Search NASA⌕ Search

SEARCH · Search NASA

Results for “Linear accelerator structures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Femtosecond multimodal imaging with a laser-driven X-ray source

Laser-plasma accelerators are compact linear accelerators based on the interaction of high-power lasers with plasma to form accelerating structures up to 1000 times smaller than standard radiofrequency cavities, and they come with an embedded X-ray source, namely betatron source, with unique properties: small source size and femtosecond pulse duration. A still unexplored possibility to exploit the betatron source comes from combining it with imaging methods able to encode multiple information like transmission and phase into a single-shot acquisition approach. In this work, we combine edge illumination-beam tracking (EI-BT) with a betatron X-ray source and present the demonstration of multimodal imaging (transmission, refraction, and scattering) with a compact light source down to the femtosecond timescale. The advantage of EI-BT is that it allows multimodal X-ray imaging technique, granting access to transmission, refraction and scattering signals from standard low-coherence laboratory X-ray sources in a single shot.

43 PARTICLE ACCELERATORS↗

An approach to multiobjective optimization of rotational therapy

Multiobjective optimization is used in radiotherapy, especially IMRT, to generate treatment plans which meet different objectives to varying extents. Trade-off surfaces can be constructed representing the gains and losses of different objectives when switching from one plan to another, and the planner can interactively explore different treatment possibilities without the need for reoptimization. In this work a method for the multiobjective optimization of rotational therapy is introduced. The proposed method is applied slice per slice and uses the geometry of the slice directly to construct several arcs, each conformally irradiating the tumor and blocking a number (0,1,2,...) of different organs at risk present in the treatment. The blocked arc dose distributions so obtained are quite inhomogeneous in the target. An algorithm, based on the iterative reconstruction of images from projections, has been developed to compensate for this inhomogeneity, leading to compensated blocked arcs which deliver more uniform target doses but still block critical structures. Different treatments can be obtained as linear combinations of these arcs, each involving different trade-offs among the objectives involved. The compensatory algorithm substantially improves the target dose uniformity of blocked arcs at the cost of slightly increasing the dose to the rest of the body, allowing delivery of good uniform dose distributions to the target without significantly irradiating the blocked organ(s). Trade-off surfaces are presented for slices containing a target and one or two critical structures. The method is directly implementable using axial or helical tomotherapy. Implementation for conventional linear accelerators will be more difficult because the number of arcs needed to deliver such treatments can be large, an issue to be explored in future work.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Introduction to Superconducting RF Structures and the Effect of High Pressure Rinsing

This presentation begins by describing RF superconductivity and SRF accelerating structures. Then the use of superconducting RF structures in a number of accelerators around the world is reviewed; for example, the International Linear Collider (ILC) will use ~16,000 SRF cavities with ~2,000 cryomodules to get 500 GeV e⁺/e⁻ colliding energy. Field emission control was (and still is) a very important practical issue for SRF cavity development. It has been found that high-pressure ultrapure water rinsing as a final cleaning step after chemical surface treatment resulted in consistent performance of single- and multicell superconducting cavities.

43 PARTICLE ACCELERATORS↗

Higher Order Modes for Beam Diagnostics in Third Harmonic 3.9 GHz Accelerating Module

An international team is currently investigating the best way to use Higher Order Modes (HOM) for beam diagnostics in 3.9 GHz cavities. HOMs are excited by charged particles when passing through an accelerating structure. Third harmonic cavities working at 3.9 GHz have been installed in FLASH to linearize the bunch energy profile. A proof-of-principle of using HOMs for beam monitoring has been made at FLASH in the TESLA 1.3 GHz cavities. Since the wakefields generated in the 3.9 GHz cavities are significantly larger, their impact on the beam should be carefully minimized. Therefore our target is to monitor HOMs and minimize them by aligning the beam on the cavity axis. The difficulty is that, in comparison to the 1.3 GHz cavities, the HOM-spectrum is dense, making it difficult to identify individual modes. Also, most modes propagate through the whole cryo-module containing several cavities, making it difficult to measure local beam properties. In this paper the options for the HOM-based beam position monitors are discussed.

Baboi, N.↗

A New Accelerator Structure Concept: The Zipper Structure

I introduce a novel normal-conducting accelerator structure combining standing wave and traveling wave characteristics, with relatively open cells. I describe the concept and geometry, optimize parameters, and discuss the advantages and limitations this new structure presents.

