Search NASA⌕ Search

SEARCH · Search NASA

Results for “ML requirements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Space Launch System Mobile Launcher Modal Pretest Analysis

NASA is developing an expendable heavy lift launch vehicle capability, the Space Launch System, to support lunar and deep space exploration. To support this capability, an updated ground infrastructure is required including modifying an existing Mobile Launcher system. The Mobile Launcher is a very large heavy beam/truss steel structure designed to support the Space Launch System during its buildup and integration in the Vehicle Assembly Building, transportation from the Vehicle Assembly Building out to the launch pad, and provides the launch platform at the launch pad. The previous Saturn/Apollo and Space Shuttle programs had integrated vehicle ground vibration tests of their integrated launch vehicles performed with simulated free-free boundary conditions to experimentally anchor and validate structural and flight controls analysis models. For the Space Launch System program, the Mobile Launcher will be used as the modal test fixture for the ground vibration test of the first Space Launch System flight vehicle, Exploration Mission ? 1( now referred to as Artemis 1), programmatically referred to as the Integrated vehicle modal test. The Integrated vehicle modal test of the Exploration Mission - 1 integrated launch vehicle will have its core and second stages unfueled while mounted to the ML while inside the Vehicle Assembly Building, which is currently scheduled for the late spring or early summer of 2020. The Space Launch System program has implemented a building block approach for dynamic model validation. The modal test of the Mobile Launcher is an important part of this building block approach in supporting the integrated vehicle modal test since the Mobile Launcher will serve as a structurally dynamic test fixture whose modes will couple with the modes of the Exploration Mission ? 1 test vehicle. The Mobile Launcher modal test will further support understanding the structural dynamics of the Mobile Launcher and SLS during rollout to the launch pad, which will play a key role in better understanding and prediction of the rollout forces acting on the launch vehicle. The Mobile Launcher modal test is currently scheduled for the summer of 2019. Due to a very tight modal testing schedule, this Mobile Launcher modal pretest analysis has been performed to ensure there is a high likelihood of being able to successfully complete the modal test (i.e. identify the primary target modes) using the planned instrumentation, shakers, and excitation types. This paper will discuss this Mobile Launcher modal pretest analysis and the unique challenges faced due to the Mobile Launcher's size and weight, which are typically not faced when modal testing aerospace structures.

Akers, James C.↗

Three-Dimensional, Transgenic Cell Models to Quantify Space Genotoxic Effects

The space environment contains radiation and chemical agents known to be mutagenic and carcinogenic to humans. Additionally, microgravity is a complicating factor that may modify or synergize induced genotoxic effects. Most in vitro models fail to use human cells (making risk extrapolation to humans more difficult), overlook the dynamic effect of tissue intercellular interactions on genotoxic damage, and lack the sensitivity required to measure low-dose effects. Currently a need exists for a model test system that simulates cellular interactions present in tissue, and can be used to quantify genotoxic damage induced by low levels of radiation and chemicals, and extrapolate assessed risk to humans. A state-of-the-art, three-dimensional, multicellular tissue equivalent cell culture model will be presented. It consists of mammalian cells genetically engineered to contain multiple copies of defined target genes for genotoxic assessment,. NASA-designed bioreactors were used to coculture mammalian cells into spheroids, The cells used were human mammary epithelial cells (H184135) and Stratagene's (Austin, Texas) Big Blue(TM) Rat 2 lambda fibroblasts. The fibroblasts were genetically engineered to contain -a high-density target gene for mutagenesis (60 copies of lacl/LacZ per cell). Tissue equivalent spheroids were routinely produced by inoculation of 2 to 7 X 10(exp 5) fibroblasts with Cytodex 3 beads (150 micrometers in diameter). at a 20:1 cell:bead ratio, into 50-ml HARV bioreactors (Synthecon, Inc.). Fibroblasts were cultured for 5 days, an equivalent number of epithelial cells added, and the fibroblast/epithelial cell coculture continued for 21 days. Three-dimensional spheroids with diameters ranging from 400 to 600 micrometers were obtained. Histological and immunohistochemical Characterization revealed i) both cell types present in the spheroids, with fibroblasts located primarily in the center, surrounded by epithelial cells; ii) synthesis of extracellular matrix; and iii,, mitotic cells located throughout the spheroids. Spheroidal integrity and cell viability were retained for the 30-day test period after removal of spheroids from the bioreactor. Potential utility of this three-dimensional, transgenic model for genotoxicity was initially assessed by exposure of spheroids to 0-2 Gy neon at dose rates of 0.3 to 1.5 Gy/min (National Institute of Radiological Sciences, Chiba, Japan). Quantification of mutation at the lacl gene revealed a linear dose response for mutation induction. Limited sequencing analysis of mutant clones revealed higher frequencies of deletions and multiple base sequence changes with increasing dose. These results suggest that our three-dimensional, transgenic model is applicable to a wide variety of studies involving the quantification, identification, and characterization of genotoxicity incurred in space and on Earth. This model uniquely allows investigation of the interaction of relevant factors, namely cell-to-cell interactions and the mechanistic interaction of microgravity with radiation insults and DNA repair. Using this three-dimensional model will allow us to obtain dual genotoxic information (i.e., mutation rate plus chromosome aberration data) from the same system so that one endpoint can be used to reference the other, thereby increasing the fidelity of the data set. Moreover, the tissue-equivalent nature of the three-dimensional model provides high confidence for relevance of risk assessment, i.e., the establishment of quality factors directly applicable to the microgravity environment.

Gonda, S. R.↗

Prognostics for Systems Health Management - Model and Hybrid Based Approaches. Where are We Heading?

