Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long duration”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Inhibition of Micro-pitting by Tribofilm-Forming ZrO 2 Nanocrystal Lubricant Additives: A Micro-pitting Rig and Transmission Electron Microscope Study

The drive to reduce fuel consumption in transportation has encouraged the emergence of low viscosity lubricants to reduce viscous losses in the engine, drivetrain, and other components. However, viscosity reduction increases the risk of surface damage, thus motivating the development of new anti-wear (AW) additives. Capped ZrO 2 nanocrystals (NCs) in base oils have been shown to form AW tribofilms within microscale sliding contacts. However, the potential of ZrO 2 NCs to protect surfaces subjected to rolling-sliding contact from macroscale damage, such as micro-pitting, remains unexplored. Here, we explore the ability of ZrO 2 NCs to form protective tribofilms under harsh conditions using a micro-pitting rig (MPR), consisting of a three ring-on-roller configuration. The experiments were conducted in polyalphaolephin (PAO) base oil, with and without 5 nm diameter ZrO 2 NCs, at two levels of slide-to-roll ratio (SRR) (30% and 0%) and at variable test durations up to long durations (119 h). MPR results showed the use of ZrO 2 NCs gives rise to the formation of a tribofilm covering the roller surfaces and decreases the initiation and propagation of micro-pits compared to tests in pure PAO base stock. Transmission electron microscopy (TEM) performed on focused ion beam (FIB) milled cross-sectional samples of the roller surfaces revealed the growth of dense and 50–100 nm thick ZrO 2 -based tribofilms independent of (SRR), indicating the potential for robust micro-pitting fatigue protection. Nevertheless, small cracks localized within the near surface region of the roller tested at the most severe conditions (30% SRR and 119 h) were observed. The initiation of these cracks was directly related to the presence of manganese sulphide (MnS) inclusions in the steel, revealed using TEM combined with energy dispersive spectroscopy (EDS). Furthermore, the results highlight the benefits of the protective tribofilms formed by ZrO 2 NCs and suggest approaches for further optimizing their use.

36 MATERIALS SCIENCE↗

Pumped-Thermal Electricity Storage Based on Brayton Cycles

Pumped-thermal electricity storage (PTES) based on a reversible (Joule-)Brayton cycle is a promising grid-scale energy storage technology, whose working principle is to store electricity in the form of high-grade thermal energy. This chapter provides an overview of the inner workings, operating principle and current development status of the many PTES variants, as proposed to date in the scientific literature or by manufacturers. The potential and competitiveness of the various candidate designs is quantified by - and discussed thanks to the definition of - specific techno-economic indicators. Investment cost and thermodynamic performance estimates are reported and used to assess the value of this technology as a potential large-scale, long-duration and long-lifetime energy storage option with unique sector-coupling features and low geographical constraints.

electricity storage↗

Amplified Extreme Floods and Shifting Flood Mechanisms in the Delaware River Basin in Future Climates

Abstract Historical records in the Delaware River Basin reveal complex and spatially diverse flood generating mechanisms influenced by the region's mountains‐to‐plains gradients. This study focuses on predicting future flood hazards and understanding the underlying drivers of changes across the region. Using a process‐based hydrological model, we analyzed the hydrometeorological condition of each historical and future flood event. For each event, at the subbasin scale, we identified the dominant flood generating mechanism, including snowmelt, rain‐on‐snow, short‐duration rain, and long‐duration rain. The rain‐induced floods are further categorized based on the soil's Antecedent Moisture Condition (AMC) before the event, whether dry, normal, or wet. Our historical analysis suggests that rain‐on‐snow is the primary flood mechanism of the Upper Basin. Although most frequent, the magnitude of rain‐on‐snow floods is often less severe than short rain floods. In contrast, historical floods in the Lower Basin are primarily caused by short rain under normal AMC. Given the uncertainties in climate projections, we used an ensemble of future climate scenarios for flood projections. Despite variations in regional climate projections, coherent perspectives emerge: the region will shift toward a warmer, wetter climate, with a projected intensification of extreme floods. The Upper Basin is projected to experience a marked decrease in rain‐on‐snow floods, but a substantial increase in short rain floods with wet AMC. The largest increase in flood magnitude will be driven by short rains with wet AMC in the Upper Basin and by short rains with normal AMC in the Lower Basin.

