Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Advanced flip-coil system for magnetic field integral measurements of insertion devices

A novel flip-coil measurement system has been developed for the National Synchrotron Light Source II (NSLS-II) at Brookhaven National Laboratory. This paper describes the design, implementation, and commissioning of the new measurement bench, highlighting its key features, including improved mechanical stability, advanced data acquisition, and enhanced reproducibility. The system enables precise characterization of field integrals and multipole components, ensuring the optimal performance of Insertion Devices (IDs) before installation in the NSLS-II storage ring. The flip-coil system incorporates an innovative approach to minimize mechanical and electrical errors, which significantly improves the reproducibility of measurements. In addition, the system features a state-of-the-art data acquisition system that enables real-time monitoring and analysis, further enhancing the efficiency and accuracy of the measurement process. Furthermore, preliminary tests have demonstrated that the new system meets the stringent requirements for magnetic field characterization of advanced insertion devices, making it an essential tool for future ID commissioning and quality assurance at NSLS-II.

36 MATERIALS SCIENCE↗

Measuring the Muon Neutrino Magnetic Moment in the NOvA Near Detector

Measuring an enhanced neutrino magnetic moment would be a clear indication of physics beyond the Standard Model, shedding light on the correct beyond Standard Model theory or the potential Majorana nature of neutrinos. It would manifest in the NOvA near detector as an excess of neutrino-on-electron elastic scattering interactions at low electron recoil energies. Leveraging an intense and highly pure muon neutrino beam, along with a finely segmented liquid scintillator detector technology specifically designed for electromagnetic shower separation, enables NOvA to achieve a potentially world-leading sensitivity in probing the effective muon neutrino magnetic moment. This analysis, based on neutrino data collected between 2014 and 2021, corresponding to an exposure of $13.8\times10^{20}$ protons-on-target, yields a result consistent with the Standard Model-only hypothesis with a p-value of 0.31. An upper limit on the effective muon neutrino magnetic moment is set at $\mu_{\nu_\mu}<19.1\times 10^{-10}\mu_B$ at $90\%$ confidence level. Despite facing statistical limitations stemming from low cross section of the signal process, systematic uncertainties have a significant impact on this result. To address these challenges, the NOvA Test Beam experiment focuses on mitigating some of the largest systematic uncertainties within NOvA by investigating particle interactions and energy deposition in a small-scale replica NOvA detector. This thesis describes the calibration of the NOvA Test Beam detector, which is a crucial step in analysing the Test Beam data before they can be utilised to reduce NOvA systematic uncertainties.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES↗

Properties of Cosmic Lithium Isotopes Measured by the Alpha Magnetic Spectrometer

We present the first measurement of cosmic-ray fluxes of 6 Li and 7 Li isotopes in the rigidity range from 1.9 to 25 GV. The measurements are based on 9.7 × 10 5 6 Li and 1.04 × 10 6 7 Li nuclei collected by the Alpha Magnetic Spectrometer on the International Space Station from May 2011 to October 2023. We observe that over the entire rigidity range the 6 Li and 7 Li fluxes exhibit nearly identical time variations and, above ∼4 GV, the time variations of 6 Li , 7 Li , He, Be, B, C, N, and O fluxes are identical. Above ∼7 GV, we find an identical rigidity dependence of the 6 Li and 7 Li fluxes. This shows that they are both produced by collisions of heavier cosmic-ray nuclei with the interstellar medium and, in particular, excludes the existence of a sizable primary component in the 7 Li flux.

cosmic ray acceleration↗

Electron-impact excitation data for W 2+ in support of tungsten spectroscopy and re-deposition measurements for magnetically-confined plasmas

