Search NASA⌕ Search

SEARCH · Search NASA

Results for “Long-wavelength Infrared”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

1.25-mm observations of luminous infrared galaxies

Measurements at a wavelength of 1.25 mm have been obtained for 17 IRAS galaxies selected on the basis of high far-infrared luminosity. These measurements are used to estimate the lower and upper limits to the mass of cold dust in infrared galaxies. As a lower limit on dust mass, all of the galaxies can be successfully modeled without invoking any dust colder than the dust responsible for the 60 and 100 micron emission that was detected by IRAS. As an upper limit, it is possible that the dust mass in a number of the galaxies may actually be dominated by cold dust. This large difference between the lower and upper limits is due primarily to uncertainty in the long-wavelength absorption efficiency of the astrophysical dust grains.

Carico, David P.↗

The anomalous thermal properties of glasses at low temperatures

While experimentally there is great regularity below 1 deg K in the behavior of a particular thermal property for all amorphous dielectrics it is not understood why these properties should differ from those of crystalline dielectrics, since it would seem that at low temperatures long-wavelength elastic waves, similar in both cases, would determine the thermal properties. A model involving systems having very few levels is used in the present study, although the relation between the model's systems and the nature of the glassy state is not known. It is shown, among other effects, that: specific heat measurements above 0.1 K indicate a distribution of local modes independent of energy; ultrasonic velocity measurements give information about phonon-local mode coupling parameters; and thermal expansion and far infrared experiments indicate a phonon-assisted tunneling model.

Pohl, R. O.↗

Astronomical observations of phenomena in disks

Astronomical constraints on disks around young stellar objects are reviewed in this abstract. Since disks around the youngest stars cannot generally be resolved spatially, most results are based on analyses of the infrared and radio emission from circumstellar dust and gas. At least half of all young stars seem to have substantial circumstellar disks at an age of approximately 10(exp 6) yr. The young objects without disks tend to be binary stellar systems, though not exclusively, and some close binaries may have outer disks that are not tidally disrupted. Probably most, if not all, stars formed originally with circumstellar disks, but evolutionary timescales may differ dramatically. All the results, disk disappearance, disk mass around young stars, and long-wavelength dust opacities, are subject to the additional uncertainty of the effects of infalling dusty envelopes, which produce the disks in the first place.

Hartmann, L.↗

Titan Haze

The Titan haze exerts a dominating influence on surface visibility and atmospheric radiative heating at optical and near-infrared wavelengths and our desire to understand surface composition and atmospheric dynamics provides a strong motivation to study the properties of the haze. Prior to the Cassini/Huygens missions the haze was known to be global in extent, with a hemispheric contrast asymmetry, with a complicated structure in the polar vortex region poleward of about 55 deg latitude, and with a distinct layer near 370 km altitude outside of the polar vortex at the time of the Voyager 2 flyby. The haze particles measured by the Pioneer and Voyager spacecraft were both highly polarizing and strongly forward scattering, a combination that seems to require an aggregation of small (several tens of nm radius) primary particles. These same properties were seen in the Cassini orbiter and Huygens Probe data. The most extensive set of optical measurements were made inside the atmosphere by the Descent Imager/Spectral Radiometer (DISR) instrument on the Huygens Probe. At the probe location as determined by the DISR measurements the average haze particle contained about 3000 primary particles whose radius is about 40 nm. Three distinct vertical regions were seen in the DISR data with differing particle properties. Refractive indices of the particles in the main haze layer resemble those reported by Khare et al. between O.3S and about 0.7 micron but are more absorbing than the Khare et al. results between 0.7 micron and the long-wavelength limit of the DISR spectra at 1.6 micron. These and other results are described by Tomasko et al., and a broader summary of results was given by Tomasko and West,. New data continue to stream in from the Cassini spacecraft. New data analyses and new laboratory and model results continue to move the field forward. Titan's 'detached' haze layer suffered a dramatic drop in altitude near equinox in 2009 with implications for the circulation and seasonal change in the stratosphere. The book chapter associated with this talk will also present new material on thermal-infrared data analysis and on new developments in laboratory work and haze microphysical modeling.

