Search NASA⌕ Search

SEARCH · Search NASA

Results for “MEV”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Diagnostic development and needs for laser driven MeV x-ray radiography

Laser-driven MeV x-ray radiography of dynamic, dense objects demands a small, high flux source of energetic x-rays to generate an image with sufficient quality. Understanding the multi-MeV x-ray spectrum underscores the ability to extrapolate from the current laser sources to new future lasers that might deploy this radiography modality. Here, in this study, we present a small study of the existing x-ray diagnostics and techniques. We also present work from National Ignition Facility-Advanced Radiographic Capability, where we deploy three diagnostics to measure the x-ray spectrum up to 30 MeV. Finally, we also discuss the needs and developments of two new diagnostics: a single crystal scintillator spectrometer and a fast decay activation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MeV x-ray production from a petawatt laser in the regime of a relativistically transparent preplasma, with applications to radiography

Bright sources of mega-electron volt (MeV) x-rays have many unique applications, including nuclear physics, radiation oncology, and imaging high areal density systems. High intensity lasers (>1018 W cm−2) incident on mm-thick metal targets can deliver MeV x-rays via the bremsstrahlung process, providing sources with ultrashort duration (∼ps) and small source size (∼100 μm). Here, we report on a reproducible regime of laser-driven MeV x-ray sources, where the x-ray dose can be further increased by 60% by coating the metal target with micrometers of plastic. High fidelity numerical simulations indicate that the interaction is a result of relativistic transparency in the preplasma. Though relativistic transparency is present in both cases, the greater sound speed and smaller ion inertia of the plastic target allow the laser to more deeply penetrate and couple more efficiently to electrons. Radiography with this system demonstrates a resolving power < 300 μm, important for imaging applications.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Application of machine learning techniques for fast MeV x-ray spectra unfolding from filter stack spectrometer data

Recovery of MeV x-ray spectra from detector signals is difficult because the response matrix inversion is ill-conditioned and current methods are too slow for high-repetition-rate experiments. In this work, we make use of neural networks to unfold MeV x-ray spectra from measurements obtained with a filter stack spectrometer at rates of near 40 Hz. The neural network was trained on synthetic data and tested on both synthetic and experimental data, the latter obtained in two separate experiments performed at the Omega EP laser facility. We show here that this unfolding method has good performance on synthetic data and that it is a promising option for experimental data of up to 40 MeV. The accuracy on experimental data is verified by using a simple forward model to compare against measured values.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Properties of states near 𝐸 𝑥 = 6 MeV in 18 Ne through 17 F +𝑝 scattering

The rate of energy production in the hot-CNO cycle and breakout to the rapid-proton capture process in Type I X-ray bursts is strongly related to the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. The properties of states in 18 Ne near 𝐸 𝑥 = 6.1–6.3 MeV are important for understanding the 14 O⁡(𝛼,𝑝)⁢ 17 F reaction rate. In order to study 18 Ne resonances around this energy region, the RESOLUT radioactive-ion beam facility at Florida State University was used to perform 17 F⁡(𝑝,𝑝)⁢ 17 F elastic scattering on a polypropylene target under inverse kinematics. Scattered protons were detected in a silicon-strip detector array while recoiling 17 F ions were detected in coincidence in a gas ionization detector. An 𝑅-matrix analysis of measured cross sections was conducted along with a reanalysis of data from previous 17 F +𝑝 measurements. All the data analyzed are well described by a consistent set of parameters with a 1 − assignment for a state at 6.14(1) MeV. A second comparable solution is also found with a 3 − assignment for the 6.14(1) MeV state. There is no conclusive evidence supporting one of the two solutions over the other. The rates of the 14 O⁡(𝛼,p)⁢ 17 F reaction that are determined from the two solutions differ by up to an order of magnitude.

6 ≤ A ≤ 19↗

First Event-by-Event Identification of Cherenkov Radiation from Sub-Mev Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon detector by the coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments seven tons (fiducial volume) of liquid argon with 200 eight-inch photomultiplier tubes, 80% of which are coated in a wavelength-shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as - 6 ≤ t < 0 ns relative to the event start time t = 0 , the uncoated photomultiplier tubes are primarily sensitive to visible Cherenkov photons. Using gamma rays from a Na 22 source for production of sub-MeV electrons, we isolated prompt Cherenkov light with > 5 σ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector and represents a milestone in low-energy particle detector development.

