Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEA PROCESS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

ION Advanced Solvent CO 2 Capture Pilot Project

This final report to DOE/NETL presents all the work and tests performed during ION Engineering’s (ION) carbon dioxide (CO 2 ) capture pilot test campaign: “ION Advanced Solvent CO 2 Capture Project”. This project is comprised of three budget periods (BP): BP1 – Design of a 0.6 MWe system, BP2 – 0.5 MWe National Carbon Capture Center (NCCC) Testing Campaign, and BP3 – 12 MWe Technology Center at Mongstad (TCM) Testing Campaign. The program began in October 2013 and continued until December 2017. The campaign at NCCC, which took place from June to August of 2015, resulted in 1,116 operational hours where ~350 tonnes of CO 2 were captured from the 0.5 MWe coal-fired flue gas slipstream. The follow-up campaign at TCM took place from Oct 2016 to April 2017, where 2,775 hours of operation resulted in the capture of 14,820 tonnes of CO 2 , which is a cumulative of capturing CO 2 from the natural gas-fired Combined Heat and Power (CHP) plant, and a residue fluid catalytic cracker gas (RFCC) from Statoil at Mongstad. ION has conducted a thoughtful, comprehensive, and successful program in close collaboration with all its partners. CO 2 was successfully removed and captured for extended periods of time using three gas sources (NCCC Coal-fired Power plant, TCM CHP flue gas with and without CO 2 recycle, and TCM RFCC flue gas with air dilution) at various slipstream flows ranging from 0.5 MWe to 12 MWe. The data gathered on its solvent continues to strengthen the development of ION’s advanced solvent and positive track record in executing on-site test campaigns in highly industrialized settings. These existing pilot plants do not include the necessary process modifications that ION requires to obtain the lowest possible regeneration energy; processes such as a cold-rich bypass and intercooling, would allow for lowering the demonstrated specific reboiler duty. The resulting data was also used to validate the process model, and, in the absence of testing on a custom test rig specifically designed for ION’s advanced solvent, the results of the process model have shown specific reboiler duties under 2.5 MJ/kg CO 2 (1075 BTU/lb CO 2 ). When these regeneration energies are factored into the Techno-Economic Analysis (TEA), where ION’s technology is compared to the DOE/NETL BBS Case 12, which integrates a highly optimized and commercially available CO 2 capture technology, ION’s technology shows: 38% incremental reduction in capital cost of CO 2 capture; 28% incremental reduction in annual operating and maintenance costs of CO 2 capture; and $35-44 per tonne of CO 2 capture, which is a 20% to 40% reduction in cost of CO 2 capture. Throughout pilot testing, ION has confirmed its understanding of process improvements and analytics that will enable successful operation of its advanced solvent at significantly lower L/G circulation rates, packing heights and regeneration energies than MEA. ION has identified routes to further develop its technology and is looking forward to testing a fully optimized solvent and capture system in the near future.

01 COAL, LIGNITE, AND PEAT↗

Ionic Liquids: Breakthrough Absorption Technology for Post-Combustion CO 2 Capture

This is the final report for DE-FC26-07NT43091 Ionic Liquids: Breakthrough Absorption Technology for Post-Combustion CO 2 Capture. A detailed summary is provided of the ionic liquid (IL) discovery process, synthesis and testing results, process / systems modeling, lab-scale operational testing, corrosion testing and commercialization possibilities. The work resulted in the discovery of a new class of ionic liquids (ILs) that efficiently react with CO 2 in a 1:1 stoichiometry with no water present and no increase in viscosity. The enthalpy of reaction was tuned to optimize process economics. The IL was found to have excellent corrosion behavior with and without CO 2 present. In lab-scale tests, the IL was able to effectively remove CO 2 from a simulated flue gas stream, although mass transfer was slower than with aqueous monoethanolamine (MEA) due to higher viscosities. The non-volatile nature of the solvent and its high thermal stability, however, make it an intriguing option. An independent systems analysis indicates that the economics of using the best IL discovered to date (NDIL0157), are at least comparable to and potentially slightly better than - the Fluor Econamine FG PlusTM process (DOE Case 12). Further work should be directed at improving mass transfer / lowering viscosity and developing commercial synthesis routes to make these ILs at scale in an inexpensive manner. Demonstration of the process at larger scales is also warranted, as is the exploration of other process configurations that leverage the anhydrous nature of the solvent and its extremely low volatility.