Anderson, Carrie M.↗

Spectral irradiance calibration in the infrared. II - Alpha Tau and the recalibration of the IRAS low resolution spectrometer

A general process for creating complete, continuous, and absolutely calibrated 1-35 micron stellar spectra is described. The method is demonstrated by constructing an absolutely calibrated 1-35 micron spectrum of Alpha Tau and the method is independently validated using new observations. The absolute calibration of the IRAS low resolution spectrometer (LRS) data base is investigated by comparing the observed spectrum of Alpha Tau with that assumed in the original LRS calibration scheme. An analysis of asteroidal LRS spectra results in an independent assessment of the calibration problems with the LRS and provides a natural complement to the effort based on Alpha Tau. A direct comparison of LRS stellar spectra with independently calibrated long-wavelength airborne and ground-based spectra is made.

Cohen, Martin↗

Infrared observations of Nova Cygni 1975

Infrared photometry from 1 to 20 microns and spectroscopy at about 2 microns are presented for Nova Cygni 1975 for the period from 2 days before to 1 yr after maximum light. The data can be explained by a simple model in which the expanding gas expelled during the explosion is always a plasma at approximately 10,000 K. Initially the gas is optically thick; this phase clearly defines the time of onset of the nova. Later, as the gas continues to expand, it becomes optically thin. The temporal dependence of the observed flux suggests that in this phase the expanding cloud is in the form of a shell. After about 300 days, long-wavelength emission which may be attributable to thermal reradiation from dust is observed.

Ennis, D.↗

Fundamental Studies of the Vibrational, Electronic, and Photophysical Properties of Tetrapyrrolic Architectures

The ability to capture and utilize light in the near-ultraviolet (NUV), visible and near-infrared (NIR-I and NIR-II) spectral regions (i.e., 320–400, 400–700, 700–1000, 1000–1700 nm) is essential for any solar-energy conversion scheme. Nature employs chlorophylls and bacteriochlorophylls in light-harvesting architectures to absorb light in the blue and red/NIR regions. Accessory pigments (carotenoids, bilins) augment absorption of the (bacterio)chlorophylls in the green region. The harvested energy is funneled to a reaction center protein, where charge separation occurs. Subsequent migration of the electron and the hole stabilizes and stores the energy from light via redox chemistry. The long-term objective of the Bocian/Holten&Kirmaier/Lindsey research program under this DOE grant has been to develop tetrapyrrole-based molecular architectures that absorb sunlight, funnel energy and separate charge with high efficiency. Integral to the program has been iterative cycles of design, synthesis and characterization that provided deep insights into the relationships between chemical composition, electronic structure, and key static and dynamic properties (vibrational, redox, photophysical, energy/charge transfer) of tetrapyrrolic systems. Such architectures included monomers, dyads, larger arrays, and complexes with accessory components. The objective was to develop molecular designs and guiding principles to enhance current and future energy-conversion schemes. Molecular arrays targeted to address one or more fundamental questions concerning light harvesting and energy/charge transfer were constructed from analogues of the naturally occurring hemes, chlorophylls and bacteriochlorophylls. Diverse, tunable synthetic building blocks were prepared that spanned the three respective tetrapyrrole families, which are the porphyrins, chlorins and bacteriochlorins. Thus, the research focused on porphyrins as well as synthetic surrogates for chlorophylls (chlorins, 13 1 -oxophorbines and chlorin-imides) and bacteriochlorophylls (bacteriochlorins, bacterio-13 1 -oxophorbines and bacteriochlorin-imides), generically termed hydroporphyrins. Although the three tetrapyrrole classes (porphyrins, chlorins and bacteriochlorins) absorb light strongly in the violet-blue spectral region, the long-wavelength absorption band typically lies in the green-orange, red, and NIR regions, respectively, with increasing intensity. Understanding the spectra, electronic structure, and energy/charge-transfer properties of such tetrapyrrolic macrocycles is of central importance for the rational design of molecular architectures for solar-energy conversion. Our integrated program of molecular design and synthesis coupled with a variety of spectroscopic, electrochemical, and computational studies have probed from first principles how structural and electronic properties of tetrapyrrolic macrocycles dictate spectral properties as well as the rates of ground-state hole/electron transfer and excited-state energy flow in multicomponent architectures. Individual molecules and multicomponent architectures were designed to test ideas of fundamental importance, often requiring the development of new synthetic methodology. The members of the collaborative team had almost daily discussions by phone and/or e-mail concerning design of molecules, flow of compounds between the labs, planning of physical characterization studies, discussing results and analysis and integrating into design of next generation architectures, and the preparation of manuscripts. Furthermore, students and postdocs in the different labs routinely communicated with one another to facilitate the advancement of the research activities. In short, a highly integrated and collaborative research program was well established among the groups. The research effort involved molecular design and synthesis of synthetic molecular architectures by the Lindsey group integrated with physicochemical and photophysical characterization by the Bocian group and the Holten&Kirmaier group (Figure 2). The Bocian group carried out electrochemical, electron paramagnetic resonance (EPR), resonance Raman (RR), and Fourier-transform infrared (FT-IR) studies, as well as density functional theory (DFT) calculations and the time-dependent extension (TDDFT) to gain insight into excited-state properties. The Holten&Kirmaier group carried out static and time-resolved absorption and fluorescence spectroscopy studies and simulated absorption spectra using molecular orbital (MO) energies from DFT as input to the four-orbital model to complement the TDDFT calculations. The combined measurements provided understanding of the vibrational/electronic properties of the individual molecules and the changes that occur upon incorporation into multicomponent architectures. This information underpinned elucidating the mechanisms and timescales of ground-state hole/electron transfer and excited-state energy and charge transfer.