54 ENVIRONMENTAL SCIENCES↗

Technology Strategy Assessment: Findings from Storage Innovations 2030 Lithium-ion Batteries

This report on accelerating the future of lithium-ion batteries is released as part of the Storage Innovations (SI) 2030 strategic initiative. The objective of SI 2030 is to develop specific and quantifiable research, development, and deployment (RD&D) pathways toward achieving the targets identified in the Long-Duration Storage Energy Earthshot, which seeks to achieve 90% cost reductions for technologies that can provide 10 hours or longer of energy storage within the coming decade. Through SI 2030, the U.S. Department of Energy (DOE) is aiming to understand, analyze, and enable the innovations required to unlock the potential for long-duration applications in the following technologies.

25 ENERGY STORAGE↗

Comparative techno-economic analysis of synthetic renewable natural gas production via reactive CO 2 capture and conversion

Reactive CO 2 capture and conversion (RCC) is an emerging carbon management strategy that integrates CO 2 capture and conversion and avoids intermediate CO 2 purification. In this study, we design an RCC process to capture atmospheric CO 2 and react it with renewable hydrogen to produce synthetic renewable natural gas (SRNG), which serves as a carbon-neutral energy source and a chemical form of long-duration renewable energy storage. We assess the technological potential of RCC through process modeling, techno-economic, carbon footprint, and sensitivity analyses. Our findings demonstrate that RCC offers energy savings and comparable cost to separated capture and conversion processes. The cost is dominated by renewable hydrogen and material replacement cost. SRNG produced via RCC is competitive with existing low-carbon natural gas technologies and presents a promising low-cost option for long-duration energy storage. This work highlights the potential for deploying RCC technologies within a circular carbon economy and the scientific and technical challenges that must be overcome for material and technology developers.

03 NATURAL GAS↗

Technoeconomic Analysis of Discrete and Unitized Reversible Fuel Cells for Energy Storage Applications

Reversible Fuel Cell (RFC) systems offer promising characteristics for stationary long duration energy storage applications. Two main configurations of RFC systems exist: discrete RFC systems and unitized RFC systems. While discrete RFC systems combine independent fuel cell and electrolyzer systems for energy storage, unitized RFC systems utilize a single electrochemical stack and might share balance of plant (BOP) components for both charging and discharging processes. While this configuration reduces upfront capital costs, challenges of unitized RFC designs include potential performance trade-offs due to dual-mode stack design and operational complexities across varying loads and operating conditions. Furthermore, these tradeoffs might be different for low-temperature PEM RFCs than for high-temperature reversible solid oxide cell systems. The goal of this project is to assess unitized RFC system potential in the context of long duration grid energy storage and HFTO's technical targets for different discrete fuel cell and electrolyzer technologies. This presentation presents preliminary review of state-of-the-art unitized RFC cells and assesses how they perform relative to HFTO's technical targets. It also presents literature-derived system configurations worth investigating. This review indicates that lab-scale unitized RFCs are making good progress towards meeting HFTO's technical targets.

HYDROGEN↗

Advancing Pumped Thermal Energy Storage Performance and Cost Using Silica Storage Media

Pumped Thermal Energy Storage (PTES) is an electricity storage system that is suitable for long-duration energy storage (10-1000 h) due to its low marginal cost of energy capacity. We present a techno-economic model of a PTES system that uses particle thermal energy storage. Particles have low costs and can be operated over a wide temperature range leading to increased efficiency and reduced costs compared to other PTES designs. We show how the round-trip efficiency, specific power output, capital cost, and levelized cost of storage (LCOS) depend on parameters such as the pressure ratio, heat exchanger approach temperature and pressure loss, and maximum temperature. We compare particle-PTES (P-PTES) performance to PTES which uses liquid thermal energy storage - i.e. molten salt hot storage and methanol cold storage (MS-PTES). We find that using silica particles for storage advances PTES technology: P-PTES can be operated at higher maximum temperatures than MS-PTES. Furthermore, P-PTES can achieve lower approach temperatures in the heat exchangers than MS-PTES without increasing capital costs, because P-PTES uses direct-contact heat transfer in fluidized bed heat exchangers. As a result, we find that P-PTES systems achieve higher round-trip efficiency than MS-PTES (66 % versus 57 %) and lower LCOS (e.g. 0.115 +- 0.03 $/kWhe versus 0.171 +- 0.04 $/kWhe for 10 h discharge). The low cost of particles and containment means that P-PTES can provide long-duration energy storage at low capital cost per unit energy capacity. For example, the total capital cost per unit energy reduces from 245 $/kWhe at 10 h to 38 $/kWhe at 100 h. These costs are considerably lower than MS-PTES (72 $/kWhe at 100 h) and also outcompete current and future Li-ion battery system projections (100-265 $/kWhe).