Aguilar-Arevalo, A. A. [UNAM, Mexico]↗

Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE

A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Fission product yields from the 238 U ( n,f ) reaction at E n = 4.6 MeV

Here, we present cumulative fission product yields from the 238 U (n, f) reaction at an incident energy of 4.6 MeV for fission products with half-lives from less than one second to several hours. We employed direct γ-ray spectroscopy to measure unseparated fission products with a conventional neutron activation analysis and a cyclic activation technique using the RApid Belt-driven Irradiated Target Transfer System (RABITTS). Yields were determined for 78 isotopes and isomers, covering the mass range 84 ≤ A ≤ 148 and the charge range from 33(As) ≤ Z ≤ 58(Ce). Our experimental cumulative yields are compared to the literature and evaluated data at E n ≈0.5 MeV from ENDF/B-VIII.0 and JEFF-3.3 libraries and with theoretical models using the GEF and FREYA codes at E n =4.6 MeV.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Differential cross sections of the 16 O (𝑛,𝛼) reaction at neutron energies from 3.8 to 15 MeV

The importance of studying the 16 O (𝑛,𝛼) reaction is motivated by multiple nuclear applications which rely on an accurate nuclear reaction data library for oxygen. Discrepancies between past experimental data on the 16 O (𝑛,𝛼) 13 C reaction and its time-reverse 13 C ⁡(𝛼,𝑛) 16 O reaction have led to various different nuclear data evaluations. Here, we have measured 16 O (𝑛,𝛼) reaction cross sections using the LENZ instrument with the unmoderated white neutron source at LANSCE. Results from 2016/2017 data are discussed and used to benchmark the mcnp and geant simulations of the LENZ experimental setup. We report partial differential cross sections of 16 O (𝑛,𝛼 0 ) at 𝐸 𝑛 = 3.8–15 MeV and 16 O ⁡(𝑛,𝛼 1 +𝛼 2 +𝛼 3 ) at 𝐸 𝑛 =9–15 MeV, based on the new measurement in 2021. The resonances that we observed are in good agreement with the levels in 17 O that were previously measured. The LENZ cross sections are in better agreement with the ENDF/B-VIII.0 evaluation than the with reduced cross section found in ENDF/B-VII.1 up to 6 MeV. However, the current results for 16 O ⁡(𝑛,𝛼 0 ) 13 C g.s. appear to be in the best agreement over the entire energy range with that of JENDL/AN-2005 (ENDF/B-VI.0).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for MeV electron recoils from dark matter in EXO-200

We present a search for electron-recoil signatures from the charged-current absorption of fermionic dark matter using the EXO-200 detector. We report an average electron-recoil background rate of 6.8×10 4 ⁢cts ⁢kg −1 yr −1 keV −1 above 4 MeV and find no statistically significant excess over our background projection. Using a total 136 Xe exposure of 234.1 kg yr, we exclude new parameter space for the charged-current absorption cross section for dark matter masses between 𝑚𝜒=2.6–11.6 MeV with a minimum of 6×10 −51 cm 2 at 8.3 MeV at the 90% confidence level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurements of Born cross sections for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV

Using e + e − collision data collected with the BESIII detector operating at the BEPCII collider, the Born cross sections of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . and e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are measured for the first time at center-of-mass energies of s = 4918.0 and 4950.9 MeV. Nonzero cross sections are observed very close to the production threshold. The measured Born cross sections of e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . are about 2–3 times greater than those of e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , providing the similar behavior as semileptonic decays of Λ b 0 , but different behavior from that in the hadronic decays of Λ b 0 . The Born cross sections are 15.6 ± 3.1 ± 0.9 pb and 29.4 ± 3.7 ± 2.7 pb for e + e − → Λ c + Λ ¯ c ( 2595 ) − + c . c . , and are 43.4 ± 4.0 ± 4.1 pb and 76.8 ± 6.5 ± 4.2 pb for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . at s = 4918.0 and 4950.9 MeV, respectively. Based on the polar angle distributions of the Λ ¯ c ( 2625 ) − and Λ c ( 2625 ) + , the form-factor ratios | G E | 2 + 3 | G M | 2 / | G C | are determined for e + e − → Λ c + Λ ¯ c ( 2625 ) − + c . c . for the first time, which are 5.95 ± 4.07 ± 0.15 and 0.94 ± 0.32 ± 0.02 at s = 4918.0 and 4950.9 MeV, respectively. All of these first uncertainties are statistical and second systematic. Published by the American Physical Society 2024

