Search NASA⌕ Search

SEARCH · Search NASA

Results for “Load Monitoring”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Phasor-Measurement-Unit-Based Data Analytics Using Digital Twin and PhasorAnalytics Software

A major objective of this project was to apply GE’s commercial machine learning and data analytics toolsets to large-scale, real-world, anonymized Phasor Measurement Unit (PMU) datasets in order to extract signatures, correlated and/or causal factors, and precursor patterns associated with significant power system phenomena. The project had a particular emphasis on extraction of insights relevant to asset health monitoring, real-time load modeling and cybersecurity monitoring. Additionally, the team was directed to undertake a comprehensive data quality analysis for the provided datasets and encouraged to estimate the ‘machine-learning readiness’ of the datasets by documenting any major obstacles to the application of commercial machine learning algorithms. To accomplish the aforementioned objectives, the project team’s work centered around the identification of key event signatures and application of the identified event signatures for event detection and event classification. The industry-validated, semi-supervised machine learning strategy employed for event signature identification involved several major tasks, including data-preprocessing, generation of an overabundance of features, normal data identification, normality modeling, and event signature identification through a methodical, quantitative ranking of features in order of relevance to each studied event type. Throughout the project, data quality issues and mitigation techniques were investigated. In this report, insights are provided regarding the readiness of the provided synchrophasor datasets for application of machine learning and data analytics. The methodologies employed for this technical strategy are summarized in this report. With regards to data preprocessing and feature generation, the provided Training and Test Datasets were ingested into GE’s big data environment. Subsequently, the team applied bad data cleansing and data imputation scripts, event detection scripts, and application programming interfaces (APIs) to the datasets for convenient data access. The project team completed development and validation of dozens of physics-based, statistics-based and transformation-based feature functions used for the extraction of over 60 synchrophasor features. Using a new parallel feature generation technology developed on this project, over 60 features have been rapidly generated for the full two years’ worth of Training and Test Dataset data associated with both the Eastern and Western interconnects. Even accommodating for temporal down-sampling inherent to the feature extraction procedure, this parallel feature generation activity resulted in a massive feature set with a storage requirement approximately equal to that of the raw training dataset itself. With regards to normal data identification and normality modeling, a normality model was built using the feature data extracted from the Training Dataset and iteratively refined subsequent to incremental adjustments and expansions of the Training Dataset feature data. With respect to event characterization and signature identification, an event signature identification pipeline was developed and used in conjunction with the normality model to identify over 15 event signatures for key event categories within the Training Dataset. The identified event signatures were used to characterize hundreds of key events in terms of relative severity, duration, and location of the event. An investigation was undertaken to identify correlated and causal factors involved in transformer events. A separate investigation into temporal trends in ring-down analysis results was undertaken to determine possible associations between system dynamics and various other factors such as loading, season or year. To validate the identified event signatures, additional work was undertaken to develop signature-based anomaly detection and classification tools suitable for convenient application to the synchrophasor datasets. The anomaly detection and classification tools, suitable for online application, were then applied to the entirety of the Eastern Interconnect Training and Test Datasets. Performance of the event detection and classification tools was evaluated upon receipt of the Test Dataset event logs (i.e., the labels for events contained in the Test Dataset), and promising results were obtained despite several challenges (documented herein) associated with application of supervised or semi-supervised machine learning methods to large-scale, anonymized datasets. Finally, the detection and classification tools were used to detect, classify, and characterize thousands of new events not included in the original event logs provided by the DOE within both the Training and Test Datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a health monitoring framework: Application to a supercritical pulverized coal-fired boiler

In this study, this work details the development of a physics-based equipment health monitoring framework for a supercritical boiler, using first-principles models to estimate the remaining useful life (RUL) of its components. The framework accounts for fatigue and creep life consumption, generating spatio-temporal variations in mechanical and thermal stress. Analysis of the stress profile throughout the boiler highlights the finishing superheater inlet steam header as a vulnerable location susceptible to damage from cycling operation. The framework also yields quantified uncertainty in the RUL projection for specific locations, accounting for uncertainties in material properties and boiler operation. Results indicate that operational uncertainties (e.g., seasonal variation and operational strategy) and material properties (e.g., rupture time coefficients, Young’s modulus, yield strength, and coefficient of thermal expansion) significantly impact the RUL of the finishing superheater inlet steam header. Additionally, case studies demonstrate the use of the health monitoring framework as a predictive tool for operational planning under uncertainty, including scenarios with and without updates on the operation of the boiler.

