Search NASA⌕ Search

SEARCH · Search NASA

Results for “MAGNETIC RESONANCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Anvil cell gasket design for high pressure nuclear magnetic resonance experiments beyond 30 GPa

Nuclear magnetic resonance (NMR) experiments are reported at up to 30.5 GPa of pressure using radiofrequency (RF) micro-coils with anvil cell designs. These are the highest pressures ever reported with NMR, and are made possible through an improved gasket design based on nano-crystalline powders embedded in epoxy resin. Cubic boron-nitride (c-BN), corundum (α-Al{sub 2}O{sub 3}), or diamond based composites have been tested, also in NMR experiments. These composite gaskets lose about 1/2 of their initial height up to 30.5 GPa, allowing for larger sample quantities and preventing damages to the RF micro-coils compared to precipitation hardened CuBe gaskets. It is shown that NMR shift and resolution are less affected by the composite gaskets as compared to the more magnetic CuBe. The sensitivity can be as high as at normal pressure. The new, inexpensive, and simple to engineer gaskets are thus superior for NMR experiments at high pressures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The morphology of C–S–H: Lessons from {sup 1}H nuclear magnetic resonance relaxometry

{sup 1}H nuclear magnetic resonance has been applied to cement pastes, and in particular calcium silicate hydrate (C–S–H), for the characterisation of porosity and pore water interactions for over three decades. However, there is now renewed interest in the method, given that it has been shown to be non-invasive, non-destructive and fully quantitative. It is possible to make measurements of pore size distribution, specific surface area, C–S–H density and water fraction and water dynamics over 6 orders of magnitude from nano- to milli-seconds. This information comes in easily applied experiments that are increasingly well understood, on widely available equipment. This contribution describes the basic experiments for a cement audience new to the field and reviews three decades of work. It concludes with a summary of the current state of understanding of cement pore morphology from the perspective of {sup 1}H NMR.

36 MATERIALS SCIENCE↗

Effects of hydrogenation on non-radiative defects in GaNP and GaNAs alloys: An optically detected magnetic resonance study

Photoluminescence and optically detected magnetic resonance techniques are utilized to study defect properties of GaNP and GaNAs alloys subjected to post-growth hydrogenation by low-energy sub-threshold ion beam irradiation. It is found that in GaNP H incorporation leads to activation of new defects, which has a Ga interstitial (Ga{sub i}) atom at its core and may also involve a H atom as a partner. The observed activation critically depends on the presence of N in the alloy, as it does not occur in GaP with a low level of N doping. In sharp contrast, in GaNAs hydrogen is found to efficiently passivate Ga{sub i}-related defects present in the as-grown material. A possible mechanism responsible for the observed difference in the H behavior in GaNP and GaNAs is discussed.

36 MATERIALS SCIENCE↗

Effect of Gold Marker Seeds on Magnetic Resonance Spectroscopy of the Prostate

Purpose: Magnetic resonance stereoscopic imaging (MRSI) of the prostate is an emerging technique that may enhance targeting and assessment in radiotherapy. Current practices in radiotherapy invariably involve image guidance. Gold seed fiducial markers are often used to perform daily prostate localization. If MRSI is to be used in targeting prostate cancer and therapy assessment, the impact of gold seeds on MRSI must be investigated. The purpose of this study was to quantify the effects of gold seeds on the quality of MRSI data acquired in phantom experiments. Methods and Materials: A cylindrical plastic phantom with a spherical cavity 10 centimeters in diameter wss filled with water solution containing choline, creatine, and citrate. A gold seed fiducial marker was put near the center of the phantom mounted on a plastic stem. Spectra were acquired at 1.5 Tesla by use of a clinical MRSI sequence. The ratios of choline + creatine to citrate (CC/Ci) were compared in the presence and absence of gold seeds. Spectra in the vicinity of the gold seed were analyzed. Results: The maximum coefficient of variation of CC/Ci induced by the gold seed was found to be 10% in phantom experiments at 1.5 T. Conclusion: MRSI can be used in prostate radiotherapy in the presence of gold seed markers. Gold seeds cause small effects (in the order of the standard deviation) on the ratio of the metabolite's CC/Ci in the phantom study done on a 1.5-T scanner. It is expected that gold seed markers will have similar negligible effect on spectra from prostate patients. The maximum of 10% of variation in CC/Ci found in the phantom study also sets a limit on the threshold accuracy of CC/Ci values for deciding whether the tissue characterized by a local spectrum is considered malignant and whether it is a candidate for local boost in radiotherapy dose.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Operando nuclear magnetic resonance rotor insert

