Search NASA⌕ Search

SEARCH · Search NASA

Results for “MASS RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Visualization of High Resolution Spatial Mass Spectrometric Data during Acquisition

Mass Spectrometric Imaging (IMS) allows the generation of 2D ion density maps that help visualize molecules present in sections of tissues and cells. The combination of spatial and mass resolution results in large and complex data sets that require powerful and efficient analysis and interpretation. In this paper, a graphical user interface (GUI) that can visualize the large data during data acquisition itself is presented. The program also has the ability to perform processing and analysis of the dataset. The various functions of the GUI including visualization of mass spectra, generation of 2D maps for selected species, manipulation of the heat maps, and peak identification are also presented.

Thomas, Mathew↗

Ultra-High Resolution Elemental/Isotopic Mass Spectrometry (m/?m> 1,000,000): Coupling of the Liquid Sampling-Atmospheric Pressure Glow Discharge with an Orbitrap Mass Spectrometer for Applications in Biological Chemistry and Environmental Analysis

Many fundamental questions of astrophysics, biochemistry, and geology rely on the ability to accurately and precisely measure the mass and abundance of isotopes. Taken a step further, the capacity to perform such measurements on intact molecules provides insights into processes in diverse biological systems. Described here is the coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma, with a commercially available ThermoScientific Fusion Lumos mass spectrometer. Demonstrated for the first time is the ionization and isotopically-resolved fingerprinting of a long-postulated, but never mass-spectrometrically observed, bi-metallic complex Hg:Se-cysteine. Such a complex has been implicated as having a role in observations of Hg detoxification by selenoproteins/amino acids. Demonstrated as well is the ability to mass spectrometrically-resolve the geochronologically important isobaric 87Sr and 87Rb species (?m ~ 0.3 mDa, mass resolution m/?m ? 1,700,000). The mass difference in this case reflects the beta-decay of the 87Rb to the stable Sr isotope. These two demonstrations highlight what may be a significant change in bioinorganic and atomic mass spectrometry, with impact expected across a broad spectrum of the physical, biological and geological sciences.

Hoegg, Edward D.↗

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical System

High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗

Ion Mobility Spectrometry Characterization of the Intermediate Hydrogen-Containing Gold Cluster Au7(PPh3)7H52+

We employ ion mobility spectrometry and density functional theory to determine the structure of Au7(PPh3)7H52+ (PPh3 = triphenylphosphine) which was recently identified by high mass resolution mass spectrometry. Experimental ion-neutral collision cross sections represent the momentum transfer between the ionic clusters and gas molecules averaged over the relative thermal velocities of the colliding pair, thereby providing structural insights. Theoretical calculations indicate the geometry of Au7(PPh3)7H52+ is similar to Au7(PPh3)7+, with three hydrogen atoms bridging two gold atoms and two hydrogen atoms forming single Au–H bonds. Collision induced dissociation products observed during IMS experiments reveal that smaller hydrogen containing clusters may be produced through fragmentation of Au7(PPh3)7H52+. Our findings indicate that hydrogen containing species like Au7(PPh3)7H52+ act as intermediates in the formation of larger phosphine ligated gold clusters. These results advance the understanding and ability to control the mechanisms of size selective cluster formation which is necessary for scalable synthesis of clusters with tailored properties. This work was supported by the U.S. Department of Energy (DOE), Office of Science, Office of Basic Energy Sciences, Division of Chemical Sciences, Geosciences, and Biosciences. M.A.H. acknowledges support from the DOE Science Undergraduate Laboratory Internship (SULI) program. H.H. acknowledges support from the DOE Office of Workforce Development for Teachers and Scientist (WDTS) under the Visiting Faculty Program (VFP). The efforts of K.A.M. and B.H.C. were supported by the Defense Threat Reduction Agency (Grant No. HDTRA1-14-1-0023). The research was performed using EMSL, a national scientific user facility sponsored by the DOE’s Office of Biological and Environmental Research and located at Pacific Northwest National Laboratory (PNNL). PNNL is operated by Battelle for DOE under Contract DE-AC05-76RL01830.

