At least 145 records · Page 8

A compact filtered x-ray diode array spectrometer for the National Ignition Facility: SENTINEL

Sentinel is a 16-channel, filtered x-ray diode array spectrometer that has been developed to measure ~1 keV–20 keV x-ray emission generated by the National Ignition Facility (NIF) laser. Unlike the large, fixed-port versions of this diagnostic that currently exist on the NIF (known as Dante), Sentinel is a Diagnostic Instrument Manipulator compatible such that it can be fielded along the polar or equatorial lines-of-sight—an essential new capability for characterizing the often anisotropic x-ray emission from laser-driven sources. Here, we present the diagnostic design along with preliminary diode calibrations and performance results. The novel, small-form-factor x-ray diode design allows for ≳5×–25× increased channel areal density over that of Dante, simultaneously enabling improved diagnostic robustness and fidelity of spectral reconstructions. While the Sentinel diagnostic is anticipated to improve line-of-sight spectral characterization of x-ray sources for a wide variety of programs on the NIF, the compact and portable design is also attractive to small- and mid-scale facilities with limited diagnostic real estate.

47 OTHER INSTRUMENTATION↗

Systems and methods for dual comb spectroscopy

A frequency-measurement method uses a dual frequency-comb spectrometer as an optical wavemeter to measure the frequency of a reference laser that is used to frequency-stabilize the spectrometer. The method includes measuring a walking rate of center bursts in a sequence of interferograms recorded by the spectrometer, determining a number of teeth in each of a plurality of Nyquist windows formed by the dual frequency-comb spectrometer, and determining a Nyquist number of the one Nyquist window covering the laser frequency. The reference laser frequency can then be determined from the number of teeth in each Nyquist window, the Nyquist number, and the comb spacing of either one of the two frequency combs of the dual frequency-comb spectrometer. The reference laser frequency does not need to be measured with a separate wavemeter, or calibrated with respect to a known atomic or molecular transition.

Rieker, Gregory B.↗

Chirped laser dispersion spectroscopy for spectroscopic chemical sensing with simultaneous range detection

Spectroscopic chemical detection requires knowledge or determination of an optical path for accurate quantification of path-integrated concentration of species. Continuous- wave-laser-based spectroscopic systems operating in an open integrated-path remote sensing configuration are usually not equipped for optical path determination. Here we demonstrate a measurement technique capable of simultaneous spectroscopic chemical quantification and range finding. Here, the range-finding functionality is implemented with chirped laser dispersion spectroscopy. The methodology is potentially useful for remote chemical sensing in a hard-target LIDAR configuration and for automatic calibration of gas cells with unknown or varying lengths.

03 NATURAL GAS↗

Calibration of the sub-aperture backscatter system on OMEGA EP

The sub-aperture backscatter (SABS) diagnostic on the OMEGA EP Laser System is a diagnostic that is used to measure the backscattered and sidescattered light during laser–plasma interaction experiments that are relevant to high-energy-density physics and inertial confinement fusion. The diagnostic collects stimulated Brillouin scattering (SBS) UV light at around 351 nm and stimulated Raman scattering (SRS) in the visible-light regime in the 420–720-nm-wavelength range and provides spectrally and temporally resolved information. Five 1-in. light collectors, composed of a lens, ground glass diffuser, and coupling into a 300-μm fiber, are positioned behind the last steering mirror on one of the four beamlines to catch a portion of the beam cross section (~1.5%) of the emission that is scattered into the beamline. The SRS light is collected in two light collectors, combined, and transported via graded index fibers to a streaked spectrometer. The SABS-SRS streak spectrometer has a temporal and spectral resolution of 100 ps and 1 nm, respectively. Three other light collectors collect, combine, and transport the SBS signal to a Hamamatsu high-voltage photodiode, where an oscilloscope digitizes the data, providing a time resolution of better than 1 ns. To obtain an absolute energy calibration of SRS measurements, light signals of known energy and wavelength were injected into the light collectors one at a time. The resulting counts on the streak camera charge-coupled device for SRS are then correlated with the incident fluence of scattered light at the light collector in order to allow a quantitative assessment of streak camera sensitivity to determine the energy of the scattered light during experiments. The measurements were performed in situ from the light collectors to the detectors. Other offline measurements provided the transmission of the optics between the target chamber center and the light collectors.

