Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Detection of astrophysical neutrinos at prospective locations of dark matter detectors

We study the prospects for detection of solar, atmospheric neutrino, and diffuse supernova neutrino background (DSNB) fluxes at future large-scale dark matter detectors through both electron and nuclear recoils. We specifically examine how the detection prospects change for several prospective detector locations [Sanford Underground Research Facility (SURF), SNOlab, Gran Sasso, China Jinping Underground Laboratory (CJPL), and Kamioka] and improve upon the statistical methodologies used in previous studies. Because of its ability to measure lower neutrino energies than other locations, we find that the best prospects for the atmospheric neutrino flux are at the SURF location, while the prospects are weakest at CJPL because it is restricted to higher neutrino energies. On the contrary, the prospects for the DSNB are best at CJPL, due largely to the reduced atmospheric neutrino background at this location. Including full detector resolution and efficiency models, the CNO component of the solar flux is detectable via the electron recoil channel with exposures of ∼ 10 3 ton-yr for all locations. These results highlight the benefits for employing two detector locations, one at high and one at low latitude. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

SU-E-T-170: Characterization of the Location, Extent, and Proximity to Critical Structures of Target Volumes Provides Detail for Improved Outcome Predictions Among Pancreatic Cancer Patients

Purpose: In radiotherapy, size, location and proximity of the target to critical structures influence treatment decisions. It has been shown that proximity of the target predicts dosimetric sparing of critical structures. In addition to dosimetry, precise location of disease has further implications such as tumor invasion, or proximity to major arteries that inhibit surgery. Knowledge of which patients can be converted to surgical candidates by radiation may have high impact on future treat/no-treat decisions. We propose a method to improve our characterization of the location of pancreatic cancer and treatment volume extent with respect to nearby arteries with the goal of developing features to improve clinical predictions and decisions. Methods: Oncospace is a local learning health system that systematically captures clinical outcomes and all aspects of radiotherapy treatment plans, including overlap volume histograms (OVH) – a measure of spatial relationships between two structures. Minimum and maximum distances of PTV and OARs based on OVH, PTV volume, anatomic location by ICD-9 code, and surgical outcome were queried. Normalized distance to center from the left and right kidney was calculated to indicate tumor location and laterality. Distance to critical arteries (celiac, superior mesenteric, common hepatic) is validated by surgical status (borderline resectable, locally advanced converted to resectable). Results: There were 205 pancreas stereotactic body radiotherapy patients treated from 2009–2015 queried. Location/laterality of tumor based on kidney OVH show strong trends between location by OVH and by ICD-9. Compared to the locally advanced group, the borderline resectable group showed larger geometrical distance from critical arteries (p=0.03). Conclusion: Our platform enabled analysis of shape/size-location relationships. These data suggest that PTV volume and attention to distance between PTVs and surrounding OARs and major arteries may be promising for improving characterization of treatment anatomy that can refine our ability for outcome predictions and decision making. Elekta, Toshiba.

60 APPLIED LIFE SCIENCES↗

A Variational Method for Analyzing Vortex Flows in Radar-Scanned Tornadic Mesocyclones. Part III: Sensitivities to Vortex Center Location Errors

Abstract When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an important issue concerning the sensitivities of analyzed vortex flow (VF) fields by the VF-Var (formulated in Part I of this paper series and tested in Part II) to vortex center location errors, denoted by Δ x c . Numerical experiments are performed to address this issue with the following findings: The increase of |Δ x c | from zero to a half of vortex core radius causes large analysis error increases in the vortex core but the increased analysis errors decrease rapidly away from the vortex core especially for dual-Doppler analyses. The increased horizontal-velocity errors in the vortex core are mainly in the Δ x c -normal component, because this component varies much more rapidly than the other component along the Δ x c direction in the vortex core. The vertical variations of Δ x c distort the vertical correlation structure of Δ x c -dislocated VF-dependent background error covariance, which can increase the analysis errors in the vortex core. The dual-Doppler analyses have adequate accuracies outside the vortex core even when |Δ x c | increases to a half of vortex core radius, while single-Doppler analyses can also have adequate accuracies outside the vortex core mainly for the single-Doppler-observed velocity component. The sensitivities to Δ x c are largely unaffected by the vortex slanting. The above findings are important and useful for assessing the accuracies of analyzed VFs for real radar-observed tornadic mesocyclones. Significance Statement When the vortex center location is estimated from a radar-scanned tornadic mesocyclone, the estimated location is not error-free. This raises an issue concerning the sensitivity of analyzed vortex flow (VF) by the VF-Var (formulated in Part I of this paper series and tested with simulated radar observations in Part II) to vortex center location error. This issue and its required investigations are very important for the VF-Var to be applied to real radar-observed tornadic mesocyclones, especially in an operational setting with the WSR-88Ds. Numerical experiments are performed to address this issue. The findings from these experiments are important and useful for assessing the accuracies of VF-Var analyzed VF fields for real radar-observed tornadic mesocyclones.

