Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC INDUCTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Isothermal magnetostatic atmospheres. III - Similarity solutions with current proportional to the magnetic potential squared

A family of isothermal magnetostatic atmospheres with one ignorable coordinate corresponding to a uniform gravitational field in a plane geometry is considered. It is assumed that the current (J) is proportional to the square of the magnetostatic potential and falls off exponentially with distance. Results are presented for the contributions of the anisotropic J x B force (where B is the magnetic field induction), the gravitational force, and the gas pressure gradient to the force balance.

Webb, G. M.↗

Advanced electric motor technology flux mapping

Design of electric motors which fulfill the needs of Thrust Vector Control (TVC) actuators used in large rocket propelled launch vehicles is covered. To accomplish this end the methodology of design is laid out in some detail. In addition a point design of a motor to fulfill the requirements of a certain actuator specified by MSFC is accomplished and reported upon. In the course of this design great stress has been placed on ridding the actuator of internally generated heat. To conduct the heat out of the motor use is made of the unique properties of the in house MSFC designed driving electronics. This property is that as along as they are operated in a quasi-linear mode the electronics nullify the effects of armature inductance as far as the phase of the armature current versus the rotor position is concerned. Actually the additional inductance due to the extended end turns in this design is of benefit because in the shorted armature failure mode the armature current in the fault (caused by the rotor flux sweeping past the armature) is diminished at a given rotor speed when compared to a more conventional motor with lower inductance. The magnetic circuit is analyzed using electromagnetic finite element methods.

Doane, George B., III↗

Pulsed Fission-Fusion (PuFF)

In September 2013 the NASA Innovative Advanced Concept (NIAC) organization awarded a phase I contract to the PuFF team. Our phase 1 proposal discussed a pulsed fission-fusion propulsion system that injected gaseous deuterium (D) and tritium (T) as a mixture in a column, surrounded concentrically by gaseous uranium fluoride (UF6) and then an outer shell of liquid lithium. A high power current would flow down the liquid lithium and the resulting Lorentz force would compress the column by roughly a factor of 10. The compressed column would reach criticality and a combination of fission and fusion reactions would occur. The fission reactions would further energize the fusion center, and the fusion reactions would generate neutrons that promote more complete burnup of the fission fuel. The lithium liner provides some help as a neutron reflector but also acts as a propulsive medium, being converted to plasma which is then expanded against a magnetic nozzle for thrust. The expansion of the (primarily) lithium plasma against the nozzle's magnetic field inducts a current that is used to charge the system for the next pulse. Our concept also included secondary injection of a Field Reversed Configuration (FRC) plasmoid that would provide a secondary compression direction, axially against the column, and push the column away from the injection manifold, increasing the manifold's survivability.Our phase 1 proposal included modeling the above process first under steady state assumptions and second under a time variant integration. We proposed including these results into a Mars concept vehicle and finally proposing promising conditions to be evaluated experimentally in Phase II. In phase I we quickly realized that we needed to modify our approach. Our steady state work was completed as proposed, and the results indicated that one, a two stage compression system was not needed and two, that we wanted to move away from UF6. The steady state model shows much more margin than expected, to the point that we may well reach breakeven with the Charger – 1 facility, a 572 kJ Marx bank currently under refurbishment at UAH. Additionally we found that using gaseous D-T and UF6, provided a relatively simple prospect of using a pulsed injector, made reaching criticality more difficult. The introduction of large amounts of fluorine meant a radiative sink, sapping power from the fusion plasma and was harder to handle. Therefore we moved to a solid uranium target that held D-T under pressure. In so doing we could move our target closer to criticality and remove any material that did not sustain the reaction.