43 PARTICLE ACCELERATORS↗

High Gradient Accelerating Structures for Carbon Therapy Linac

Carbon therapy is the most promising among techniques for cancer treatment, as it has demonstrated significant improvements in clinical efficiency and reduced toxicity profiles in multiple types of cancer through much better localization of dose to the tumor volume. RadiaBeam, in collaboration with Argonne National Laboratory, are developing an ultra-high gradient linear accelerator, Advanced Compact Carbon Ion Linac (ACCIL), for the delivery of ion-beams with end-energies up to 450 MeV/u for 12C6+ ions and 250 MeV for protons. In this paper, we present a thorough comparison of standing and travelling wave designs for high gradient S-Band accelerating structures operating with ions at varying velocities, relative to the speed of light, in the range 0.3-0.7. In this paper we will compare these types of accelerating structures in terms of RF, beam dynamics and thermo-mechanical performance.

Kutsaev, Sergey↗

The SPES project: an ISOL facility for exotic beams

SPES (Selective Production of Exotic Species) is an INFN project to develop a Radioactive Ion Beam (RIB) facility as an intermediate step toward EURISOL. The SPES project is part of the INFN Road Map for the Nuclear Physics development in Italy and is supported by the whole Italian Nuclear Physics community and mainly by LNL and LNS the INFN National Laboratories of Nuclear Physics in Legnaro and Catania. The Laboratori Nazionali di Legnaro (LNL) was chosen as the site for the facility construction due to the presence of the PIAVE-ALPI accelerator complex, which will be used as re-accelerator for the RIBs. The SPES project is based on the ISOL method with an UCx Direct Target and makes use of a proton driver of at least 40 MeV energy and 200 microA current. Neutron-rich radioactive beams will be produced by Uranium fission at an expected fission rate in the target in the order of 10{sup 13} fissions per second. The key feature of SPES is to provide high intensity and high-quality beams of neutron rich nuclei to perform forefront research in nuclear structure, reaction dynamics and interdisciplinary fields like medical, biological and material sciences. The exotic isotopes will be re-accelerated by the ALPI superconducting linac at energies up to 10 AMeV for masses in the region of A = 130 amu with an expected rate on target of 10{sup 9} pps.

43 PARTICLE ACCELERATORS↗

Design and Analysis of a Double Wall, Water Cooled Window for Accelerator Based Mo-99 Production

The electron accelerator based Mo-99 production technique requires the use of Rhodotrons to generate 38 MeV, 6.32 mA pulsed electron beams. The introduction of the pulsed beam structure has introduced fatigue concerns in the vacuum-helium windows that did not exist previously for electron beam production via linear accelerators. Previous analysis has shown that temperature fluctuations of approximately 100°C above and below the steady state operating temperature of ~500°C will occur within the windows. A water cooled window will eliminate this concern by reducing the primary mechanical stress due to the 300-psig helium pressure load as well as the secondary thermally induced stress. Although a water cooled window was considered years ago, the complexities of adding an additional water line was unattractive until now. A double wall, water cooled window has been designed and analyzed for this reason. The water cooled window design is shown to decrease the helium-side window temperature to as low as 125°C, while the vacuum-side window is maintained at 161°C at a water flow rate of 3.2 GPM. These low steady state temperatures reduce the thermal stress of the helium-side window significantly. Also, the primary mechanical stress has been reduced by roughly 50% due to the reduced pressure gradient across the helium-side window (150-psig water and 300-psig helium). Considering a Mo-99 production loss of roughly 1%, the water cooled window is a drastic improvement over the previous helium cooled designs and should be greatly considered for future upgrades and redesign.

43 PARTICLE ACCELERATORS↗

Proton and deuteron F 2 structure function at low Q 2

Measurements of the proton and deuteron F 2 structure functions are presented. The data, taken at Jefferson Lab Hall C, span the four-momentum transfer range 0.06 2 <2.8GeV 2 and Bjorken x values from 0.009 to 0.45, thus extending the knowledge of F 2 to low values of Q 2 at low x. Next-to-next-to-leading-order calculations using recent parton distribution functions start to deviate from the data for Q 2 <2 GeV 2 at the low and high x values. Down to the lowest value of Q 2 , the structure function is in good agreement with a parametrization of F 2 based on data that have been taken at much higher values of Q 2 or much lower values of x, and which are constrained by data at the photon point. The ratio of the deuteron and proton structure functions at low x remains well described by a logarithmic dependence on Q 2 at low Q 2 .