Xu, Qin↗

Geometric Interpretation of the Cluster Location Problem Part II: Application to the Pahala, Hawaii, Earthquake Sequence

In the companion “Theory” article, we presented a new framing of the seismic location problem in terms of differential geometry (Harris et al., 2025). From that viewpoint, we developed a “project and correct” approach for estimating the relative locations of earthquakes. Here, in this study, we use project and correct to estimate high-precision relative locations of events from an earthquake sequence beneath the town of Pahala, Hawaii, using high-precision correlation-derived picks. The sequence was active from 2020 through 2022 and produced many highly correlated signals at Hawaii Volcano Observatory (HVO) stations on the island of Hawaii. The data we inverted consisted of 2882 events with observations at 5 HVO stations. For comparison with the travel-time image, we also produced conventional hypocenter solutions using both the Bayesloc program (Myers et al., 2007, 2009) and a purpose-built double-difference code. There were obvious structural elements in the resulting image, the resolution of which we used to test the performance of the project and the correct algorithm. For the projection step, we first produced a 3D local basis using an singular value decomposition (SVD) of the 2882 groups of times. Projection of the travel-time vectors into this basis resulted in an image with structures similar to those produced by our conventional locators, but with distortion as predicted by theory. Removing the distortion requires an inverse operator generated from the metric tensor at the geometric centroid of the events. We compared two approaches to obtaining such an inverse operator. The first uses an estimate of the geographic centroid of the event cloud from the centroid of the travel-time data. The second approach uses the centroid of the conventionally produced locations. The first approach produces a corrected image very similar to the conventional results, but with a rotation. The corrected image produced using the conventionally derived centroid is a near-exact match to the conventional locations.

Dodge, Douglas A. [Lawrence Livermore National Lab↗

Absolute Locations of the North Korean Nuclear Tests Based on Differential Seismic Arrival Times and InSAR

Absolute location of the announced Democratic People’s Republic of Korea (DPRK) nuclear test on 6 January 2016 is constrained by fitting associated, Interferometric Synthetic Aperture Radar (InSAR)-based ground displacement with elastic finite-element modeling of an underground explosion source, including the effects of topography. The other five announced nuclear tests are located using arrival times and differential arrival times of regional and teleseismic body waves and constraints on the 6 January 2016 event location. Nuclear tests on 6 January 2016, 9 September 2016, and 3 September 2017 are under the summit ridge of Mt. Mantap, and tests on 25 May 2009 and 12 February 2013 are south of the topographic crest under the steep southern face of the mountain. The first test on 9 October 2006 was located near the crest of a separate topographic ridge approximately 2.87 km east of the 6 January 2016 event. Several unannounced events have occurred in the vicinity of the test site. The location uncertainty ellipse of an event approximately 8 min 30 s after the 2017 announced test covers the DPRK test site and is likely to have occurred there. Finally, additional events on 27 September 2017 and 12 October 2017 are 4–8 km northwest of the test site, and location probability regions do not overlap the test site.

58 GEOSCIENCES↗

Assessment of the 3420 Building Filtered Exhaust Stack Sampling Probe Location: Stack Verification Following Fan and Air Blender Additions

The Pacific Northwest National Laboratory (PNNL) 3420 Building, which is part of the Physical Sciences Facility (PSF), houses radiological capabilities that results in the requirement that emissions monitoring must be conducted for potential radionuclides in the exhaust air discharge of this building. The air monitoring system is required to conform to Title 40 of the Code of Federal Regulations part 61 (40 CFR 61) Subpart H, which in turns requires a sampling probe in the exhaust stream to conform to the criteria of American National Standards Institute / Health Physics Society (ANSI/HPS) N13.1-2011, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. To support the air emissions permit for the 3420 Building on the PNNL campus, stack testing that used computational fluid dynamics (CFD) modeling as a surrogate stack and verification tests of velocity uniformity and flow angle on the retrofitted facility stack was performed. The ANSI/HPS N13.1-2011 criteria for the air monitoring probe location are that velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%COV. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20°. The CFD modeling of the stack, as reported by Recknagle et al. (2018) demonstrated that the stack meets the criteria at the probe location. The velocity uniformity and flow angle results from the 3420 stack verification tests, performed in October 2020, demonstrated that the CFD model results may be used to support the qualification of the stack sampling location. The measured velocity uniformity verification test result was 1.4%COV. This value is well within the uniformity criterion, which is that the velocity uniformity be =20%COV. Additionally, this value is well within the criterion that the actual stack measurement must be within 5% of the surrogate stack result of 2.1%COV when all four fans were operating. Additionally, the measured average flow angle at the 3420 stack monitor location was 15.5 degrees. Although this is higher than expected based on the CFD model, the result is =20 degrees, so the criterion is met. Based on these stack verification test results, the reconfigured 3420 Building filtered exhaust stack meets the qualification criteria given in the ANSI/HPS N13.1-2011 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the CFD report (Recknagle et al., 2018) may require additional tests and additional analysis to determine compliance with the standard.