Abstract To better understand plasma wall interactions involving tungsten, accurate atomic structure and electron-impact driven collisional processes for near-neutral ion stages of tungsten are required. Complementing existing work on neutral and singly ionised tungsten, atomic structure and collisional calculations for W 2+ electron-impact excitation have been completed. These excitation calculations are an important component of S/XB coefficients for near-neutral charge states, which may be used to spectroscopically infer re-deposition of tungsten at the plasma-solid boundary of fusion relevant devices. With W 2+ in particular having emission lines that can be observed at ultraviolet (UV) wavelengths, while higher charge states of tungsten are unlikely to have lines possible to observe outside of the vacuum UV range. The atomic structure was generated using the General-purpose Relativistic Atomic Structure Package (GRASP 0 ), implementing the Multi-configuration Dirac Fock approach. This structure was the basis for a subsequent Dirac R -matrix electron-impact excitation calculation to provide Maxwellian averaged rate coefficients. A synthetic spectrum was generated from this data using a collisional-radiative model to predict the strongest W III spectral lines and these lines were compared to emission from the Compact Toroidal Hybrid (CTH) plasma device. Several of the strongest W III lines are observed in CTH and agree well with the modelled line wavelengths and intensities, a table of these lines is provided that could be observed in other devices.

McCann, M. (ORCID:0000000215321240)↗

Field-induced magnetization of δ -plutonium from density functional theory

Here, we present results from density functional theory (DFT) calculations of magnetization, induced by an external magnetic field, for δ-phase plutonium. The fully relativistic electronic structure accounts for Zeeman splitting effects through a Hamiltonian that couples the magnetic field to both spin and orbital magnetic moments. The electronic-structure model is further improved by an extension to DFT in terms of an orbital-orbital coupling via the conventional orbital-polarization method, as has routinely been done for plutonium. The response to the applied magnetic field is shown to be weak in the DFT model, with induced magnetic moments of the order of in magnetic fields up to 30 T. These results are in accord with recent assessments from x-ray magnetic circular dichroism measurements in magnetic field on δ-plutonium. Somewhat surprisingly, a model assuming δ-plutonium to be absent magnetic moments shows stronger response to an external static magnetic field than models allowing for antiferromagnetism or magnetic disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Measurement of the muon magnetic anomaly to 0.20 ppm by the Muon g-2 experiment at Fermilab

The Muon $g-2$ experiment at Fermilab aims to measure the muon magnetic moment anomaly, $a_{\mu}=(g-2)/2$, with a final accuracy of 0.14 parts per million (ppm). The experiment’s first result was published in 2021, based on data collected in 2018, and in 2023 a new result was published based on two more years of data taking, 2019 and 2020. The combination of the two results from Fermilab and the previous one from Brookhaven National Laboratory brought the uncertainty on the experimental measurement of $a_{\mu}$ to the unprecedented value of 0.19 ppm. This paper will present details about the improvements of statistical and systematic uncertainties on $a_{\mu}$ since the 2021 result.

Cotrozzi, Lorenzo [Liverpool U.; INFN, Pisa]↗

Nanoscale Observation and Control of Quasiparticle Induced Magnetic Noise in a Superconducting Resonator

Superconducting circuits are arguably taking a leading role in driving the ongoing quantum technological revolution. A detailed knowledge of the microscopic fluctuating electromagnetic properties plays an important role in advancing the circuitry design, testing, and material integration of cutting-edge superconducting quantum electronics. Here, in this work, we report scanning nitrogen-vacancy (NV) quantum sensing of local magnetic noise environment of an on-chip superconducting resonator. We find that quasiparticle-induced fluctuating magnetic fields can drive NV spin relaxation, which shows a peak value around the superconducting transition point of niobium at the thermal equilibrium state. External microwave driving at the resonator mode frequency significantly increases the quasiparticle density, leading to enhancement of magnetic noise. We further perform optically detected magnetic resonance measurements to demonstrate quasiparticle magnetic noise mediated off-resonant dipole coupling between the NV center and niobium resonator. Our Letter reports experimental observation of the Hebel-Slichter peak signature by an external sensor outside of a superconductor. The presented study also highlights the advantages of quantum sensors in investigating miniaturized superconducting devices, providing insights into their future performance improvements.

