Search NASA⌕ Search

SEARCH · Search NASA

Results for “LOCATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

LATTE: open-source, high-performance traveltime computation, tomography and source location in acoustic and elastic media

Traveltime-based tomography and source location are fundamental approaches for imaging subsurface structures and understanding the spatiotemporal distribution of seismicity from local to global scales. We present an open-source, high-performance framework integrating eikonal equation solvers and adjoint-state theory for traveltime computation, velocity tomography, source location and joint tomography-location in 2-D/3-D acoustic and elastic media. We introduce novel regularization schemes based on total generalized p-variation, structural similarity and multitask machine learning to enhance the fidelity and interpretability of inverted models and source locations. Key features of our implementation also include the ability to leverage both absolute-difference and double-difference traveltime misfits for high-fidelity velocity tomography and source parameter estimation; support for traveltime computation and inversion in diverse 2-D/3-D scenarios with arbitrary source and receiver distributions; and a perturbation-based optimal step-size estimation method to reduce computational costs. In addition, our implementation employs shared-memory and distributed-memory parallelization to provide an efficient solution for traveltime computation, tomography, and source location. In conclusion, we validate the efficacy and accuracy of our approach through multiple synthetic data examples.

58 GEOSCIENCES↗

Location-oblivious data transfer with flying entangled qudits

We present a simple and practical quantum protocol involving two mistrustful agencies in Minkowski space, which allows Alice to transfer data to Bob at a space-time location that neither can predict in advance. The location depends on both Alice's and Bob's actions. The protocol guarantees unconditionally to Alice that Bob learns the data at a randomly determined location; it guarantees to Bob that Alice will not learn the transfer location even after the protocol is complete. The task implemented, transferring data at a space-time location that remains hidden from the transferrer, has no precise analog in nonrelativistic quantum cryptography. It illustrates further the scope for novel cryptographic applications of relativistic quantum theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Scoping Study to Determine the Location-Specific WEC Threshold Size for Wave-Powered AUV Recharging

The aim of this study is to determine the threshold wave energy converter (WEC) type and size to charge a fleet of U.S. Navy autonomous underwater vehicles (AUVs) in various geographic locations of interest. The U.S. Navy deploys AUVs in locations around the world that must be charged manually, decreasing their operational endurance and creating operational limitations. Ocean waves are a potential power source that can be converted into electricity using a WEC and stored using a battery. It would be beneficial to develop a WEC that could autonomously charge AUVs offshore. Numerous locations were analyzed to determine the minimum size of a WEC capable of providing sufficient charging power and offering a strategic advantage. By predicting the WEC efficiency (based on empirical equations) and wave resource (based on available data), electrical power generation across numerous WEC types and locations was compared in MATLAB. The generalized process developed here could be used to determine the required size and type of WECs to charge a fleet of AUVs in different locations around the world.

16 TIDAL AND WAVE POWER↗

Biomass yield in a genetically diverse Miscanthus sacchariflorus germplasm panel phenotyped at five locations in Asia, North America, and Europe