Ligare, Marshall R.↗

Influence of counterion substitution on the properties of imidazolium-based ionic liquid clusters

Due to their unique physiochemical properties that may be tailored for specific purposes, ionic liquids (ILs) have been investigated for various applications, including chemical separations, catalysis, energy storage, and space propulsion. The different cations and anions comprising ILs may be selected to optimize a range of desired properties, such as thermal stability, ionic conductivity, and volatility, leading to the designation of certain ILs as designer “green” solvents. The effect of counterions on the properties of ILs is of both fundamental scientific interest and technological importance. Herein, we report a systematic experimental and theoretical investigation of the size, charge, stability toward dissociation, and geometric/electronic structure of 1-ethyl-3-methyl imidazolium (EMIM)-based IL clusters containing two different atomic counterions (i.e., bromide [Br − ] and iodide [I − ]). This work extends our studies of EMIM + cations with atomic chloride (Cl − ) and molecular tetrafluoroborate (BF 4 − ) anions reported previously by Baxter et al. [Chem. Mater. 34, 2612 (2022)] and Zhang et al . [J. Phys. Chem. Lett. 11, 6844 (2020)], respectively. Distributions of anionic IL clusters were generated in the gas phase using electrospray ionization and characterized by high mass resolution mass spectrometry, energy-resolved collision-induced dissociation, and negative ion photoelectron spectroscopy experiments. The experimental results reveal anion-dependent trends in the size distribution, relative abundance, ionic charge state, stability toward dissociation, and electron binding energies of the IL clusters. Complementary global optimization theory provides molecular-level insights into the bonding and electronic structure of a selected subset of clusters, including their low energy structures and electrostatic potential maps, and how these fundamental characteristics are influenced by anion substitution. Collectively, our findings demonstrate how the fundamental properties of ILs, which determine their suitability for many applications, may be tuned by substituting counterions. These observations are critical in the sub-nanometer cluster size regime where phenomena do not scale predictably to the bulk phase, and each atom counts toward determining behavior.

cluster↗

Coupling field and laboratory measurements to estimate the emission factors of identified and unidentified trace gases for prescribed fires

Vegetative fuels commonly consumed in prescribed fires were collected from five locations in the southeastern and southwestern U.S. and burned in a series of 77 fires at the U.S. Forest Service Fire Sciences Laboratory in Missoula, Montana. The particulate matter (PM2.5) emissions were measured by gravimetric filter sampling with subsequent analysis for elemental carbon (EC), organic carbon (OC), and 38 elements. The trace gas emissions were measured with a large suite of state-of-the-art instrumentation including an open-path Fourier transform infrared (OP FTIR) spectrometer, proton-transfer-reaction mass spectrometry (PTR-MS), proton-transfer ion-trap mass spectrometry (PIT-MS), negative-ion proton-transfer chemical-ionization mass spectrometry (NI-PT-CIMS), and gas chromatography with MS detection (GC-MS). 204 trace gas species (mostly non-methane organic compounds (NMOC)) were identified and quantified with the above instruments. An additional 152 significant peaks in the unit mass resolution mass spectra were quantified, but either could not be identified or most of the signal at that molecular mass was unaccounted for by identifiable species. As phase II of this study, we conducted airborne and ground-based sampling of the emissions from real prescribed fires mostly in the same land management units where the fuels for the lab fires were collected. A broad variety, but smaller number of species (21 trace gas species and PM2.5) was measured on 14 fires in chaparral and oak savanna in the southwestern US, as well as pine forest understory in the southeastern US and Sierra Nevada mountains of California. These extensive field measurements of emission factors (EF) for temperate biomass burning are useful both for modeling and to examine the representativeness of our lab fire EF. The lab/field EF ratio for the pine understory fuels was not statistically different from one, on average. However, our lab EF for “smoldering compounds” emitted by burning the semi-arid SW fuels should likely be increased by about a factor of 2.7 to better represent field fires. Based on the lab/field comparison, we present a table with emission factors for 365 pyrogenic species (including unidentified species) for 4 broad fuel types: pine understory, semi-arid shrublands, evergreen canopy, and duff. To our knowledge this is the most complete measurement of biomass burning emissions to date and it should enable improved representation of smoke in atmospheric models. The results provide important insights into the nature of smoke. For example, ~35% (range from 16-71%) of the mass of gas-phase NMOC species was attributed to the species that we could not identify. These unidentified species are likely not represented in most models, but some provision should be made for the fact that they will react in the atmosphere. In addition, the total mass of gas-phase NMOC divided by the mass of co-emitted PM2.5 averaged ~2.6 for the main fire types with a range from ~1.8-8.8. About 36-63% of the NMOC were likely semivolatile or of intermediate volatility. Thus, the gas-phase NMOC represent a large reservoir of potential precursors for secondary formation of organic aerosol. For the one fire in organic soil (Alaskan duff) about 28% of the emitted carbon was present as gas-phase NMOC in contrast to the other fuels for which NMOC accounted for only ~1-3% of emitted carbon. 71% of the mass of NMOC emitted by the smoldering duff was un-identified. The duff results highlight the need to learn more about the emissions from smoldering organic soils. The NMOC/“NOx-as-NO” ratio was consistently about ten for the main fire types when accounting for all NMOC, indicating strongly NOx-limited O3 production conditions. Finally, the fuel consumption per unit area was measured on 6 of the 14 prescribed fires and averaged 7.08 ± 2.09 (1) Mg ha-1.