54 ENVIRONMENTAL SCIENCES↗

Bench Scale Development and Testing of Aerogel Sorbents for CO 2 Capture Final Technical Report

The primary objective of this project was scaling up and evaluating a novel Amine Functionalized Aerogel (AFA) sorbent in a bench scale fluidized bed reactor. The project team (Aspen Aerogels, University of Akron, ADA-ES, and Longtail Consulting) has carried out numerous tests and optimization studies to demonstrate the CO 2 capture performance of the AFA sorbent in all its forms: powder, pellet, and bead. The CO 2 capture target performance of the AFA sorbent (all forms) were set at > 12 wt.% and > 6 wt.% for total and working CO 2 capacity, respectively (@ 40 °C adsorption / 100 – 120 °C desorption). The optimized AFA powders outperformed the performance targets by more than 30%, for the total CO 2 capacity (14 - 20 wt.%), and an average of 10 % more for working CO 2 capacity (6.6 – 7.0 wt.%, and could be as high as 9.6 wt. % when desorbed at 120 °C). The University of Akron developed binder formulations, pellet production methods, and post treatment technology for increased resistance to attrition and flue gas contaminants. In pellet form the AFA total CO 2 capacity was ~ 12 wt.% (over 85% capacity retention of that of the powder), and there was less than 13% degradation in CO 2 capture capacity after 20 cycles in the presence of 40 ppm SO 2 . ADA-ES assessed the performance of the AFA powder, pellet, and bead by analyzing sorption isotherms, water uptake analysis, cycling stability, jet cup attrition and crush tests. At bench scale, the hydrodynamic and heat transfer properties of the AFA sorbent pellet in fluidized bed conditions were evaluated at Particulate Solid Research, Inc. (PSRI). After the process design requirements were completed, by Longtail Consulting LLC, a techno-economic analysis was achieved using guidance from The National Energy Technology Laboratory (NETL) report. This report provides the necessary framework to estimate costs for a temperature swing post combustion CO 2 capture process using a bituminous coal fired, super-critical steam cycle power plant producing 550 MWe net generation with 90% CO 2 capture using a methylethylamine (MEA) solvent. Using the NETL report as guidance, the designed CO 2 capture system was analyzed on a cost basis to determine relative cost estimates between the benchmark MEA system and the AFA sorbent system.

20 FOSSIL-FUELED POWER PLANTS↗

Fuel Cell Manufacturing Diagnostic Techniques: IR Thermography with Reactive Flow through Excitation

While design and material considerations for PEMFCs have a large impact on cost, it is also necessary to consider a transition to high volume production of fuel cell systems, including MEA components, to enable economies of scale and reduce per unit cost. One of the critical manufacturing tasks is developing and deploying techniques to provide in‐process measurement of fuel cell components for quality control. This effort requires a subsidiary task: The study of the effect of manufacturing defects on performance and durability with the objective to establish validated manufacturing tolerances for fuel cell components. This work focuses on the development of a potential quality control method for gas diffusion electrodes (GDEs). The method consists of infrared (IR) thermography combined with reactive flow through (RFT) excitation. Detection of catalyst loading reduction defects in GDE catalyst layers will be presented.

30 DIRECT ENERGY CONVERSION↗

First Measurement of Differential Charged Current Quasielastic–like $\nu_\mu$ -Argon Scattering Cross Sections with the MicroBooNE Detector

Current and future generation neutrino oscillation experiments aim towards a high-precision mea- surement of the oscillation parameters and that requires an unprecedented understanding of neutrino-nucleus scattering. Charged-current quasi-elastic (CCQE) scattering is the process in which the neutrino produces a charged lepton and removes a single intact nucleon from the nu- cleus without producing any additional particles. For existing and forthcoming accelerator–based neutrino experiments, CCQE interactions are either the dominant process or part of the signal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Impact of Interposer Microstructure on Ionic Transport in Liquid-Phase Bicarbonate Electrolysis