Li, Senlei [Georgia Institute of Technology]↗

Mapping Dark Matter on Small Scales with the Cosmic Microwave Background (Final Report)

Sehgal was funded by DOE Grant DE-SC0020441 over the period from 11/1/2019 - 04/30/2024 (no remaining funds are anticipated). Most recently, Sehgal and her group completed a publication forecasting cosmological parameter constraints for a CMB-HD survey, in addition to SO and CMB-S4 (1). One focus of this work was determining the improvement in parameter constraints when removing the gravitational lensing effect from the primordial CMB (a process called delensing). This work also explored the bias to parameters from neglecting baryonic effects, and ways to mitigate that. In addition, this work highlighted that a CMB-HD N eff measurement could tightly constrain the QCD axion in a modelindependent way (see left panel of Figure 1). Sehgal also developed a novel way to probe inflation via CMB experiments by measuring inflationary magnetic fields (IMFs) (2). IMFs are thought to seed the large magnetic fields we observe in galaxies today, and can be measured by looking for anisotropic rotation of the CMB polarization vectors across the sky (an effect called cosmic birefringence). The cosmic birefringence from IMFs has a unique frequency dependence, allowing it to be separated from other sources of cosmic birefringence. In (2), Sehgal and her postdoc also presented a novel way to remove foreground contamination from Galactic magnetic fields using measurements of the polarization of nearby radio sources. The removal of this Galactic contamination is necessary when measuring IMFs at the level of 0.1 nG; IMFs with a strength of at least 0.1 nG are needed to seed the magnetic fields in galaxies we observe today. Since only inflation can generate such a strong magnetic field, measuring such a signal would be a “smoking gun” signature that inflation occurred. Sehgal showed in (2) that CMB-HD could detect such IMFs with at least 3σ significance (see right panel of Figure 1).

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Error field measurements and correction on MUSE permanent magnet stellarator

The magnetic field topology and error fields are measured in the MUSE permanent magnet stellarator with an electron beam and fluorescent rod. The effective magnetization of the magnets is determined by measuring rational flux surface locations. Electron magnetic drift effects must be considered self-consistently due to the small magnetic shear on MUSE. Error fields are characterized by flux surface shape deviation and magnetic island chain width and phase. Error fields are then corrected by adjusting the permanent magnet (PM) holders as rigid bodies. Resonant error fields are on the order of or smaller than 3 x 10 -6 of the toroidal field after correction and surface shape matches well with the design. Resonant components of the quasi-symmetry deviation are estimated, using a novel magnetic drift measurement, to be in the 10 −4 range. The PM approach is validated as a low-cost and precise way to build optimized stellarators.

electron beam mapping↗

Transitions, Dynamics, and Driven States in Quantum Magnets (Final Report Revised)

Transitions into unusual electronic, optical, and magnetic states at the absolute zero of temperature display special properties that teach us about fundamental quantum mechanics and also underlie important technologies. These so-called quantum phase transitions intertwine the static and dynamical responses of the materials changing state. They are extremely sensitive to the effects of disorder and etch in high relief the role of quantum fluctuations. There are ample questions remaining about the character of such transitions and the nature of the competing quantum states. There are also opportunities to drive quantum materials out of equilibrium, with the possibility of new types of correlated and coherent order, and new ways to access the dynamical evolution of ground and excited states. We have investigated how the order develops in time and space, and the nature of the final configurations. We are able to compare and contrast classical and quantum excitations in our experimental system of choice, and thereby can trace the relative speed by which the system settles into its lowest-energy ground state. This comparison of quantum and classical annealing protocols lies at the heart of strategies for harnessing the power of quantum computers dedicated to optimization problems. A combination of magnetic susceptibility measurements at finite frequency where the magnetic spins are queried by an external ac field, dc magnetometry measurements that characterize the macroscopic strength of magnetic order and its resistance to change, noise measurements that reveal the microscopic fluctuations of the spins as they prepare to change state, and microwave spectroscopy to look at the response of both the electronic and nuclear degrees of freedom, have been performed as functions of temperature, magnetic field, frequency, excitation amplitude, magnetic spin concentration, and disorder. This combination of probes addresses issues of stability over time, overlap between spin states, the ability of the spins to respond independently or coherently, and the promise of control on the nanometer length scale. The research reported here provides insights into fundamental quantum physics. It also addresses the question of how best to use complex systems, such as magnetic solids, to stably process quantum information.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of the Neutron Magnetic Form Factor at Large Momentum Transfer Using the Super-Bigbite Apparatus in Jefferson Lab Hall-A