47 OTHER INSTRUMENTATION↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

A VIPA Spectrograph with Ultra-high Resolution and Wavelength Calibration for Astronomical Applications

A prototype spectrograph using a Virtually Imaged Phased Array (VIPA) as the main dispersion element is presented, and its performance is fully examined in our laboratory. The single-mode, fiber-fed spectrograph with simultaneous wavelength calibration possesses a spectral resolution well in excess of R≈1.12×10{sup 6} while the size of the VIPA is several orders of magnitude smaller than that of a conventional échelle with comparable resolution. In laboratory tests, the VIPA-based instrument with a homemade Yb:fiber ring laser frequency comb demonstrates a mode-to-mode tracking stability of 41 cm s{sup −1} over a period of 6 hr. The VIPA spectrograph has promising applications in various astronomical observations in which ultra-high resolution and calibration precision are imperative, such as solar physics research, exoplanet searching with the radial velocity method, and O{sub 2} detection in the atmosphere of Earth-like planets. Ultimately, feasible optimizations for night-sky observations under seeing limited conditions are discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

A novel photomultiplier tube neutron time-of-flight detector

A traditional neutron time-of-flight (nTOF) detector used in inertial confinement fusion consists of a scintillator coupled with a photomultiplier tube (PMT). The instrument response function (IRF) of such a detector is dominated by the scintillator-light decay. At DT neutron yields larger than 1013 a novel detector consisting of a microchannel-plate photomultiplier tube in a housing without a scintillator (PMT nTOF) can be used to measure DT yield, ion temperature, and neutron velocity. Most of the neutron signal in PMT nTOF is produced from neutron interaction with a PMT window. The direct interaction of neutrons with MCP has negligible contribution. The elimination of the scintillator removes the scintillator decay from the instrument response function and makes the IRF of the PMT nTOF faster, which makes the ion temperature and neutron velocity measurements more accurate. Three PMT nTOFs were deployed on the OMEGA Laser System for the first time to diagnose inertial confinement fusion plasma. Here, the design details, characteristics, and calibration results of these detectors in DT implosions on OMEGA are presented. Recommendations on the use of different PMTs for specific applications are provided.

47 OTHER INSTRUMENTATION↗

X-ray absorption spectroscopy measurements of radiatively ionized argon gas

X-ray absorption spectroscopy is a diagnostic tool that can characterize the temperature and ionization state of a plasma. This technique requires experiments to characterize the platform, careful data calibration, and comparison with atomic models to understand the plasma parameters. We performed ionizing radiation wave experiments at the OMEGA Laser Facility that used an ∼ 80 eV X-ray source to heat an Argon (Ar) gas cell at fill pressures of 3 atm. To diagnose the Ar plasma, we used a capsule backlighter offset 10 mm from the gas cell, to produce X-rays that were absorbed by the ionized Ar gas. The absorption analysis was calibrated using the significant line structure in the backlighter spectrum, which served as independent energy fiducials enabling definitive measurements of a 50-eV shift in the energy of the Ar K-edge due to ionization. We compare the measured absorption spectra to two independent atomic models, PrismSPECT and SCRAM, and show that the observed K-edge shift in the heated gas is consistent with ionization up to Ar 4+ and temperatures of 10 eV.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative x-ray scattering of free molecules

Advances in x-ray free electron lasers have made ultrafast scattering a powerful method for investigating molecular reaction kinetics and dynamics. Accurate measurement of the ground-state, static scattering signals of the reacting molecules is pivotal for these pump-probe x-ray scattering experiments as they are the cornerstone for interpreting the observed structural dynamics. Here, this article presents a data calibration procedure, designed for gas-phase x-ray scattering experiments conducted at the Linac Coherent Light Source x-ray Free-Electron Laser at SLAC National Accelerator Laboratory, that makes it possible to derive a quantitative dependence of the scattering signal on the scattering vector. A self-calibration algorithm that optimizes the detector position without reference to a computed pattern is introduced. Angle-of-scattering corrections that account for several small experimental non-idealities are reported. Their implementation leads to near quantitative agreement with theoretical scattering patterns calculated with ab-initio methods as illustrated for two x-ray photon energies and several molecular test systems.