Fusion↗

Qualifying the Sunpower M87N Cryocooler for Operation in the AMS-02 Magnetic Field

The Alpha Magnetic Spectrometer-02 (AMs-02) experiment uses a superfluid helium dewar to cool a large superconducting magnet. The outer vapor-cooled shields of the dewar are to be held at 80 K by four Sunpower M87N cryocoolers. These cryocoolers have magnetic components that might interact with the external applied field generated by the superconducting magnet, thereby degrading the cryocoolers' performance. Engineering models of the Sunpower M87 have been qualified for operation in a magnetic environment similar to the AMs-02 magnetic environment. Although there was no noticeable performance degradation at field levels that were comparable to AMs-02 field levels, there appears to be a small performance degradation at higher field levels. It was theorized that there were three possible issues related to these performance losses at high magnetic fields: i) induced piston rubbing on the cylinder wall due to forces and torques on the linear motor due to the applied magnetic fields; ii) Magnetic hysteretic and/or eddy current damping of the balancer due to its motion in the applied magnetic fields; iii) Inductance losses in motor due to the applied magnetic field. The experiments conducted at the Massachusetts Institute of Technology (MIT) cyclotron facility in June 2002 were designed to test these. Tests were performed over a range of field levels that were lower, comparable, and higher than the field levels that the cryocoolers will experience in the AMs-02 operating environment. This paper describes the experiments and the inferences derived from them.

Mustafi, Shuvo↗

Comparison of an Inductance In-Line Oil Debris Sensor and Magnetic Plug Oil Debris Sensor

The objective of this research was to compare the performance of an inductance in-line oil debris sensor and magnetic plug oil debris sensor when detecting transmission component health in the same system under the same operating conditions. Both sensors were installed in series in the NASA Glenn Spiral Bevel Gear Fatigue Rig during tests performed on 5 gear sets (pinion/gear) when different levels of damage occurred on the gear teeth. Results of this analysis found both the inductance in-line oil debris sensor and magnetic plug oil debris sensor have benefits and limitations when detecting gearbox component damage.

Dempsey, Paula J.↗

What Would a Dynamo Theorist like to Know About the Dynamics of the Solar Convection Zone?

Observations about the current status of solar dynamo theory are given. The induction equation for magnetic field is solved using assumed velocities and parametric representations of the inductive or diffusive effects of velocities. The equations of motion governing these flow are not solved in parallel. Results from global compressible convection models are discussed. Differential rotation and convection are also investigated.

Gilman, P. A.↗

High-T(sub c) squid application in medicine and geophysics

In the Laboratory a high-T(sub c) one-hole squid was built from Y1Ba2Cu3O(7-x) ceramics obtained by a standard procedure of solid state reaction. The ceramics with critical current density J(sub c) is greater than 100 A/sq cm was selected. In the middle of 10 x 10 x 2 mm ceramics pellet a 0.8 mm hole was drilled in which superconducting loop of the squid was located. Between the hole and the edge of the pellet a cut was mechanically filed out with a bridge inside it connecting the superconducting ring. A scheme of the magnetometer is presented. The resonant frequency shift of the tank circuit, the connection of the squid with this circuit, and the squid inductance are evaluated. One of the most interesting fields of the squid-based magnetometer application is biomagnetism, particularly, the human heart magnetocardiogram measuring. The low-temperature squids were used in this area and many interesting and important scientific results have been obtained. The observations have shown that the main noise contribution was not due to the squid but to the Earth's magnetic field variations, industrial inductions, and mainly to the vibrations caused by liquid nitrogen boiling and by vibrations of the box. Further attempts are needed to reduce the magnetic noise inductions. Nevertheless, the estimations promise the maximum signal/noise relation of the high-T(sub c) squid-magnetocardiometer to be not less than 10:1 in a bandwidth of 60 Hz. Apparently, such resolution would be enough not only for steady cardiogram reading but even for thin structure investigation at average technique application.