To facilitate and solve the prediction problem, awareness of the current state and health of the system is key, since it is necessary to perform condition-based system health predictions. To accurately predict the future state of any system, it is required to possess knowledge of its current health state and future operational conditional. In case of next generation electric aircrafts, computing remaining flying time is safety-critical, since an aircraft that runs out of power (battery charge) while in the air will eventually lose control leading to catastrophe. In order to tackle and solve the prediction problem, it is essential to have awareness of the current health state of the system, especially since it is necessary to perform condition-based predictions. To be able to predict the future state of the system, it is also required to possess knowledge of the current and future operational conditions and flight profiles for accurate estimation of end-of-discharge (EOD) for the batteries. Similar framework can be implemented to other complex systems and subsystems. Our research approach is to develop a system level health monitoring safety indicator which runs estimation and prediction algorithms to estimate remaining useful life predictions at system, subsystem swell as component levels. Given models of the current and future system behavior, a general approach of model-based prognostics is discussed as a solution to the prediction problem and further for decision making. Data driven prognostics approaches have been equally used with good results in the past, where respective approaches have their own challenges to tackle. This limits their applicability to complex real-world domains: (a) high complexity or incompleteness of physics-based models and (b) limited representativeness of the training dataset for data-driven models. With the advent of internet of things for data collection and increased use of ML algorithms, hybrid approaches are the next avenue to reduce the challenges and achieve better results. An hybrid framework for fusing information from physics-based performance models along with deep learning algorithms for prognostics of complex safety critical systems is presented. In this framework, we use physics-based performance models to infer unobservable model parameters related to the system's components health solving a calibration problem.

Prognostics↗

Automated Desalting Apparatus

Because salt and metals can mask the signature of a variety of organic molecules (like amino acids) in any given sample, an automated system to purify complex field samples has been created for the analytical techniques of electrospray ionization/ mass spectroscopy (ESI/MS), capillary electrophoresis (CE), and biological assays where unique identification requires at least some processing of complex samples. This development allows for automated sample preparation in the laboratory and analysis of complex samples in the field with multiple types of analytical instruments. Rather than using tedious, exacting protocols for desalting samples by hand, this innovation, called the Automated Sample Processing System (ASPS), takes analytes that have been extracted through high-temperature solvent extraction and introduces them into the desalting column. After 20 minutes, the eluent is produced. This clear liquid can then be directly analyzed by the techniques listed above. The current apparatus including the computer and power supplies is sturdy, has an approximate mass of 10 kg, and a volume of about 20 20 20 cm, and is undergoing further miniaturization. This system currently targets amino acids. For these molecules, a slurry of 1 g cation exchange resin in deionized water is packed into a column of the apparatus. Initial generation of the resin is done by flowing sequentially 2.3 bed volumes of 2N NaOH and 2N HCl (1 mL each) to rinse the resin, followed by .5 mL of deionized water. This makes the pH of the resin near neutral, and eliminates cross sample contamination. Afterward, 2.3 mL of extracted sample is then loaded into the column onto the top of the resin bed. Because the column is packed tightly, the sample can be applied without disturbing the resin bed. This is a vital step needed to ensure that the analytes adhere to the resin. After the sample is drained, oxalic acid (1 mL, pH 1.6-1.8, adjusted with NH4OH) is pumped into the column. Oxalic acid works as a chelating reagent to bring out metal ions, such as calcium and iron, which would otherwise interfere with amino acid analysis. After oxalic acid, 1 mL 0.01 N HCl and 1 mL deionized water is used to sequentially rinse the resin. Finally, the amino acids attached to the resin, and the analytes are eluted using 2.5 M NH4OH (1 mL), and the NH4OH eluent is collected in a vial for analysis.

Spencer, Maegan K.↗

Real-time three-dimensional echocardiographic study of left ventricular function after infarct exclusion surgery for ischemic cardiomyopathy

BACKGROUND: Infarct exclusion (IE) surgery, a technique of left ventricular (LV) reconstruction for dyskinetic or akinetic LV segments in patients with ischemic cardiomyopathy, requires accurate volume quantification to determine the impact of surgery due to complicated geometric changes. METHODS AND RESULTS: Thirty patients who underwent IE (mean age 61+/-8 years, 73% men) had epicardial real-time 3-dimensional echocardiographic (RT3DE) studies performed before and after IE. RT3DE follow-up was performed transthoracically 42+/-67 days after surgery in 22 patients. Repeated measures ANOVA was used to compare the values before and after IE surgery and at follow-up. Significant decreases in LV end-diastolic (EDVI) and end-systolic (ESVI) volume indices were apparent immediately after IE and in follow-up (EDVI 99+/-40, 67+/-26, and 71+/-31 mL/m(2), respectively; ESVI 72+/-37, 40+/-21, and 42+/-22 mL/m(2), respectively; P:<0.05). LV ejection fraction increased significantly and remained higher (0.29+/-0.11, 0.43+/-0.13, and 0.42+/-0.09, respectively, P:<0.05). Forward stroke volume in 16 patients with preoperative mitral regurgitation significantly improved after IE and in follow-up (22+/-12, 53+/-24, and 58+/-21 mL, respectively, P:<0.005). New York Heart Association functional class at an average 285+/-144 days of clinical follow-up significantly improved from 3.0+/-0.8 to 1.8+/-0.8 (P:<0.0001). Smaller end-diastolic and end-systolic volumes measured with RT3DE immediately after IE were closely related to improvement in New York Heart Association functional class at clinical follow-up (Spearman's rho=0.58 and 0.60, respectively). CONCLUSIONS: RT3DE can be used to quantitatively assess changes in LV volume and function after complicated LV reconstruction. Decreased LV volume and increased ejection fraction imply a reduction in LV wall stress after IE surgery and are predictive of symptomatic improvement.

Non-NASA Center↗

Estimation of Optimum Stimulus Amplitude for Balance Training using Electrical Stimulation of the Vestibular System

