Effect of geometric and motion tracking errors on awake small animal SPECT

A series of simulation studies were performed to evaluate the effects of geometric and motion tracking errors on reconstruction image quality for a single pinhole collimator awake animal imaging SPECT system. List-mode SPECT data generated using a custom Monte Carlo program that incorporated experimental mouse motion data were reconstructed by MLEM with Siddon's ray tracing. To better understand the impact of motion tracking and system geometric parameter errors on reconstructed system data, an offset of up to 1 mm or degree was separately applied to each for evaluation. In the absence of motion tracking or system geometric error, the applied motion compensation algorithm successfully reconstructed volumes without any degradation or distortion. Presented results reveal that motion tracking errors propagate through the SPECT reconstruction process. However, it is confirmed that the impact of tracking errors in the currently employed motion tracking system, is minimal because of their accuracy. The results also reveal the direct and indirect impact of geometric errors to motion compensated reconstruction quality and that a wrong assumption of pinhole transaxial position produces the most amount of distortion of all the investigated errors. Finally, system geometric errors are shown to have a greater impact on reconstruction quality than equivalent tracking errors.

60 APPLIED LIFE SCIENCES↗

Pulsed, Photonuclear-induced, Neutron Measurements of Nuclear Materials with Composite Shielding

Active measurements were performed using a 10-MeV electron accelerator with inspection objects containing various nuclear and nonnuclear materials available at the Idaho National Laboratory’s Zero Power Physics Reactor (ZPPR) facility. The inspection objects were assembled from ZPPR reactor plate materials to evaluate the measurement technologies for the characterization of plutonium, depleted uranium or highly enriched uranium shielded by both nuclear and non-nuclear materials. A series of pulsed photonuclear, time-correlated measurements were performed with unshielded calibration materials and then compared with the more complex composite shield configurations. The measurements used multiple 3He detectors that are designed to detect fission neutrons between pulses of an electron linear accelerator. The accelerator produced 10-MeV bremsstrahlung X-rays at a repetition rate of 125 Hz (8 ms between pulses) with a 4-us pulse width. All inspected objects were positioned on beam centerline and 100 cm from the X-ray source. The time-correlated data was collected in parallel using both a Los Alamos National Laboratory-designed list-mode acquisition system and a commercial multichannel scaler analyzer. A combination of different measurement configurations and data analysis methods enabled the identification of each object. This paper describes the experimental configuration, the ZPPR inspection objects used, and the various measurement and analysis results for each inspected object.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Experiments and Simulations of the Use of Time-Correlated Thermal Neutron Counting to Determine the Multiplication of an Assembly of Highly Enriched Uranium

A series of experiments and numerical simulations using thermal-neutron time-correlated measurements has been performed to determine the neutron multiplication, M, of assemblies of highly enriched uranium available at Idaho National Laboratory. The experiments used up to 14.4 kg of highly-enriched uranium, including bare assemblies and assemblies reflected with high-density polyethylene, carbon steel, and tungsten. A small 252Cf source was used to initiate fission chains within the assembly. Both the experiments and the simulations used 6-channel and 8-channel detector systems, each consisting of 3He proportional counters moderated with polyethylene; data was recorded in list mode for analysis. 'True' multiplication values for each assembly were empirically derived using basic neutron production and loss values determined through simulation. A total of one-hundred and sixteen separate measurements were performed using fifty-seven unique measurement scenarios, the multiplication varied from 1.75 to 10.90. This paper presents the results of these comparisons and discusses differences among the various cases.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Networked Gamma Radiation Detection System for Rapid Tactical Response

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2' × 4' × 16' sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart realtime localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We are testing a collection of algorithms and analysis on the problem of radiation detection with a distributed sensor network, examining such a network’s associated characteristics, and also the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, are being examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

false alarm rate↗

Uncertainty identification in mass estimation applications with imaging detectors