3420 Building↗

Review of the November 11, 1905 Earthquake: Seismic Intensity Data, Magnitude, and Location Report

The macroseismic location and magnitude of the Shoshone 1905 earthquake has been based on the application of objective and quantitative approaches that produce estimates of earthquake source location and magnitude, and associated uncertainties. The performance of all three approaches applied depends critically on the characteristics of the seismic intensity field. Regional intensity attenuation relations were derived based on a calibration set of earthquakes and then, the procedure was validated using three independent very recent events. The macroseismic epicenter location was determined by either a grid search procedure, the spatial distribution of the sites experiencing the largest intensities, or a combination of both. The macroseismic magnitude estimates are based on the derived regional intensity attenuation relations. There is consistency in the location and magnitude of the November 1905 earthquake as obtained by the three methods. The overlapping region of the 68% bootstrap resampling solutions suggests a reliable epicenter location within 41.550N ? 42.060N and 113.478W ? 112.320W. This region encloses the original Oaks (1992) epicenter location. Macroseismic magnitude estimates range between 5.87 and 6.05.

58 GEOSCIENCES↗

Locating Seismic Events with Local-Distance Data

As the seismic monitoring community advances toward detecting, identifying, and locating ever-smaller natural and anthropogenic events, the need is constantly increasing for higher resolution, higher fidelity data, models, and methods for accurately characterizing events. Local-distance seismic data provide robust constraints on event locations, but also introduce complexity due to the significant geologic heterogeneity of the Earth’s crust and upper mantle, and the relative sparsity of data that often occurs with small events recorded on regional seismic networks. Identifying the critical characteristics for improving local-scale event locations and the factors that impact location accuracy and reliability is an ongoing challenge for the seismic community. Using Utah as a test case, we examine three data sets of varying duration, finesse, and magnitude to investigate the effects of local earth structure and modeling parameters on local-distance event location precision and accuracy. We observe that the most critical elements controlling relocation precision are azimuthal coverage and local-scale velocity structure, with tradeoffs based on event depth, type, location, and range.

42 ENGINEERING↗

Incorporating new locations into a hydrodynamic model using ArcGIS Pro

ALGE3D is a 3-D hydrodynamic model developed at the Savannah River National Laboratory to predict pollutant dispersion. The model has several predefined locations incorporated, however adding new locations into ALGE3D is manually intensive and time-consuming. In the event of an emergency, ALGE3D can only be used if an event occurs at one of the predefined locations incorporated into the GUI. This project focuses on streamlining the integration of new locations into ALGE3D by utilizing tools in ArcGIS Pro. The Stream Order tool was used to delineate streams and assign them an order, using the Strahler method, versus manually defining these streams in Microsoft Excel. This work advances development to turn ALGE3D into a product for emergency response use by allowing the user to incorporate a new location into ALGE3D quickly, should an event occur at a location that is not already predefined.

54 ENVIRONMENTAL SCIENCES↗

Update of Receptor Locations for INL National Emissions Standard for Hazardous Air Pollutants (NESHAP) Assessments

This report documents the selection of updated public receptor locations for use in conducting regulatory assessments of radioactive air emissions for Idaho National Laboratory (INL) facilities. The basis for this receptor location analysis is found in 40 CFR 61 Subpart H, “National Emissions Standards for Emissions of Radionuclide Other than Radon from Department of Energy Facilities,” where the requirements for identifying National Emission Standards for Hazardous Air Pollutants (NESHAP) receptor locations are outlined. Receptor locations (residences, schools, businesses, or farm operations) were identified using high-resolution satellite imagery. This assessment identified 31 unique receptor locations for all INL Site facilities, and 30 receptor locations for INL in-town facilities that have the potential to emit radioactive materials. Identification of receptors for each in-town facility is new to this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Commercial and Residential Hourly Load Profiles for all TMY3 Locations in the United States

