Search NASA⌕ Search

SEARCH · Search NASA

Results for “Laser Micrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Micron-Accurate Laser Fresnel-Diffraction Ranging System

Two versions of an optoelectronic system undergoing development are depicted. The system is expected to be capable of measuring a distance between 2 and 10 m with an error of no more than 1 micrometer. The system would be designed to exploit Fresnel diffraction of a laser beam. In particular, it would be designed to take advantage of the fact that a Fresnel diffraction pattern is ultrasensitive to distance. The two versions would differ in the following respects: In version 1, the focus of the telescope would be in the Fresnel region, and the telescope would have a small depth of focus. As a consequence, the Fresnel pattern would be imaged directly onto the photodetector array; in version 2, a multielement lens module would displace the Fresnel region from the vicinity of the pinhole to the vicinity of the optical receiver. As the distance to be measured varied, the location of the receiver relative to the displaced Fresnel-diffraction region would vary, thereby causing the Fresnel diffraction pattern on the focal plane to vary. The multielement lens module would also correct for aberrations. The processing of the digitized Fresnel diffraction pattern in the computer might be accelerated by using only parts of the pattern or even only one small part - the central pixel. As the distance from the pinhole increased, the central pixel would rapidly cycle between maximum and minimum light intensity. This in itself would not be sufficient to uniquely determine the distance. However, by varying the size of the pinhole or the wavelength of the laser, one could obtain a second cycle of variation of intensity that, in conjunction with the first cycle, could enable a unique determination of distance. Alternatively, for a single wavelength and a single pinhole size, it should suffice to consider the data from only two different key pixels in the Fresnel pattern.

Lehner, David↗

Effects of irradiation damage on the hardness and elastic properties of quaternary and high entropy transition metal diborides

Multi-principal component transition metal (TM) diborides represent a class of high-entropy ceramics (HECs) that have received considerable interest in recent years owing to their promising properties for extreme environment applications that include thermal/ environmental barriers, hypersonic vehicles, turbine engines, and next-generation nuclear reactors. While the addition of chemical disorder through the random distribution of TM elements on the cation sublattice has offered opportunities to tailor elastic stiffness and hardness, the effects of irradiation-induced structural damage on the physical properties of these complex materials have remained largely unexplored. To this end, changes in the hardness and elastic moduli of a high-entropy TM diboride (Hf 0.2 Nb 0.2 Ta 0.2 Ti 0.2 Zr 0.2 )B 2 and three of its quaternary subsets following irradiation with 10 MeV gold (Au) ions to fluences of up to 6 × 10 15 Au cm -2 are investigated at the micrometer and sub-micrometer length-scales via the dispersion of laser-generated surface acoustic waves (SAW) and nanoindentation, respectively. The nanoindentation measurements show that the TM diborides exhibit an initial increase in hardness following irradiation with energetic Au ions, with a subsequent decrease in hardness following further irradiation. One quaternary composition, (Hf 1/3 Ta 1/3 Ti 1/3 )B 2 , exhibits a notable exception to the trend and continues to exhibit an increase in hardness with ion irradiation fluence. Although differences in the absolute values of the effective elastic moduli obtained from the measured SAW dispersion and nanoindentation are observed (and attributed to microstructural variations at the measurement length-scale), both techniques yield similar trends in the form of an initial reduction and subsequent saturation in the elastic modulus with increasing ion irradiation fluence. The quaternary TM diboride (Hf 1/3 Ta 1/3 Ti 1/3 )B 2 again exhibits a departure from this trend. The high-entropy TM diboride (Hf 0.2 Nb 0.2 Ta 0.2 Ti 0.2 Zr 0.2 )B 2 exhibits the greatest recovery in hardness and modulus when irradiated to high ion fluences following initial changes at low fluence, indicating superior resistance to radiation-induced damage over its quaternary counterparts. Opportunities for designing HECs with superior hardness and modulus for enhanced radiation resistance (compared to their single constituent counterparts) by tailoring chemical disorder and bond character in the lattice are discussed.