74 ATOMIC AND MOLECULAR PHYSICS↗

SuperCam Calibration Targets: Design and Development

Abstract SuperCam is a highly integrated remote-sensing instrumental suite for NASA’s Mars 2020 mission. It consists of a co-aligned combination of Laser-Induced Breakdown Spectroscopy (LIBS), Time-Resolved Raman and Luminescence (TRR/L), Visible and Infrared Spectroscopy (VISIR), together with sound recording (MIC) and high-magnification imaging techniques (RMI). They provide information on the mineralogy, geochemistry and mineral context around the Perseverance Rover. The calibration of this complex suite is a major challenge. Not only does each technique require its own standards or references, their combination also introduces new requirements to obtain optimal scientific output. Elemental composition, molecular vibrational features, fluorescence, morphology and texture provide a full picture of the sample with spectral information that needs to be co-aligned, correlated, and individually calibrated. The resulting hardware includes different kinds of targets, each one covering different needs of the instrument. Standards for imaging calibration, geological samples for mineral identification and chemometric calculations or spectral references to calibrate and evaluate the health of the instrument, are all included in the SuperCam Calibration Target (SCCT). The system also includes a specifically designed assembly in which the samples are mounted. This hardware allows the targets to survive the harsh environmental conditions of the launch, cruise, landing and operation on Mars during the whole mission. Here we summarize the design, development, integration, verification and functional testing of the SCCT. This work includes some key results obtained to verify the scientific outcome of the SuperCam system.

Manrique, J. A. (ORCID:0000000220532819)↗

2D-imaging of absolute OH and H 2 O 2 profiles in a He–H 2 O nanosecond pulsed dielectric barrier discharge by photo-fragmentation laser-induced fluorescence

We report pulsed dielectric barrier discharges (DBD) in He–H 2 O and He–H 2 O–O 2 mixtures are studied in near atmospheric conditions using temporally and spatially resolved quantitative 2D imaging of the hydroxyl radical (OH) and hydrogen peroxide (H 2 O 2 ). The primary goal was to detect and quantify the production of these strongly oxidative species in water-laden helium discharges in a DBD jet configuration, which is of interest for biomedical applications such as disinfection of surfaces and treatment of biological samples. Hydroxyl profiles are obtained by laser-induced fluorescence (LIF) measurements using 282 nm laser excitation. Hydrogen peroxide profiles are measured by photo-fragmentation LIF (PF-LIF), which involves photo-dissociating H 2 O 2 into OH with a 212.8 nm laser sheet and detecting the OH fragments by LIF. The H 2 O 2 profiles are calibrated by measuring PF-LIF profiles in a reference mixture of He seeded with a known amount of H 2 O 2 . OH profiles are calibrated by measuring OH-radical decay times and comparing these with predictions from a chemical kinetics model. Two different burst discharge modes with five and ten pulses per burst are studied, both with a burst repetition rate of 50 Hz. In both cases, dynamics of OH and H 2 O 2 distributions in the afterglow of the discharge are investigated. Gas temperatures determined from the OH-LIF spectra indicate that gas heating due to the plasma is insignificant. The addition of 5% O 2 in the He admixture decreases the OH densities and increases the H 2 O 2 densities. The increased coupled energy in the ten-pulse discharge increases OH and H 2 O 2 mole fractions, except for the H 2 O 2 in the He–H 2 O–O 2 mixture which is relatively insensitive to the additional pulses.

hydrogen peroxide↗

Analysis of heat transfer and AuNPs-mediated photo-thermal inactivation of E. coli at varying laser powers using single-phase CFD modeling