A magic angle sample spinning nuclear magnetic resonance system including a housing, a cryogenic fluid in the housing, a magnet in the housing, a probe in the housing, a magic angle sample spinning insert in the probe, a sample battery in the magic angle sample spinning insert, a photovoltaic cell in the magic angle sample spinning insert wherein the photovoltaic cell is connected to the sample battery, an optic fiber operatively connected to the photovoltaic cell, and a laser operatively connected to the optic fiber wherein the laser provides power to charge the sample battery during the magic angle sample spinning nuclear magnetic resonance.

Marple, Maxwell↗

A 4 K cryogenic probe for use in magnetic resonance force microscopy experiments

The detailed design of a mechanically detected nuclear magnetic resonance probe using the SPAM (Springiness Preservation by Aligning Magnetization) geometry, operating at 4 K, in vacuum, and a several-Tesla magnetic field is described. The probe head is vibration-isolated well enough from the environment by a three-spring suspension system that the cantilever achieves thermal equilibrium with the environment without the aid of eddy current damping. The probe uses an ultra-soft Si cantilever with a Ni sphere attached to its tip, and magnetic resonance is registered as a change in the resonant frequency of the driven cantilever. The RF system uses frequency sweeps for adiabatic rapid passage using a 500 μm diameter RF coil wound around a sapphire rod. The RF coil and optical fiber of the interferometer used to sense the cantilever's position are both located with respect to the cantilever using a Garbini micropositioner, and the sample stage is mounted on an Attocube nanopositioner.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Circularly polarized microwaves for magnetic resonance study in the GHz range: Application to nitrogen-vacancy in diamonds

The ability to create time-dependent magnetic fields of controlled polarization is essential for many experiments with magnetic resonance. We describe a microstrip circuit that allows us to generate strong magnetic field at microwave frequencies with arbitrary adjusted polarization. The circuit performance is demonstrated by applying it to an optically detected magnetic resonance and Rabi nutation experiments in nitrogen-vacancy color centers in diamond. Thanks to high efficiency of the proposed microstrip circuit and degree of circular polarization of 85%; it is possible to address the specific spin states of a diamond sample using a low power microwave generator. The circuit may be applied to a wide range of magnetic resonance experiments with a well-controlled polarization of microwaves.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James↗

Magnetic resonance imaging without field cycling at less than earth's magnetic field

A strong pre-polarization field, usually tenths of a milli-tesla in magnitude, is used to increase the signal-to-noise ratio in ordinary superconducting quantum interference device-based nuclear magnetic resonance/magnetic resonance imaging experiments. Here, we introduce an experimental approach using two techniques to remove the need for the pre-polarization field. A dynamic nuclear polarization (DNP) technique enables us to measure an enhanced resonance signal. In combination with a π/2 pulse to avoid the Bloch-Siegert effect in a micro-tesla field, we obtained an enhanced magnetic resonance image by using DNP technique with a 34.5 μT static external magnetic field without field cycling. In this approach, the problems of eddy current and flux trapping in the superconducting pickup coil, both due to the strong pre-polarization field, become negligible.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Design and evaluation of an open-source, conformable skin-cooling system for body magnetic resonance guided focused ultrasound treatments

Magnetic resonance guided focused ultrasound (MRgFUS) treatment of tumors uses inter-sonication delays to allow heat to dissipate from the skin and other near-field tissues. Despite inter-sonication delays, treatment of tumors close to the skin risks skin burns. This work has designed and evaluated an open-source, conformable, skin-cooling system for body MRgFUS treatments to reduce skin burns and enable ablation closer to the skin. A MR-compatible skin cooling system is described that features a conformable skin-cooling pad assembly with feedback control allowing continuous flow and pressure maintenance during the procedure. System performance was evaluated with hydrophone, phantom and in vivo porcine studies. Sonications were performed 10 and 5 mm from the skin surface under both control and forced convective skin-cooling conditions. 3D MR temperature imaging was acquired in real time and the accumulated thermal dose volume was measured. Gross analysis of the skin post-sonication was further performed. Device conformability was demonstrated at several body locations. Hydrophone studies demonstrated no beam aberration, but a 5–12% reduction of the peak pressure due to the presence of the skin-cooling pad assembly in the acoustic near field. Phantom evaluation demonstrated there is no MR temperature imaging precision reduction or any other artifacts present due to the coolant flow during MRgFUS sonication. The porcine studies demonstrated skin burns were reduced in size or eliminated when compared to the control condition. An open-source design of an MRgFUS active skin cooling system demonstrates device conformability with a reduction of skin burns while ablating superficial tissues.