The electrochemical reduction of CO 2 (CO 2 RR) is a potentially scalable approach for converting captured carbon dioxide into value-added products. Conventional gas-phase electrolysis systems can suffer from carbonate crossover, which limits the efficiency of the system. Liquid-phase (bi)carbonate electrolysis using bipolar membrane electrode assemblies (BPMMEA) has emerged as a promising alternative. The interposer layer, a porous mass-transport material between the BPM and the catalyst, is an essential component of the MEA, as it allows evolved CO 2 to reach the catalyst surface for reaction. In the absence of this layer, evolved CO 2 generated by the pH swing process at the BPM can be converted back into (bi)carbonate (CO 2 recapture) due to the high bulk pH. Thus, clear design guidelines are needed to maximize CO 2 conversion, minimize CO 2 recapture in the catholyte, and improve energy efficiency. Here, the transport properties of the interposer are systematically characterized by X-ray tomography and symmetric-cell impedance spectroscopy to quantify porosity, tortuosity, and the resulting MacMullin number. We then examine the correlation between these material properties and the electrolyzer performance. We focus on characterizing two commercial porous membrane filters, mixed cellulose ester (MCE) and poly(ether sulfone) (PES).

CO2 electrolysis↗

Evaluation of Carbon Dioxide Capture From Existing Coal Fired Plants by Hybrid Sorption Using Solid Sorbents

A novel hybrid solid sorbent technology for CO₂ capture and separation from coal combustion-derived flue gas was evaluated. The technology – Capture of CO₂ by Hybrid Sorption (CACHYS™) – is a solid sorbent technology based on the following ideas: 1) reduction of energy for sorbent regeneration, 2) utilization of novel process chemistry, 3) contactor conditions that minimize sorbent-CO₂ heat of reaction and promote fast CO₂ capture, and 4) low-cost method of heat management. This report provides key information developed during the course of the project that includes sorbent performance, energy for sorbent regeneration, physical properties of the sorbent, the integration of process components, sizing of equipment, and overall capital and operational cost of the integrated CACHYS™ system. Seven sorbent formulations were prepared and evaluated at the lab-scale for energy requirements and CO₂ capture performance. Sorbent heat of regeneration ranged from 30-80 kJ/mol CO₂ and was found to be dependent on process conditions. Two sorbent formulations (designated HCK-4 & HCK-7) were down-selected for additional fixed-bed testing. Additional testing involved subjecting the sorbents to 100 continuous cycles in the fixed-bed reactor to determine performance as a function of time. The working capacity achieved for HCK-4 sorbent ranged from 5.5-8.0 g CO₂/100 g sorbent, while the HCK-7 typically ranged from 8.0-10.0 g CO₂/100 g sorbent. Overall, there was no deterioration in capacity with continuous cycling for either sorbent. The CACHYS™ bench-scale testing system designed and fabricated under this award consists of a dual circulating fluidized-bed adsorber and a moving-bed regenerator. The system takes a flue gas slipstream from the University of North Dakota’s coal-fired steam plant. Prior to being sent to the adsorber, the flue gas is scrubbed to remove SO₂ and particulate. During parametric testing of the adsorber, CO₂ capture achieved using the 2-bed configuration with recirculation in both beds was 65-70% with a high flue gas CO₂ loading (~7%) and up to 85% with a low flue gas CO₂ loading (~4%). A sorbent regenerator system consisting of a pre-heater, desorber, and cooler is used to heat the CO₂-rich sorbent with direct and indirect steam producing a nearly 100% pure stream of CO₂. Parametric testing of the regenerator system demonstrated the impact of process conditions on both desorption rate and the heat of regeneration. Clear evidence of the use of specific process conditions that lower the overall energy of desorption was identified. This observation validates measurements made at the laboratory-scale. Several longer-term continuous tests were conducted to evaluate the performance of the sorbent/process as a function of time. Using a 2-bed configuration, sustained capture efficiency of 40-60% with a high flue gas CO₂ loading (~8%) and 70-80% with a low flue gas CO₂ loading (~4%) were achieved. However, sorbent working capacity was found to be considerably lower than laboratory-scale measurements. The low working capacity is attributed to insufficient sorbent/gas contact time in the adsorber. Sorbent properties that had a significant impact on CO₂ capture performance were identified. The results show that controlling these sorbent properties substantially improves CO₂ capture performance, with preliminary estimates indicating that relative improvement of ~30% is possible. Testing culminated with an operationally trouble-free test of 15 hours with sustainable performance. Overall, several practical strategies to increase performance of the sorbent and process were identified. The initial technical and economic assessment of the CACHYS™ process estimated the cost of CO2 capture was $36.19/ton with a 48.6% increase in levelized cost of electricity (LCOE) for the 550 MWe net plant. Using additional data gathered over the course of the project, and with revised technical and economic assumptions, the estimated cost of CO₂ capture with the CACHYS™ process is $39/ton (only includes the cost of the CO2 capture system) with an increase in LCOE of 55.9%. Overall, CACHYS™ represents a significant improvement over the benchmark MEA system, and has demonstrated progress towards achieving DOE’s goals for CO₂ capture technologies.