Sensorimotor changes such as posture and gait instabilities can affect the functional performance of astronauts after gravitational transitions. Sensorimotor Adaptability (SA) training can help alleviate decrements on exposure to novel sensorimotor environments based on the concept of 'learning to learn' by exposure to varying sensory challenges during posture and locomotion tasks (Bloomberg 2015). Supra-threshold Stochastic Vestibular Stimulation (SVS) can be used to provide one of many challenges by disrupting vestibular inputs. In this scenario, the central nervous system can be trained to utilize veridical information from other sensory inputs, such as vision and somatosensory inputs, for posture and locomotion control. The minimum amplitude of SVS to simulate the effect of deterioration in vestibular inputs for preflight training or for evaluating vestibular contribution in functional tests in general, however, has not yet been identified. Few studies (MacDougall 2006; Dilda 2014) have used arbitrary but fixed maximum current amplitudes from 3 to 5 mA in the medio-lateral (ML) direction to disrupt balance function in healthy adults. Giving this high level of current amplitude to all the individuals has a risk of invoking side effects such as nausea and discomfort. The goal of this study was to determine the minimum SVS level that yields an equivalently degraded balance performance. Thirteen subjects stood on a compliant foam surface with their eyes closed and were instructed to maintain a stable upright stance. Measures of stability of the head, trunk, and whole body were quantified in the ML direction. Duration of time they could stand on the foam surface was also measured. The minimum SVS dosage was defined to be that level which significantly degraded balance performance such that any further increase in stimulation level did not lead to further balance degradation. The minimum SVS level was determined by performing linear fits on the performance variable at different stimulation levels. Results from the balance task suggest that there are inter-individual differences and the minimum SVS amplitude was found to be in the range of 1 mA to 2.5 mA across subjects. SVS resulted in an average decrement of balance task performance in the range of 62%-73% across different measured variables at the minimum SVS amplitude in comparison to the control trial (no stimulus). Training using supra-threshold SVS stimulation is one of the sensory challenges used for preflight SA training designed to improve adaptability to novel gravitational environments. Inter-individual differences in response to SVS can help customize the SA training paradigms using minimal dosage required. Another application of using SVS is to simulate acute deterioration of vestibular sensory inputs in the evaluation of tests for assessing vestibular function.

Goel, R.↗

Digital Lunar Exploration Sites (DLES) Terrain Crafting

Humans will soon be returning to the surface of the Moon with NASA’s Artemis program. The Artemis program is an international collaboration that will consist of a complex series of space systems and missions to explore the lunar surface and pave the way for the future exploration of Mars. NASA and its partners rely heavily on simulation for lighting and navigation studies as well as training astronauts, flight controllers, and mission support staff. The NASA Exploration Systems Simulations (NExSyS) team in the Simulation and Graphics Branch (ER7) in the Engineering Directorate at NASA’s Johnson Space Center has built up many simulation products to support this effort, one of which is the Digital Lunar Exploration Sites (DLES). DLES is a collection of products used to simulate and render the lunar surface in a digital environment. We discussed and presented an overview of the DLES products at the 2022 IEEE Aerospace Conference in Big Sky, MT with a paper titled "Digital Lunar Exploration Sites". This “DLES Terrain Crafting” paper will expand on the information previously provided in “DLES” paper and dive deeper into the details of the terrain crafting process and the toolsets used to support this task. The best digital data currently available of the lunar surface is provided by the Lunar Reconnaissance Orbiter (LRO). Its Lunar Orbiter Laser Altimeter (LOLA) achieves an impressive resolution of 5m per pixel at the Lunar South Pole (LSP) and can generate datasets covering a large continuous region near the LSP. There are a few additional methods, such as Shape from Shading which can infer higher resolution data (up to 1m per pixel) from the LRO Narrow Angle Camera (NAC) images. However, surface-based simulations require higher-resolution data, and this paper will discuss the process of enhancing the terrain to meet that need. The process begins with capturing statistical data of craters in the regions of interest using images provided by the LRO NAC. This data is then used to scatter artificial features which are not captured in the truth data, resulting in an enhanced DEM with a much higher resolution of 20cm per pixel. Many tools were built up to assist in the creation of these artificial Digital Elevation Models (DEM), which this paper will discuss in detail. DEMs themselves are a very powerful representation of a planetary surface, and many operations and tools can utilize the data they contain. This paper includes a description of the rendering of the lunar surface in a graphics engine, generation of contact patches to simulate tire to ground interaction, and ray tracing utilities to model Line of Sight (LOS) interactions with the terrain. This paper will also explore some new tool sets currently under development which aim to utilize Machine Learning (ML) to assist in the identification of craters from LRO NAC imagery. While this is not a novel idea, the NExSyS team is developing a unique approach which may result in more robust identification of crater characteristics.

Artemis↗

Tissue Engineered Skeletal Myofibers can Directly "Sense" Gravitational Force Changes

Long-term manned space flight requires a better understanding of skeletal muscle atrophy resulting from microgravity. Atrophy most likely results from changes at both the systemic level (e.g. decreased circulating growth hormone, increased circulating glucocorticoids) and locally (e.g. decreased myofiber resting tension). Differentiated skeletal myofibers in tissue culture have provided a model system over the last decade for gaining a better understanding of the interactions of exogenous growth factors, endogenous growth factors, and muscle fiber tension in regulating protein turnover rates and muscle cell growth. Tissue engineering these cells into three dimensional bioartificial muscle (BAM) constructs has allowed us to extend their use to Space flight studies for the potential future development of countermeasures. Embryonic avian muscle cells were isolated and BAMs tissue engineered as described previously. The myoblasts proliferate and fuse into aligned postmitotic myofibers after ten to fourteen days in vitro. A cylindrical muscle-like structure containing several thousand myofibers is formed which is approximately 30 mm in length, 2-3 mm in diameter, and attached at each end. For the Space Shuttle experiments, the BAMs were transferred to 55 mL bioreactor cartridges (6 BAMs/cartridge). At Kennedy Space Center, the cartridges were mounted in two Space Tissue Loss (STL) Modules (three to four cartridges per Module) and either maintained as ground controls or loaded in a Mid-Deck locker of the Space Shuttle. The BAM cartridges were continuously perfused during the experiment at 1.5 mL/ min with tissue culture medium. Eighteen BAMs were flown for nine days on Mission STS66 while eighteen BAMs served as ground controls. The complete experiment was repeated on Mission STS77 with twenty four BAMs in each group. BAMs could be maintained in a healthy state for at least 30 days in the perfusion bioreactor cartridges. The BAM muscle fibers directly detected both the loss of gravity and the reloading effects of 1 x g. While total cellular metabolism and total protein degradation rates were not altered during 9 to 10 days in Space, protein synthesis rates were significantly reduced and resulted in significant myofiber atrophy compared to ground controls. One g reloading of the flight muscle cells post-flight significantly increased protein synthesis rates and the synthesis rates of myosin heavy chain, fibronectin, and collagen. Tissue cultured muscle cells can directly "sense" changes in gravity and provide a valid model to begin the study of countermeasures. Based on our ground based experiments, and the experiments of others, growth hormone and/or insulin-like growth factors are attractive protein therapeutics which may assisting attenuating skeletal muscle wasting in space. Our laboratory is developing a new cell-based delivery system for this and other potential therapeutic factors for attenuating muscle and bone wasting.