Yokelson, R. J.↗

Studying the Formation, Evolution, and Habitability of the Galilean Satellites

Highly sensitive, high‐mass resolution mass spectrometry is an important in situ tool for the study of solar system bodies. In this talk we detail the science objectives, develop the rationale for the measurement requirements, and describe potential instrument/mission methodologies for studying the formation, evolution, and habitability of the Galilean satellites. We emphasize our studies of Ganymede and Europa as described in our instrument proposals for the recently selected JUICE mission and the proposed Europa Clipper mission.

McGrath, M.↗

SWICS/Ulysses and MASS/wind observations of solar wind sulfur charge states

As Ulysses journeys from the southern to the northern solar pole, the newly launched Wind spacecraft is monitoring the solar wind near 1 AU, slightly upstream of the Earth. Different solar wind structures pass over both spacecraft as coronal holes and other features rotate in and out of view. Ulysses and Wind are presently on opposing sides of the sun allowing us to monitor these streams for extended periods of time. Composition measurements made by instruments on both spacecraft provide information concerning the evolution and properties of these structures. We have combined data from the Solar Wind Ion Composition Spectrometer (SWICS) on Ulysses and the high mass resolution spectrometer (MASS) on Wind to determine the charge state distribution of sulfur in the solar wind. Both instruments employ electrostatic deflection with time-of-flight measurement. The high mass resolution of the MASS instrument (M/Delta-M approximately 100) allows sulfur to be isolated easily while the stepping energy/charge selection provides charge state information. SWICS measurements allow the unique identification of heavy ions by their mass and mass/charge with resolutions of M/Delta-M approximately 3 and M/q/Delta(M/q) approximately 20. The two instruments complement each other nicely in that MASS has the greater mass resolution while SWICS has the better mass/charge resolution and better statistics.