01 COAL, LIGNITE, AND PEAT↗

Quantifying Uncertainty in High CO₂ Capture rate with MEA Solvent Systems

This presentation covers the methodology and key findings from an uncertainty quantification study of monoethanolamine (MEA) solvent-based systems operating under high CO₂ capture conditions. The goal is to identify critical operational parameters, assess their impact on system performance, and provide insights to support risk-informed design and optimization of carbon capture processes.

monoethanolamine (MEA)↗

Examining the Reactions of Ethanolamine’s Thermal Degradation Compounds in Carbon Capture through 1 H NMR and 13 C NMR

In amine scrubbing carbon capture, concerns about amine solvent degradation include whether it can affect the ability of the solvent to capture CO 2 . This study examines the interactions between the three most reported monoethanolamine (MEA) thermal degradation compounds namely, oxazolidine-2-one (OZD), N-(2-hydroxyethyl)-ethylenediamine (HEEDA), and N-(2- hydroxyethyl)-imidazoline-2-one (HEIA) with CO 2 in the presence and absence of MEA. We compared 1 H NMR, 13 C NMR, and heteronuclear single-quantum coherence (HSQC) NMR for neat OZD, HEEDA, and HEIA samples with CO 2 -loaded samples to observe changes in protonation and unique carbamate species formation. We found that OZD and HEIA did not directly react with CO 2 or undergo proton shifting based on our comparison of the neat OZD and HEIA samples with CO 2 -loaded spectra. However, we observed that the OZD can protonate when sparged with CO 2 in the presence of MEA, which suggests that the OZD acts as an intermediate. The NMR spectra for HEEDA indicated that HEEDA directly reacts with CO 2 at both amino groups and can protonate. In the presence of MEA, HEEDA and MEA can act like a solvent blend, resulting in multiple carbamates forming within the solvent. The neat HEIA spectrum, compared with CO 2 -loaded HEIA spectra, revealed similar results as OZD, where it does not react with CO 2 or protonate directly. However, HEIA does not protonate in the presence of MEA. These degradation compound reactions can increase the number of general equilibrium reactions during carbon capture and impact the model MEA solvent. This work helps provide a more complete picture of the reactions as the solvent degrades. Although this study examines CO 2 effects on thermal degradation products for MEA, other amines such as piperazine or 1- amino-3-propanol will degrade, and the degradation may speciate similarly with CO 2 . Furthermore, this study can impact and improve process models by assessing the degradation compounds’ reactions with CO 2 and potentially incorporating them into the model based on a neat solvent.

20 FOSSIL-FUELED POWER PLANTS↗

Jacobian-based Model Diagnostics and Application to Equation Oriented Modeling of a Carbon Capture System

Equation-oriented (EO) modeling has the potential to enable the effective design and optimization of the operation of advanced energy systems. However, advanced modeling of energy systems results in a large number of variables and non-linear equations, and it can be difficult to search through these to identify the culprit(s) responsible for convergence issues. The Institute for the Design of Advanced Energy Systems Integrated Platform (IDAES-IP) contains a tool to identify poorly scaled constraints and variables by searching for rows and columns of the Jacobian matrix with small L2-norms so they can be rescaled. A further singular value decomposition can be per-formed to identify degenerate sets of equations and remaining scaling issues. This work presents an EO model of a flowsheet developed for post-combustion carbon capture using a monoethanolamine (MEA) solvent system as a case study. The IDAES diagnostics tools were successfully applied to this flowsheet to identify problems to improve model robustness and enable the optimization of process design and operating conditions of a carbon capture system.