Vandenburgh, Herman H.↗

Qualitative Headspace GCMS Analysis of Lunar Regolith and Volatile Simulant Mixtures

Introduction: Future Artemis missions aim to return the volatile-bearing samples collected near lunar polar craters. We, as advanced curation scientists, are responsible for developing techniques and methodologies for preserving the integrity of returned samples and the science value those samples contain. The extent to which that preservation is possible, and the trade-offs preservation requires (e.g. monetary costs, sample volume limitations) all must be considered. Even less-than pristine volatile-bearing samples will be of tremendous value to the scientific community seeking to unravel the history of lunar surface volatiles and, more broadly, volatiles in the solar system. A sample collected on the lunar surface will experience at least five distinctive periods during which any changes here referred to as “alteration” will certainly occur at some scale: collection on the lunar surface; transportation back to Earth; long-term storage; curatorial processing; and allocation/distribution. The Planetary Exploration and Astromaterials Research Lab (PEARL) seeks to understand temperature and pressure effects on returned volatile samples by working with high-fidelity volatile-containing regolith simulants, setting the foundation for the future of cold curation. This abstract is focused on gas-surface interactions between LCROSS volatiles and readily available lunar regolith simulants. Experiments involved analyzing differences in headspace gas composition for various combinations of volatile and regolith simulants using gas chromatography/mass spectrometry (GC/MS). Experimental Procedure: The volatile simulants were chosen based on the molecules detected during the LCROSS mission.1 Stock solutions of condensed lunar volatile analytes were: methanol, 7 N ammonia in methanol, and 0.4% hydrogen sulfide in water. The regolith simulants used were primarily JSC-1A and NU-LHT-4M. Additional regolith simulant control studies were conducted with <150 μm sieved sand and KBr. A nested vial sample preparation approach separated the liquid stock solutions from the regolith, eliminating potential matrix effects between liquid and solid phases. Fifteen microliter aliquots of liquid volatile simulants were added to a 2 mL liquid GC vial and capped in atmosphere. An 18G needle punctured the 2 mL GC vial immediately before being transferred and sealed in a 20 mL GC vial containing 0-0.3 g of regolith simulant, see Figure 1. Separating the analytes ensures any changes observed in the total headspace gases is a result of gas-surface and/or gas-gas interactions. Equipment and Method: Initial GC/MS method development for the separation and identification of relevant headspace gases can be found in Amick, et al. 2023.2 The only hardware change is a different column: a TG-1701MS 30 m × 0.25 mm × 1.00 μm column. The vials were sampled at 10°C, room temperature (~25°C) and 50°C. Low temperature samples were kept in a chilled autosampler stage for at least 1 hour prior to sampling. High temperature samples were agitated at 50°C for 5 minutes immediately prior to injection onto the column. Headspace chromatograms were collected for each combination of temperature, regolith, and volatile simulant, including controls without one or both types of analytes, in triplicate. The chromatogram elution window for each analyte or significant atmospheric gas was identified using the peak mass spectrum cross-referenced with Figure 1.Picture of the nested vial set-up. a NIST MS library search. Each analyte peak was integrated after filtering the mass spectrum trace for the parent or most unique mass-to-charge ratio. For example, the mass-to-charge ratio used to identify, filter for, and integrate the carbon dioxide peak was centered around 44 m/z. Results: Figure 2 shows the integrated peak area for hydrogen sulfide in all combinations of regolith simulants, temperatures, and the addition of ammonia in methanol solution. Multiple repeat experiments with H2S and regolith simulants have confirmed hydrogen sulfide is removed from the headspace within 1 hour when exposed to JSC-1A, NU-LHT-4M and sand (not pictured). The consumption of H2S by lunar regolith simulants at different temperatures indicates surface chemistry will be an integral component in sample integrity and preservation. It is important to note that while the effect of surface chemistry on gaseous hydrogen sulfide is intriguing, further investigation into more chemically accurate regolith simulants is necessary and ongoing. The sulfur in hydrogen sulfide is in its most reduced state while off-the-shelf, terrestrially sourced JSC-1A and NU-LHT-4M are more oxidized than most lunar materials,3which likely leads to different oxidation-reduction reactions than would be expected in lunar regolith. Figure 3 shows the integrated peak area of carbon dioxide for each sample combination that contained ammonia in methanol solution. The addition of ammonia to the GC vials results in a consistent and reproducible decrease in carbon dioxide gas, even at 50°C. The effect became more pronounced when JSC-1A or NU-LHT-4M were present. This set of experiments demonstrated that the sample composition will affect the chemical and physical state of each component present. Future spectroscopic and microscopy experiments will be geared towards identifying the cause for the CO2(g) concentration decrease and the consumption of hydrogen sulfide. As cold and volatile curation scientists, this information provides necessary insight on how to appropriately handle and analyze volatile bearing returned samples, as well as predict the effect chemical composition has on the various sample phases we will analyze upon return to Earth. Unlike traditional curation of geologic materials, the molecules in a sample cannot be identified or processed using the naked eye or even an optical microscope. Volatile curation will require a combination of analytical techniques, including but not limited to highly sensitive gas and solid/condensed phase spectroscopy. This set of experiments has demonstrated the need for more detailed studies of volatile mixtures with mineralogically and geochemically analogous lunar regolith simulants to prepare for the curation of volatile-rich lunar samples from the south polar region of the Moon. References: [1] Colaprete, A., et al. (2010) Science, 330, (463-468). [2] Amick, C. L., et al.(2023) Houston, Texas, [3] Heiken, G. H., et al.(1991) (778-778)