Mass quantification using standoff gamma imaging techniques is a boon to the special nuclear material holdup monitoring community, but before the method is deemed acceptable as a replacement for historical gamma detection-based methods, there are several considerable sources of uncertainty that must be addressed. These uncertainty sources have received sparse coverage in the literature, but provide the bulk of the uncertainty estimated in practice outside of standard counting statistics. For imaging, there is a fundamental difference between detection/localization and mass estimation operating modalities, where detection/localization can tolerate significantly larger uncertainty because the goal is detection of a distant source, rather than the quantification of that source. Historically, quantification requires a known geometry between source and detector, as well as a calibrated efficiency correction curve, which is well suited to laboratory practice for a stationary detector; however, this requires some corrections and assumptions (e.g., generalized geometry) for field applications, since additional degrees of freedom are present in the source-to-detector position, intervening materials, and non-uniform source distributions, when compared against the laboratory case. Use of an imaging detector during holdup measurements would address these issues by calculating the spatial geometry of the distant source as seen by the detector, with efficiency corrected according to the source-to-detector angle. While this aim promises a better estimation accuracy than generalized geometry assumptions, additional uncertainties are added from the imaging mechanism itself. Of these uncertainties, some are readily mitigated and methods to do so are included in the discussion, while some uncertainties are specific to the imaging class of instruments and are investigated and discussed in detail. Uncertainties are categorized into two general areas: instrument design and algorithmic. Instrument design-based uncertainties include basic detector characteristics for timing and energy resolution, handling of list mode data for coincidence detection, and geometric layout of and propagation of spatial uncertainty into imaging uncertainty. Algorithmic-based uncertainties discussed herein pertain to image reconstruction, the weight assignment problem from cone interactions, and the effects of spatial discretization on mass estimation. With these major sources of uncertainty identified, the path towards acceptance of imaging as a holdup monitoring method becomes clearer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Neutron Coincidence Measurements of Uranium-233 Oxide

Renewed international interest in thorium-fueled advanced reactors has challenged the safeguards community to address future proliferation concerns. Thorium-based technology presents many benefits but does not eliminate the proliferation risks associated with producing and processing fissile material. A byproduct of thorium-fueled reactors is uranium-233, which is classified as a direct-use material. As a result, the development of new or improved methods to characterize and measure materials containing 233U must mirror the pace of development of reactors and facilities that produce such material. Research is underway to assess, develop, and test approaches for safeguarding nuclear materials within the thorium fuel cycle. Neutron signatures from the nondestructive assay (NDA) of materials containing 233U are being quantified to inform the potential characterization of these materials. Using a traditional neutron coincidence counter and a series of well-documented 233U oxide samples, initial measurements have been made to assess the feasibility of 233U characterization and discrimination from other uranium isotopes, primarily 235U, using a combination of measurement techniques and analysis methods. Data acquisition is performed in list mode, allowing for a variety of analyses to be performed on the raw data that is not available using traditional shift register technology. Measurements were performed in passive and active configurations to quantify the strength of signal and to validate simulations in support of this work. This paper presents and discusses the results of the initial measurements of 233U oxide performed at Oak Ridge National Laboratory.

Lockhart, Madeline↗

Characterization of Canberra's Tomographic Gamma-Ray Can Scanner ('Can-TGS') - 13311

The Tomographic Gamma-ray Scanner (TGS) for large volume drummed waste has been successfully commercialized by Canberra over the last several years. As part of an R and D effort to continually improve this technology, we have developed a scaled down version of the standard commercial product (Can-TGS). The Can-TGS is able to accommodate cans and pails of various sizes, ranging from sub-liter to 20 liter volumes with densities of up to 4 g/cc. The Can-TGS has three diamond-shaped collimators (6.35 mm [0.25''], 12.7 mm [0.5''], and 25.4 mm [1'']) to facilitate a range of container volumes and heights. As with the standard TGS, the Can-TGS has a transmission source sub-system, where the transmission source can be easily swapped between sources of various strengths and type. The acquisition portion of the Can-TGS is powered by the Canberra Lynx{sup R} MCA which accommodates both multi-spectral scaling (MSS) and list-mode. Recently, the Can-TGS has been successfully characterized for an 18.93 L [5-gallon] container for the 25.4 mm diamond-shaped collimator. In principle, a single measurement (with good statistics) is required for each configuration in order to characterize the system. However, for this study, measurements were performed for several different matrices. For each matrix used, 6 different measurements were acquired. For each of these measurements, the drum was rotated 60 deg. with respect to the previous starting position. This procedure was followed in order to average out any radial bias that might be produced from just a single measurement. A description of the Can-TGS system is given. The details of the recent characterization measurements and the associated data analysis and results are presented. TGS results are compared with Segmented Gamma Scanner (SGS) results for the same source configuration. Additionally, the future outlook for Canberra's R and D efforts with this system is discussed. These efforts include TGS algorithm optimization, improving our understanding of the uncertainties associated with TGS results, and the overall benefits and limitations of this technology as compared to other available non-destructive assay techniques. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixelated CZT Technology for the Detection, Identification, and Localization of Gamma-Ray Sources - 18311