Abstract Miscanthus is a high‐yielding bioenergy crop that is broadly adapted to temperate and tropical environments. Commercial cultivation of Miscanthus is predominantly limited to a single sterile triploid clone of Miscanthus × giganteus , a hybrid between Miscanthus sacchariflorus and M. sinensis. To expand the genetic base of M. × giganteus , the substantial diversity within its progenitor species should be used for cultivar improvement and diversification. Here, we phenotyped a diversity panel of 605 M. sacchariflorus from six previously described genetic groups and 27 M. × giganteus genotypes for dry biomass yield and 16 yield‐component traits, in field trials grown over 3 years at one subtropical location (Zhuji, China) and four temperate locations (Foulum, Denmark; Sapporo, Japan; Urbana, Illinois; and Chuncheon, South Korea). There was considerable diversity in yield and yield‐component traits among and within genetic groups of M. sacchariflorus , and across the five locations. Biomass yield of M. sacchariflorus ranged from 0.003 to 34.0 Mg ha −1 in year 3. Variation among the genetic groups was typically greater than within, so selection of genetic group should be an important first step for breeding with M. sacchariflorus . The Yangtze 2x genetic group (=ssp. lutarioriparius ) of M. sacchariflorus had the tallest and thickest culms at all locations tested. Notably, the Yangtze 2x genetic group's exceptional culm length and yield potential were driven primarily by a large number of nodes (>29 nodes culm −1 average over all locations), which was consistent with the especially late flowering of this group. The S Japan 4x, the N China/Korea/Russia 4x, and the N China 2x genetic groups were also promising genetic resources for biomass yield, culm length, and culm thickness, especially for temperate environments. Culm length was the best indicator of yield potential in M. sacchariflorus . These results will inform breeders' selection of M. sacchariflorus genotypes for population improvement and adaptation to target production environments.

59 BASIC BIOLOGICAL SCIENCES↗

Inter fractional variability of breathing phase definition as determined by fiducial location

Reconstruction of four-dimensional (4D) imaging typically requires an externally measurable surrogate to represent the real-time relative phase of respiration. A common method is to use a reflective marker on the external surface of the patient which moves with respiration and can be tracked in real time. The location of the marker is often chosen to maximize the observable motion, though this location may not be at the region of interest. We evaluate the importance of infrared (IR) marker placement location on breathing phase definition for the purpose of respiratory gating and 4D computed tomography (CT) image reconstruction. Data were collected for ten patients enrolled on an approved IRB protocol. Real-time position data were collected during CT imaging and daily treatments for two external IR reflective markers: one placed near the xyphoid and another at the approximate location of the treatment isocenter. Motion traces from the markers were compared using cross-correlation coefficient and by estimating the relative respiratory phase, based on either marker, as would be used for 4D-CT reconstruction. Cross-correlation analysis revealed differences in the motion waveform, as well as phase differences, both of which were variable between patients as well as day to day for the same patient. Estimated relative phases from each marker were compared by the percentage amount of time the estimated phase for each marker was different, binned based on increments of 10% of a full cycle. For all collected data combined, the frequency with which breathing phase mismatch led to different bin allocation in steps of 10% was as follows: T{sub 010%}=65.1%, T{sub 1020%}=25.3%, T{sub 2030%}=7.8%, T{sub 3040%}=1.5% and T{sub 4050%}=0.4%. Based on ten images per cycle, this indicates that 4D reconstructions would be influenced, depending on which marker was used, by at least 1 bin 34.9% of the time. This number was noticeably higher for some patients; the maximum was 71% of the time for one patient of ten. In conclusion, the respiratory amplitude and relative phase depend significantly on the location of the IR marker used to monitor respiration. For some patients the xyphoid and isocentric markers may be completely out of phase. More importantly, this relationship varies day to day, suggesting that a single marker may be inadequate for the purposes of respiratory gating.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-F-CAMPUS-I-01: Investigation of the Effective Dose From Bolus Tracking Acquisitions at Different Anatomical Locations in the Chest for CT