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A novel design of iron dominated superconducting multipole magnets with circular coils

Linear accelerators based on superconducting magnet technology use a large number of relatively weak superconducting quadrupoles. In this case an iron dominated quadrupole is the most cost effective solution. The field quality in this magnet is defined by iron poles; the magnet air gap is minimal as are coil ampere-turns. Nevertheless, it has long racetrack type coils, which must be rigid and fixed by a mechanical structure to provide the needed mechanical stability. The novel concept of using circular superconducting coils in such a quadrupole type is described, with a discussion of quadrupole parameters, and results of 3D magnetic designs. Variants of short and long sectional quadrupoles and multipoles are presented.

43 PARTICLE ACCELERATORS↗

Whitepaper submitted to Snowmass21: Advanced accelerator linear collider demonstration facility at intermediate energy

It is widely accepted that the next lepton collider beyond a Higgs factory would require center-of-mass energy of the order of up to 15 TeV. Since, given reasonable space and cost restrictions, conventional accelerator technology reaches its limits near this energy, high-gradient advanced acceleration concepts are attractive. Advanced and novel accelerators (ANAs) are leading candidates due to their ability to produce acceleration gradients on the order of 1--100~GV/m, leading to compact acceleration structures. Over the last 10-15 years significant progress has been achieved in accelerating electron beams by ANAs. For example, the demonstration of several-GeV electron beams from laser-powered capillary discharge waveguides, as well as the proof-of-principle coupling of two accelerating structures powered by different laser pulses, has increased interest in ANAs as a viable technology to be considered for a compact, TeV-class, lepton linear collider. However, intermediate facilities are required to test the technology and demonstrate key subsystems. A 20-100 GeV center-of-mass energy ANA-based lepton collider can be a possible candidate for an intermediate facility. Apart from being a test beam facility for accelerator and detector studies, this collider will provide opportunities to study muon and proton beam acceleration, investigate charged particle interactions with extreme electromagnetic fields (relevant for beam delivery system designs and to study the physics at the interaction point), as well as precision Quantum Chromodynamics and Beyond the Standard Model physics measurements. Possible applications of this collider include the studies of $\gamma\gamma$ and $e$-ion collider designs.

43 PARTICLE ACCELERATORS↗

Batched Sparse Linear Algebra (Final Report for Subcontract B648960)

This report finalizes design specifications for developing batched kernels for small tensor operations for unassembled matrix-free iterative solvers, batched solvers for partially assembled operators, and batched solvers with support for various sparse formats. The outcome of the project milestones is a set of interfaces to Batched Sparse LA solvers running on hardware accelerators for use in ECP Libraries and Applications. It is part of the development of sparse batched kernels, solvers/preconditioners as well as creating interoperability in xSDK libraries with sparse and dense batched functions to benefit ECP applications. The participants included representatives from ECP libraries (not limited to the xSDK project), applications, and vendors (AMD, Intel, and NVIDIA). Batched sparse linear algebra solvers form the new frontier for algorithmic development and performance engineering. Many applications (ECP and non-ECP alike) require simultaneous solutions of small linear systems of equations that are structurally sparse. To move towards high hardware utilization, it is important to provide these applications with appropriate interfaces to efficient batched sparse solvers running on modern hardware accelerators. We present interface designs in use by HPC software libraries supporting batched sparse linear algebra and the development of sparse batched kernel codes for solvers and preconditioners. We also address the potential interoperability opportunities to keep the software portable between the major hardware accelerators from AMD, Intel, and NVIDIA. The presented interface specifications includes batched band, sparse iterative, and sparse direct solvers. This report summarizes progress in Kokkos Kernels and the xSDK libraries MAGMA, Ginkgo, hypre, SUNDIALS, and SuperLU_dist.