Polushkin, V. N.↗

High-T(c) squid application in medicine and geophysics

In our laboratory of high-T(sub c), a one-hole squid was built from Y1Ba2Cu3O(7-x) ceramics obtained by a standard procedure of solid state reaction. The ceramics with critical current density J(sub c) is greater than 100 A/sq cm was selected. In the middle of a 10 x 10 x 2 mm ceramics pellet, a 0.8 mm hole was drilled in which the superconducting loop of the squid was located. Between the hole and the edge of the pellet, a cut was mechanically filed out with a bridge inside it connecting the superconducting ring. A scheme of the magnetometer is presented. The resonant frequency shift of the tank circuit, the connection of the squid with this circuit, and the squid inductance are evaluated. One of the most interesting fields of the squid-based magnetometer application is biomagnetism, particularly, the human heart magnetocardiogram measuring. The low-temperature squids were used in this area and many interesting and important scientific results have been obtained. The observations have shown that the main noise contribution was not due to the squid but to the Earth's magnetic field variations, industrial inductions, and mainly to the vibrations caused by liquid nitrogen boiling and by vibrations of the box. Further attempts are needed to reduce the magnetic noise inductions. Nevertheless, the estimations promise the maximum signal/noise relation of the high-T(sub c) squid-magnetocardiometer to be not less than 10:1 in a bandwidth of 60 Hz. Apparently, such resolution would be enough not only for steady cardiogram reading but even for thin structure investigation at average technique application.

Polushkin, V. N.↗

Hematite Versus Magnetite as the Signature for Planetary Magnetic Anomalies?

Crustal magnetic anomalies are the result of adjacent geologic units having contrasting magnetization. This magnetization arises from induction and/or remanence. In a planetary context we now know that Mars has significant crustal magnetic anomalies due to remanent magnetization, while the Earth has some anomalies where remanence can be shown to be important. This picture, however, is less clear because of the nature and the magnitude of the geomagnetic field which is responsible for superimposed induced magnetization. Induced magnetization assumes a magnetite source, because of its much greater magnetic susceptibility when compared with other magnetic minerals. We investigated the TRM (thermoremanent magnetization) acquisition of hematite, in weak magnetic fields up to 1 mT, to determine if the remanent and induced magnetization of hematite could compete with magnetite. TRM acquisition curves of magnetite and hematite show that multi-domain hematite reaches TRM saturation (0.3 - 0.4 A sq m/kg) in fields as low as 100 microT. However, multi-domain magnetite reaches only a few percent of its TRM saturation in a field of 100 microT (0.02 - 0.06 A sq m/kg). These results suggest that a mineral such as hematite and, perhaps, other minerals with significant remanence and minor induced magnetization may play an important role in providing requisite magnetization contrast. Perhaps, and especially for the Mars case, we should reevaluate where hematite and other minerals, with efficient remanence acquisition, exist in significant concentration, allowing a more comprehensive explanation of Martian anomalies and better insight into the role of remanent magnetization in terrestrial crustal magnetic anomalies.

Kletetshka, Gunther↗

An Integrated Magnetic Circuit Model and Finite Element Model Approach to Magnetic Bearing Design

A code for designing magnetic bearings is described. The code generates curves from magnetic circuit equations relating important bearing performance parameters. Bearing parameters selected from the curves by a designer to meet the requirements of a particular application are input directly by the code into a three-dimensional finite element analysis preprocessor. This means that a three-dimensional computer model of the bearing being developed is immediately available for viewing. The finite element model solution can be used to show areas of magnetic saturation and make more accurate predictions of the bearing load capacity, current stiffness, position stiffness, and inductance than the magnetic circuit equations did at the start of the design process. In summary, the code combines one-dimensional and three-dimensional modeling methods for designing magnetic bearings.

Provenza, Andrew J.↗

PT-1 Plasmoid Thruster Capable of Multi-Mode Operation

This slide presentation reviews the concept of a Plasmoid Thruster that is capable of operating in several different modes. A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust. The Drive and Bias circuits, the gas distribution, the pre-ionization stage, and the operation sequence are detailed. The advantages of the Plasmoid thruster and the research and technology required for development of this form of propulsion is reviewed.