20 FOSSIL-FUELED POWER PLANTS↗

Polymer-Stabilized Liquid Metal Nanoparticles as a Scalable Current Collector Engineering Approach Enabling Lithium Metal Anodes

Dendrites and dead lithium formation over prolonged cycling have long been challenges that hinder the safe implementation of metallic Li anodes. In this study, we employ polymer-stabilized liquid metal nanoparticles (LM-P NPs) of eutectic gallium indium (EGaIn) to create uniform Li nucleation sites enabling homogeneous lithium electrodeposition. Block copolymers of poly(ethylene oxide) and poly(acrylic acid) (PEO-b-PAA) were grafted onto the EGaIn surface, forming stabilized, well-dispersed NPs. Using a scalable spray coating approach, LM-P NPs were fabricated on copper current collectors, providing lithiophilic PEO sites and interactive carboxyl groups to guide Li deposition. The Li-EGaIn alloying process greatly reduced the Li + diffusion barrier, enabling fast Li transport through the coating layer, resulting in decreased nucleation overpotential. Therefore, about five times lower Li nucleation overpotential was obtained on the LM-P modified Cu with an optimal composition of the polymers than the bare Cu substrates. DFT computations was used to reveal the binding properties between the LM-P layer and Li. Due to the regulated Li plating/stripping process, as-obtained 30 μm Li anodes paired with LiNi 0.8 Co 0.1 Mn 0.1 O 2 (NCM8 11 ) with a negative/positive electrode capacity (N/P) ratio ~ 10 exhibited stable cycling performance at 0.5C for over 250 cycles, with an average Coulombic efficiency of 99.55%. Ultrathin Li (1 μm) anodes with an N/P ratio ~ 0.6 were also demonstrated in Li|LiFePO 4 cells, which examined the stabilization of Li by LM-P NPs and monitored practical loadings of Li anodes that are close to anode-free systems.

25 ENERGY STORAGE↗

Guest Editorial

This Special Issue entitled 'Performance Assessment and Condition Monitoring of Photovoltaic Systems for Improved Energy Yield', contains ten papers that discuss various aspects in performance assessment, thus bringing the reader up to date with the present state-of-the-art technologies. In particular, the following topics are addressed: system performance monitoring; operational analysis and design; solar forecasting.

14 SOLAR ENERGY↗

Implosion dynamics and radiation characteristics of wire-array Z pinches on the Cornell Beam Research Accelerator

Experimental results are presented that characterize the implosion dynamics and radiation output of wire-array Z pinches on the 1-MA, 100-ns rise-time Cornell Beam Research Accelerator (COBRA) [J. B. Greenly et al., Rev. Sci. Instrum. 79, 073501 (2008)]. The load geometries investigated include 20-mm-tall cylindrical arrays ranging from 4 to 16 mm in diameter, and consisting of 8, 16, or 32 wires of either tungsten, aluminum, or Invar (64% iron, 36% nickel). Diagnostics fielded include an optical streak camera, a time-gated extreme-ultraviolet framing camera, a laser shadowgraph system, time-integrated pinhole cameras, an x-ray wide-band focusing spectrograph with spatial resolution, an x-ray streak camera, a load voltage monitor, a Faraday cup, a bolometer, silicon diodes, and diamond photoconducting detectors. The data produced by the entire suite of diagnostics are analyzed and presented to provide a detailed picture of the overall implosion process and resulting radiation output on COBRA. The highest x-ray peak powers (300-500 GW) and total energy yields (6-10 kJ) were obtained using 4-mm-diameter arrays that stagnated before peak current. Additional findings include a decrease in soft x-ray radiation prior to stagnation as the initial wire spacing was changed from 1.6 mm to 785 {mu}m, and a timing correlation between the onset of energetic electrons, hard x-ray generation, and the arrival of trailing current on axis - a correlation that is likely due to the formation of micropinches. The details of these and other findings are presented and discussed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Tapered optical fibers as tools for probing magneto-optical trap characteristics