36 MATERIALS SCIENCE↗

Doppler lidar atmospheric wind measurements

A brief overview is provided of the coherent Doppler lidar work at the Marshall Space Flight Center, taking into account the status and planned development of the system to be used for severe storms research. The considered system is a CW Doppler lidar operating at a wavelength of 10.6 micrometers. This lidar uses a 20 watt carbon dioxide laser. It has a range which is continuously variable from 60 m to approximately 600 m. Range variation is achieved through changing the focus of a 30 cm f/2 Cassegrainian telescope. Successful measurements with the CW lidar have included two and three dimensional wind profiles, wing tip vortex tracks and profiles, dust devil tracks and profiles, and transverse as well as line-of-sight wind velocities. The pulsed lidar in recent ground tests has succeeded in measuring clear air returns to a range of 13 km and has provided substantial information on velocities associated with the gust fronts of thunderstorms.

Bilbro, J. W.↗

Monitoring The Atmosphere By Diode-Laser Spectroscopy

Report describes state of art of tunable-diode-laser second-harmonic spectroscopy applied to measurements of concentrations of trace constituents of atmosphere. Combination of temperature, composition, and drive-current tuning, wavelengths of tunable diode lasers varied over infrared range of 3 to 30 micrometer, containing spectral lines of many molecules of interest in atmospheric research.

Loewenstein, Max↗

Chromium Diffusion Doping on ZnSe Crystals

Chromium doped zinc selenide crystal have recently been demonstrated to be a promising material for near-IR room temperature tunable lasers which have an emission range of 2-3 micrometers. In this study a new diffusion doping process has been developed for incorporation of Cr(+2) ion into ZnSe wafers. This process has been successfully performed under isothermal conditions, at temperatures above 800 C. Concentrations in excess of 10(exp 19) Cr(+2) ions/cu cm, an order of magnitude larger than previously reported in melt grown ZnSe material, have been obtained by diffusion doping, as estimated from optical absorption measurements. The diffusivity was estimated to be about 10(exp -8) sq cm/sec using a thin film diffusion model. Resistivity was derived from current-voltage measurements and in the range of 10(exp 13) and 10(exp 16) omega-cm. The emission spectra and temperature dependent lifetime data will also be presented and discussed.

Journigan, Troy D.↗

Effects of irradiation damage on the elastic properties and hardness of complex transition metal diborides

Multi-principal component transition metal (TM) diborides represent a class of high-entropy ceramics (HECs) that have received considerable interest in recent years owing to their promising properties for extreme environment applications that include thermal/ environmental barriers, hypersonic vehicles, turbine engines, and next-generation nuclear reactors. While the addition of chemical disorder through the random distribution of TM elements on the cation sublattice has offered opportunities to tailor elastic stiffness and hardness, the effects of irradiationinduced structural damage on the physical properties of these complex materials have remained largely unexplored. To this end, changes in the hardness and elastic moduli of a high-entropy TM diboride (Hf0.2Nb0.2Ta0.2Ti0.2Zr0.2)B2 and three of its quaternary subsets following irradiation with 10 MeV gold (Au) ions to fluences of up to 6 × 10^15 Au cm-2 are investigated at the micrometer and sub-micrometer length-scales via the dispersion of laser-generated surface acoustic waves (SAW) and nanoindentation, respectively. The nanoindentation measurements show that the TM diborides exhibit an initial increase in hardness following irradiation with energetic Au ions, with a subsequent decrease in hardness following further irradiation. One quaternary composition, (Hf1/3Ta1/3Ti1/3)B2, exhibits a notable exception to the trend and continues to exhibit an increase in hardness with ion irradiation fluence. Although differences in the absolute values of the effective elastic moduli obtained from the measured SAW dispersion and nanoindentation are observed (and attributed to microstructural variations at the measurement length-scale), both techniques yield similar trends in the form of an initial reduction and subsequent saturation in the elastic modulus with increasing ion irradiation fluence. The quaternary TM diboride (Hf1/3Ta1/3Ti1/3)B2 again exhibits a departure from this trend. The high-entropy TM diboride (Hf0.2Nb0.2Ta0.2Ti0.2Zr0.2)B2 exhibits the greatest recovery in hardness and modulus when irradiated to high ion fluences following initial changes at low fluence, indicating superior resistance to radiation-induced damage over its quaternary counterparts. Opportunities for designing HECs with superior hardness and modulus for enhanced radiation resistance (compared to their single constituent counterparts) by tailoring chemical disorder and bond character in the lattice are discussed.