25 ENERGY STORAGE↗

Guidance for Monitoring Passive Groundwater Remedies Over Extended Time Scales

Passive remediation can be appropriate where natural processes and actions such as institutional controls mitigate exposure to contaminated groundwater, achieving remedial action objectives and protectiveness of human health and the environment. Monitored natural attenuation (MNA) is a prevalent passive remediation strategy supported by a regulatory framework and monitoring design guidance. MNA can also be used after active remediation has been completed (e.g., pump-and-treat) as a polishing step to reach ultimate remedial action objectives. However, MNA and existing monitoring guidance primarily target situations where the remedial action objectives are met within a few decades. When timescales for passive remediation extend to many decades, a corresponding change in monitoring strategy is needed to adapt to the extended time scale. This document provides guidance for implementing an extended-scale monitoring (ESM) approach appropriate for long-duration passive remediation. Extended-scale is defined in this document with respect to time (i.e., a long duration of remediation) and a large enough physical scale such that receptors will not be impacted within the remediation timeframe.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Oil Filled Flow Shield Performance Evaluation

When hydrophones are used to monitor underwater sound in areas with currents, like rivers or tidal channels, flow noise caused by turbulent flow past a hydrophone can mask low frequency acoustic signals of interest. Flow shields can reduce the impacts of flow noise on hydrophone data. A prior study conducted by PNNL compared three flow shield designs and determined that an oil-filled urethane shield performed better than other designs and was likely sufficiently robust for long-duration marine deployments. However, that study did not assess the high frequency performance of the oil-filled flow shield or conduct long-duration field testing. Further, the prototype flow shield was difficult to assemble. This report details the results of design refinement and testing to address these gaps. Design refinements resulted in a straightforward and repeatable assembly method. Field testing indicated that the flow shields reduce flow noise by over 20 dB below 50 Hz at flow speeds greater than 0.5 m/s and are proven to survive deployments more than 6 months long. Calibration of the same hydrophone with and without a flow shield installed indicated that the shields attenuate propagating sound by no more than 2 dB at frequencies below 30 kHz.

42 ENGINEERING↗

Seasonal Performance Characterization of a Gen3 Particle-Based Concentrating Solar Plant With a Spatially Resolved Transient Thermal Storage Model

Particle-based Gen3 Concentrating Solar Power (CSP) can be paired with high-temperature power cycles (>700 °C) and can have built-in long duration (≥10 hours) thermal energy storage if the working particles are stored properly in thermal energy storage bins. Although high-temperature and long-duration thermal energy storage can mitigate daily intermittencies in solar irradiation, seasonal variability in local meteorological conditions can still have a significant impact on the overall performance of CSP systems. Aside from daily cloud coverage affecting incident solar radiation, wind speed and ambient temperature are also significant variables regarding system heat attenuation, component efficiency, and overall solar conversion efficiency. In this work, we present simulation results for a Gen3 CSP prototype system in operation over four weeks throughout the year in Albuquerque, NM. The meteorological conditions are taken directly from the TMY3 data at the Albuquerque International Sunport, where the hourly Direct Normal Irradiation (DNI), wind speed, and ambient temperature are of particular interest. An investigation of the sensitivity of individual components like storage and ducting to the local meteorological conditions is provided and extended to the overall performance of the CSP system. The results from this study show that the particle inlet temperature at the particle-to-sCO2 heat exchanger can change as fast as 30 °C/min under standard operation in a passive mode.

Plewe, Kaden (ORCID:0000000286826879)↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Particle-based thermal energy storage systems

Methods and devices for long-duration electricity storage using low-cost thermal energy storage and high-efficiency power cycle, are disclosed. In some embodiments it has the potential for superior long-duration, low-cost energy storage.