60 APPLIED LIFE SCIENCES↗

Spin-flop transition on Gd5Ge4 observed by x-ray resonant magnetic scattering and first-principles calculations of magnetic anisotropy

X-ray resonant magnetic scattering was employed to study a fully reversible spin-flop transition in orthorhombic Gd{sub 5}Ge{sub 4} and to elucidate details of the magnetic structure in the spin-flop phase. The orientation of the moments at the three Gd sites flop 90{sup o} from the c axis to the a axis when a magnetic field, H{sub sf} = 9 kOe, is applied along the c axis at T = 9 K. The magnetic space group changes from Pnm'a to Pn'm'a' for all three Gd sublattices. The magnetic anisotropy energy determined from experimental measurements is in good agreement with the calculations of the magnetic anisotropy based on the spin-orbit coupling of the conduction electrons and an estimation of the dipolar interactions anisotropy. No significant magnetostriction effects were observed at the spin-flop transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Numerical Study of a Crossed Loop Coil Array for Parallel Magnetic Resonance Imaging

A coil design has been recently proposed by Temnikov (Instrum Exp Tech. 2005;48;636-637), with higher experimental signal-to-noise ratio than that of the birdcage coil. It is also claimed that it is possible to individually tune it with a single chip capacitor. This coil design shows a great resemble to the gradiometer coil. These results motivated us to numerically simulate a three-coil array for parallel magnetic resonance imaging and in vivo magnetic resonance spectroscopy with multi nuclear capability. The magnetic field was numerical simulated by solving Maxwell's equations with the finite element method. Uniformity profiles were calculated at the midsection for one single coil and showed a good agreement with the experimental data. Then, two more coils were added to form two different coil arrays: coil elements were equally distributed by an angle of a 30 deg. angle. Then, uniformity profiles were calculated again for all cases at the midsection. Despite the strong interaction among all coil elements, very good field uniformity can be achieved. These numerical results indicate that this coil array may be a good choice for magnetic resonance imaging parallel imaging.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Validation of Supervised Automated Algorithm for Fast Quantitative Evaluation of Organ Motion on Magnetic Resonance Imaging

Purpose: To validate a correlation coefficient template-matching algorithm applied to the supervised automated quantification of abdominal-pelvic organ motion captured on time-resolved magnetic resonance imaging. Methods and Materials: Magnetic resonance images of 21 patients across four anatomic sites were analyzed. Representative anatomic points of interest were chosen as surrogates for organ motion. The point of interest displacements across each image frame relative to baseline were quantified manually and through the use of a template-matching software tool, termed 'Motiontrack.' Automated and manually acquired displacement measures, as well as the standard deviation of intrafraction motion, were compared for each image frame and for each patient. Results: Discrepancies between the automated and manual displacements of {>=}2 mm were uncommon, ranging in frequency of 0-9.7% (liver and prostate, respectively). The standard deviations of intrafraction motion measured with each method correlated highly (r = 0.99). Considerable interpatient variability in organ motion was demonstrated by a wide range of standard deviations in the liver (1.4-7.5 mm), uterus (1.1-8.4 mm), and prostate gland (0.8-2.7 mm). The automated algorithm performed successfully in all patients but 1 and substantially improved efficiency compared with manual quantification techniques (5 min vs. 60-90 min). Conclusion: Supervised automated quantification of organ motion captured on magnetic resonance imaging using a correlation coefficient template-matching algorithm was efficient, accurate, and may play an important role in off-line adaptive approaches to intrafraction motion management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Grassy-ELM regime with edge resonant magnetic perturbations in fully noninductive plasmas in the DIII-D tokamak

