the unhydrided spectra, but no change in the isomer shift. These data indicate that there is no significant interaction between the tin and the hydrogen. The magnetic character remained the same down to liquid-nitrogen temperature as evidenced by the Moessbauer data. X-ray diffraction measurements on the hydride showed an expanded lattice with the same structure as found for the unhydrided sample. A decrease in particle size was observed upon hydriding.

Oliver, F. W.↗