The nucleon elastic electromagnetic form factors help us study the electromagnetic structure of the nucleon, benchmark theoretical models, and improve our understanding of non-perturbative quantum chromodynamics and confinement. The Nobel Prize-winning electron-nucleon scattering experiments by Robert Hofstadter and collaborators in the 1950s at Stanford High Energy Physics Lab were the first nucleon form factor measurements performed using leptonic probes. The Super Bigbite Spectrometer (SBS) program at Hall-A of Jefferson Lab represents the latest efforts to measure nucleon form factors. This ambitious program aims to significantly extend the current data set in terms of square momentum transfer (Q2) with high precision. The advent of novel detector technologies, like Gas Electron Multipliers (GEM), which provide excellent position resolution (< 100 ?m) while withstanding high background particle rates (several hundred MHz/cm2) over a large active area, has paved the way for open-geometry, moderate solid angle spectrometers, which are central to all form factor experiments in the SBS program. The first experimental run group in SBS ran successfully between September 2021 and February 2022, collecting data for the measurement of the magnetic form factor of the neutron Gn M at five squared momentum-transfer values: 3.0, 4.5, 7.5, 9.8, and 13.5 (GeV /c)2. This extends the existing high-precision data for Gn M by about a factor of four. The ratio technique was used, which involved the simultaneous measurement of exclusive quasielastic scattering of D(e,e?n)p and D(e,e?p)n from a deuterium target. Pre-preliminary results for D(e,e?n)p and D(e,e?p)n quasi-elastic ratio, and the neutron magnetic form factor Gn M , for Q2 points 3.0, 9.8, and 13.5 (GeV /c)2 are presented.

Mudiyanselage, Anuruddha Rathnayake↗

Polarized neutron measurements of the internal magnetization of a ferrimagnet across its compensation temperature

We present the first polarized neutron transmission image of a model Néel ferrimagnetic material, polycrystalline terbium iron garnet (Tb 3 Fe 5 O 12 , TbIG for short), as it is taken through its compensation temperature T comp where the macroscopic magnetization vanishes. Our polarized neutron imaging data and the additional supporting measurements using neutron spin echo spectroscopy and SQUID magnetometry are all consistent with a vanishing internal magnetization at T comp .

Ferrimagnetism↗

Measurement of the positive muon anomalous magnetic moment to 127 ppb

A new measurement of the magnetic anomaly $a_μ$ of the positive muon is presented based on data taken from 2020 to 2023 by the Muon $g-2$ Experiment at Fermi National Accelerator Laboratory (FNAL). This dataset contains over 2.5 times the total statistics of our previous results. From the ratio of the precession frequencies for muons and protons in our storage ring magnetic field, together with precisely known ratios of fundamental constants, we determine $a_μ = 116\,592\,0710(162) \times 10^{-12}$ (139 ppb) for the new datasets, and $a_μ = 116\,592\,0705(148) \times 10^{-12}$ (127 ppb) when combined with our previous results. The new experimental world average, dominated by the measurements at FNAL, is $a_μ(\text{exp}) =116\,592\,0715(145) \times 10^{-12}$ (124 ppb). The measurements at FNAL have improved the precision on the world average by over a factor of four.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Measurement of the Neutron Magnetic Form Factor Using Super-BigBite Spectrometer at Jefferson Lab