Resonant magnetic perturbations (n=3 RMPs) are used to eliminate large amplitude ELMs and reduce the amplitude of weaker "grassy"-ELMs in DIII-D plasmas relevant to the ITER steady-state mission. Fully non-inductive discharges in the ITER shape and pedestal collisionality (n*e ≈ 0.05-0.15) are routinely achieved in DIII-D with RMP suppression of Type-I ELMs. The residual grassy-ELMs deliver a low peak heat flux to the divertor, within 50% of the inter-ELM heat flux, in plasmas with sustained high H-factor (H98y2≈1.2). These grassy-ELM plasmas have a pedestal width that is typically 10% of the poloidal minor radius and ≈50% wider than EPED model predictions. The operating window for RMP grassy-ELMs in edge magnetic safety factor and external torque is in the range required for a steady-state tokamak reactor, such as q95 between 5.3 and 7.1, and co-Ip neutral beam torque down to 0.7 Nm. Small amplitude RMPs (dBvac/B≈1.5x10-4) are sufficient to access this regime, consistent with the large amplification of the vacuum field by the plasma, typically 3-4x the amplification produced by ITER baseline plasmas due to the high pedestal pressure. Cyclic pulsations are observed in the pedestal and plasma magnetic response, consistent with theoretically predicted limit cycle behavior of magnetic island penetration and screening. The grassy ELMs are strongly modulated and sometimes fully suppressed during these pedestal pulsations, consistent with the stabilizing effect of resonant field penetration on peeling-ballooning mode stability. The use of low amplitude edge-resonant magnetic perturbations to access enhanced grassy-ELM operation in a naturally wide pedestal plasma with weak confinement degradation opens the possibility for further optimization of the steady-state tokamak by improved coupling between external fields and weakly stable modes of the plasma.

43 PARTICLE ACCELERATORS↗

Can magnetic resonance imaging differentiate among transurethral bulking agent, urethral diverticulum, and periurethral cyst?

Purpose: To evaluate magnetic resonance imaging findings that differentiate among periurethral bulking agents (primarily collagen), urethral diverticulum, and periurethral cyst. Methods: We searched our radiologic database retrospectively from 2001 to 2017 for periurethral cystic lesions, identifying a total of 50 patients with 68 lesions. Final diagnoses in 68 lesions were bulking agents (27), urethral diverticula (29), and periurethral cysts (12). Two abdominal radiologists, blinded to clinical history, independently evaluated T1, T2, and post-contrast images. The readers assessed number, morphological features, location, connection to urethra and mass effect, signal intensity, and enhancement for each lesion. Fisher exact test and logistic regression analysis were performed for each univariate significant feature. The operative and pathologic reports were the reference standard. Results: Magnetic resonance imaging features found more often in bulking agents versus urethral diverticulum were multiple lesions (P = 0.011), upper or upper-mid-urethral location (P ≤ 0.0001), lack of internal fluid/fluid level (P = 0.002), no urethral connection (P = 0.005), T1 isointensity, and T2 mild hyperintensity compared to muscles but lower T2 signal than urine (P < 0.0001). Most cases of urethral diverticula and periurethral cysts were detected at mid- and lower urethra. Urethral diverticula were larger than bulking agents and periurethral cysts (P = 0.005 and P = 0.023) (mean diameter = 24, 16, 15 mm, respectively). Most bulking agents (93%) and urethral diverticula (90%) showed mass effect on urethra, while periurethral cysts (75%) did not (P < 0.0001). Conclusion: Signal intensity and lesion characterization on magnetic resonance imaging can significantly differentiate bulking agent from urethral diverticulum and periurethral cyst. Radiologists should consider differential diagnosis of a bulking agent, especially when distinguishing characteristics described here are present to prevent incorrect diagnosis and ultimately unnecessary surgical intervention.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Characteristics of the Magnetic Resonance WPT System Applying a Frequency Converter