Miller, Robert↗

Topology of induced lunar magnetic fields

Using the asymmetric theory of lunar induction the total and induced magnetic field line structure within the Moon and the diamagnetic cavity were obtained. Total field distributions are shown for orientations of the oscillating interplanetary field parallel, perpendicular and at 45 deg to the cavity axis. Induced field lines are shown only for the orientations of the interplanetary field parallel and orthogonal to the cavity axis. When compared with the field lines derived using the long wavelength limit of spherically symmetric vacuum induction theory, the configurations obtained using the asymmetric theory exhibit significant distortion. For all orientations of the interplanetary field, the field lines are strongly compressed on the sunlit hemisphere because of the confining solar wind pressure at the lunar surface and the exclusion of the field by the lunar core.

Schwartz, K.↗

Magnetic and Langmuir Probe Measurements on the Plasmoid Thruster Experiment (PTX)

The Plasmoid Thruster Experiment (PTX) operates by inductively producing plasmoids in a conical theta-pinch coil and subsequently ejecting them at high velocity. An overview of PTX is described in a companion paper. The shape and magnetic field structure of the translating plasmoids will be measured with of an array of inductive magnetic field probes. Six sets of two B-dot probes (for a total of twelve probes) have been constructed for measuring B(sub z) and B(sub theta), the axial and azimuthal components of the magnetic field. The probes were calibrated with a Helmholtz coil, driven alternately by a high-voltage pulser or a signal generator. The probes are wound on a G-10 form, and have an average (calibrated) NA of 9.37 x 10(exp -5) square meters, where N is the number of turns and A is cross-sectional area. The frequency response of the probes was measured over the range from 1 kHz to 10 MHZ. The electron number density n(sub e), electron temperature T(sub e) and velocity v will be determined from measurements taken with a quadruple Langmuir probe, situated in the exhaust chamber. Three of the four probes on the quadruple probe sample the current-voltage characteristic, and from this yield measurements of T(sub e) and n(sub e). The fourth probe provides a measurement of plasma flow velocity. A 6-inch long alumina rod, hollowed with four holes to house the probe wires, is being used to construct the quadruple probe. A variety of propellants will be used, including hydrogen, nitrogen and argon. From the measurements of the plasmoid mass, density, temperature, and velocity, the basic propulsion characteristics of PTX will be evaluated.

Koelfgen, Syri J.↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sub p/B(sub t) much greater than 1 it is an FRC; if B(sub p) approximately equal to B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust, This concept should be capable of producing an Isp in the range of 5,000 - l0,000 seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated liable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing preionization circuit to independently control ionization has been tested, hydrogen, deuterium, argon, and an N2 / H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented.

Martin, Adam↗

The Plasmoid Thruster Experiment (PTX)

A plasmoid is a compact plasma structure with an integral magnetic field, that may be categorized according to the relative strength of the poloidal and toroidal magnetic fields. If B(sup p)/B(sub t) is much greater than 1, it is an FRC; if B(sub p) approximately equals B(sub t), it is a Spheromak. A plasmoid thruster would operate by repetitively producing plasmoids that are accelerated to high velocity. The process is inductive, and the magnetic structure of the plasmoid suppresses thermal and mass losses, and improves detachment of the exhaust. This concept should be capable of producing an Isp in the range of 5,000 - 10,OOO seconds, with high thrust density. PTX is a device designed to study this concept. The plasmoid is formed inside of a single turn conical theta-pinch coil, driven by a 560 nF, 35 kV capacitor bank. Experiments conducted with a static-fill of propellant gas (6% H2 in He) demonstrated reliable ionization over a pressure range of 40 - 200 mTorr. A fast gas-puff valve to inject propellant has since been added, and a ringing pre-ionization circuit to independently control ionization has been tested. Hydrogen, deuterium, argon, and an N2/H2 mixture have been tried as propellants. Measurements of the plasmoid shape, mass, and velocity, using a variety of diagnostics will be presented,

Martin, Adam↗