Note: This dataset has been superseded by the dataset found at "End-Use Load Profiles for the U.S. Building Stock" (submission 4520; linked in the submission resources), which is a comprehensive and validated representation of hourly load profiles in the U.S. commercial and residential building stock. The End-Use Load Profiles project website includes links to data viewers for this new dataset. For documentation of dataset validation, model calibration, and uncertainty quantification, see Wilson et al. (2022). These data were first created around 2012 as a byproduct of various analyses of solar photovoltaics and solar water heating (see references below for are two examples). This dataset contains several errors and limitations. It is recommended that users of this dataset transition to the updated version of the dataset posted in the resources. This dataset contains weather data, commercial load profile data, and residential load profile data. Weather The Typical Meteorological Year 3 (TMY3) provides one year of hourly data for around 1,000 locations. The TMY weather represents 30-year normals, which are typical weather conditions over a 30-year period. Commercial The commercial load profiles included are the 16 ASHRAE 90.1-2004 DOE Commercial Prototype Models simulated in all TMY3 locations, with building insulation levels changing based on ASHRAE 90.1-2004 requirements in each climate zone. The folder names within each resource represent the weather station location of the profiles, whereas the file names represent the building type and the representative city for the ASHRAE climate zone that was used to determine code compliance insulation levels. As indicated by the file names, all building models represent construction that complied with the ASHRAE 90.1-2004 building energy code requirements. No older or newer vintages of buildings are represented. Residential The BASE residential load profiles are five EnergyPlus models (one per climate region) representing 2009 IECC construction single-family detached homes simulated in all TMY3 locations. No older or newer vintages of buildings are represented. Each of the five climate regions include only one heating fuel type; electric heating is only found in the Hot-Humid climate. Air conditioning is not found in the Marine climate region. One major issue with the residential profiles is that for each of the five climate zones, certain location-specific algorithms from one city were applied to entire climate zones. For example, in the Hot-Humid files, the heating season calculated for Tampa, FL (December 1 - March 31) was unknowingly applied to all other locations in the Hot-Humid zone, which restricts heating operation outside of those days (for example, heating is disabled in Dallas, TX during cold weather in November). This causes the heating energy to be artificially low in colder parts of that climate zone, and conversely the cooling season restriction leads to artificially low cooling energy use in hotter parts of each climate zone. Additionally, the ground temperatures for the representative city were used across the entire climate zone. This affects water heating energy use (because inlet cold water temperature depends on ground temperature) and heating/cooling energy use (because of ground heat transfer through foundation walls and floors). Representative cities were Tampa, FL (Hot-Humid), El Paso, TX (Mixed-Dry/Hot-Dry), Memphis, TN (Mixed-Humid), Arcata, CA (Marine), and Billings, MT (Cold/Very-Cold). The residential dataset includes a HIGH building load profile that was intended to provide a rough approximation of older home vintages, but it combines poor thermal insulation with larger house size, tighter thermostat setpoints, and less efficient HVAC equipment. Conversely, the LOW building combines excellent thermal insulation with smaller house size, wider thermostat setpoints, and more efficient HVAC equipment. However, it is not known how well these ...

Array↗

Aerodynamic Forces and Moments on a Large Ogive-Cylinder Store at Various Locations Below the Fuselage Center Line of a Swept-Wing Bomber Configuration at a Mach Number of 1.61

A supersonic wind-tunnel investigation on store interference has been conducted in the Langley 4- by 4-foot supersonic pressure tunnel at a Mach number of 1.61. Forces and moments were measured on a large ogive-cylinder store in the presence of a 45 deg swept-wing-fuselage bomber configuration for a number of store locations below the fuselage center line. Results of the investigation show that large variations of store lift, drag, and pitch occur with changes in store or airplane angle of attack, store vertical location, and store horizontal location. The variation of the store forces and moments with respect to the chordwise location of the wing plan form indicates that the wing is a large factor in producing the interference loads on the store. Comparison of data for underfuselage and underwing store locations at an angle of attack of 0 deg showed maximum store drag interferences of similar magnitudes, but showed considerably smaller maximum interference on store lift an pitching moments for underfuselage store locations.