Ma, Zhiwen↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Equivalence Ratio Scans in a Rotating Detonation Engine

Published data for run times exceeding a few seconds in rotating detonation engines (RDEs) is rare, but long duration tests are necessary to understand both transient and persistent phenomena in RDE operation. Previous work has noted different detonation wave modes at different equivalence ratios. In the current study, multiple long-duration runs with constant air flow rate and variable equivalence ratio are conducted in a hydrogen-fueled, water-cooled RDE. Analysis of the capillary tube averaged pressure (CTAP) data reveals a strong correlation with equivalence ratio as well as a small time dependency due to transient thermal processes. Ion probe measurements are used to analyze detonation wave frequencies and modes, both of which are strongly dependent on the equivalence ratio. Mode transitions are observed to occur consistently as the equivalence ratio is traversed between 0.55 and 0.60. These transitions are also found to be a function of the direction of changing equivalence ratio (ascending or descending) and time.

Boyette, Wesley R.↗

Can a Coating Mitigate Molten Na Dendrite Growth in NaSICON Under High Current Density?

Alkali metals are among the most desirable negative electrodes for long duration energy storage due to their extremely high capacities. Currently, only high-temperature (>250 °C) batteries have successfully used alkali electrodes in commercial applications, due to limitations imposed by solid electrolytes, such as low conductivity at moderate temperatures and susceptibility to dendrites. Toward enabling the next generation of grid-scale, long duration batteries, we aim to develop molten sodium (Na) systems that operate with commercially attractive performance metrics including high current density (>100 mA cm –2 ), low temperature (<200 °C), and long discharge times (>12 h). In this work, we focus on the performance of NaSICON solid electrolytes in sodium symmetric cells at 110 °C. Specifically, we use a tin (Sn) coating on NaSICON to reduce interfacial resistance by a factor of 10, enabling molten Na symmetric cell operation with “discharge” durations up to 23 h at 100 mA cm –2 and 110 °C. Unidirectional galvanostatic testing shows a 70% overpotential reduction, and electrochemical impedance spectroscopy (EIS) highlights the reduction in interfacial resistance due to the Sn coating. Detailed scanning electron microscopy (SEM) and energy-dispersive spectroscopy (EDS) show that Sn-coated NaSICON enables current densities of up to 500 mA cm –2 at 110 °C by suppressing dendrite formation at the plating interface (Mode I). In conclusion, this analysis also provides a mechanistic understanding of dendrite formation at current densities up to 1000 mA cm –2 , highlighting the importance of effective coatings that will enable advanced battery technologies for long-term energy storage.

25 ENERGY STORAGE↗

Calibration of CDM-Based Creep Constitutive Model Using Accelerated Creep Test (ACT) Data

In conventional creep testing (CCT) a specimen is subject to constant load and temperature for a long-duration until creep rupture occurs. Conventional testing can be costly when considering the number of experiments needed to characterize the creep response of a material over a range of stress and temperature. To predict long-term creep-rupture properties, the time-temperature-stress superposition principle (TTSSP) approach has been employed where stress and/or temperature is applied at an elevated level; the result of which are extrapolated down to low stress and/or temperature conditions. These methods have been successful in predicting minimum-creep-strain-rate (MCSR) and stress-rupture (SR) but suffer from an inability to predict the creep deformation curve or account for changes in deformation mechanisms or aging that occurs at long-duration. An accelerated technique, termed the Stepped isostress method (SSM) allows the accelerated testing of materials to determine their creep deformation response. Unlike TTSSP tests, the SSM test employs a single specimen where the stress is periodically step increased until rupture. The SSM creep deformation curve is processed (time and strain shifted) to produce an accelerated creep deformation curve that represent the creep deformation curve at the initial stress level in SSM. A processing procedure for metals has yet to be developed. The research objective of this study is to develop a processing procedure for SSM test data using a creep-damage constitutive model. Triplicate SSM tests were conducted on Ni-based superalloy Inconel 718 at 650°C with stress being periodically increased until rupture. Triplicate CCT tests were conducted at the initial stress level of the SSM tests. The Sine-hyperbolic (Sinh) creep-damage model was employed in this study. The Sinh creep-damage constitutive model is based on coupled creep strain rate and damage evolution equations; where both rates are dependent on the current state of damage. Calibration is two-step: analytical and numerical optimization. Each stepped creep deformation curve is tackled quasi-analytically to determine MCSR and SR related material constants and accumulated damage. The damage accumulated at the end of each step was then passed onto subsequent steps to calibrate the MCSR, rupture prediction, and damage evolution. Numerical optimization was applied to optimize model constants involved in the creep strain constitutive equations in order to generate best-fitted Sinh creep deformation curves. The Sinh model predictions were compared to the SSM and CCT data. The Sinh model satisfactorily predicts the SSM data and thus the calibrated material constants provides a good estimate of rupture found in the CCT data. Calibration using SSM data reduces the number of tests needed to calibrate a model; significantly reducing costs. A single SSM test replaces numerous creep tests at different stresses.