Cecilia L Amick↗

Blocking Losses With a Photon Counter

It was not known how to assess accurately losses in a communications link due to photodetector blocking, a phenomenon wherein a detector is rendered inactive for a short time after the detection of a photon. When used to detect a communications signal, blocking leads to losses relative to an ideal detector, which may be measured as a reduction in the communications rate for a given received signal power, or an increase in the signal power required to support the same communications rate. This work involved characterizing blocking losses for single detectors and arrays of detectors. Blocking may be mitigated by spreading the signal intensity over an array of detectors, reducing the count rate on any one detector. A simple approximation was made to the blocking loss as a function of the probability that a detector is unblocked at a given time, essentially treating the blocking probability as a scaling of the detection efficiency. An exact statistical characterization was derived for a single detector, and an approximation for multiple detectors. This allowed derivation of several accurate approximations to the loss. Methods were also derived to account for a rise time in recovery, and non-uniform illumination due to diffraction and atmospheric distortion of the phase front. It was assumed that the communications signal is intensity modulated and received by an array of photon-counting photodetectors. For the purpose of this analysis, it was assumed that the detectors are ideal, in that they produce a signal that allows one to reproduce the arrival times of electrons, produced either as photoelectrons or from dark noise, exactly. For single detectors, the performance of the maximum-likelihood (ML) receiver in blocking is illustrated, as well as a maximum-count (MC) receiver, that, when receiving a pulse-position-modulated (PPM) signal, selects the symbol corresponding to the slot with the largest electron count. Whereas the MC receiver saturates at high count rates, the ML receiver may not. The loss in capacity, symbol-error-rate (SER), and count-rate were numerically computed. It was shown that the capacity and symbol-error-rate losses track, whereas the count-rate loss does not generally reflect the SER or capacity loss, as the slot-statistics at the detector output are no longer Poisson. It is also shown that the MC receiver loss may be accurately predicted for dead times on the order of a slot.

Moision, Burce E.↗

Comparison of V-4 and V-5 Exercise/Oxygen Prebreathe Protocols to Support Extravehicular Activity in Microgravity

The Prebreathe Reduction Program (PRP) used exercise during oxygen prebreathe to reduce necessary prebreathe time prior to depressurizing to work in a 4.3 psi suit during extravehicular activity (EVA). Initial testing produced a two-hour protocol incorporating ergometry exercise and a 30 min cycle of depress/repress to 10.2 psi where subjects breathed 26.5% oxygen/balance nitrogen (Phase II - 10 min at 75% peak oxygen consumption [VO2 peak] followed by 40 min intermittent light exercise [ILE] [approx. 5.8 mL-per kilogram- per minute], then 50 min of rest). The Phase II protocol (0/45 DCS) was approved for operations and has been used on 40 EVAs, providing significant time savings compared to the standard 4 h resting oxygen prebreathe. The Phase V effort focused on performing all light in-suit exercise. Two oxygen prebreathe protocols were tested sequentially: V-4) 160 min prebreathe with 150 min of continuous ILE. The entire protocol was completed at 14.7 psi. All exercise involved upper body effort. Exercise continued until decompression. V-5) 160 min prebreathe with 140 min of ILE - first 40 min at 14.7 psi, then 30 min at 10.2 psi (breathing 26.5% oxygen) after a 20 min depress, simulating a suit donning period. Subjects were then repressed to 14.7 psi and performed another 50 min of lower body ILE, followed by 50 min rest before decompression. The V-4 protocol was rejected with 3 DCS/6 person-exposures. Initial V-5 testing has produced 0 DCS/11 person-exposures (ongoing trials). The difference in DCS rate was significant (Fisher Exact p=0.029). The observations of DCS were significantly lower in early V-5 trials than in V-4 trials. Additional studies are required to evaluate the relative contribution of the variables in exercise distribution, the 10.2 psi depress/repress component, pre-decompression rest, or possible variation in total oxygen consumption.

Pollock, N. W.↗

Removal of Burkholderia cepacia biofilms with oxidants

Iodine is used to disinfect the water system aboard US space shuttles and is the anticipated biocide for the international space station. Water quality on spacecraft must be maintained at the highest possible levels for the safety of the crew. Furthermore, the treatment process used to maintain the quality of water on research must be robust and operate for long periods with minimal crew intervention. Biofilms are recalcitrant and pose a major threat with regard to chronic contamination of spacecraft water systems. We measured the effectiveness of oxidizing biocides on the removal and regrowth of Burkholderia (Pseudomonas) cepacia biofilms. B. cepacia, isolated from the water distribution system of the space shuttle Discovery, was grown in continuous culture to produce a bacterial contamination source for biofilm formation and removal studies. A 10(7) CFU ml-1 B. cepacia suspension, in distilled water, was used to form biofilms on 3000 micrometers2 glass surfaces. Rates of attachment were measured directly with image analysis and were found to be 7.8, 15.2, and 22.8 attachment events h-1 for flow rates of 20.7, 15.2, and 9.8 ml min-1, respectively. After 18 h of formation, the B. cepacia biofilms were challenged with oxidants (ozone, chlorine, and iodine) and the rates of biofilm removal determined by image analysis. Fifty percent of the biofilm material was removed in the first hour of continous treatment with 24 mg l-1 chlorine or 2 mg l-1 ozone. Iodine (48 mg l-1) did not remove any measurable cellular material after 6 h continuous contact. After this first removal of biofilms by the oxidants, the surface was allowed to refoul and was again treated with the biocide. Iodine was the only compound that was unable to remove cellular debris from either primary or secondary biofilms. Moreover, treating primary biofilms with iodine increased the rate of formation of secondary biofilms, from 4.4 to 5.8 attachment events h-1. All the oxidants tested inactivated the B. cepacia associated with both primary and secondary biofilms. The amount of biocide needed to inactivate 50% of planktonic B. cepacia in 10 min at 25 degrees C was 8.4, 0.5, and 0.2 mg l-1 for iodine, chlorine, and ozone, respectively. The data suggest that iodine maynot be the best chemical for treating of biofilms when removal of cellular material is required.