SUPERSONIC FLIGHT↗

Study of advanced system for position location and navigation

Concepts are investigated for improving location precision and system capacity relative to current satellite based data collection and location systems. The TRILOC concept provides either or both improvements in location and system capacity by utilizing three measurements acquired during a single transmission from a platform for location purposes. The location algorithm is developed, and range differences are measured onboard the satellite. An error analysis then relates platform location errors to the precision with which the measurements are made. The second concept is to increase system capacity by means of directive antennas onboard the satellite for reducing interference and/or reducing platform power. The potential advantages and disadvantages of both sweeping and fixed directive antennas for random access systems are evaluated.

Source record↗

The sensitivity of fracture location distribution in brittle materials

The Weibull weak-link theory allows for the computation of distribution functions for both the fracture location and the applied far-field stress. Several authors have suggested using the fracture location information from tests to infer Weibull parameters, and others have used the predictive capabilities of the theory to calculate average fracture locations for brittle bodies. By a simple set of example calculations, it is shown that the fracture location distribution function is distinctly more sensitive to perturbations in the stress state than the fracture stress distribution function is. In general, the average fracture location is more subject to stress perturbations than the average fracture stress. The results indicate that care must be exercised in applying fracture location theory.

Wetherhold, Robert C.↗

GIS modeling of archaeological site locations: A low-tech approach

A Geographic Information System (GIS)-type analysis of archaeological site locations using a dBase III plus program and a desk top computer is presented. A previously developed model of site locations in the Sequatchie Valley of northeastern Alabama is tested against known site locations in another large survey area there. The model fails to account for site locations in the test area. A model is developed for the test area and indicates the site locations are indeed different. Whether this is due to differences in site locations on a sub-regional level, or to sample error in the original model is unknown.

Futato, Eugene M.↗

Development of an accurate transmission line fault locator using the global positioning system satellites

A highly accurate transmission line fault locator based on the traveling-wave principle was developed and successfully operated within B.C. Hydro. A transmission line fault produces a fast-risetime traveling wave at the fault point which propagates along the transmission line. This fault locator system consists of traveling wave detectors located at key substations which detect and time tag the leading edge of the fault-generated traveling wave as if passes through. A master station gathers the time-tagged information from the remote detectors and determines the location of the fault. Precise time is a key element to the success of this system. This fault locator system derives its timing from the Global Positioning System (GPS) satellites. System tests confirmed the accuracy of locating faults to within the design objective of +/-300 meters.

Lee, Harry↗

The Locations of Gamma-Ray Bursts Measured by Comptel

The COMPTEL instrument on the Compton Gamma Ray Observatory is used to measure the locations of gamma-ray bursts through direct imaging of MeV photons. In a comprehensive search, we have detected and localized 29 bursts observed between 1991 April 19 and 1995 May 31. The average location accuracy of these events is 1.25 deg (1 sigma), including a systematic error of approx. 0.5 deg, which is verified through comparison with Interplanetary Network (IPN) timing annuli. The combination of COMPTEL and IPN measurements results in locations for 26 of the bursts with an average "error box" area of only approx. 0.3 deg (1 sigma). We find that the angular distribution of COMPTEL burst locations is consistent with large-scale isotropy and that there is no statistically significant evidence of small-angle autocorrelations. We conclude that there is no compelling evidence for burst repetition since no more than two of the events (or approx. 7% of the 29 bursts) could possibly have come from the same source. We also find that there is no significant correlation between the burst locations and either Abell clusters of galaxies or radio-quiet quasars. Agreement between individual COMPTEL locations and IPN annuli places a lower limit of approx. 100 AU (95% confidence) on the distance to the stronger bursts.

Kippen, R. Marc↗

The Error Distribution of BATSE Gamma-Ray Burst Locations

Empirical probability models for BATSE gamma-ray burst (GRB) location errors are developed via a Bayesian analysis of the separations between BATSE GRB locations and locations obtained with the Interplanetary Network (IPN). Models are compared and their parameters estimated using 392 GRBs with single IPN annuli and 19 GRBs with intersecting IPN annuli. Most of the analysis is for the 4Br BATSE catalog; earlier catalogs are also analyzed. The simplest model that provides a good representation of the error distribution has 78% of the probability in a "core" term with a systematic error of 1.85 deg and the remainder in an extended tail with a systematic error of 5.1 deg, which implies a 68% confidence radius for bursts with negligible statistical uncertainties of 2.2 deg. There is evidence for a more complicated model in which the error distribution depends on the BATSE data type that was used to obtain the location. Bright bursts are typically located using the CONT data type, and according to the more complicated model, the 68% confidence radius for CONT-located bursts with negligible statistical uncertainties is 2.0 deg.

Briggs, Michael S.↗