Radioactive waste-management applications require good measurements to qualitatively and quantitatively characterize waste materials. Often these measurements must be done in situ, and the user wishes to learn something of the isotopic and spatial distribution of the source. Therefore, there is a need for a portable instrument that can map radioactive contamination and quantify sources. This presentation introduces several instruments that have been applied to this task, along with example measurements in relevant applications. All instruments are based on 3D-position-sensitive CdZnTe (CZT) detectors. This technology routinely achieves better than 1.1% FWHM energy resolution at 662 keV and operates at room temperature with a startup time under 2 minutes. All are packaged in portable enclosures with WiFi and Bluetooth capabilities for wireless communication. These capabilities allow the technology to be used in more advanced measurements in the field. A unique capability of these detectors is the ability to image the spatial distribution of gamma rays from a single stationary measurement. The first product, Polaris-H, has been in use at commercial nuclear power plants since 2013. The system, currently used at over 50% of the US nuclear-power fleet, integrates a 3D-position-sensitive CZT detector, associated readout electronics, an embedded computer, a battery with over 7-hour life, an optical camera, and a laser range finder in a portable water-proof enclosure. The system connects wirelessly to a tablet which displays a gamma-ray spectrum and isotope-specific images of the gamma-ray distribution in all directions in real time. The CZT detectors have a dynamic range from 50 keV up to 3 MeV. Coded aperture or pinhole imaging is used for energies below 250 keV, and Compton imaging is used for energies above 250 keV. List-mode data is saved to an external USB memory stick to enable more advanced analysis, including isotopic activity analysis, via H3D's post-processing software. Additional systems based on the same architecture have been developed to optimize the technology for other applications. These include Polaris-H Quad, which provides over 3 times the sensitivity for applications involving weaker sources, and Polaris-H Shield, which uses a collimator to provide images and isotope information over a narrower field of view in order to measure weaker sources in the presence of stronger sources of the same isotope. H3D has also developed custom systems that have been mounted on robots and drones that enable remote operation of the technology. Results from the measurements collected at commercial nuclear power plants and other applicable sites will be presented to show how these instruments can be used to detect, identify, and localize gamma-ray sources. Advanced analysis techniques to show the accurate quantification of the gamma-ray source will also be presented. Applications range from characterizing simple objects, to locating hottest points, estimating contamination distributions on an isotope-by-isotope basis, and differentiating scatter and direct emissions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Application of Neutron Detection Third Order Time Correlation

Neutron noise experiments on fissile materials are used to get information such as reactivity, fissile mass, neutron sources, prompt neutron lifetime. One of the more popular methods is based on correlated moments of the neutron counts distribution. The second correlated moment method originally proposed by Feynman was extended to the third order. In this paper we present the application of the third order correlation moments method to SILENE reactor measurements. The third order correlation moments method has been applied to analyse time list mode - subcritical measurements on SILENE reactor in order to evaluate the system subcriticality, The multiplication coefficient is obtained with large statistical uncertainties, but remains consistent with MCNP calculations. To reduce the experimental uncertainties longer measurement time and higher detector efficiency should be necessary. The systematic errors coming from the fission neutron data (moments of the fission neutron distributions) and point model formulas should also be investigated. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Angular Correlations of Gamma Rays from Fission Product Solution

Fission products from photon-induced fission are routinely used at Idaho National Laboratory as part of nuclear forensics activities. Typically, the focus is on fission products with relatively large fission yields (Ba-140, Mo-99, etc.). The nuclear data associated with the well-known isotopes have small uncertainties, and many have well-known angular correlations between emitted gamma-rays, if applicable. However, for isotopes with smaller fission yields or less intense gamma-ray emission intensities, the nuclear decay schemes and gamma-ray emission intensities may be less well-known. The Germanium Rotational Measurements for Angular Correlation (GeRMAC) system was designed to use two high-purity germanium (HPGe) detectors in a coincidence counting set-up but allows one of the HPGe detectors to rotate at a constant distance from a radioactive source, changing the relative angle between the two HPGe detectors. Angular correlations can then be determined from the relative photopeak areas between two gamma-rays emitted as part of the same nuclear decay. By recording the HPGe spectra in list mode, the angular correlations of gamma-rays emitted from complex sources, consisting of multiple isotopes, can be measured simultaneously and the individual isotope emissions can be isolated. Using the GeRMAC system, a multi-isotope fission product source, produced with photon-induced fission of U-238, was measured using a single rotational arc (180 degrees) to obtain the angular correlation between gamma-rays emitted by the large number of fission products contained in the solution with an angular accuracy of 1 degree. In particular, La-140 (38 gamma rays) and Nd-147 (26 gamma rays) are of interest to the nuclear forensics community.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Verification of plutonium content in spent fuel assemblies using neutron self-interrogation