The GMn experiment (E12-09-019) was conducted at Jefferson Laboratory from late 2021 into early 2022. The goal was to make high-precision measurement of the neutron’s magnetic form factor (GMn) at multiple kinematic points, including Q2 = 3.5, 4.5, 6.5, 8.5, 10, 12, 13.5, 16, and 18 (GeV/c)2. Limited data exist for GMn in the region up to about Q2 = 10 (GeV/c)2, with existing data having large systematic uncertainty. In this experiment, the ratio method was employed to reduce systematic uncertainty by measuring the ratio of neutron and proton yields. The experiment took place at Jefferson Laboratory in Hall A, where the BigBite spectrometer was used to detect the scattered electrons, while the HCal in the SuperBigbite spectrometer was used to detect both neutrons and protons. The protons were deflected slightly upwards with the use of a large-aperture dipole magnet named BigBen, allowing for enhanced particle identification. Extraction of GMn requires taking the ratio of proton and neutron yields. Analysis efforts are still currently underway to refine corrections to the data, including detector efficiencies, radiative corrections, neutron and proton mass identification, and charge exchange.

Lashley-Colthirst, Nathaniel↗

Gradient Technique Theory: Tracing Magnetic Field and Obtaining Magnetic Field Strength

Abstract The gradient technique is a promising tool with theoretical foundations based on the fundamental properties of MHD turbulence and turbulent reconnection. Its various incarnations use spectroscopic, synchrotron, and intensity data to trace the magnetic field and measure the media magnetization in terms of Alfvén Mach number. We provide an analytical theory of gradient measurements and quantify the effects of averaging gradients along the line of sight and over the plane of the sky. We derive analytical expressions that relate the properties of gradient distribution with the Alfvén Mach number M A . We show that these measurements can be combined with measures of sonic Mach number or line broadening to obtain the magnetic field strength. The corresponding technique has advantages to the Davis–Chandrasekhar–Fermi way of obtaining the magnetic field strength.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Measurements of the Neutron Magnetic Form Factor to High Momentum Transfer using Durand's Method

Protons and neutrons, collectively known as nucleons, along with electrons, constitute the funda- mental building blocks of the visible universe. Understanding their internal structure is crucial for addressing key scientific questions about our origin and existence. Elastic electron-nucleon scatter- ing provides insights into the spatial distributions of charge and current within nucleons through their electromagnetic form factors. Accurate knowledge of these form factors over a broad range of Q2, the squared four-momentum transfer in the scattering process, reveals details about the nucleon’s internal structure. However, high-Q2 data of the nucleon electromagnetic form factor is scarce due to the challenges associated with such measurements. This thesis reports preliminary results from high-precision measurements of the neutron magnetic form factor (Gn M ) to unprecedented Q2 using Durand’s method, also known as the “ratio” method. Systematic errors are greatly reduced by extracting Gn M from the ratio of neutron-coincident (D(e, e'n)) to proton-coincident (D(e, e'p)) quasi-elastic electron scattering from deuteron. The scattered electrons were detected in the BigBite spectrometer, which features multiple Gas Elec- tron Multiplier (GEM) layers with large active area for high-precision tracking at very high rates. Simultaneous nucleon detection was performed by the Super BigBite spectrometer, which utilizes a dipole magnet with large solid angle acceptance at forward angles and a novel hadron calorimeter with very high and comparable detection efficiencies for both protons and neutrons. This setup could handle very high luminosity, making high-Q2 measurements feasible. Data were collected at five Q2 points: 3, 4.5, 7.4, 9.9, and 13.6 (GeV/c)2. Preliminary results are reported for all, with the lowest two Q2 points in good agreement with existing world data, while the higher points significantly extend the Q2 range in which Gn M is known accurately. The precision of the highest Q2 point is expected to remain unmatched for years to come.

Datta, Provakar↗