NASA Discipline Environmental Health↗

Modelflow Estimates of Stroke Volume Do Not Correlate With Doppler Ultrasound Estimates During Upright Posture

Orthostatic intolerance affects 60‐80% of astronauts returning from long‐duration missions, representing a significant risk to completing mission‐critical tasks. While likely multifactorial, a reduction in stroke volume (SV) represents one factor contributing to orthostatic intolerance during stand and head up tilt (HUT) tests. Current measures of SV during stand or HUT tests use Doppler ultrasound and require a trained operator and specialized equipment, restricting its use in the field. BeatScope (Finapres Medical Systems BV, The Netherlands) uses a modelflow algorithm to estimate SV from continuous blood pressure waveforms in supine subjects; however, evidence supporting the use of Modelflow to estimate SV in subjects completing stand or HUT tests remain scarce. Furthermore, because the blood pressure device is held extended at heart level during HUT tests, but allowed to rest at the side during stand tests, changes in the finger arterial pressure waveform resulting from arm positioning could alter modelflow estimated SV. The purpose of this project was to compare Doppler ultrasound and BeatScope estimations of SV to determine if BeatScope can be used during stand or HUT tests. Finger photoplethysmography was used to acquire arterial pressure waveforms corrected for hydrostatic finger‐to‐heart height using the Finometer (FM) and Portapres (PP) arterial pressure devices in 10 subjects (5 men and 5 women) during a stand test while simultaneous estimates of SV were collected using Doppler ultrasound. Measures were made after 5 minutes of supine rest and while subjects stood for 5 minutes. Next, SV estimates were reacquired while each arm was independently raised to heart level, a position similar to tilt testing. Supine SV estimates were not significantly different between all three devices (FM: 68+/-20, PP: 71+/-21, US: 73+/-21 ml/beat). Upon standing, the change in SV estimated by FM (‐18+/-8 ml) was not different from PP (‐21+/-12), but both were significantly less than US (‐37+/-16 ml, p<.05). Raising finger BP devices to heart level caused no significant change in SV measured with any of the devices (FM: 1.5+/-19, PP: 1.7+/-26, US: 0.5+/-6), although variability was 3‐6x greater as assessed by both blood pressure devices compared to US. Retrospective analysis of blood pressure data to assess SV in 11 supine subjects revealed significantly different estimates between methods (FM: 95+/-17, US: 75+/-32, p<.05), but the change in SV resulting from HUT was similar between methods (FM: ‐37+/-9, US: ‐40+/-18 ml). However, the correlation coefficient determined from pairs of SV estimated by US and FM was weak (r2=0.03). These data suggest Modelflow cannot be used in lieu of Doppler ultrasound to estimate SV during stand or HUT tests. Further investigation should focus on identifying factors contributing to differences between these measurement techniques in order to make use of a simple method for assessing beat‐by‐beat changes in SV during postural changes, especially during field testing.

Ferguson, Connor R.↗

Improving Sensorimotor Adaptation Following Long Duration Space Flight by Enhancing Vestibular Information Transfer

Crewmember adapted to the microgravity state may need to egress the vehicle within a few minutes for safety and operational reasons after gravitational transitions. The transition from one sensorimotor state to another consists of two main mechanisms: strategic and plastic-adaptive and have been demonstrated in astronauts returning after long duration space flight. Strategic modifications represent "early adaptation" - immediate and transitory changes in control that are employed to deal with short-term changes in the environment. If these modifications are prolonged then plastic-adaptive changes are evoked that modify central nervous system function, automating new behavioral responses. More importantly, this longer term adaptive recovery mechanism was significantly associated with their strategic ability to recover on the first day after return to Earth G. We are developing a method based on stochastic resonance to enhance information transfer by improving the brain's ability to detect vestibular signals (Vestibular Stochastic Resonance, VSR) especially when combined with balance training exercises such as sensorimotor adaptability (SA) training for rapid improvement in functional skill, for standing and mobility. This countermeasure to improve detection of vestibular signals is a stimulus delivery system that is wearable/portable providing low imperceptible levels of white noise based binaural bipolar electrical stimulation of the vestibular system (stochastic vestibular stimulation). To determine efficacy of vestibular stimulation on physiological and perceptual responses during otolith-canal conflicts and dynamic perturbations we have conducted a series of studies: We have shown that imperceptible binaural bipolar electrical stimulation of the vestibular system across the mastoids enhances balance performance in the mediolateral (ML) plane while standing on an unstable surface. We have followed up on the previous study showing VSR stimulation improved balance performance in both ML and anteroposterior planes while stimulating in the ML axis only. We have shown the efficacy of VSR stimulations on enhancing physiological and perceptual responses of whole-body orientation during low frequency perturbations (0.1 Hz) on the ocular motor system using a variable radius centrifuge on both physiological (using eye movements) and perceptual responses (using a joystick) to track imposed oscillations. The variable radius centrifuge provides a selective tilting sensation that is detectable only by the otolith organs providing conflicting information from the canal organs of the vestibular system (intra-vestibular conflict). These results indicate that VSR can improve performance in sensory conflict scenarios like that experienced during space flight. We have showed the efficacy of VSR stimulation to improve balance and locomotor control on subjects exposed to continuous, sinusoidal lateral motion of the support surface while walking on a treadmill while viewing perceptually matched linear optic flow. We have shown the safety of short term continuous use of up to 4 hours of VSR stimulation and its efficacy in improving balance and locomotor function in Parkinson's Disease patients. This technique for improving vestibular signal detection may thus provide additional information to improve strategic abilities. We hypothesize that VSR stimulation will act synergistically with SA training to improve adaptability by increased utilization of vestibular information and therefore serve to optimize and personalize the SA countermeasure prescription. This forms the basis of its usefulness both as a training modality and further help in significantly reducing the number of days required to recover functional performance to preflight levels after long duration space flight.

Mulavara, A. P.↗

A Science-Focused Artificial Intelligence (AI) Responding in Real-Time to New Information: Capability Demonstration for Ocean World Missions