The large amounts of plutonium in reactor spent fuel assemblies has led to increased research directed toward the measurement of the plutonium for safeguards verification. The high levels of fission product gamma-ray activity and curium neutron backgrounds have made the plutonium measurement difficult. We have developed a new technique that can directly measure both the {sup 235}U concentration and the plutonium fissile concentration using the intrinsic neutron emission fronl the curium in the fuel assembly. The passive neutron albedo reactivity (PNAR) method has been described previously where the curium neutrons are moderated in the surrounding water and reflect back into the fuel assembly to induce fissions in the fissile material in the assembly. The cadmium (Cd) ratio is used to separate the spontaneous fission source neutrons from the reflected thermal neutron fission reactions. This method can measure the sum of the {sup 235}U and the plutonium fissile mass, but not the separate components. Our new differential die-away self-interrogation method (DDSI) can be used to separate the {sup 235}U from the {sup 239}Pu. The method has been applied to both fuel rods and full assemblies. For fuel rods the epi-thermal neutron reflection method filters the reflected neutrons through thin Cd filters so that the reflected neutrons are from the epi-cadmium energy region. The neutron fission energy response in the epi-cadmium region is distinctly different for {sup 235}U and {sup 239}Pu. We are able to measure the difference between {sup 235}U and {sup 239}Pu by sampling the neutron induced fission rate as a function of time and multiplicity after the initial fission neutron is detected. We measure the neutron fission rate using list-mode data collection that stores the time correlations between all of the counts. The computer software can select from the data base the time correlations that include singles, doubles, and triples. The die-away time for the doubles distribution is distinctly different for {sup 235}U and {sup 239}Pu. The {sup 239}Pu has a higher fission cross-section in the epi-cadmium neutron region and larger induced fission moments than {sup 235}U, so the measured die-away time can provide the relative amounts of {sup 239}Pu and {sup 235}U. This paper will present the Monte Carlo simulations for the detector and sample configurations for both fuel pins and full fuel assemblies.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Reusable rocket engine turbopump health monitoring system, part 3

Degradation mechanisms and sensor identification/selection resulted in a list of degradation modes and a list of sensors that are utilized in the diagnosis of these degradation modes. The sensor list is divided into primary and secondary indicators of the corresponding degradation modes. The signal conditioning requirements are discussed, describing the methods of producing the Space Shuttle Main Engine (SSME) post-hot-fire test data to be utilized by the Health Monitoring System. Development of the diagnostic logic and algorithms is also presented. The knowledge engineering approach, as utilized, includes the knowledge acquisition effort, characterization of the expert's problem solving strategy, conceptually defining the form of the applicable knowledge base, and rule base, and identifying an appropriate inferencing mechanism for the problem domain. The resulting logic flow graphs detail the diagnosis/prognosis procedure as followed by the experts. The nature and content of required support data and databases is also presented. The distinction between deep and shallow types of knowledge is identified. Computer coding of the Health Monitoring System is shown to follow the logical inferencing of the logic flow graphs/algorithms.

Perry, John G.↗

Meteorological Satellites (METSAT) and Earth Observing System (EOS) Advanced Microwave Sounding Unit-A (AMSU-A) Failure Modes and Effects Analysis (FMEA) and Critical Items List (CIL)

This Failure Modes and Effects Analysis (FMEA) is for the Advanced Microwave Sounding Unit-A (AMSU-A) instruments that are being designed and manufactured for the Meteorological Satellites Project (METSAT) and the Earth Observing System (EOS) integrated programs. The FMEA analyzes the design of the METSAT and EOS instruments as they currently exist. This FMEA is intended to identify METSAT and EOS failure modes and their effect on spacecraft-instrument and instrument-component interfaces. The prime objective of this FMEA is to identify potential catastrophic and critical failures so that susceptibility to the failures and their effects can be eliminated from the METSAT/EOS instruments.