Purpose: Stationary table acquisitions (Bolus tracking) in X-ray Computed Tomography (CT) can Result in dose length products (DLP) comparable to spiral scans. It is today unclear whether or not the effective dose (E) for Bolus Tracking can be approximated using target region specific conversion factors (E/DLP). The purpose of this study was to investigate how E depends on the anatomical location of the Bolus Tracking in relation to Chest CT scans with the same DLP. Methods: Effective doses were approximated for the ICRP 110 adult Reference Male (AM) and adult Reference Female (FM) computational voxel phantoms using software for CT dose approximations (pre-simulated MC data). The effective dose was first approximated for a Chest CT scan using spiral technique and a CTDIvol (32 cm) of 6 mGy. The effective dose from the spiral scan was then compared to E approximated for contiguous Bolus Tracking acquisitions (1 cm separation), with a total collimation of 1 cm, over different locations of the chest of the voxel phantoms. The number of rotations used for the Bolus Tracking acquisitions was adjusted to yield the same DLP (32 cm) as the spiral scan. Results: Depending on the anatomical location of the Bolus Tracking, E ranged by factors of 1.3 to 6.8 for the AM phantom and 1.4 to 3.3 for the AF phantom, compared to the effective dose of the spiral scans. The greatest E for the Bolus Tracking acquisitions was observed for anatomical locations coinciding with breast tissue. This can be expected as breast tissue has a high tissue weighting factor in the calculation of E. Conclusion: For Chest CT scans, the effective dose from Bolus Tracking is highly dependent on the anatomical location where the scan is administered and will not always accurately be represented using target region specific conversion factors.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-09: Tumor Location Prediction Using Natural Respiratory Volume for Respiratory Gated Radiation Therapy (RGRT): System Verification Study

Purpose: Respiratory gated radiation therapy (RGRT) gives accurate results when a patient’s breathing is stable and regular. Thus, the patient should be fully aware during respiratory pattern training before undergoing the RGRT treatment. In order to bypass the process of respiratory pattern training, we propose a target location prediction system for RGRT that uses only natural respiratory volume, and confirm its application. Methods: In order to verify the proposed target location prediction system, an in-house phantom set was used. This set involves a chest phantom including target, external markers, and motion generator. Natural respiratory volume signals were generated using the random function in MATLAB code. In the chest phantom, the target takes a linear motion based on the respiratory signal. After a four-dimensional computed tomography (4DCT) scan of the in-house phantom, the motion trajectory was derived as a linear equation. The accuracy of the linear equation was compared with that of the motion algorithm used by the operating motion generator. In addition, we attempted target location prediction using random respiratory volume values. Results: The correspondence rate of the linear equation derived from the 4DCT images with the motion algorithm of the motion generator was 99.41%. In addition, the average error rate of target location prediction was 1.23% for 26 cases. Conclusion: We confirmed the applicability of our proposed target location prediction system for RGRT using natural respiratory volume. If additional clinical studies can be conducted, a more accurate prediction system can be realized without requiring respiratory pattern training.

60 APPLIED LIFE SCIENCES↗

Alternative Fueling Station Locator - ANDROID [SWR 17-07]

The Alternative Fueling Station Locator app helps you find fueling stations that offer electricity, natural gas, biodiesel, ethanol (E85), propane, and hydrogen. Use your current location or enter a custom location to find the 20 closest stations within a 30-mile radius. View the stations on a map or see a list of stations ordered by distance from your location. Select your alternative fuel of choice and adjust the custom filters to fit your needs. Select a station from the map or list to view contact info and other details: - address, phone number, and hours of operation - payment types accepted - public or private access - special services - compression (natural gas) - vehicle size access (natural gas) - number and types of chargers (electric) - blends available (biodiesel) - blender pumps (ethanol) The free app draws information from the U.S. Department of Energy's Alternative Fuels Data Center, which houses the most comprehensive, up-to-date database of alternative fueling stations in the United States. The database contains location information for more than 25,000 alternative fueling stations throughout the country.

Rahill, Matt↗

Alternative Fueling Station Locator - APPLE [SWR 17-06]

The free Alternative Fueling Station Locator app helps you find fueling stations that offer electricity, natural gas, biodiesel, E85, propane, or hydrogen. Use your current location or enter a custom location to find the 20 closest stations within a 30-mile radius. View the stations on a map or see a list of stations ordered by distance from your location. Select your alternative fuel of choice and adjust the custom filters to fit your needs. Select a station from the map or list to view contact info and other details: - address, phone number, and hours of operation - payment types accepted - public or private access - special services - compression (natural gas) - vehicle size access (natural gas) - number and types of chargers (electric) - blends available (biodiesel) - blender pumps (ethanol) The app draws information from the U.S. Department of Energy's Alternative Fuels Data Center, which houses the most comprehensive, up-to-date database of alternative fueling stations in the United States. The database contains location information for more than 15,000 alternative fueling stations throughout the country.