97 MATHEMATICS AND COMPUTING↗

Phase Rotation Scheme To Combine an RF Technique With Laser-Plasma Interaction For Real Applications Of Laser-Produced Ions

A phase rotation scheme of laser-produced ions from a solid target by the application of a synchronized RF electric voltage with a pulsed laser has been experimentally investigated with the use of a 100 TW laser, J-KAREN at JAEA, KPSI. Up to now, energy peaks of up to around 2.0 MeV have been created with a FWHM of 2.6% with good reproducibility using a two-gap resonator of a quarter wave length with the same frequency as the source laser (approx80 MHz). It is also found that the position of the peak can be well controlled by adjusting the relative phase between the RF electric field and the laser, which is very promising for real applications of such laser-produced protons. In order to also apply such a phase rotation system for higher energy protons (<200 MeV), a scheme to use a small linear accelerator (LINAC) with multi-gaps is proposed as a phase rotator. With multi-gap structure, alternating focusing between longitudinal and transverse degrees of freedoms can be realized. From the point of compactness and realizing a small focused spot, however, a scheme combining separate quadrupole magnets just before and after the RF cavity excited with the Wideroee mode, might be more effective. The scheme presented here will realize laser-produced ions (protons) with good reproducibility by combining with RF technology.

43 PARTICLE ACCELERATORS↗

Measurement and modeling of the effect of support arm backscatter on dosimetry with a Varian EPID

Purpose: Amorphous silicon EPIDs have been used for planar dose verification in IMRT treatments for many years. The support arm used to attach some types of EPIDs to linear accelerators can introduce inaccuracies to dosimetry measurements due to the presence of metallic parts in their structures. It is demonstrated that this uncertainty may be as large as {approx}6% of maximum image signal for large fields. In this study, a method has been described to quantify, model and correct for the effect of backscattered radiation from the EPID support arm (E-Arm type, Varian Medical Systems). Methods: Measurements of a support arm backscatter kernel were made using several 1x1 cm{sup 2} 6 MV pencil beam irradiations at a sample of positions over the sensitive area of the EPID in standard clinical setup and repeated with the EPID removed from the support arm but at the same positions. A curve-fit to the subtraction of EPID response obtained on and off the arm was used to define the backscatter kernel. The measured kernel was compared with a backscatter kernel obtained by Monte Carlo simulations with EGS/BEAM code. A backscatter dose prediction using the measured backscatter kernel was added to an existing EPID dose prediction model. The improvement in the agreement of the modified model predictions with EPID measurements for a number of open fields and IMRT beams were investigated by comparison to the original model results. Results: Considering all functions tested to find the best functional fit to the data points, a broad Gaussian curve proved to be the optimum fit to the backscatter data. The best fit through the Monte Carlo simulated backscatter kernel was also found to be a Gaussian curve. The maximum decrease in normalized root mean squared deviation of the measured and modeled EPID image profiles for open fields was 13.7% for a 15x15 cm{sup 2} field with no decrease observed for a 3x3 cm{sup 2} (the smallest) field as it was not affected by the arm backscatter. Gamma evaluation (2%, 2 mm criteria) showed the improvement in agreement between the model and measurement results when the backscatter was incorporated. The average increase in Gamma pass rate was 2% for head and neck and 1.3% for prostate IMRT fields investigated in this study. Conclusions: The application of the backscatter kernel determined in this study improved the accuracy of dosimetry using a Varian EPID with E-arm for open fields of different sizes: Eight head and neck and seven prostate IMRT fields. Further improvement in the agreement between the model predictions and EPID measurements requires more sophisticated modeling of the backscatter.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-F-T-227: A Comprehensive Patient Specific, Structure Specific, Pre-Treatment 3D QA Protocol for IMRT, SBRT and VMAT - Clinical Experience

Purpose: To present a 3D QA method and clinical results for 550 patients. Methods: Five hundred and fifty patient treatment deliveries (400 IMRT, 75 SBRT and 75 VMAT) from various treatment sites, planned on Raystation treatment planning system (TPS), were measured on three beam-matched Elekta linear accelerators using IBA’s COMPASS system. The difference between TPS computed and delivered dose was evaluated in 3D by applying three statistical parameters to each structure of interest: absolute average dose difference (AADD, 6% allowed difference), absolute dose difference greater than 6% (ADD6, 4% structure volume allowed to fail) and 3D gamma test (3%/3mm DTA, 4% structure volume allowed to fail). If the allowed value was not met for a given structure, manual review was performed. The review consisted of overlaying dose difference or gamma results with the patient CT, scrolling through the slices. For QA to pass, areas of high dose difference or gamma must be small and not on consecutive slices. For AADD to manually pass QA, the average dose difference in cGy must be less than 50cGy. The QA protocol also includes DVH analysis based on QUANTEC and TG-101 recommended dose constraints. Results: Figures 1–3 show the results for the three parameters per treatment modality. Manual review was performed on 67 deliveries (27 IMRT, 22 SBRT and 18 VMAT), for which all passed QA. Results show that statistical parameter AADD may be overly sensitive for structures receiving low dose, especially for the SBRT deliveries (Fig.1). The TPS computed and measured DVH values were in excellent agreement and with minimum difference. Conclusion: Applying DVH analysis and different statistical parameters to any structure of interest, as part of the 3D QA protocol, provides a comprehensive treatment plan evaluation. Author G. Gueorguiev discloses receiving travel and research funding from IBA for unrelated to this project work. Author B. Crawford discloses receiving travel funding from IBA for unrelated to this project work.