We present a novel technique for measuring the characteristics of a magneto-optical trap (MOT) for cold atoms by monitoring the spontaneous emission from trapped atoms coupled into the guided mode of a tapered optical nanofiber. We show that the nanofiber is highly sensitive to very small numbers of atoms close to its surface. The size and shape of the MOT, determined by translating the cold atom cloud across the tapered fiber, is in excellent agreement with measurements obtained using the conventional method of fluorescence imaging using a charge coupled device camera. The coupling of atomic fluorescence into the tapered fiber also allows us to monitor the loading and lifetime of the trap. The results are compared to those achieved by focusing the MOT fluorescence onto a photodiode and it was seen that the tapered fiber gives slightly longer loading and lifetime measurements due to the sensitivity of the fiber, even when very few atoms are present.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assembly of a Mechanical Model of MQXFB, the 7.2-m-Long Low-$\beta$ Quadrupole for the High-Luminosity LHC Upgrade

The ${\rm Nb_{3}Sn}$low-$\beta$quadrupole MQXF is being developed as a part of the High-Luminosity large hadron collider (LHC) upgrade project. The magnet will be produced in two different configurations, sharing the same cross section but with different lengths. A 7.2-m mechanical model of MQXFB was recently assembled at european organization for nuclear research (CERN) with one copper coil, two low-grade coils, and one rejected coil. Coil dimensions were measured with a portable coordinate measurement machine. The coil pack shimming was designed in order to optimize the field quality and the contacts between the coils and the collars. The azimuthal preload target was defined using the short models experience. The mechanical behavior during loading was monitored by means of strain gauges. The results demonstrated that the structure can provide the required prestress to the coils.

43 PARTICLE ACCELERATORS↗

A Contextually Supervised Optimization-Based HVAC Load Disaggregation Methodology

This paper presents a novel contextually supervised optimization-based approach for disaggregating heating, ventilation, and air-conditioning (HVAC) loads using smart meter or Supervisory Control and Data Acquisition data. To disaggregate the load into HVAC loads, large and infrequently used loads (LIUL), and base loads, we formulate an optimization problem to minimize a set of five loss terms, consisting of the reconstruction errors of the overall load profile, the ramp rate losses, and three distinct loss functions linked with the HVAC load, base load, and LIUL, respectively. To enhance accuracy, we incorporate two forms of contextual information into the problem formulation. First, we utilize mutual information to estimate HVAC energy consumption. Second, we employ a base load dictionary to constrain HVAC load estimation errors. The obtained HVAC load profiles are fine-tuned by abnormal ramp detection followed by binary hypothesis testing. Here, the proposed method is developed and tested using sub-metered residential and commercial building data. Simulation results show that the proposed method outperforms existing methods across various data resolutions and load aggregation levels, showing excellent transferability and generalizability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Phased: Phase-Aware Submodularity-Based Energy Disaggregation

Energy disaggregation is the task of discerning the energy consumption of individual appliances from aggregated measurements, which holds promise for understanding and reducing energy usage. In this paper, we propose PHASED, an optimization approach for energy disaggregation that has two key features: PHASED (i) exploits the structure of power distribution systems to make use of readily available measurements that are neglected by existing methods, and (ii) poses the problem as a minimization of a difference of sub-modular functions. We leverage this form by applying a discrete optimization variant of the majorization-minimization algorithm to iteratively minimize a sequence of global upper bounds of the cost function to obtain high-quality approximate solutions. PHASED improves the disaggregation accuracy of state-of-the-art models by up to 61% and achieves better prediction on heavy load appliances.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Flaming Moe

Current clamp measurements collected on various small electronic devices. Details on the data set can be found in J. M. Vann, T. P. Karnowski, R. Kerekes, C. D. Cooke and A. L. Anderson, A Dimensionally Aligned Signal Projection for Classification of Unintended Radiated Emissions, in IEEE Transactions on Electromagnetic Compatibility, vol. 60, no. 1, pp. 122-131, Feb. 2018, doi: 10.1109/TEMC.2017.2692962.