Muerdter, Nick↗

Effective sensor location for detection of change in structural dynamic response

This paper investigates the sensitivity of structural system response to the sensor location by investigating consequences of small changes in the location to the structural system response. The paper discusses how maximum observability (based on mode shape and the participation of that mode in the input provided) drives optimal location. The structural responses were investigated in terms of the g-rms response for various low-frequency inputs (pure sinusoids and real-life inputs such as an earthquake and trains). Results were then analyzed in the context of Modal Contributions Factors (MCF) and changes to the Force-to-response Transfer Functions (TRFs). A modal-matching process is first presented using a Matlab TM -based Finite Element Method (FEM) model of a cantilever beam and instrumentation to determine the location of a small mass based on three different criteria. Subsequently, the structural response is investigated using experiments and the FEM model. The accelerometer of small mass (at 1/3 height) was moved up or down to obtain changes in the structural response (TRF) to various realistic low-frequency inputs. Modal Contribution Factor (MCF) and derivative (slope) of the associated mode-shapes were correlated to the observed changes in TRFs. Results show how optimal sensor locations for detecting change in structural response can be based on the MCFs and the associated mode-shapes.

Woodall, J.↗

Improved Regional and TeleseismicP-Wave Travel-Time Prediction and Event Location Using a Global 3D Velocity Model

A global validation dataset of 116 seismic events and 20,977 associated Pn and P arrivals is used to assess travel-time prediction and event location accuracy for the global-scale, 3D, P-wave velocity model called LLNL-G3Dv3 (Simmons et al., 2012). Strong regional trends that are observed for ak135 travel-time residuals are largely removed when LLNL-G3Dv3 is used for prediction. The 25th–75th quantile spread of travel-time residuals is reduced by 30%–40% at teleseismic distances, and the spread is reduced by ~60% at regional distances (<16°). Epicenter error decreases when more data are used to constrain event locations until more than ~40 arrivals times are used. At which point, epicenter error reduction tends to plateau. Median epicenter errors for the ak135 and LLNL-G3Dv3 models plateau at ~8:0 and ~5:5 km, respectively, for teleseismic P datasets. Median epicenter errors for the ak135 and LLNL-G3Dv3 models plateau at ~12:0 and ~4:0 km, respectively, for regional Pn datasets. We demonstrate that spatially correlated travel-time residual errors for the ak135 model lead to increasing epicenter error when ~40 to ~100 Pn arrivals are used to constrain the location. The effect of correlated error is mitigated by LLNL-G3Dv3, for which epicenter error steadily decreases to ~4 km when 100 Pn arrivals are used. The median area of 0.95 epicenter probability bounds for ak135 and LLNL-G3Dv3 are 1811 and 758 km 2 , respectively. The ak135 ellipses are inflated to achieve the desired rate of true events occurring inside the probability region, whereas LLNLG3Dv3 error ellipses based on empirical residual distributions cover the true location at the expected rate because location bias is minimal.

58 GEOSCIENCES↗

Locating Operational Events of the Cooling Tower of a Nuclear Reactor with a Very Local Seismic Network

Geolocation of emergent seismic signals is challenging at close distances. Here, we used three-component data from a seismic network and a targeted experiment at a research nuclear reactor to locate seismic sources. Utilizing known events collected during the targeted experiment, we were able to infer source locations with seismic amplitudes and polarization characteristics of the data. Although the resolution of the source location is not perfect, the seismic amplitudes and polarization analysis offer useful constraints. For the known events, the source region inferred with our analysis includes the true source locations. Synthetic tests indicate the resolution is largely due to limited data coverage and measurement uncertainties because the synthetic tests show similar results compared with the field data. We identified the source of the unknown event through spectrum cross correlation between the signals from the known events and an unknown event. Our findings were confirmed by operational staff at the facility. When the propagation medium properties (i.e., seismic velocity and quality factor for attenuation) are known, our analysis can be applied to continuous data from a seismic array to infer both source amplitude and location. If the medium properties are not known, a targeted experiment can be conducted to estimate them.