36 - MATERIALS SCIENCE↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Photomultiplier tube development for the 1.06 micrometer wavelength

High speed, electrostatic photomultipliers were developed for use in 400 megabit laser communication systems operating at the 1.06 micron wavelength. A high performance, electrostatic III-V photocathode PMT was shown in communication system tests to perform competitively with solid state and avalanche photodiodes. Signal-induced noise and III-V cathode stability were identified as remaining technical problems while cathode quantum efficiencies of or = 5% at 1.06 micron and 320 picosecond rise and fall time pulse performance were achieved.

Enck, R. S., Jr.↗

Field intercomparison of a novel optical sensor for formaldehyde quantification

A one-week in situ intercomparison campaign was completed on the Rice University campus for measuring HCHO using three different techniques, including a novel optical sensor based on difference frequency generation (DFG) operating at room temperature. Two chemical derivatization methods, 2,4-dinitrophenylhydrazine (DNPH) and o-(2,3,4,5,6-pentafluorobenzyl) hydroxylamine (PFBHA), were deployed during the daylight hours for three- to four-hour time-integrated samples. A real-time optical sensor based on laser absorption spectroscopy was operated simultaneously, including nighttime hours. This tunable spectroscopic source based on difference frequency mixing of two fiber-amplified diode lasers in periodically poled LiNb03 (PPLN) was operated at 3.5315 micrometers (2831.64 cm 1) to access a strong HCHO ro-vibrational transition free of interferences from other species. The results showed a bias of -1.7 and -1.2 ppbv and a gross error of 2.6 and 1.5 ppbv for DNPH and PFBHA measurements, respectively, compared with DFG measurements. These results validate the DFG sensor for time-resolved measurements of HCHO in urban areas.

NASA Discipline Life Sciences Technologies↗

A wavelength scannable XeCl oscillator-ring amplifier laser system

A holographic grating at grazing angle of incidence was used to achieve tunable, narrow bandwidth (0.005 nm) operation of a XeCl oscillator for injection locking of a ring amplifier. The amplifier's narrow bandwidth output energy was constant and equal to the untuned, broadband output (approximately 15 mJ) in regions where injection locking was achieved. Scanning was provided by use of a stepping motor-driven differential micrometer on the tuning mirror. This system was used to produce a laser excitation spectrum of hydroxyl radicals (OH) in a flame.

Pacala, T. J.↗

Free electron lasers for transmission of energy in space

A one-dimensional resonant-particle model of a free electron laser (FEL) is used to calculate laser gain and conversion efficiency of electron energy to photon energy. The optical beam profile for a resonant optical cavity is included in the model as an axial variation of laser intensity. The electron beam profile is matched to the optical beam profile and modeled as an axial variation of current density. Effective energy spread due to beam emittance is included. Accelerators appropriate for a space-based FEL oscillator are reviewed. Constraints on the concentric optical resonator and on systems required for space operation are described. An example is given of a space-based FEL that would produce 1.7 MW of average output power at 0.5 micrometer wavelength with over 50% conversion efficiency of electrical energy to laser energy. It would utilize a 10 m-long amplifier centered in a 200 m-long optical cavity. A 3-amp, 65 meV electrostatic accelerator would provide the electron beam and recover the beam after it passes through the amplifier. Three to five shuttle flights would be needed to place the laser in orbit.

Segall, S. B.↗

Determination of H2O and CO2 concentrations in fluid inclusions in minerals using laser decrepitation and capacitance manometer analysis

Water and carbon dioxide concentrations within individual and selected groups of fluid inclusions in quartz were analyzed by using laser decrepitation and quantitative capacitance manometer determination. The useful limit of detection (calculated as ten times the typical background level) is about 5 x 10(-10) mol of H2O and 5 x 10(-11) mol of CO2; this H2O content translates into an aqueous fluid inclusion approximately 25 micrometers in diameter. CO2/H2O determinations for 38 samples (100 separate measurements) have a range of H2O amounts of 5.119 x 10(-9) to 1.261 x 10(-7) mol; CO2 amounts of 7.216 x 10(-10) to 1.488 x 10(-8) mol, and CO2/H2O mole ratios of 0.011 to 1.241. Replicate mole ratio determinations of CO2/H2O for three identical (?) clusters of inclusions in quartz have average mole ratios of 0.0305 +/- 0.0041 1 sigma. Our method offers much promise for analysis of individual fluid inclusions, is sensitive, is selective when the laser energy is not so great as to melt the mineral (laser pits approximately 50 micrometers in diameter), and permits rapid analysis (approximately 1 h per sample analysis).