In the wake of the COVID-19 pandemics, the demand for innovative and effective methods of bacterial inactivation has become a critical area of research, providing the impetus for this study. The purpose of this research is to analyze the AuNPs-mediated photothermal inactivation of E. coli. Gold nanoparticles irradiated by laser represent a promising technique for combating bacterial infection that combines high-tech and scientific progress. The intermediate aim of the work was to present the calibration of the model with respect to the gold nanorods experiment. The purpose of this work is to study the effect of initial concentration of E. coli bacteria, the design of the chamber and the laser power on heat transfer and inactivation of E. coli bacteria. Using the CFD simulation, the work combines three main concepts. 1. The conversion of laser light to heat has been described by a combination of three distinctive approximations: a- Discrete particle integration to take into account every nanoparticle within the system, b- Rayleigh-Drude approximation to determine the scattering and extinction coefficients and c- Lambert–Beer–Bourger law to describe the decrease in laser intensity across the AuNPs. 2. The contribution of the presence of E. coli bacteria to the thermal and fluid-dynamic fields in the microdevice was modeled by single-phase approach by determining the effective thermophysical properties of the water-bacteria mixture. 3. An approach based on a temperature threshold attained at which bacteria will be inactivated, has been used to predict bacterial response to temperature increases. The comparison of the thermal fields and temporal temperature changes obtained by the CFD simulation with those obtained experimentally confirms the accuracy of the light-heat conversion model derived from the aforementioned approximations. The results show a linear relationship between maximum temperature and variation in laser power over the range studied, which is in line with previous experimental results. It was also found that the temperature inside the microchamber can exceed 55 °C only when a laser power higher than 0.8 W is used, so bacterial inactivation begins. The experimental data allows to determinate the concentration of nanoparticles. This parameter is introduced into the mathematical model obtaining the same number of AuNPs. However, this assumption introduces a certain simplification, as in the mathematical model the distribution of nanoparticles is uniform. This work is directly connected to the use of gold nanoparticles for energy conversion, as well as the field of bacterial inactivation in microfluidic systems such as lab-on-a-chip. Presented mathematical and numerical models can be extended to the entire spectrum of wavelengths with particular use of white light in the inactivation of bacteria. This work represents a significant advancement in the field, as to the best of the authors’ knowledge, it is the first to employ a single-phase computational fluid dynamics (CFD) approach specifically combined with the thermal inactivation of bacteria. Moreover, this research pioneers the use of a numerical simulation to analyze the temperature threshold of photothermal inactivation of E. coli mediated by gold nanorods (AuNRs). The integration of these methodologies offers a new perspective on optimizing bacterial inactivation techniques, making this study a valuable contribution to both computational modeling and biomedical applications.

36 MATERIALS SCIENCE↗

The SuperCam Instrument Suite on the NASA Mars 2020 Rover: Body Unit and Combined System Tests