60 APPLIED LIFE SCIENCES↗

Kinetic Scale Structure of Low-frequency Waves and Fluctuations

The dissipation of solar wind turbulence at kinetic scales is believed to be important for the heating of the corona and for accelerating the wind. The linear Vlasov kinetic theory is a useful tool for identifying various wave modes, including kinetic Alfvén, fast magnetosonic/whistler, and ion-acoustic (or kinetic slow), and their possible roles in the dissipation. However, the kinetic mode structure in the vicinity of ion-cyclotron modes is not clearly understood. The present paper aims to further elucidate the structure of these low-frequency waves by introducing discrete particle effects through hybrid simulations and Klimontovich formalism of spontaneous emission theory. The theory and simulation of spontaneously emitted low-frequency fluctuations are employed to identify and distinguish the detailed mode structures associated with ion-Bernstein modes versus quasi-modes. The spontaneous emission theory and simulation also confirm the findings of the Vlasov theory in that the kinetic Alfvén waves can be defined over a wide range of frequencies, including the proton cyclotron frequency and its harmonics, especially for high-beta plasmas. This implies that these low-frequency modes may play predominant roles even in the fully kinetic description of kinetic scale turbulence and dissipation despite the fact that cyclotron harmonic and Bernstein modes may also play important roles in wave–particle interactions.

79 ASTRONOMY AND ASTROPHYSICS↗

TWO-STREAM-LIKE INSTABILITY IN DILUTE HOT RELATIVISTIC BEAMS AND ASTROPHYSICAL RELATIVISTIC SHOCKS

Relativistic collisionless shocks are believed to be efficient particle accelerators. Nonlinear outcome of the interaction of accelerated particles that run ahead of the shock, the so-called precursor, with the unperturbed plasma of the shock upstream, is thought to facilitate additional acceleration of these particles and to possibly modify the hydrodynamic structure of the shock. We explore here the linear growth of kinetic modes appearing in the precursor-upstream interaction in relativistic shocks propagating in non- and weakly magnetized plasmas: electrostatic two-stream parallel mode and electrostatic oblique modes. The physics of the parallel and oblique modes is similar, and thus, we refer to the entire spectrum of electrostatic modes as 'two-stream-like'. These modes are of particular interest because they are the fastest growing modes known in this type of system. Using a simplified distribution function for a dilute ultrarelativistic beam that is relativistically hot in its own rest frame, yet has momenta that are narrowly collimated in the frame of the cold upstream plasma into which it propagates, we identify the fastest growing mode in the full k-space and calculate its growth rate. We consider all types of plasma (pairs and ions-electrons) and beam (charged and charge-neutral). We find that unstable electrostatic modes are present in any type of plasma and for any shock parameters. We further find that two modes, one parallel (k{sub perpendicular} = 0) and the other one oblique (k{sub perpendicular} {approx} k{sub ||}), are competing for dominance and that either one may dominate the growth rate in different regions of the phase space. The dominant mode is determined mostly by the perpendicular spread of the accelerated particle momenta in the upstream frame, which reflects the shock Lorentz factor. The parallel mode becomes more dominant in shocks with lower Lorentz factors (i.e., with larger momentum spreads). We briefly discuss possible implications of our results for external shocks in gamma-ray burst sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Positrons at Jefferson Lab

We review the compelling case for establishing a capability to accelerate positrons at Jefferson Lab. The potential applications range from the study of two-photon exchange and deeply-virtual Compton scattering to exploiting the charged current weak interaction to probe the flavor structure of hadrons and nuclei. There are also fascinating ideas for using such a capability to discover new physics beyond the Standard Model of nuclear and particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