Water/analysis↗

Far-Infrared Hydrogen Lasers in the Peculiar Star MWC 349A

Far-infrared hydrogen recombination lines H15(alpha)(169.4 micrometers), H12(alpha)(88.8 micrometers), and H10(alpha)(52.5 micrometers) were detected in the peculiar luminous star MWC 349A from the Kuiper Airborne Observatory. Here it is shown that at least H15(alpha) is strongly amplified, with the probable amplification factor being greater than or about equal to 10(exp 3) and a brightness temperature that is greater than or about equal to 10(exp 7) kelvin. The other two lines also show signs of amplification, although to a lesser degree. Beyond H10(alpha) the amplification apparently vanishes. The newly detected amplified lines fall into the laser wavelength domain. These lasers, as well as the previously detected hydrogen masers may originate in the photoionized circumstellar disk of MWC 349A and constrain the disk's physics and structure.

Strelnitski, Vladimir↗

A relative performance analysis of atmospheric Laser Doppler Velocimeter methods.

Evaluation of the effectiveness of atmospheric applications of a Laser Doppler Velocimeter (LDV) at a wavelength of about 0.5 micrometer in conjunction with dual scatter LDV illuminating techniques, or at a wavelength of 10.6 micrometer with local oscillator LDV illuminating techniques. Equations and examples are given to provide a quantitative basis for LDV system selection and performance criteria in atmospheric research. The comparative study shows that specific ranges and conditions exist where performance of one of the methods is superior to that of the other. It is also pointed out that great care must be exercised in choosing system parameters that optimize a particular LDV designed for atmospheric applications.

Farmer, W. M.↗

An optical radar for airborne use over natural waters

An optical radar for detecting targets in natural waters was built and tested in the Gulf of Mexico. The transmitter consists of a Q switched neodymium glass laser, with output amplified and doubled in KDP to 0.53 micrometer wavelength. The receiver incorporates a noval optical spatial filter to reduce the dynamic range required of the photodetector to a reasonable value. Detection of targets to a depth of 26 meters (84 feet) was achieved with a considerable sensitivity margin. The sensitivity of the radar is highly dependent on the optical attenuation coefficient. In general, measured returns fell between the values predicted on the basis of monopath and multipath attenuation. By means of simple physical arguments, a radar equation for the system was derived. To validate this theoretical model, measurements of optical attenuation and of water surface behavior were also instrumented, and some of these results are given.

Levis, C. A.↗

Remote measurement of ClO in the stratosphere

ClO has been detected in the stratosphere from observations of the solar spectrum in the infrared, in a small spectral interval near 12 micrometers. The observations were made with a balloon-borne laser heterodyne radiometer, launched from Palestine, Texas on September 20. By comparing high sun spectra with a number of sequential spectra taken during sunset, an altitude profile has been calculated in the 29-38 km altitude range. The results show a peak mixing ratio in excess of one ppb above 34 km, and a rapid decrease in mixing ratio with decreasing altitude below 34 km.

Menzies, R. T.↗

Reliability improvements in tunable Pb1-xSnxSe diode lasers

Recent developments in the technology of Pb-salt diode lasers which have led to significant improvements in reliability and lifetime, and to improved operation at very long wavelengths are described. A combination of packaging and contacting-metallurgy improvements has led to diode lasers that are stable both in terms of temperature cycling and shelf-storage time. Lasers cycled over 500 times between 77 K and 300 K have exhibited no measurable changes in either electrical contact resistance or threshold current. Utilizing metallurgical contacting process, both lasers and experimental n-type and p-type bulk materials are shown to have electrical contact resistance values that are stable for shelf storage periods well in excess of one year. Problems and experiments which have led to devices with improved performance stability are discussed. Stable device configurations achieved for material compositions yielding lasers which operate continuously at wavelengths as long as 30.3 micrometers are described.

Linden, K. J.↗

Diagnosis Of A Pressure-Modulator-Radiometer Cell

Spectral response of pressure-modulator-radiometer cell measured with help of lead-salt tunable diode laser. Laser chosen because of narrow bandwidths {2 x 10 to negative 4th power (cm) to negative 1st power} and relatively high powers (up to 1 mW continuous) of such lasers and because available for wavelengths from 3 to 30 micrometers. Direct measurement of spectral response enables formulation of more-precise atmospheric-transmission functions, enabling extraction of better information from readings taken with instrument.

May, Randy D.↗