Search NASA⌕ Search

SEARCH · Search NASA

Results for “Latent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Python codes for the paper - "Trade-offs in the latent representation of microstructure evolution"

SAND2024-00946O Python codes used in "Trade-offs in the latent representation of microstructure evolution," a manuscript accepted for publication in Acta Materialia, are part of a repository. The code was developed to perform analysis of microstructure evolution. The repository consists of two main directories: models, which train and test models such as autoencoders and diffusion maps, and analysis, which analyzes microstructures. Source code is used to perform dimensionality reduction of microstructure data for analysis of its evolution in time. Sandia National Laboratories is a multimission laboratory managed and operated by National Technology & Engineering Solutions of Sandia, LLC, a wholly owned subsidiary of Honeywell International Inc., for the U.S. Department of Energy’s National Nuclear Security Administration under contract DE-NA0003525.

Dingreville, Remi↗

A direct contact cooler design for simultaneously recovering latent heat and capturing SO x and NO x from pressurized flue gas

Integrated SO x and NO x removal technology using a direct contact cooler is a promising alternative for cleaning coal combustion flue gas, especially for pressurized combustion systems. Past investigations of integrated SO x and NO x removal have been limited to low-temperature processes, where the flue gas has been cooled upstream of the removal unit, and the moisture in the flue gas has been condensed out. Here this work presents a novel design that recovers the flue gas heat while simultaneously removing SO x and NO x in a single reactive-absorption column – direct contact cooler. A validated model was used to evaluate different direct contact cooler designs. Modeling results suggested that a counter-current column with a single water inlet can scrub 83% of the NO x and 96.5% of the SO x in 115 s, while an optimized design with multiple water inlets enhances the scrubbing of NO x by 9 percentage points and SO x by 3.5 percentage points, due to a 34% increase in residence time. It is also observed that the liquid-phase reaction between absorbed SO x and NO x plays a significant role in the removal of SO 2 from the flue gas for high-temperature scrubbing compared with low-temperature scrubbing. The design reinforces the potential of high-temperature SO x -NO x removal and heat recovery and suggests a means of reducing capital costs for such columns.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Latent Tracks in Ion-Irradiated LiTaO 3 Crystals: Damage Morphology Characterization and Thermal Spike Analysis

Systematic research on the response of crystal materials to the deposition of irradiation energy to electrons and atomic nuclei has attracted considerable attention since it is fundamental to understanding the behavior of various materials in natural and manmade radiation environments. This work examines and compares track formation in LiTaO3 induced by separate and combined effects of electronic excitation and nuclear collision. Under 0.71–6.17 MeV/u ion irradiation with electronic energy loss ranging from 6.0 to 13.8 keV/nm, the track damage morphologies evolve from discontinuous to continuous cylindrical zone. Based on the irradiation energy deposited via electronic energy loss, the subsequently induced energy exchange and temperature evolution processes in electron and lattice subsystems are calculated through the inelastic thermal spike model, demonstrating the formation of track damage and relevant thresholds of lattice energy and temperature. Combined with a disorder accumulation model, the damage accumulation in LiTaO3 produced by nuclear energy loss is also experimentally determined. The damage characterizations and inelastic thermal spike calculations further demonstrate that compared to damage-free LiTaO3, nuclear-collision-damaged LiTaO3 presents a more intense thermal spike response to electronic energy loss owing to the decrease in thermal conductivity and increase in electron–phonon coupling, which further enhance track damage.

36 MATERIALS SCIENCE↗

Dynamic Modeling of Latent Heat Thermal Battery

A dynamic thermodynamic model is constructed in Modelica for the thermal battery portion of a heat pipe integrated thermal battery and is demonstrated using a shakedown test. The model is also leveraged to inform aspects of an experiment configuration. The theory section discusses modeling assumptions of the thermal battery system, establishes how melting and fusing is calculated, and how internal convection is modeled within the thermal battery. The shakedown test uses three charge-standby-discharge-standby cycles in which the charging cycles are 10 hours in length and the discharge cycles are 8 hours. System behavior including heat loss, temperature distributions and divergences, and internal convection behavior are presented. The model is then leveraged to show how experiment design can be informed through testing the model for insulation thickness impact on heat loss, round trip efficiency calculation, and heat tracing control.