58 GEOSCIENCES↗

Assessment of the Group 5-6 (LB C2, LB S2, LV S1) Stack Sampling Probe Locations for Compliance with ANSI/HPS N13.1 1999

This document reports on a series of tests to assess the proposed air sampling locations for the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Group 5-6 exhaust stacks with respect to the applicable criteria regarding the placement of an air sampling probe. The LB-C2, LV-S1, and LB S2 exhaust stacks were tested together as a group (Test Group 5-6) because the common factor in their design is that the last significant flow disturbance upstream of the air sampling probe is a reduction in duct diameter. Federal regulations( ) require that a sampling probe be located in the exhaust stack according to the criteria of the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999, Sampling and Monitoring Releases of Airborne Radioactive Substances from the Stack and Ducts of Nuclear Facilities. These criteria address the capability of the sampling probe to extract a sample that represents the effluent stream. The testing on scale models of the stacks conducted for this project was part of the River Protection Project—Waste Treatment Plant Support Program under Contract No. DE-AC05-76RL01830 according to the statement of work issued by Bechtel National Inc. (BNI, 24590-QL-SRA-W000-00101, N13.1-1999 Stack Monitor Scale Model Testing and Qualification, Revision 1, 9/12/2007) and Work Authorization 09 of Memorandum of Agreement 24590-QL-HC9-WA49-00001. The internal Pacific Northwest National Laboratory (PNNL) project for this task is 53024, Work for Hanford Contractors Stack Monitoring. The testing described in this document was further guided by the Test Plan Scale Model Testing the Waste Treatment Plant LB-C2, LB-S2, and LV-S1 (Test Group 5-6) Stack Air Sampling Positions (TP-RPP-WTP-594). The tests conducted by PNNL during 2009 and 2010 on the Group 5-6 scale model systems are described in this report. The series of tests consists of various measurements taken over a grid of points in the duct cross-section at the designed sampling probe locations and at five duct diameters up and downstream from the design location to accommodate potential construction variability. The tests were done only at the design sampling probe location on the scale model of LB-S2 because that ductwork was already constructed. The ANSI/HPS N13.1-1999 criteria and the corresponding results of the test series on the scale models are summarized in this report.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Preliminary Analysis of Dose Rates Associated with ITER CVCS Equipment/Area Location