Introduction: Artificial intelligence (AI) has long been considered a potential mechanism to explore increasingly challenging environments, including those with extreme temperatures and pressures, limited communication capabilities, or those with demanding terrain. We posit that missions in extreme environments could deploy an onboard AI focused on science observations and goals in order to augment a traditional concept(s) of operations (ConOps). An onboard AI capability could perform functions such as data analysis in order to make high-level decisions, including prioritized data transmission for analysis by ground-based teams or autonomously-guided follow-on analyses that maximize science return. Such a capability would empower missions to respond to scientific data of interest in real-time; a mission could make observations and perform a preliminary analysis to alert ground-based scientists to an observation of interest, enabling an informed, rapid response from Earth-based teams. Enceladus Case Study for Onboard AI: We are developing an onboard AI capability for real-time telemetry response that formulates and carries-out informed decisions in service to established mission goals, enabling increased science return of a mission. We focus our AI development for use on a constellation of SmallSats orbiting Enceladus. Our Enceladus case study tests autonomous decision-making capabilities in scenarios with complex orbital dynamics, plume ejecta, extreme cold environments, power restrictions, and a requirement to maximize science return for a potential positive detection of life, while critically evaluating the potential for false positives. Telemetry includes simulated scientific data, spacecraft onboard operational data (e.g., position, velocity, and rotation), and engineering hardware performance data. Enceladus SmallSat Constellation. Our constellation includes eight SmallSat spacecraft in an 8:35 resonant orbit-based formation, leveraging Saturn’s gravitational forces to maintain stable orbits with global coverage around Enceladus. To our knowledge, we simulate the first stable configuration of multiple spacecraft in closed orbits around Enceladus, using a full ephemeris force model (Russell and Lara, 2009). Each spacecraft’s orbit will precess, causing an eastward ground track shift (from an orbiter’s perspective) of each spacecraft for each orbit. However, all spacecraft return to their original positions relative to Enceladus after eight Enceladus revolutions around Saturn. We model communication pathways between SmallSats to understand how information would need to be transmitted across the constellation to enable AI-driven decision-making and resource allocation across the fleet. Capability Demonstration. Our simulated capability demonstration inputs position, velocity, and rotation telemetry from our Enceladus-focused constellation simulations, and mass spectrometry data collected from abiotic and biotic laboratory-analog ocean world experiments (Theiling et al., 2018; Theiling, 2021; Da Poian et al., 2023). Data from these experiments are used to simulate MS measurements and different scenarios of science observations for onboard analysis performed on each of the eight spacecraft. For these demonstrations, we integrate 24 machine learning (ML) algorithms into an onboard intelligence as a ‘knowledge base’, including algorithms evaluating data quality and those predicting (with % confidence) gas composition, ocean aqueous chemistry, and whether the sample was influenced by microbial life. The onboard AI capability is designed to use the knowledge base to come to a consensus-based decision in the interpretation of the observed data in order to request additional action outside of a pre-defined ConOps. Requested actions could include e.g., prioritized downlink to Earth (for analysis by ground-based teams) or follow-on analyses performed across the constellation. The spacecraft’s intelligent onboard planner must then determine whether sufficient resources (e.g., time, power, etc.) are available and weigh the request with mission priorities. In our simulation, the constellation is able to identify potential biosignatures using onboard ML algorithms, evaluate the confidence of that prediction, and perform follow-on analyses across the fleet to confirm the detection, in order to best prepare a transmission of these data to Earth-based teams.

astrobiology↗

Does Collection Time Bias the Ecology of Cleanroom Air Samples?

Microbial monitoring of astromaterials collections has taken on increased importance with the return of biologically sensitive samples from the asteroids Ryugu and Bennu and the initiation of the Mars Sample Return Program. Terrestrial bacteria and fungi can alter the mineralogy and organic composition of our collections causing irreversible contamination of pristine samples and increasing the risk of false positives for life detection measurements. NASA has conducted routine microbial monitoring of its existing collections since 20181. Initial monitoring focused on surface samples collected with foam swabs. Although, airborne microbiology is often decoupled from surface microbiology in the built environment2 culture-based air sampling techniques like impactors were not compliant with existing contamination control requirements. Bringing organic rich media, gelatin or liquids into curation cleanrooms presents an unacceptable risk to pristine samples. In 2022 NASA purchased a materials complaint air sampler and began collecting air samples from the cleanrooms in addition to surface samples3. The new instrument uses an electret filter to collect samples that are suitable for cultivating organisms or for direct DNA sequencing. Preliminary DNA sequencing results appeared to indicate that longer sampling times biased the microbial community in favor of hearty, spore-forming bacteria3. We present the results of a study comparing overnight sampling (17 hours) to short (1 hour) sampling of unoccupied curation cleanrooms. The results will help us optimize our monitoring protocols and develop a more detailed inventory of the ecology of astromaterials curation cleanrooms. Methods: We analyzed 72 paired air samples from six different cleanrooms including the meteorite processing lab (ISO 7 equivalent, 16 samples), the lunar lab (ISO 6 equivalent, 10 samples), the stardust lab (ISO 5 equivalent 14 samples), the OSIRIS-REx lab (ISO 5 equivalent, 12 samples), the Hayabusa2 lab (ISO 5 equivalent, 14 samples), and the Genesis lab (ISO 4 equivalent, 6 samples). All the samples were collected with an InnovaPrep Bobcat air sampler operating at a sampling rate of 200 L/min. The sampler operates for 5 minutes out of every 20 minute period. Half of the samples were collected by filtering 3,000L (15 min. of active sampling) of air across an electret filter for one hour. The rest of the samples were collected by filtering approximately 51,000 L air across the filter overnight (~17 hours, 255 min. of active sampling). Cells were eluted from the filter using 6-7 ml of pressurized 0.15% tween 20 in PBS (phosphate buffered saline). This liquid was used to cultivate bacteria according to previously published methods1,4,5 and for DNA extraction and next generation sequencing. DNA was extracted with a Qiagen MagAttract PowerMicrobiome kit6. To identify bacteria and archaea, the 16S rRNA gene was amplified using Earth Microbiome primers for the V4 region 7. The amplified DNA was sequenced on an Illumina MiSeq using a V3 reagent kit. The resulting sequences were processed using DADA2 and QIIME2 as implemented on the EDGE bioinformatics platform8–10. Results: Only two of the 72 samples had no amplifiable DNA. Amplified DNA concentrations ranged from 2.67 – 0.272 ng/µl. The median concentration of amplified DNA for the 1 hour samples was 0.770 ± 0.368 ng/µl. The median concentration of amplified DNA for the overnight samples was 0.877 ± 0.434 ng/µl. On average the overnight samples had slightly more sequences (58,960 vs. 59,456) and ASV’s (amplicon sequence variants) (60 vs 64.5) than the one hour samples, but these differences are not statistically significant. The most abundant ASV in every sample mapped to the genus Cupravidus. ASV’s mapping to the genuses Bacillus, Schlegelella, Thermus, and Staphylococcus were also common. Discussion and Future Work: Alpha diversity statistics like Shannon Entropy and Faith Phylogenetic Diversity are used to describe the diversity of organisms in a single sample. If a longer sampling time was biasing the data, we would expect to see a change in these diversity statistics vs. sample time. However, we did not observe this in our data. The median Shannon entropy was slightly higher for the overnight samples (3.773 vs 3.611) as was the Faith Phylogenetic Diversity (4.042 vs 3.596), but both values were within a standard deviation of each other for the two sampling times (Fig. 1). It is unlikely, that the longer sampling time is introducing bias into our data. We do observe a significant decrease in diversity when comparing the air samples by lab. The Genesis lab (ISO 4 equivalent) has a lower median number of ASV’s (45.5) than the other labs (62). Median values for Shannon Entropy (3.717 vs. 3.430) and Faith Phylogenetic Diversity (3.796 vs. 3.548) are also lower for Genesis, but those values are with one standard deviation of each other for the different sampling times. This is consistent with previous culture-based results suggesting that the environment in cleanrooms tends to select for a core group of organisms capable of surviving under dry, low nutrient, conditions. The presence of the ASV’s mapping to Cupravidus and Thermus in our sequencing blanks and controls suggests that several of the most common organisms in our samples represent contaminants from the reagents used to perform the DNA extractions and sequencing. Further work is needed to identify these contaminants, remove them from our data and recalculate the diversity statistics. This is a systematic error. Therefore, we do not expect removing the sequencing contaminants to change our conclusions. Longer air sample collection times appear to result in slightly higher diversity and do not bias the results towards “hardy” bacteria like spore-formers. Based on these preliminary results we conclude that sampling at least 3,000 liters of air is sufficient to capture the microbial diversity of cleanrooms, and that air samples can also be collected overnight without negatively impacting diversity. These results allow us to be flexible when designing microbial monitoring plans so that they do not interfere with routine lab activity. References: 1. Regberg, A. B. et al. 49th Lunar and Planetary Science Conference (2018). 2. The United States Pharmacopeial Convention. USP General Chapter <1116> (2013). 3. Regberg, A. B., et al. 54th Lunar and Planetary Science Conference (2023). 4. Regberg, A. B. et al. 53rd Lunar and Planetary Science Conference ( 2022). 5. Davis, R. E.,et al. 50th Lunar and Planetary Science Conference (2019). 6. Qiagen. MagAttract® PowerMicrobiome® DNA/RNA EP Kit Handbook. (2018). 7. Walters, W. et al. mSystems 1, (2015). 8. Callahan, B. J. et al. Nat. Methods 13, 581–583 (2016). 9. Hall, M. & Beiko, R. G. Microbiome Analysis: Methods and Protocols113–129 (Springer, 2018). 10. Philipson, C. et al. Bio-Protoc. 7, e2622 (2017).