24 POWER TRANSMISSION AND DISTRIBUTION↗

TAS::89 0927::TAS RECOVERY - The Lean Green Energy Controller Machine

Achieving efficiency improvements and providing demand-response programs have been identified as key elements of our national energy initiative. The residential market is the largest, yet most difficult, segment to engage in efforts to meet these objectives. This project developed Energy Management System that engages the consumer and enables Smart Grid services, applications, and business processes to address this need. Our innovative solution provides smart controller providing dynamic optimization of energy consumption for the residential energy consumer. Our solution extends the technical platform to include a cloud based Internet of Things (IoT) aggregation of data sensors and actuators the go beyond energy management and extend to life style services provided through compelling mobile and console based user experiences.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

QXF Cold Mass Friction Test

The purpose of this test is to determine the longitudinal force on the stainless steel shell that is required to break the friction between the stainless steel shell and the aluminum shell underneath. This is achieved by suspending the short magnet between two backing plates on the eight grade 8 threaded rods which replace the 8 stainless steel toke tie rods in the magnet assembly. Eight hydraulic cylinders are mounted to each backing plate. Six, 22" sections of the stainless steel shell are welded in place on the magnet, each of which has a slightly different developed length, starting from the baseline design, and becoming progressively looser. A pushing flange is mounted to the stainless steel shells via small tack welds. Four load cells are then attached to the flange at designated points, while additional tooling is attached to each of the cylinders to facilitate the transfer of force from the cylinders to the stainless steel shell During the test, the cylinders will be slowly energized to no more than 7000 psi, with a resultant, longitudinal force on the flange of no more than 125,400 lbf. For each set of shells, the test ends when the load cell monitoring software detects a sharp decrease in force. This will indicate that the friction has broken. The cullenders will then be de-energized and the cycle will repeat for the next test. Welding operations outlined in the procedure (US-HiLumi-doc-4200) are outside the scope of the HA as the work is occurring under a previously-issued burn permit by qualified welders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate

Understanding indoor humidity conditions in low energy homes in hot-humid climates is critical to promoting long term occupant comfort, indoor air quality and building durability. The results of this study were expected to inform the residential building community on whether supplemental dehumidification is a needed and effective investment to promote these long term standards. Data logging equipment was installed at eight test homes in July, 2012 and later at two more test homes in January, 2013. Interior conditions and various end-use loads were monitored until November 7th, 2013. The mechanical systems at each of the 10 homes were commissioned by BSC to ensure consistent operation between each of the homes and to fully comply with the intended mechanical design. PHA-1 to 8 - Energy Savings: 21.8-18.9%, Company: Project Home Again (PHA); Address New Orleans, LA 70112, House Count: 8 BDC-1 - Energy Savings: 28.8%, Company: Broadmoor Development Corporation (BDC); Address New Orleans, LA 70112, House Count: 2

Array↗

Hybrid Ground-Source Heat Pump Installations: Experiences, Improvements and Tools

One innovation to ground-source heat pump (GSHP, or geothermal systems is the hybrid GSHP (HyGSHP) system. A HyGSHP system can dramatically decrease the first cost of GSHP systems by using conventional technology (such as a cooling tower or a boiler) to meet a portion of the peak heating or cooling load. We monitored and analyzed three buildings employing HyGSHP systems (two cooling-dominated, one heating-dominated) to demonstrate the performance of the hybrid approach. The buildings were monitored for a year and the measured data was used to validate models of each system. Additionally, we used the models to analyze further improvements to the hybrid approach and established that it has positive impacts, both economically and environmentally. We also documented the lessons learned by those who design and operate the three systems, including discussions of equipment sizing, pump operation, and cooling tower control. Finally, we described the measured data sets and models from this work and have made them freely available for further study of hybrid systems.

15 GEOTHERMAL ENERGY↗

Technology Solutions Case Study: Evaluation of the Performance of Houses With and Without Supplemental Dehumidification in a Hot-Humid Climate, New Orleans, Louisiana

The purpose of this project by Building Science Corporation was to evaluate the humidity control performance of new single family high performance homes, and compare the interior conditions and mechanical systems operation between two distinct groups of houses: homes with a supplemental dehumidifier installed in addition to HVAC system, and homes without any supplemental dehumidification. The subjects of the study were 10 single-family new construction homes in New Orleans, LA. Data logging equipment was installed at each home in 2012, and interior conditions and various end-use loads were monitored for one year. In terms of averages, the homes with dehumidifiers are limiting elevated levels of humidity in the living space; however, there was significant variation in humidity control between individual houses. An analysis of the equipment operation did not show a clear correlation between energy use and humidity levels. In general, no single explanatory variable appears to provide a consistent understanding of the humidity control in each house. Indoor humidity is likely due to all of the factors we have examined, and the specifics of how they are used by each occupant.