14 SOLAR ENERGY↗

The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR): A High Speed, Multispectral, Thermal Instrument Development in Support of HyspIRI-TIR

The Prototype HyspIRI Thermal Infrared Radiometer (PHyTIR) is being developed as part of the risk reduction activities associated with the Hyperspectral Infrared Imager (HyspIRI). The HyspIRI mission was recommended by the National Research Council Decadal Survey and includes a visible shortwave infrared (SWIR) pushboom spectrometer and a multispectral whiskbroom thermal infrared (TIR) imager. Data from the HyspIRI mission will be used to address key science questions related to the Solid Earth and Carbon Cycle and Ecosystems focus areas of the NASA Science Mission Directorate. The HyspIRI TIR system will have 60m ground resolution, better than 200mK noise equivalent delta temperature (NEDT), 0.5C absolute temperature resolution with a 5-day repeat from LEO orbit. PHyTIR addresses the technology readiness level (TRL) of certain key subsystems of the TIR imager, primarily the detector assembly and scanning mechanism. PHyTIR will use Mercury Cadmium Telluride (MCT) technology at the focal plane and operate in time delay integration mode. A custom read out integrated circuit (ROIC) will provide the high speed readout hence allowing the high data rates needed for the 5 day repeat. PHyTIR will also demonstrate a newly developed interferometeric metrology system. This system will provide an absolute measurement of the scanning mirror to an order of magnitude better than conventional optical encoders. This will minimize the reliance on ground control points hence minimizing post-processing (e.g. geo-rectification computations).

National Research Council Decadal Survey↗

Broadband THz Modulation via Solid–State Organic Electrochemical Devices

The sub-Terahertz and Terahertz bands play a critical role in next-generation wireless communication and sensing technologies, thanks to the large amount of available bandwidth in this spectral regime. While long-wavelength (microwave to mm-Wave) and short-wavelength (near-infrared to ultraviolet) devices are well-established and studied, the sub-THz to THz regime remains relatively underexplored and underutilized. Traditional approaches used in the aforementioned spectral regions are more difficult to replicate in the THz band, leading to the need for the development of novel devices and structures that can manipulate THz radiation effectively. Herein a novel organic, solid-state electrochemical device is presented, capable of achieving modulation depths of over 90% from ≈500 nm of a conducting polymer that switches conductivity over a large dynamic range upon application of an electronically controllable external bias. The stability of such devices under long-term, repeated voltage switching, as well as continuous biasing at a single voltage, is also explored. Switching stabilities and long-term bias stabilities are achieved over two days for both use cases. Additionally, both depletion mode (always “ON”) and accumulation mode (always “OFF”) operation are demonstrated. These results suggest applications of organic electrochemical THz modulators in large area and flexible implementations.