Allan, Douglas↗

Low-Cost Proton Conducting Membranes for PEM Fuel Cells

Proton exchange membrane (PEM) is the key component in PEM fuel cells that critically determines the system performance and its economic viability. Presently, the state-of-the-art PEMs, such as Nafion membranes, are based on perfluorosulfonic acid (PFSA) ionomers. But these ionomer materials are expensive, particularly at the low volumes that will be needed for initial commercialization. Besides, they are not suitable for fuel cells operated beyond 100°C, because of the limitations connected to the humidification requirement of such membrane materials, limiting the maximum operating temperature to about 90°C. Fuel cells for transportation applications are required to operate in a wide temperature range from –20°C to 120°C. Low-cost PEMs with capabilities in a range of temperature and humidity conditions are urgently needed to meet the DOE fuel cell targets for transportation applications. Amsen Technologies LLC chooses to address the DOE call with a novel reinforced PEM approach based on new, non-PFSA proton conducting ionomers developed from our previous DOE SBIR projects. Along with this approach is the use of very cheap, ultra thin and highly porous microporous polymer meshes as the support for the membrane. The new PEM is expected to have significant cost advantages over traditional PEMs. The microporous polyolefin support costs $2-3/m 2 ; and the new ionomers that Amsen has developed are estimated at ~$\$$250/kg at the higher end including material costs and labor costs (which may go down in the future as the processing is optimized and production scaled up). These have led to an estimate of total material cost for the membrane at $\$$11 to $\$$12/m 2 , offering high potential of meeting the DOE cost targets (≤$\$$20/m 2 ) after adding processing cost and profit margin. The Phase I results have successfully demonstrated that it is very promising to develop the intended low-cost, high-performance PEM membrane. Suitable material system has been identified, and suitable process for forming the new PEM has been developed. Uniform membranes have been reproducibly fabricated. These membranes have been extensively characterized and evaluated in terms of microstructural features, and relevant physical and chemical properties including proton conductivity and area specific proton resistance in a range of temperature and humidity conditions, resistance to electronic conduction, water uptake/swelling, dimensional stability, chemical stability, and mechanical durability. Membrane electrode assemblies (MEA) with the new membrane have been successfully prepared and tested for fuel cell operation. The new PEM showed higher proton conductivity than Nafion membranes for all measurement conditions used in Phase I. With high proton conductivity and ultra-thin thickness (~20 /m), the new membrane showed high promise to met DOE targets for the low ASR. The ASR targets have been met for relatively high RH but not yet for RH ≤ 70%. Further optimization in ionomer chemistry and membrane processing is needed in order to meet the ASR targets for a wide range of temperature and humidity conditions. The new membrane showed fairly high electronic resistance at 1373 ohm cm 2 , meeting the DOE target for electronic resistance (> 1000 ohm cm 2 ). The new membrane also has demonstrated promisingly high chemical stability, high mechanical durability, and high dimensional stability. Fuel cell operation using MEAs with the new membrane have shown the same level of fuel cell performance as MEAs with Nafion membranes. Overall, the new membrane has been demonstrated to have high potential of meeting all DOE performance targets for fuel cell applications as well as the cost targets. The manufacturers of PEM fuel cells, PEM electrolyzers, redox flow batteries, and MEA are the end-users and customers of PEMs. For commercialization purpose and potential partnering relations, we have been talking with many such manufacturers. They have responded with extremely high interest in the new PEM being developed in the present technology. Accomplishments so far have laid down a strong base for Amsen to further the development efforts on this new PEM and to pursue commercialization. The near-term future work will be mainly focused on further development and systematical optimization of the material system, processing, and performance of the new membrane; systematical evaluation of the new membrane in terms of all relevant properties including long-term mechanical, chemical, and combined chemical/mechanical durabilities using DOE specified testing protocols; development of production scale-up scheme; and preparation for commercialization.