Recently, studies on the commercialization of magnetic resonance wireless power transfer (WPT) systems are underway domestically and internationally. The magnetic resonance WPT technology enables power transmission between transmitter and receiver coils with the same resonance frequency. If the resonance frequencies of the transmitter coil and receiver coil are different, the efficiency of the WPT will rapidly decrease. Various organizations, such as A4WP, have been striving to standardize resonance frequencies, but the countries around the world are sticking to their own distinctive standards based on the frequency bands available in their territories. Therefore, each country uses a slightly different resonance frequency band. In this paper, a frequency converter that enables WPT when the transmitter and receiver coils have different resonance frequencies is proposed. The frequency converter consists of two coils, and its structure is very simple. The two coils transmit power using the magnetic induction method, and frequency variation is possible using variable capacitors. It was confirmed from the experiment that WPT is possible even if the resonance frequencies of the transmitter and receiver coils are different.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Prospective, Multicenter Validation Study of Magnetic Resonance Volumetry for Response Assessment After Preoperative Chemoradiation in Rectal Cancer: Can the Results in the Literature be Reproduced?

Purpose: To review the available literature on tumor size/volume measurements on magnetic resonance imaging for response assessment after chemoradiotherapy, and validate these cut-offs in an independent multicenter patient cohort. Methods and Materials: The study included 2 parts. (1) Review of the literature: articles were included that assessed the accuracy of tumor size/volume measurements on magnetic resonance imaging for tumor response assessment. Size/volume cut-offs were extracted; (2) Multicenter validation: extracted cut-offs from the literature were tested in a multicenter cohort (n=146). Accuracies were calculated and compared with reported results from the literature. Results: The review included 14 articles, in which 3 different measurement methods were assessed: (1) tumor length; (2) 3-dimensonial tumor size; and (3) whole volume. Study outcomes consisted of (1) complete response (ypT0) versus residual tumor; (2) tumor regression grade 1 to 2 versus 3 to 5; and (3) T-downstaging (ypT<cT). In the multicenter cohort, best results were obtained for the validation of the whole-volume measurements, in particular for the outcome ypT0 (accuracy 44%-80%), with the optimal cut-offs being 1.6 cm{sup 3} (after chemoradiation therapy) and a volume reduction of Δ80% to 86.6%. Accuracies for whole-volume measurements to assess tumor regression grade 1 to 2 were 52% to 61%, and for T-downstaging 51% to 57%. Overall accuracies for tumor length ranged between 48% and 53% and for 3D size measurement between 52% and 56%. Conclusions: Magnetic resonance volumetry using whole-tumor volume measurements can be helpful in rectal cancer response assessment with selected cut-off values. Measurements of tumor length or 3-dimensional tumor size are not helpful. Magnetic resonance volumetry is mainly accurate to assess a complete tumor response (ypT0) after chemoradiation therapy (accuracies up to 80%).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Natural Products Magnetic Resonance Database (NP-MRD) for 2025

The Natural Products Magnetic Resonance Database or NP-MRD (https://np-mrd.org) is a comprehensive, freely accessible, web-based resource for the deposition, distribution, extraction and retrieval of nuclear magnetic resonance (NMR) data on natural products. The NP-MRD was initially established to support compound de-replication and data dissemination for the natural products community. However, that community has now grown to include many users from the metabolomics, microbiomics, foodomics and nutrition science fields. Indeed, since its launch in 2021, the NP-MRD has expanded enormously in size, scope and popularity. The current version of NP-MRD now contains nearly 7X more compounds (281,859 vs. 40,908) and 7X more NMR spectra (5.1 million vs. 817,000) than the first release. More specifically, an additional 4.6 million predicted spectra and another 11,000 spectra simulated from experimental chemical shifts were deposited into the database. Likewise, the number of NMR raw spectral data depositions has grown from a 165 spectra per year to more than 10,000 per year. As a result of this expansion, the number of monthly webpage views has grown from 55 to 20,000 and the number of monthly visitors has increased from 7 to 2500. To address this growth and to better support the expanding needs of its diverse community of users, many additional improvements to the NP-MRD have been made. These include significant enhancements to the data submission process, important improvements to the visualization and display of NMR spectra, notable updates to the database’s spectral search utilities and useful additions to support better NMR spectral analysis/prediction. Significant efforts have also been undertaken to remediate and update many of NP-MRD’s database entries. This manuscript describes these database improvements and expansion efforts, along with how they have been implemented and what future upgrades to the NP-MRD are planned.

Artifical Intelligence↗