36 MATERIALS SCIENCE↗

Mid-infrared photodetection with 2D metal halide perovskites at ambient temperature

The detection of mid-infrared (MIR) light is technologically important for applications such as night vision, imaging, sensing, and thermal metrology. Traditional MIR photodetectors either require cryogenic cooling or have sophisticated device structures involving complex nanofabrication. Here, we conceive spectrally tunable MIR detection by using two-dimensional metal halide perovskites (2D-MHPs) as the critical building block. Leveraging the ultralow cross-plane thermal conductivity and strong temperature-dependent excitonic resonances of 2D-MHPs, we demonstrate ambient-temperature, all-optical detection of MIR light with sensitivity down to 1 nanowatt per square micrometer, using plastic substrates. Through the adoption of membrane-based structures and a photonic enhancement strategy unique to our all-optical detection modality, we further improved the sensitivity to sub–10 picowatt-per-square-micrometer levels. The detection covers the mid-wave infrared regime from 2 to 4.5 micrometers and extends to the long-wave infrared wavelength at 10.6 micrometers, with wavelength-independent sensitivity response. Our work opens a pathway to alternative types of solution-processable, long-wavelength thermal detectors for molecular sensing, environmental monitoring, and thermal imaging.

Li, Yanyan [Yale University, New Haven, CT (United↗

Titan - Unidentified strong absorptions in the photometric infrared

The morphology of Titan's infrared spectral features reveals a pattern of differences with respect to Saturn's bands. Titan's bands exhibit a progressive washing out with increasing wavelength relative to the corresponding bands in Saturn's spectrum. Unidentified absorption features of apparently gaseous origin appear in the long-wavelength wing of Titan's 1-micron CH4 band complex with considerably greater strength. Greater absorption is also observed in the 1.1 micron region. Not all of the phenomena can be explained by enhanced CH4 absorption, so Titan's spectrum implies the existence of another spectroscopically active gas. Several candidates for this gas are briefly considered.

Trafton, L.↗

Observations of the 30 micron feature in IRC + 10216

Infrared observations from 30 to 37 microns of IRC+10216 extend the wavelength coverage of the 30-micron feature found in four carbon stars and two planetary nebulae by Forrest, Houck, and McCarthy (1981). The present data confirm the existence of this newly observed feature and determine its shape beyond 30 microns. The determination of the long-wavelength end of the spectral excess depends critically on the assumed underlying continuum. A combined spectrum of the excess is presented and shows the feature to extend to at least 37 microns.

Herter, T.↗

Near-Infrared Hyperspectral Image Cubes of Mars during the 1999 Opposition

We used the Goddard Space Flight Center, Acousto-Optic Tunable Filter (AOTF) Camera to obtain near-IR spectral image sets of Mars over the 1.6-3.6 micron region during the April 1999 opposition. A complete image set consists of 280 images with a spectral full-width-half maximum of 10 wavenumbers (fixed in frequency), 90 images in H-band (1.55-1.80 micron), 115 images in K-band (1.95-2.50 micron) and 75 images in L-band (2.90-3.70 micron). The short-wavelength limit is set by transmission of AOTF cell and long-wavelength limit is imposed by sensitivity of PICNIC, 256x256, HgCdTe array detector. We will discuss the new array performance and provide preliminary interpretations of some of these results. These measurements were part of a 4-observatory coordinated effort whose overall objective was to assemble a photometrically calibrated, spectrally complete ground-based image cube over the visible and near-IR spectral region. To accomplish this, four observing teams conducted the investigations with instruments spanning 0.4 to 5.0 micron. The instruments and observing facilities were (a) AOTF camera at Apache Point Observatory, 3.5m, f/10, Nasymth focus (this abstract). Primary science targets included the 3 micron water-of hydration feature and CO2, H2O ice (polar regions and clouds); (b) Visible/NIR interference-filter (24 filters) camera at Lowell Observatory, 72" telescope. 430-1050 nm. Science targets were Fe(2+), Fe(3+) mineralogy and coarse grain hematite search; (c) NMSU Tortugas Mountain Observatory, 60 cm telescope, CCD photometry with same filter set as Lowell; (d) KPNO cryogenic grating/slit spectrometer (CRSP/SALLY) at KPNO 2.1 m, f/15 Cassegrain focus (see abstract by D. Glenar, et. al., this meeting). Selected wavelengths in 3-5 micron region (L, M band). Science targets included water-of-hydration feature (3-4 micron long wave extension) and sulfate mineralogy. Observers participating in this campaign included Dave Glenar, John Hillman, Gordon Bjoraker and Fred Espenak from GSFC, Nancy Chanover, Jim Murphy and A. S. MurTell from NMSU, Leslie Young from BU, Diana Blaney from JPL and Dick Joyce from KPNO.