Cohen, C. M. S.↗

A high-throughput de novo sequencing approach for shotgun proteomics using high-resolution tandem mass spectrometry

High-resolution tandem mass spectra can now readily be acquired with hybrid instruments, such as LTQ-Orbitrap and LTQ-FT, in high-throughput shotgun proteomics workflows. In this study, a new de novo sequencing algorithm, Vonode, has been developed specifically for such high-resolution tandem mass spectra. To fully exploit the high mass accuracy, sparse noise, and low background of these spectra, a unique scoring system is used to evaluate sequence tags based mainly on mass accuracy information of fragment ions. Consensus sequence tags were inferred for 11,422 spectra with an average peptide length of 5.5 residues from a total of 40,297 input spectra acquired in a 24-hour proteomics measurement of Rhodopseudomonas palustris. The accuracy of inferred consensus sequence tags was 84%. The performance of Vonode was shown to be superior to the PepNovo v2.0 algorithm, especially in term of the number of de novo sequenced spectra.

59 BASIC BIOLOGICAL SCIENCES↗

Iron charge states in the solar wind as measured by SMS on Wind

The Wind spacecraft was launched in November 1994. In the first half of 1995 it was in the interplanetary medium upstream of the Earth. The Solar Wind and Suprathermal Ion Composition Experiment (SMS) on Wind consists of three sensors, the Solar Wind Ion Composition Spectrometer (SWICS), the Suprathermal Ion Composition Spectrometer (STICS), and the high mass resolution spectrometer (MASS). All three instruments utilize electrostatic deflection combined with time-of-flight measurement. The data from these three sensors allows the determination of the ionic composition of the solar wind in a variety of solar wind conditions over a large energy/charge range (0.5 to 230 keV/e). We have examined the Wind database for time periods conducive to observing solar wind iron. With the high mass resolution of the MASS spectrometer (M/Delta-M greater than 100) iron is easily identified while the electrostatic deflection provides information concerning the mass/charge distribution. We present here the relative abundance of iron charge states in the solar wind near 1 AU.

Galvin, A. B.↗

Resolution and Mass Range Performance in Distance-of-flight Mass Spectrometry with a Multichannel Focal-Plane Camera Detector.

Distance-of-flight mass spectrometry (DOFMS) is a velocity-based mass-separation technique in which ions are separated in space along the plane of a spatially selective detector. In the present work, a solid-state charge-detection array, the focal-plane camera (FPC), was incorporated into the DOFMS platform. Use of the FPC with our DOFMS instrument resulted in improvements in analytical performance, usability, and versatility over a previous generation instrument that employed a microchannel-plate/phosphor DOF detector. Notably, FPC detection provided resolution improvements of at least a factor of 2, with typical DOF linewidths of 300 μm (R((fwhm)) = 1000). The merits of solid-state detection for DOFMS are evaluated, and methods to extend the DOFMS mass range are considered.

Array Detection↗

Utilization of the LS-APGD microplasma/orbitrap-FTMS booster system for detection and isotopic analysis of neodymium nanoparticles

Detection and isotopic analysis of particle populations has seen rapid growth across several application areas, including environmental analysis, nuclear forensics, and food safety. The ability to characterize the particles' unique elemental and isotopic fingerprints could provide information related to formation, processing history, and transport. Regarding nuclear forensics, isotopic analysis of particles derived from diverse materials is often used as a tool to trace the origin and processing history. Mass spectrometric-based techniques currently used for particle population analysis often suffer from limited mass resolution, particularly when dealing with real-world samples that are affected by isobaric and polyatomic interferences from the matrix. To address these analytical challenges, we propose a novel method utilizing the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma ionization source coupled to an ultrahigh resolution Orbitrap mass spectrometer, further enhanced with the FTMS X2T Booster data acquisition and processing unit. The FTMS Booster enables acquisition of extended transient times of up to 3 s, significantly improving mass resolution, thereby reducing or even eliminating the need for prior separation of isobaric or polyatomic interferences. Additionally, the detection of low-abundance isotopes was improved by increasing the signal-to-noise (S/N) ratio. As proof of concept, this study demonstrates the feasibility of the LS-APGD/Orbitrap-FTMS X2T Booster platform for direct analysis using a suspension of well-characterized ∼120 nm neodymium particles. The quality of the isotope ratios values obtained from a few hundred particles were in good agreement with those obtained from homogeneous ionic solutions. These results highlight the potential of the LS-APGD/Orbitrap platform for rapid, accurate, and interference-resilient isotope ratio analysis of particle populations without the need for dissolution and subsequent chemical separations, offering significant advantages for nuclear forensics, safeguards, and environmental applications. The effort here also points to further paths forward, hopefully towards single particle (SP) analysis using microplasma ionization and the ultrahigh resolving power of the Orbitrap mass analyzer.