The SuperCam instrument suite provides the Mars 2020 rover, Perseverance, with a number of versatile remote-sensing techniques that can be used at long distance as well as within the robotic-arm workspace. These include laser-induced breakdown spectroscopy (LIBS), remote time-resolved Raman and luminescence spectroscopies, and visible and infrared (VISIR; separately referred to as VIS and IR) reflectance spectroscopy. A remote micro-imager (RMI) provides high-resolution color context imaging, and a microphone can be used as a stand-alone tool for environmental studies or to determine physical properties of rocks and soils from shock waves of laser-produced plasmas. SuperCam is built in three parts: The mast unit (MU), consisting of the laser, telescope, RMI, IR spectrometer, and associated electronics, is described in a companion paper. The on-board calibration targets are described in another companion paper. Here we describe SuperCam’s body unit (BU) and testing of the integrated instrument. The BU, mounted inside the rover body, receives light from the MU via a 5.8 m optical fiber. The light is split into three wavelength bands by a demultiplexer, and is routed via fiber bundles to three optical spectrometers, two of which (UV and violet; 245–340 and 385–465 nm) are crossed Czerny-Turner reflection spectrometers, nearly identical to their counterparts on ChemCam. The third is a high-efficiency transmission spectrometer containing an optical intensifier capable of gating exposures to 100 ns or longer, with variable delay times relative to the laser pulse. This spectrometer covers 535–853 nm ( $105\text{--}7070~\text{cm}^{-1}$ Raman shift relative to the 532 nm green laser beam) with $12~\text{cm}^{-1}$ full-width at half-maximum peak resolution in the Raman fingerprint region. The BU electronics boards interface with the rover and control the instrument, returning data to the rover. Thermal systems maintain a warm temperature during cruise to Mars to avoid contamination on the optics, and cool the detectors during operations on Mars.Results obtained with the integrated instrument demonstrate its capabilities for LIBS, for which a library of 332 standards was developed. Examples of Raman and VISIR spectroscopy are shown, demonstrating clear mineral identification with both techniques. Luminescence spectra demonstrate the utility of having both spectral and temporal dimensions. Finally, RMI and microphone tests on the rover demonstrate the capabilities of these subsystems as well.

47 OTHER INSTRUMENTATION↗

Spatiotemporal Automatic Calibration of Infrastructure Lidar, Radar, and Camera with a Global Navigation Satellite System

Robust and accurate perception is important for modern intelligent transportation systems (ITS), which use sensors of various modalities for data fusion to create a digital twin of an intersection. Sensor calibration is an important process that creates a unified coordinate frame for the sensor output data so that it can be used for data fusion. Classical approaches for sensor calibration are time-consuming, require an overlapping field of view for feature matching, and are not feasible for ITS application as they cause disruptions in the flow of traffic. In this paper, we present a spatiotemporal automatic calibration approach to calibrate multiple infrastructure lidar, radar, and cameras installed at a traffic intersection. The approach uses global navigation satellite system (GNSS) positioning information shared by connected vehicles, and when the vehicle is detected by the sensor, we match the sensor detections with the GNSS coordinates. The proposed algorithm is evaluated with a real-world dataset utilizing detections from two radars, cameras, and lidars with a test vehicle instrumented with a post-processing kinematic (PPK)-corrected GNSS driving past the sensors installed at a four-way traffic intersection. The experimental results show that the proposed automatic calibration approach can achieve the transformation with a root mean squared error of less than 0.5 for radar and lidar and less than 2 for camera detections. The ability to rapidly calibrate sensors not only benefits initial installations, but can also be used for system health monitoring, while utilizing available connected vehicle data to test the real-time sensor fidelity and operational status.

ADVANCED PROPULSION SYSTEMS,ENERGY CONSERVATION, C↗

Constraining hydrodynamic models of inertial confinement fusion implosions using capsule surrogate experiments

We conduct capsule surrogate experiments at the National Ignition Facility to calibrate radiation hydrodynamic simulations to infer hydrodynamic conditions that are not observable in indirect drive ignition implosions. We tune the simulations by applying laser power and cross beam energy transfer (CBET) saturation multipliers to match the observables from capsule surrogate experiments. Shock timing, velocity, and symmetry are measured in liquid D 2 filled Keyhole capsule surrogate experiments and implosion trajectory, stagnation time, and shape time history are measured in in-flight 2D backlit x-ray radiography experiments (“2DConA”) of D 2 gas filled capsule implosions. Calibrated simulations suggest that the N210808 ignition implosion (fusion target gain = 0.7) had a shell mass remaining at stagnation of less than the nominal %5 (3.8%) and resulted in less confinement. For N221204, the shell was made 5.75 μm thicker to trade implosion velocity for increased confinement and resulted in a target gain = 1.5 with a shell mass remaining of 5.7%. Furthermore, a single adjusted model can reproduce all shock timing data as changes are made to shell thickness (79–85 μm) and laser wavelength separation (1.8–4.0 Å). However, for the 2DConA implosions, a 5% variation in the peak power laser multipliers and a 30% variation in late-time CBET between experiments are needed to match the observed stagnation times, in-flight $P_2$ shape, and hot-spot $P_2$ shape. While progress is being made to improve the models in simulations using focused experiments, capsule surrogate experiments will continue to be needed to optimize future ignition designs.