Astronomy & Astrophysics↗

Reviving MeV-GeV indirect detection with inelastic dark matter

Thermal relic dark matter below ∼ 10 GeV is excluded by cosmic microwave background data if its annihilation to visible particles is unsuppressed near the epoch of recombination. Usual model-building measures to avoid this bound involve kinematically suppressing the annihilation rate in the low-velocity limit, thereby yielding dim prospects for indirect detection signatures at late times. In this work, we investigate a class of cosmologically viable sub-GeV thermal relics with late-time annihilation rates that are detectable with existing and proposed telescopes across a wide range of parameter space. We study a representative model of inelastic dark matter featuring a stable state χ 1 and a slightly heavier excited state χ 2 whose abundance is thermally depleted before recombination. Since the kinetic energy of dark matter in the Milky Way is much larger than it is during recombination, χ 1 χ 1 → χ 2 χ 2 upscattering can efficiently regenerate a cosmologically long-lived Galactic population of χ 2 , whose subsequent coannihilations with χ 1 give rise to observable gamma-rays in the ∼ 1 MeV − 100 MeV energy range. We find that proposed MeV gamma-ray telescopes, such as e-ASTROGAM, AMEGO, and MAST, would be sensitive to much of the thermal relic parameter space in this class of models and thereby enable both discovery and model discrimination in the event of a signal at accelerator or direct detection experiments. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Dirac spectral density in N f = 2 + 1 QCD at T = 230 MeV

We compute the renormalized Dirac spectral density in N f = 2 + 1 QCD at physical quark masses, temperature T = 230 MeV , and system size L s = 3.4 fm . To that end, we perform a pointwise continuum limit of the staggered density in lattice QCD with staggered quarks. We find, for the first time, that a clear infrared structure (IR peak) emerges in the density of the Dirac operator describing dynamical quarks. We also provide numerical evidence that a component of this peak, which becomes dominant in the thermodynamic limit, is due to a nontrivial accumulation of near-zero modes. Features of this structure are consistent with those previously attributed to the recently proposed IR phase of thermal QCD. Our results (i) provide the only complete first-principles evidence that these IR features exist and are physical, (ii) improve the upper bound for IR phase transition temperature T IR so that the new window is 200 < T IR < 230 MeV , and (iii) are consistent with the nonrestoration of anomalous U A ( 1 ) symmetry (chiral limit) below T = 230 MeV . Published by the American Physical Society 2024

Alexandru, Andrei (ORCID:0000000345471554)↗

Sub-MeV dark sink dark matter

A dark sink uses dark-sector interactions to siphon energy from dark matter to lighter dark degrees of freedom, i.e., dark radiation. Here, we extend dark matter models containing a dark sink to sub-MeV masses. We consider a dark sink model where the dark matter is charged under a light dark photon that has kinetic mixing with the Standard Model. For sub-MeV dark matter masses, plasmon decays are the dominant mechanism for transferring energy to the dark sector. Relative to a standard freeze-in cosmology, reproducing the observed dark matter density in a dark sink structure requires an increase in the dark matter couplings to the Standard Model, and hence increased direct detection cross sections. These models provide benchmarks for current and upcoming direct detection experiments. Accounting for plasmon effects, we derive the range of possible dark matter masses and cross sections for dark sink models in the sub-MeV regime. We make the freezein code available to reproduce our benchmarks; it may be of use for other freeze-in scenarios, including those where plasmon decays to the dark matter are important.