25 ENERGY STORAGE↗

Quenching-Induced Defects Liberate the Latent Reversible Capacity of Lithium Titanate Anode

Interest in defect engineering for lithium-ion battery (LIB) materials is sparked by its ability to tailor electrical conductivity and introduce extra active sites for electrochemical reactions. However, harvesting excessive intrinsic defects in the bulk of the electrodes rather than near their surface remains a long-standing challenge. Here, a versatile strategy of quenching is demonstrated, which is exercised in lithium titanate (Li 4 Ti 5 O 12 , LTO), a renowned anode for LIBs, to achieve off-stoichiometry in the interior region. In situ synchrotron analysis and atomic-resolution microscopy reveal the enriched oxygen vacancies and cation redistribution after ice-water quenching, which can facilitate the native unextractable Li ions to participate in reversible cycling. Further, the fabricated LTO anode delivers a sustained capacity of 202 mAh g -1 in the 1.0–2.5 V range with excellent rate capability and overcomes the poor cycling stability seen in conventional defective electrodes. The feasibility of tuning the degree of structural defectiveness via quenching agents is also proven, which can open up an intriguing avenue of research to harness the intrinsic defects for improving the energy density of rechargeable batteries.

25 ENERGY STORAGE↗

Human‐Skin‐Inspired Adaptive Smart Textiles Capable of Amplified Latent Heat Transfer for Thermal Comfort

Thermally adaptive textiles (TATs) enable human subjects to attain thermal comfort without energy consumption, which can lead to enormous energy savings on heating, ventilation, and air conditioning (HVAC) in buildings. Herein, TAT structures which respond to the sweat and generate pores by opening an array of flap‐shaped pores patterned on the fabric surface are proposed. A moisture‐driven self‐actuator for flap opening by constructing a bilayer consisting of a hygroscopic layer using polyethylene glycol and cellulose acetate, and a hydrophobic polymer using a polyester type polymer, is used and successfully demonstrated an essentially instant 4 °C apparent temperature cooling performance within one minute of sweat–humidity‐initiated actuation while wearing TAT using a sweating skin simulated device.

Kim, Gunwoo↗

Design and performance assessment of a dual-mode latent thermal storage integrated heat pump across multiple climate zones

The electrification of space cooling and heating systems risks overloading the existing electrical grid during peak hours. Heat pumps integrated with thermal energy storage (HP-TES) offer a promising solution by shifting peak loads to off-peak hours, reducing grid strains. This work presents the design and assessment of a dual-mode HP-TES that uses a single 22°C phase-change material (PCM) as a heat source or sink in heating and cooling modes, respectively. Performance assessment was conducted using Modelica-based transient models, and full-year simulations were conducted across eight US climate zones using typical weather data. Two HP-TES performance metrics: peak energy reduction and recharge energy increases, were defined by comparing HP-TES energy consumption with base HP peak consumptions. Annual heating demand reductions (40–65%) exceeded cooling demand reductions (15–20%) due to the elimination of peak-hour backup heating. Cooling mode recharge energy requirements (0–10%) were reduced in locations with lower summer nighttime temperatures, while heating recharge requirements were lower than the high base-peak energy demand from backup heating. Simplified rapid methods that were 10 7 times faster than annual simulations were developed to predict seasonal cooling and heating energy reductions, and recharge energy requirements, with maximum deviations of ±2.5% and ±3.5% points. These methods enabled rapid parametric studies that identified optimal location-specific PCM temperatures between 22°C and 27°C, highlighting the need to consider both discharge and recharge energy requirements to achieve sustainable, energy-efficient peak load shifting across various climate zones.

25 ENERGY STORAGE↗