BSC↗

Disaggregating Smart Meter Data to Identify Electric Loads and Control Opportunities

As utility data, such as smart meter data, becomes more broadly available, there is general interest in using it to improve utility operations and enable adoption of other advanced technology - such as solar photovoltaics (PV), energy storage, and controls. We explore one such use case - identifying electric resistance water heaters from smart meter data, as well as characterizing their potential for load-shifting to support grid voltage stability under high-penetration PV adoption. This paper shows the limitation of typical 15-minute data, and how shortterm capture of additional 1-minute data is needed to enable the desired application. Results indicate about 4 kWh water heating load can be shifted to align with peak sun hours in a low use home. This methodology is an example, and can be adapted to other grid-integrated efficient building use cases.

14 SOLAR ENERGY↗

Prototype Development of Remote Operated Hot Uniaxial Press (ROHUP) to Fabricate Advanced Tc-99 Bearing Ceramic Waste Forms - 13381

The objective of this senior student project is to design and build a prototype construction of a machine that simultaneously provides the proper pressure and temperature parameters to sinter ceramic powders in-situ to create pellets of rather high densities of above 90% (theoretical). This ROHUP (Remote Operated Hot Uniaxial Press) device is designed specifically to fabricate advanced ceramic Tc-99 bearing waste forms and therefore radiological barriers have been included in the system. The HUP features electronic control and feedback systems to set and monitor pressure, load, and temperature parameters. This device operates wirelessly via portable computer using Bluetooth{sup R} technology. The HUP device is designed to fit in a standard atmosphere controlled glove box to further allow sintering under inert conditions (e.g. under Ar, He, N{sub 2}). This will further allow utilizing this HUP for other potential applications, including radioactive samples, novel ceramic waste forms, advanced oxide fuels, air-sensitive samples, metallic systems, advanced powder metallurgy, diffusion experiments and more. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

LEISURE: Load-Balanced Network-Wide Traffic Measurement and Monitor Placement

We report that network-wide traffic measurement is of interest to network operators to uncover global network behavior for the management tasks of traffic accounting, debugging or troubleshooting, security, and traffic engineering. Increasingly, sophisticated network measurement tasks such as anomaly detection and security forensic analysis are requiring in-depth fine-grained flow-level measurements. However, performing in-depth per-flow measurements (e.g., detailed payload analysis) is often an expensive process. Given the fast-changing Internet traffic landscape and large traffic volume, a single monitor is not capable of accomplishing the measurement tasks for all applications of interest due to its resource constraint. Moreover, uncovering global network behavior requires network-wide traffic measurements at multiple monitors across the network since traffic measured at any single monitor only provides a partial view and may not be sufficient or accurate. These factors call for coordinated measurements among multiple distributed monitors. In this paper, we present a centralized optimization framework, LEISURE (Load- EqualIzed meaSUREment), for load-balancing network measurement workloads across distributed monitors. Specifically, we consider various load-balancing problems under different objectives and study their extensions to support both fixed and flexible monitor deployment scenarios. We formulate the latter flexible monitor deployment case as an MILP (Mixed Integer Linear Programming) problem and propose several heuristic algorithms to approximate the optimal solution and reduce the computation complexity. We evaluate LEISURE via detailed simulations on Abilene and GEANT network traces to show that LEISURE can achieve much better load-balanced performance (e.g., 4.75 × smaller peak workload and 70 × smaller variance in workloads) across all coordinated monitors in comparison to a naive solution (uniform assignment) to accomplish network-wide traffic measurement tasks under the fixed monitor deployment scenario. Lastly, we also show that under the flexible monitor deployment setting, our heuristic solutions can achieve almost the same load-balancing performance as the optimal solution while reducing the computation times by a factor up to 22.5 × in Abilene and 800 × in GEANT.

42 ENGINEERING↗