Lasers↗

Depth-Resolved Lithiated Gradients in Pristine and Laser-Ablated Anodes During Fast Charging

Laser ablating 3D electrode microstructures is a technique to improve Li-ion battery fast-charge performance. This technique has been theoretically proposed and electrochemically validated previously in the literature. The fundamental principle underlying laser ablation is that the ablated features reduce Li-ion transport pathways, improving access to the electrode active material near the current collector. This, in turn, promotes more homogeneous electrode utilization. The present study seeks to directly affirm the physics attributed to laser ablation using operando high-speed synchrotron X-ray diffraction. In this study, depth-resolved graphite lithiation gradients are measured operando during high-rate (15 min) charging. The depth-resolved lithiation dynamics of both ablated and non-ablated anodes are compared. The results highlight that the laser-ablated graphite electrode has notably more homogeneous utilization as compared to the non-ablated electrode. Additionally, the ablated electrode has a significant delay in reaching the maximum graphite lithiation at the separator, indicating less propensity for lithium plating. During low rate delithiation/discharge (2 hr), the two cells' lithiation gradients converge. Notably, a calibrated physics-based electrochemical model accurately reflects experimental findings, suggesting the potential to use pseudo-4D models not only to optimize laser ablation parameters in fast-charge capable electrodes but also to guide fast charging protocols that avoid lithium plating.

25 ENERGY STORAGE↗

Assessing laser powder bed fusion system geometric errors through artifact-based methods

Additive manufacturing (AM) machines have developed more rapidly than standardized frameworks needed for the qualification of their geometric capabilities. While some manufacturer-specific methods exist to test capabilities and perform some calibration tasks, standardization efforts have only recently been undertaken in the form of ISO/ASTM 52902. In this study, the recommended methodology prescribed by the standard was implemented by building geometric artifacts with a laser powder bed fusion (LPBF) system and performing dimensional inspection with a coordinate measurement machine (CMM), amongst other methods. Typical dimensional capabilities of the LPBF system are identified and commentary is made on applying metrology methods, detecting geometric error, and diagnosing base causes in the LPBF system. In doing so, favored metrology practices and measurement analysis methods auxiliary to the standard are proposed. Artifact measurements were used to characterize beam positioning error and beam offset error. Methods for decoupling the effects of error sources are proposed. Difficulties in the inspection of AM components are identified, and the effects of various CMM measurement strategies are evaluated. Insights on the application of the new standard are presented, along with commentary as to its fitness for the LPBF process.

Berez, J.↗

Establishing a process-structure-property-performance framework for SLS additive manufacturing through integrated multiscale modeling

This study presents a comprehensive suite of high-fidelity computational models that integrate multiscale and multiphysics simulations to capture the full Selective Laser Sintering (SLS) additive manufacturing process—from initial melting and solidification to mechanical response under external loads. Process simulations are linked with mechanical analysis through Representative Volume Elements (RVEs), establishing a process-structure–property-performance framework. The interaction between laser light and polyamide 12 (PA12) powder is modeled, accounting for laser characteristics and the optical, thermal, and geometrical properties of the powder. The heat source is incorporated into a heat transfer model, coupled with crystallization kinetics and densification models to predict material density and crystallinity. The porosity distribution from the densification model and crystallinity interpolated from experimental data are used to construct the RVEs. A multi-mechanism constitutive model is then calibrated using mechanical tests to predict the stress–strain response. Simulation results show good agreement with experimental data in terms of porosity, crystallinity, and mechanical performance when sufficient laser power (62 W or higher) is used. This research supports the inverse design of 3D-printed structures by introducing a high-fidelity framework that combines multiscale and multiphysics modeling with experimental calibration for predictive and performance-driven additive manufacturing.

SLS↗