Hillman, John J.↗

FPA Needs for NASA Missions

NASA has identified needs for a broad range of specialized, optimized infrared detectors and IR detector arrays to meet its future mission requirements. Space infrared missions will be conducted in a number of discipline areas, including astrophysics, earth and atmospheric science, planetary systems, and space physics. To allow investigators to meet scientific goals, specific technical requirements for infrared detectors have been developed. These challenging and often unique requirements include, for example, achieving background-limited performance in a cryogenic space telescope; developing long-wave IR arrays which achieve near background-limited performance at elevated (approximately 60 kelvin) operating temperatures; achieving IR arrays with large two-dimensional formats, excellent uniformity and linearity, and low power dissipation; demonstrating an imaging array technology for very long-wavelength (less than 100 microns) IR sensing, and IR devices with extremely low dark current levels; and demonstrating stable, low-noise, low-dissipation readouts. These requirements can in some cases be met by adaptation or extension of technologies originally developed by DoD. In other cases, the novel spectral range or other characteristics require unique solutions. Examples are given of recent scientific results which have been made possible with IR arrays. These serve as a preview of the kinds of science return which can be enabled by advanced IR focal plane technology from space platforms.

McCreight, Craig R.↗

The Case for Moderately-Cooled, Far-Infrared Thermal Detectors

There are moderately-cooled (around 77K) infrared detectors, for instance InSb (around 5 microns wavelength) and HgCdTe (around 15 to 20 microns wavelength). However for longer wavelengths there are either uncooled thermal-type detectors or highly cooled (about 4K and lower) quantum and thermal detectors, with the notable exception of high Tc superconductor detectors. We will describe certain long-wavelength applications in space where only moderate cooling is feasible, and where better sensitivity is required than possible with uncooled detectors. These requirements could be met with high Tc bolometers, but it may also be prudent to develop other technologies. Additionally, over the past 16 years a marketplace has not developed for the commercial production of high Tc bolometers, indicating their production may be a natural endeavor for government laboratories.

Brasunas, John C.↗

Heated Surface Temperatures Measured by Infrared Detector in a Cascade Environment

Investigators have used infrared devices to accurately measure heated surface temperatures. Several of these applications have been for turbine heat transfer studies involving film cooling and surface roughness, typically, these measurements use an infrared camera positioned externally to the test section. In cascade studies, where several blades are used to ensure periodic flow, adjacent blades block the externally positioned camera's views of the test blade. To obtain a more complete mapping of the surface temperatures, researchers at the NASA Glenn Research Center fabricated a probe with an infrared detector to sense the blade temperatures. The probe size was kept small to minimize the flow disturbance. By traversing and rotating the probe, using the same approach as for total pressure surveys, one can find the blade surface temperatures. Probe mounted infrared detectors are appropriate for measuring surface temperatures where an externally positioned infrared camera is unable to completely view the test object. This probe consists of a 8-mm gallium arsenide (GaAs) lens mounted in front of a mercury-cadmium-zinc-tellurium (HgCdZnTe) detector. This type of photovoltaic detector was chosen because of its high sensitivity to temperature when the detector is uncooled. The particular application is for relatively low surface temperatures, typically ambient to 100 C. This requires a detector sensitive at long wavelengths. The detector is a commercial product enclosed in a 9-mm-diameter package. The GaAs lens material was chosen because of its glass-like hardness and its good long-wavelength transmission characteristics. When assembled, the 6.4-mm probe stem is held in the traversing actuator. Since the entire probe is above the measurement plane, the flow field disturbance in the measurement plane is minimized. This particular probe body is somewhat wider than necessary, because it was designed to have replaceable detectors and lenses. The signal for the detector is fed through the hollow probe body. The detector's signal goes to an externally mounted preamplifier. The detector assembly, along with a preamplifier, is calibrated as a function of the surface temperature for various detector temperatures. The output voltage is a function of both the detector and object temperatures.

Boyle, Robert J.↗