Dark matter detectors↗

Searching for MeV-mass neutrinophilic dark matter with large scale dark matter detectors

The indirect detection of dark matter (DM) through its annihilation products is one of the primary strategies for DM detection. One of the least constrained classes of models is neutrinophilic DM, because the annihilation products, weakly interacting neutrinos, are challenging to observe. Here, we consider a scenario where MeV-mass DM exclusively annihilates to the third neutrino mass eigenstate, which is predominantly of tau and muon flavor. In such a scenario, the potential detection rate of the neutrinos originating from the DM annihilation in our Galaxy in the conventional detectors would be suppressed by up to approximately two orders of magnitude. This is because the best sensitivity of such detectors for neutrinos with energies below approximately 100 MeV is for electron neutrino flavor. In this work, we highlight the potential of large-scale DM detectors in uncovering such signals in the tens of MeV range of DM masses. In addition, we discuss how coincident signals in direct detection DM experiments and upcoming neutrino detectors such as DUNE, Hyper-Kamiokande, and JUNO could provide new perspectives on the DM problem. Published by the American Physical Society 2025

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Heavy Quark Diffusion from 2+1 Flavor Lattice QCD with 320 MeV Pion Mass

We present the first calculations of the heavy flavor diffusion coefficient using lattice QCD with light dynamical quarks corresponding to a pion mass of around 320 MeV. For temperatures 195 MeV< 𝑇 <352 MeV, the heavy quark spatial diffusion coefficient is found to be significantly smaller than previous quenched lattice QCD and recent phenomenological estimates. The result implies very fast hydrodynamization of heavy quarks in the quark-gluon plasma created during ultrarelativistic heavy-ion collision experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Search for Daily Modulation of MeV Dark Matter Signals with DAMIC-M

Dark matter (DM) particles with sufficiently large cross sections may scatter as they travel through Earth’s bulk. The corresponding changes in the DM flux give rise to a characteristic daily modulation signal in detectors sensitive to DM-electron interactions. Here, we report results obtained from the first underground operation of the DAMIC-M prototype detector searching for such a signal from DM with MeV-scale mass. A model-independent analysis finds no modulation in the rate of 1 e − events with sidereal period, where a DM signal would appear. We then use these data to place exclusion limits on DM in the mass range [ 0.53 , 2.7 ] MeV / c 2 interacting with electrons via a dark photon mediator. Taking advantage of the time-dependent signal we improve by ∼ 2 orders of magnitude on our previous limit obtained from the total rate of 1 e − events, using the same dataset. This daily modulation search represents the current strongest limit on DM-electron scattering via ultralight mediators for DM masses around 1 MeV / c 2 . Published by the American Physical Society 2024

Arnquist, I. (ORCID:0000000256438330)↗

Optimizing MeV photon dose generation in laser-solid interactions via stable beam propagation

Bremsstrahlung MeV x rays with high doses are essential for radiography of dense objects. Intense, short-pulse laser-driven MeV x-ray sources offer a promising solution, but understanding how the dose scales with laser intensity is crucial for their development. While theory predicts a square root scaling with laser intensity, experimental verification has been hindered by significant shot-to-shot variations, often exacerbated by long preplasma scale lengths from low laser contrast. Here, we demonstrate low shot-to-shot dose variation and confirm the theoretical scaling using high-contrast OMEGA EP laser interactions with millimeter-thick tantalum foils, achieving MeV x-ray doses up to 5.4 rad at 1 m for E photon > 500 keV. Simulations reveal that the unique focal spot of the OMEGA EP laser enables efficient x-ray generation and reduced variability by facilitating deeper laser penetration into dense plasma, even with shorter preplasma scale lengths. Published by the American Physical Society 2025

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a 10 MeV beamline at the Upgraded Injector Test Facility for e-beam irradiation

Electron beam irradiation near 10 MeV is suitable for wastewater treatment. The Upgraded Injector Test Facility (UITF) at Jefferson Lab is a CW superconducting linear accelerator capable of providing an electron beam of energy up to 10 MeV and up to 100 µA current. This contribution presents the beam transport simulations for a beamline to be used for the irradiation of wastewater samples at the UITF. The simulations were done using the code General Particle Tracer with the goal of obtaining an 8 MeV electron beam of radius (3-σ) of ~2.4 cm. The achieved energy spread is ~74.5 keV. The space charge effects were investigated when the bunch charge is varied to be up to 1000 times and the results showed that they do not affect the beam quality significantly.

Li, X.↗