36 MATERIALS SCIENCE↗

Advanced Oxygen-Free Electrolyzer for Ultra-Low-Cost H 2 Storage for Fossil Plants (Final Technical Report)

DOE’s Office of Fossil Energy and Carbon Management has determined that long-duration energy storage solutions co-located with fossil energy assets offer significant benefits to the fossil industry, electric utilities, and customers. T2M Global has developed an Advanced O 2 -Free Electrolyzer System (AES) Technology for low-cost, long-duration H 2 energy storage for fossil plants. The MW-class AES Module conceptual design aims to upgrade stranded assets (dilute/waste syngas streams, excess electricity, and waste heat) at fossil plants to higher value H 2 for additional revenue and greater sustainability. The H 2 energy storage equips fossil plants with the load following capability needed for the lucrative grid-support services market created by Variable Renewable Energy resources.

08 HYDROGEN↗

Integration of Pumped Heat Energy Storage with Fossil-Fired Power Plant (Final Report)

The project team of Southwest Research Institute ® (SwRI ® ), Malta Inc. (Malta), and Luminant Generation Company LLC (Luminant) completed a feasibility study for the integration of a 100-MW, 10-hour (1000-MWh) Malta Pumped Heat Energy Storage (MPHES) system with multiple full-sized fossil-fired electricity generation units (EGU) in Luminant portfolio. MPHES is a long-duration, molten-salt-energy storage technology that uses turbomachinery and heat exchangers to transfer energy to a thermal storage media when charging, and removes the heat in a similar fashion when discharging. With high round trip efficiency (60-65%) and long lifespan (30+ years), MPHES provides economic benefits to the fossil-asset owners that can be scaled to integrate with assets across their portfolio. This technology uses hardware components, workforce personnel, and skillsets similar to those used by fossil EGUs, allowing for synergy when co-locating the two technologies. Luminant has approximately 39,000 megawatts of generation across 12 states, operating in six of the seven competitive markets in the U.S. and powered by a diverse portfolio of natural gas, nuclear, coal, and solar facilities. The DeCordova plant in Granbury, Texas, a simple cycle natural gas peaker power plant, was used as the fossil-fired asset in this project. The local market in Granbury, Texas has many influences, including several nearby power plants, a Luminant-owned nuclear plant (Comanche Peak), and substantial wind energy, which causes both negative pricing at night and high market volatility. Reducing false starts of the DeCordova plant and better responding to market volatility would be an economic advantage. Luminant is currently integrating battery storage plant on site to begin addressing these challenges. Integrating long-duration storage, like MPHES, would expand this capability beyond one hour of storage and have the potential to greatly reduce the total number of gas turbine starts. The MPHES charging requirement could help offset the overnight operating costs of Comanche Peak, which cannot load follow, and the nearby Luminant-owned Wise County combined cycle plant that cycles too often. Following the assessment of Luminant’s ERCOT-based portfolio for integration compatibility with Malta’s PHES system and the project tasks of conceptual study, technoeconomic analysis, technology gap assessment, and commercialization plan, the project team effort has resulted in several key outcomes: (1) Identification of market trends in a high-wind penetration market outside a major metropolitan area; (2) Creation of a dispatching model for the MPHES system and the pairing of Li-ion battery with a gas turbine in a real time market; (3) Revenue and cost estimations for operating MPHES alongside a gas peaker plant with real dispatching considerations and comparison with variations in the Malta implementation, including doubling the storage capacity and using two discharge drivetrains; (4) Potential carbon emission reductions possible by replacing gas turbine operation with Malta PHES operation; and (5) Summary of literature-based future market predictions for Texas.

20 FOSSIL-FUELED POWER PLANTS↗