08 HYDROGEN↗

Constructing Highly Durable Fuel Cell Catalysts Through Integrating Graphitic Shell‐Protected Composite Carbon Support with Gaseous Co Deposition‐Driven PtCo Intermetallics

Metal dissolution, nanoparticle agglomeration, and carbon support corrosion cause significant performance degradation of current PtCo catalysts under acidic and oxidative oxygen reduction reaction. Here, in this study, an integrated strategy is presented to design high-performance Pt 3 Co intermetallic catalysts by regulating gaseous Co deposition-driven diffusion into Pt nanoparticles supported on a composite carbon. The composite carbon is derived from ZIF-8/polyaniline, consisting of a high-surface-area (HSC) core and a protective graphitic shell (GS), which is employed to design 40 wt.% Pt/HSC@GS catalyst. The corresponding membrane electrode assemblies (MEAs) can maintain 1.09 A cm −2 at 0.7 V (20. 7% loss) after 10 000 cycles (1.0–1.5 V for carbon stability) and 1.15 A cm −2 (16.1% loss) after 150 000 cycles (0.60–0.95 V for catalyst stability). A ordered Pt 3 Co intermetallic is synthesized via a gaseous Co-deposition process, which yields a homogeneous Co-rich layer onto the Pt nanoparticles on the composite support, thereby facilitating Co diffusion into Pt crystal during subsequent ordering annealing to form the ordered intermetallic structure. This gaseous deposition leads to a thin carbon layer on PtCo nanoparticles, inhibiting particle growth during the annealing and mitigating Co dissolution under dynamic electrochemical conditions. The PtCo catalyst achieves impressive MEA performance and long-term durability (1.45 A cm −2 at 0.7 V after 120 000 cycles) under heavy-duty conditions.

30 DIRECT ENERGY CONVERSION↗

PRELIMINARY TECHNICAL AND ECONOMIC FEASIBILITY STUDY ON THE INTEGRATION OF A PROCESS UTILIZING LOW-ENERGY SOLVENTS FOR CARBON DIOXIDE CAPTURE ENABLED BY A COMBINATION OF ENZYMES AND ULTRASONICS WITH A SUBCRITICAL PC POWER PLANT

The results of the preliminary techno-economic assessment for integrating a process utilizing low-energy solvents for carbon dioxide (CO2) capture enabled by a combination of enzymes and ultrasonics with a subcritical pulverized coal (PC) power plant are presented. Four cases utilizing the enzyme-activated solvent are compared using different methodologies of regeneration against the DOE/NETL reference MEA case. The results are shown comparing the energy demand for post-combustion CO2 capture and the net higher heating value (HHV) efficiency of the power plant integrated with the post-combustion capture (PCC) plant. A levelized cost of electricity (LCOE) assessment was performed showing the costs of the options presented in the study. The key factors contributing to the reduction of LCOE were identified as enzyme make-up rate and the capability of the ultrasonic regeneration process. The net efficiency of the integrated PC power plant with CO2 capture changes from 24.9% with the reference Case 10 plant to between 24.34% and 29.97% for the vacuum regeneration options considered, and to between 26.63% and 31.41% for the ultrasonic regeneration options. The evaluation also shows the effect of the critical parameters on the LCOE, with the main variable being the initial estimation of enzyme dosing rate. The LCOE ($/MWh) values range from 112.92 to 125.23 for the vacuum regeneration options and from 108.9 to 117.50 for the ultrasonic regeneration cases considered in comparison to 119.6 for the reference Case 10. A sensitivity analysis of the effect of critical parameters on the LCOE was also performed. The results from the preliminary techno-economic assessment show that the proposed technology can be investigated further with a view to being a viable alternative to conventional CO2 scrubbing technologies.