FTMS X2T booster↗

Mexico city aerosol analysis during MILAGRO using high resolution aerosol mass spectrometry at the urban supersite (T0) - Part 2: Analysis of the biomass burning contribution and the non-fossil carbon fraction

Submicron aerosol was analyzed during the MILAGRO field campaign in March 2006 at the T0 urban supersite in Mexico City with a High-Resolution Aerosol Mass Spectrometer (AMS) and complementary instrumentation. Positive Matrix Factorization (PMF) of high resolution AMS spectra identified a biomass burning organic aerosol (BBOA) component, which includes several large plumes that appear to be from forest fires within the region. Here, we show that the AMS BBOA concentration at T0 correlates with fire counts in the vicinity of Mexico City and that most of the BBOA variability is captured when the FLEXPART model is used for the dispersion of fire emissions as estimated from satellite fire counts. The resulting FLEXPART fire impact factor (FIF) correlates well with the observed BBOA, acetonitrile (CH3CN), levoglucosan, and potassium, indicating that wildfires in the region surrounding Mexico City are the dominant source of BBOA at T0 during MILAGRO. The impact of distant BB sources such as the Yucatan is small during this period. All fire tracers are correlated, with BBOA and levoglucosan showing little background, acetonitrile having a well-known tropospheric background of {approx}100-150 pptv, and PM2.5 potassium having a background of {approx}160 ng m3 (two-thirds of its average concentration), which does not appear to be related to BB sources. We define two high fire periods based on satellite fire counts and FLEXPART-predicted FIFs. We then compare these periods with a low fire period when the impact of regional fires is about a factor of 5 smaller. Fire tracers are very elevated in the high fire periods whereas tracers of urban pollution do not change between these periods. Dust is also elevated during the high BB period but this appears to be coincidental due to the drier conditions and not driven by direct dust emission from the fires. The AMS oxygenated organic aerosol (OA) factor (OOA, mostly secondary OA or SOA) does not show an increase during the fire periods or a correlation with fire counts, FLEXPART-predicted FIFs or fire tracers, indicating that it is dominated by urban and/or regional sources and not by the fires near the MCMA. A new 14C aerosol dataset is presented. Both this new and a previously published dataset of 14C analysis suggest a similar BBOA contribution as the AMS and chemical mass balance (CMB), resulting in 13% higher non-fossil carbon during the high vs. low regional fire periods. The new dataset has {approx}15% more fossil carbon on average than the previously published one, and possible reasons for this discrepancy are discussed. During the low regional fire period, 38% of organic carbon (OC) and 28% total carbon (TC) are from non-fossil sources, suggesting the importance of urban and regional non-fossil carbon sources other than the fires, such as food cooking and regional biogenic SOA. The ambient BBOA/CH3CN ratio is much higher in the afternoon when the wildfires are most intense than during the rest of the day. Also, there are large differences in the contributions of the different OA components to the surface concentrations vs. the integrated column amounts. Both facts may explain some apparent disagreements between BB impacts estimated from afternoon aircraft flights vs. those from 24-h ground measurements. We show that by properly accounting for the non-BB sources of K, all of the BB PM estimates from MILAGRO can be reconciled. Overall, the fires from the region near the MCMA are estimated to contribute 15-23% of the OA and 7-9% of the fine PM at T0 during MILAGRO, and 2-3% of the fine PM as an annual average. The 2006 MCMA emissions inventory contains a substantially lower impact of the forest fire emissions, although a fraction of these emissions occur just outside of the MCMA inventory area.

09 BIOMASS FUELS↗