Source record↗

Structural Verification of the Redesigned Space Shuttle Bipod Foam Closeout

This document outlines the structural verification approach for the Space Shuttle External Tank Forward Bipod Foam Closeout. Due to the Space Shuttle Columbia accident, debris has become a major concern. The intent of the structural verification is to ensure that any debris shed from the bipod is within acceptable limits. Since cohesive failure due to internal defects was identified as the most likely cause of the STS-107 bipod ramp foam failure, verification for this failure mode receives particular emphasis. However, all failure modes for TPS are considered and appropriate verification rationale is developed for each failure mode. Figure 1 depicts the structural verification of a production design where analysis and test are the primary methods of verification. It can be seen that the successful completion of structural verification is dependent on three main areas: 1. Production process control and quality assurance must ensure that test articles and/or analytical models are representative of (or conservatively envelope) production hardware in terms of geometry, materials and processing. Variability and defects must be considered. 2. Flight environments must be sufficiently characterized to bound driving environments for all failure modes. Applied environments, either test or analytical, must be representative of flight environments and have a load factor that satisfies design requirements. 3. Structural verification must include all failure modes. A comprehensive list of failure modes and the underlying failure mechanisms has been generated based on flight and test experience. Verification tests and / or analyses must address each failure mode. ET TPS Verification is accomplished by a combination of analysis, test, and similarity.

Poole, Eric L.↗

Frequencies of solar p-mode oscillations

A list is presented of frequencies that can be used as a basis for helioseismic investigations of the average structure of the solar interior as a function of depth. The list includes measurements of frequencies of p-mode multiplets covering the l range from 4 to 99. Two different data sets are employed: one based on Doppler shift measurements made in 1985 at the Big Bear Solar Observatory and another based on intensity measurements made in 1981 at the geographic South Pole. Frequencies from the two data sets are compared, and systematic frequency differences are found that range from less than 0.1 microHz at low values of l to about 0.6 microHz at l = 99; the uncertainty is + or - 0.1 microHz.

Duvall, T. L., Jr.↗

Time sequence gamma-spectrometry of irradiated salt

Persisted Memory Mapping File (MMF) techniques have developed for the processing and analysis of time-stamped list (TLIST) mode data collected from an irradiated salt sample. This is a new technique that is unique to this research and enables additional information to be obtained from a conventional pulse height analysis (PHA) gamma-spectrometry acquisition. A salt sample was irradiated using a DT neutron generator and immediately measured using TLIST acquisition for 1 month to generate a 22 GB data file. MMF techniques were used to process the file without size restrictions at a rate of 388.5 MB minute-1, with instant access to any position within the file, separating the file into a series of time sequenced spectra suitable for PHA analysis. This enabled 14 activation products to be identified at different time intervals (41Ar, 80Br, 80mBr, 47Ca, 34mCl, 38Cl, 42K, 43K, 56Mn, 22Na, 24Na, 85Sr, 87mSr and 69mZn), and 6 radionuclides (80Br, 47Ca, 34mCl, 56Mn, 24Na and 87mSr) to be definitively confirmed based upon their measured half-life. Using this technique, the detection of 47Ca, and in-growth of its 47Sc progeny, was demonstrated as useful for calculating the time since irradiation.

Burnett, Jonathan L.↗

Theoretical Studies of Alfven Waves and Energetic Particle Physics in Fusion Plasmas

This report summarizes major theoretical findings in the linear as well as nonlinear physics of Alfvén waves and energetic particles in magnetically confined fusion plasmas. On the linear physics, a variational formulation, based on the separation of singular and regular spatial scales, for drift-Alfvén instabilities excited by energetic particles is established. This variational formulation is then applied to derive the general fishbone-like dispersion relations corresponding to the various Alfvén eigenmodes and energetic-particle modes. It is further employed to explore in depth the low-frequency Alfvén eigenmodes and demonstrate the non-perturbative nature of the energetic particles. On the nonlinear physics, new novel findings are obtained on both the nonlinear wave-wave interactions and nonlinear wave-energetic particle interactions. It is demonstrated that both the energetic particles and the fine radial mode structures could qualitatively affect the nonlinear evolution of Alfvén eigenmodes. Meanwhile, a theoretical approach based on the Dyson equation is developed to treat self-consistently the nonlinear interactions between Alfvén waves and energetic particles, and is then applied to explain simulation results of energetic-particle modes. Relevant list of journal publications on the above findings is also included.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