Swaminathan, Saravanan↗

Elucidation of Fe-N-C electrocatalyst active site functionality via in-situ X-ray absorption and operando determination of oxygen reduction reaction kinetics in a PEFC

In the past decade the notable effort placed on improving intrinsic electrochemical kinetics of platinum group metal (PGM)-free electrocatalysts for the oxygen reduction reaction (ORR) has led to a significant improvement in both performance and understanding of this class of electrocatalysts. However, a limited amount of this development and understanding has been undertaken using operando electrochemical diagnostics at the membrane electrode assembly (MEA) level. In this work, the operando ORR kinetics on an atomically dispersed iron-nitrogen-carbon ((AD)Fe-N-C) PGM-free electrocatalyst have been examined to extract the reaction order and the activation energy of the ORR. The experiments were carefully designed to ensure the stability/predictability of the electrocatalyst during the data collection process and thus validate the relevance of the values obtained for the aforementioned parameters. A kinetic model that considers a potential-dependent availability of active sites (θ) is proposed. Active site availability is shown to be a function of both the change in the oxidation state (nR) and the redox potential at which the metal center transitions from a higher oxidation state to a lower one (). The resulting model fitting parameters for nR and (0.71 and 0.788 V, respectively) obtained from the analysis of operando data correlate well with those from in situ X-ray absorption near edge structure measurements (nR=0.57) and in situ cyclic voltammetry measurements (0.75 V < <0.8 V) in the MEA environment. The resulting model provides an excellent fit of MEA performance across the range of pressures, temperatures, and potentials under which the data were collected.

Activation energy↗

Final Techno-Economic Analysis of 550 MWe Supercritical PC Power Plant CO 2 Capture with Linde-BASF Advanced PCC Technology

This topical report presents the techno-economic evaluation of a 550 MWe supercritical pulverized coal (PC) power plant utilizing Illinois No. 6 coal as fuel, integrated with 1) a previously presented (for a subcritical PC plant) Linde-BASF post-combustion CO 2 capture (PCC) plant incorporating BASF’s OASE® blue aqueous amine-based solvent (LB1) [Ref. 6] and 2) a new Linde-BASF PCC plant incorporating the same BASF OASE® blue solvent that features an advanced stripper interstage heater design (SIH) to optimize heat recovery in the PCC process. The process simulation and modeling for this report is performed using Aspen Plus V8.8. Technical information from the PCC plant is determined using BASF’s proprietary thermodynamic and process simulation models. The simulations developed and resulting cost estimates are first validated by reproducing the results of DOE/NETL Case 12 representing a 550 MWe supercritical PC-fired power plant with PCC incorporating a monoethanolamine (MEA) solvent as used in the DOE/NETL Case 12 reference [Ref. 2]. The results of the techno-economic assessment are shown comparing two specific options utilizing the BASF OASE® blue solvent technology (LB1 and SIH) to the DOE/NETL Case 12 reference. The results are shown comparing the energy demand for PCC, the incremental fuel requirement, and the net higher heating value (HHV) efficiency of the PC power plant integrated with the PCC plant. A comparison of the capital costs for each PCC plant configuration corresponding to a net 550 MWe power generation is also presented. Lastly, a cost of electricity (COE) and cost of CO 2 captured assessment is shown illustrating the substantial cost reductions achieved with the Linde-BASF PCC plant utilizing the advanced SIH configuration in combination with BASF’s OASE® blue solvent technology as compared to the DOE/NETL Case 12 reference. The key factors contributing to the reduction of COE and the cost of CO 2 captured, along with quantification of the magnitude of the reductions achieved by each of these factors, are also discussed. Additionally, a high-level techno-economic analysis of one more highly advanced Linde-BASF PCC configuration case (LB1-CREB) is also presented to demonstrate the significant impact of innovative PCC plant process design improvements on further reducing COE and cost of CO 2 captured for overall plant cost and performance comparison purposes. Overall, the net efficiency of the integrated 550 MWe supercritical PC power plant with CO 2 capture is increased from 28.4% with the DOE/NETL Case 12 reference to 30.9% with the Linde-BASF PCC plant previously presented utilizing the BASF OASE® blue solvent [Ref. 6], and is further increased to 31.4% using Linde-BASF PCC plant with BASF OASE® blue solvent and an advanced SIH configuration. The Linde-BASF PCC plant incorporating the BASF OASE® blue solvent also results in significantly lower overall capital costs, thereby reducing the COE and cost of CO 2 captured from $147.25/MWh and $56.49/MT CO 2 , respectively, for the reference DOE/NETL Case 12 plant, to $128.49/MWh and $41.85/MT CO 2 for process case LB1, respectively, and $126.65/MWh and $40.66/MT CO 2 for process case SIH, respectively. With additional innovative Linde-BASF PCC process configuration improvements, the COE and cost of CO2 captured can be further reduced to $125.51/MWh and $39.90/MT CO 2 for LB1-CREB. Most notably, the Linde-BASF process options presented here have already demonstrated the potential to lower the cost of CO2 captured below the DOE target of $40/MT CO 2 at the 550 MWe scale for second generation PCC technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Porous transport electrodes for oxygen evolution reaction in proton exchange membrane water electrolysis -cells: Materials, designs, and diagnoses