A preliminary analysis of the ITER Chemical and Volume Control System (CVCS) Area was performed to assess dose rates outside the walls and ceiling of the facility after 1.5 years of operation at shutdown, 2 days, and 10 days after shutdown. For this purpose a simplified Monte Carlo computer model was developed using the MCNP (MCNP5 Ver. 1.51) code. Two components are included: the smaller filter tank and the larger ion exchanger. These pieces of equipment are associated with the Integrated Blanket ELM Divertor Primary Heat Transfer System, which will have the largest dose rates associated with activated corrosion products during operation in comparison with other systems. The ion exchanger contained two source regions, a 1.2-m-thick resin bed above a 0.55 m-thick skirt, and a 0.8-m-thick water region. The filter constituted an additional source. Thus the model consisted of three sources (filter, resin, water), homogeneously distributed within the appropriate source regions. However, much of the results (that address individual isotopes) are presented with the two sources in the ion exchanger combined. In these cases the sources are referred to as the 'ion exchanger source' and the 'filter source.' Dimensions for the facility and components, as well as source isotopes and strengths, and material densities, were supplied by US ITER. Because of its simplification, the model does not contain pipes. Consequently, radiation streaming through pipe penetrations, radiation emanating from the pipes, and shielding from the pipes were not considered in this analysis. Dose rates on the outside of two walls and the ceiling were calculated. The two walls are labeled as the 'long' wall (aligned with the X-axis) and the 'short' wall (aligned with the Y-axis). These walls and ceiling were nominally set to 30-cm-thick concrete. In the original analysis, standard concrete (2.3 g/cc density) was used. In addition to the shielding walls/ceiling, a floor and an additional wall opposite the long wall were added for photon scattering contributions. These were both 10-cm-thick, standard concrete structures. Other components (tanks, pipes, etc.), that were not included in the model, would potentially add additional scattering and shielding. Possibly these additional effects will be addressed in a later, more detailed analysis. The room was 29.6 m in length (X-axis), but was limited to 15 m in the model. The inside width (Y axis) and height (Z axis) were 4 m and 3.4 m, respectively. The origin for the model was located inside the room at the corner opposite the long wall and adjacent to the short wall at the floor level. The room was filled with air at standard temperature and pressure. The stainless steel (SS304) wall thicknesses for the ion exchanger and filter were 2.2 cm and 0.8 cm, respectively. The axial center of the filter was located 140 cm from the short wall and 100 cm from the long wall (outer surface). The axial center of the ion exchanger was located 440 cm from the short wall and 250 cm from the long wall (inner surface). The resin was assumed to be a homogeneous mixture of equal atom density fractions of hydrogen and carbon* at a specified density of 1.136 g/cc. The filter material was assumed to be homogeneous carbon at a specified density of 1.8 g/cc. If the filter media were stainless steel and the accumulated activity were the same, the dose rate outside the filter would be lower, provided the density of the stainless steel sintered filter material is significantly higher than 1.8g/cc. The densities of the water and air were assumed to be 1.0 g/cc and 1.096E-3 g/cc, respectively. The model included 10 small volumes placed outside the model adjacent to the wall at locations where the dose rates were expected to be highest and which showed to a degree the fall-off of the dose rate with distance along a particular wall or ceiling. These 'tally cells' are shown in Fig. 2 and are described in Table 1. Each cell had dimensions of 50 cm x 50 cm x 1 cm and was oriented so that the 1-cm-thick dimension was perpendicular to the wall against which the cell was located. Also, smaller tally volumes were placed at 5 cm (updated model), 30 cm, 50 cm, and 100 cm from each source, both radially from the outside of each component at the height of each source mid-plane, and vertically, along the axial centerline, above the ion-exchanger and below the filter. (For the ion exchanger, the vertical distance was limited to 75 cm because of interference from the ceiling.) These tally regions can be seen in Fig. 3. Each cell had dimensions of 5 cm x 5 cm x 1 cm, oriented so that the 1-cm-thick dimension was perpendicular to the X, Y or Z axis.

08 HYDROGEN↗

Finding beam loss locations in a linac with oscillating dipole correctors

The paper proposes a method of finding the beam loss locations in a linac. If the beam is scraped at an aperture limitation, moving its centroid with two dipole correctors located upstream and oscillating in sync produces a line at the corresponding frequency in spectra of current-sensitive devices downstream of the loss point. The phase of this signal contains information about the location of the beam loss. Similar lines appear also in the position signals of Beam Position Monitors (BPMs). The phases of the BPM position lines change monotonically (within each 2π) along the linac and can be used a reference system. The phase of the loss signal compared with this reference system pinpoints the beam loss location, assuming that longitudinal coordinates of the BPMs are known. If the correctors deflection amplitudes and the phase offset between their waveforms are chosen optimally and well calibrated, the same measurement provides values of the β-function and the betatron phase advance at the BPM locations. Optics measurements of this type can be made parasitically, with negligible effect on the emittance, if a long measurement time is acceptable.