H 2 production using proton exchange membrane (PEM) water electrolysis (PEMWE) cells has received considerable attention because of the high efficiencies of these cells and no harmful emissions from the related process. In PEMWE cells, porous transport electrodes (PTEs) composed of a catalyst layer (CL) comprising O 2 evolution reaction (OER) catalysts, porous transport layer (PTL), and PEM play key roles in the stack performance and lifetime. Herein, Ir-based and non-precious-metal OER catalysts that are highly active and stable at low pH values and high anodic potentials are reviewed to understand their OER mechanisms. Various strategies are proposed for engineering CLs and PTLs to improve the interfacial properties and mass transfers of reactants and products to and from the active sites. Additionally, diagnoses of PTEs is significantly crucial for interpreting electrochemical processes and addressing their current challenges. Therefore, half-cell analyses, including diffusion electrode (DE), floating electrode (FE), and modified rotating disk electrode (MRDE) techniques, are explored, and membrane electrode assembly (MEA)-based analyses, such as the polarization technique, electrochemical impedance spectroscopy, and magnetic field analysis, are established. In conclusion, this study aims to provide an overview of recent technologies used for the engineering and diagnostic tools of PEMWE cells and insights into the advanced components and systems to be developed in this field.

Diagnosis of PEMWE Cells↗

Environmental, Health and Safety Assessment Application of a Heat Integrated, Post-combustion CO2 Capture System Using Monoethanolamine and Hitachi H3-1 Solvent at the E.W. Brown Coal-fired Power Plant

An Environmental Health and Safety (EH&S) Assessment was completed for operation of a pilot scale carbon dioxide (CO2) capture system (CCS) at the Louisville Gas & Electric (LG&E) and Kentucky Utilities (KU) Energy, LLC (LG&E-KU) E. W. Brown Generating Station in Harrodsburg, Mercer County, Kentucky. The pilot system was evaluated using two CO2 capture solvents, monoethanolamine (MEA) and Hitachi’s H3-1 solvent. The purpose of the EH&S Assessment was to determine if there were any unacceptable environmental, health or safety concerns that may prevent operation or environmental permitting of a larger scale pilot scale plant. The assessment included review of process flow diagrams, input and output flow rates for primary materials, literature describing similar processes and chemicals used or created during the process, actual air emission and wastewater test data and air emission calculations. The evaluation included identification of risks related to hazardous chemicals, air emissions, wastewater discharges, solid wastes generated and employee hazards. Most potential EH&S issues that were identified are commonly found and successfully managed at large industrial facilities. No risks were identified that could not be successfully managed or would likely prevent implementation or environmental permitting of the pilot or larger scale plant. Potential exposures and resulting health risks from exposure to low concentrations of nitrosamines generated from degradation of the Hitachi H3-1 and possibly MEA solvents may be a health concern for site workers, but additional investigation is needed to accurately assess this risk. Applying the information gained from operating the pilot plant, performing air emission testing and used solvent testing to a large-scale facility at a commercial coal-fired electric generating plant suggests additional air emission control measures may be necessary to reduce potential site worker health risks and possibly community risks. Depending upon the location and regional air quality, considerable effort may be required to obtain the necessary air permit for construction and operation of a similarly configured large-scale PCCCS facility.

gas separation↗