43 PARTICLE ACCELERATORS↗

Facility Location Optimization Model for COVID-19 Resources

In response to anticipated resource shortfalls related to the treatment and testing of COVID-19, many communities are planning to build additional facilities to increase capacity. These facilities include field hospitals, testing centers, mobile manufacturing units, and distribution centers. In many cases, these facilities are intended to be temporary and are designed to meet an immediate need. When deciding where to place new facilities many factors need to be considered, including the feasibility of potential locations, existing resource availability, anticipated demand, and accessibility between patients and the new facility. In this project, a facility location optimization model was developed to integrate these key pieces of information to help decision makers identify the best place, or places, to build a facility to meet anticipated resource demands. The facility location optimization model uses the location of existing resources and the anticipated resource demand at each location to minimize the distance a patient must travel to get to the resource they need. The optimization formulation is presented below. The model was designed to operate at the county scale, where patients are grouped per county. This assumption can be modified to integrate other scales or include individual patients.

60 APPLIED LIFE SCIENCES↗

Hanford Waste Treatment Plant Low Activity Waste Facility Stack Effluent Monitoring - Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant low activity waste (LAW) facility stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAW stacks were performed at normal operating conditions. The minimum 1/6 DV value, along with the maximum 6 DV value from the scale model testing determines the range of conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. Based on these DV values, the corresponding stack flow rates for each of the LAW stacks are 815–55,758 scfm for LV-S1, 980–112,078 scfm for LV-S2, 264–22,901 scfm for LV-S3, and 981–79,832 scfm for LV-C2. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be =20°. Second, the velocity uniformity at the full-scale stack must be =20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack tests at the LAW facility. Flow angle results were primarily less than 10°, except for one LV-S2 Fan A result, which was 13.2°; all flow angle results were within the =20° criterion. The velocity uniformity results for each test condition ranged between 1.5 COV and 9.2% COV, which were all within the range of the target % COV values from the scale model tests. Based on these stack verification test results, the four LAW filtered exhaust stack sampling locations meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all fan operating configurations. This includes single-fan operating conditions for LV-S1 and LV-S2, dual-fan operations for LV-S3 at both the continuous air monitor and record sampler locations, and both the single-fan as well as the dual-fan operations for LV-C2. Further changes to the system configuration or operating conditions that are outside the bounds described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hybrid AI-ML and FE-based Digital Twin Predictive Modeling Framework for a PWR Coolant System Components: Updates on Multi-Time-Series-3D-Location Dependent Usages Factor Prediction

The long-term operation (LTO) of nuclear power plants (NPP) beyond their original design life of 40 years can lead to more material damage associated with cyclic fatigue under thermal-mechanical loading cycles and associated long-term exposure of reactor material to the deleterious reactor-coolant environments. However, under this LTO condition, the reactor components can still safely operate but may require more frequent Nondestructive Evaluation (NDE) of reactor components. Requiring frequent NDE inspections may lead to frequent NPP shutdowns which can lead to power outages and additional NDE inspection cost-related economic loss. The economic loss can be minimized by reducing uncertainty in life estimation of safety-critical pressure boundary components and by implementing a more digital approach such as using upcoming digital-twin (DT) technology for predicting the structural states (e.g., time and location dependent inside/outside thickness temperature, stress, strain, plastic deformation, etc.) and associated fatigue life of a component in real time. The DT framework is based on limited experimental data, Artificial-intelligence (AI)-Machine-Learning (ML) and multiphysics-computationalmechanics such as finite element- (FE) based models. Given the real-time thermal-hydraulic process measurements from several existing plant sensors, the overall goal of the DT framework is to predict the cumulative usages factors or equivalent fatigue lives in real time and at any random 3D location of the components. This includes inaccessible locations such as inside the thickness or location of a component. This prediction can be at thousands to millions of 3D point clouds or locations like conventional FE-based models, but without running an FE model in real time.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