A. B. Regberg↗

Microbial Monitoring of New Cleanrooms Used to Curate Astrobiologically Relevant Asteroid Samples from Bennu and Ryugu

Introduction: NASA has constructed two new cleanrooms to house materials from the OSRIS-REx and Hayabusa2 missions to the asteroids Ryugu (162173) and Bennu (101955), respectively. In accordance with standard astromaterials curation practices, these cleanrooms will be monitored for particulate contamination and maintained to ISO 5 equivalent standards1. Since the samples in these collections are expected to contain prebiotic organic compounds that may help explain the origin of life on Earth, these labs will also be monitored for organic and biological contamination2. Samples from Ryugu arrived on Earth in December, 2020. After basic characterization in Japan, NASA received a subset of these samples at the astromaterials curation facility in Houston in December of 2021. OSIRIS-REx is expected to return samples in September, 2023. Here we present preliminary microbial monitoring results from monthly monitoring of these new labs and the connected microtomy and staging areas that support them, as they are being commissioned. We also compare these results to baseline values for other astromaterials curation labs. We will also briefly describe additional cleaning efforts employed to reduce the bioburden in these new cleanrooms. Methods: Microbial samples were collected from surfaces using a dry macrofoam swab (Puritan Brand 2518051PFRNDFD). Swabs were also opened in the lab but not touched to any surfaces to function as negative controls. Samples and controls were processed inside a class II biosafety cabinet to avoid inadvertent cross contamination. The swabs were suspended in 15 ml of PBS (Phosphate Buffered Saline) and vortexed for 20 seconds to remove cells from the swab surface. The PBS was used to inoculate Petri dishes filled with TSA (Tryptic Soy Agar), Blood Agar, or Reasoners 2 agar to check for microbial growth. Each plate was inoculated with 0.1 ml of PBS. The TSA and blood agar plates were incubated at 35˚C and the Reasoners 2 agar plates were incubated at 25˚C for seven days. Petri dishes filled with Potato dextrose agar, Saboraud dextrose agar, or Saboraud dextrose agar with 0.1 mg/ml of chloramphenicol, an antibiotic, were used to check for fungal growth. These plates were inoculated with 0.3 ml of PBS and incubated at 30˚C. The remaining PBS was frozen at -80 ˚C for DNA sequencing. After incubation, isolates were counted and reisolated for identification. Isolates were identified using the VITEK23 system or by sequencing a portion of the 16S rRNA gene for bacteria or the ribosomal internal transcribed spacer (ITS) for fungi. Sequencing was performed with an ABI 3500 Sanger sequencer. Results: During our initial sampling, six of the seven sites sampled (86%) displayed bacterial or fungal growth. Samples collected from the staging areas and microtomy labs are not included in this calculation since those areas are maintained at a lower ISO 7 equivalent cleanliness standard. A month later, only three of the seven sites (43%) displayed bacterial growth. No fungal growth was detected in the second sampling. Since new equipment had been introduced to the Hayabusa2 lab since the first round of sampling, an additional three sampling sites were included in the second round of sampling. None of these sites displayed microbial growth. These sites will be included in all future sampling efforts. Bacterial isolates have been identified from the following genera at multiple time points: Micrococcus, Staphylococcus, and Bacillus. Isolates from the genera: Microbacterium, Nocardioides, Methylocystis, and Microvirga were identified in the initial sampling, but were not present at later time points. Identification of fungal isolates is in progress. Results are summarized in Table 1. Discussion: The recovery rate or percentage of positive samples4 was initially 86%, which is higher than the median recovery rate for comparable ISO 5 equivalent curation labs like Stardust (33%), Hayabusa (33%), and Cosmic Dust (50%). However, after a month of operation, the recovery rate for these same sites decreased to 43%, which is similar to what we observe in comparable curation cleanrooms with no microbial control requirements. Adding in the new sampling sites further decreases the recovery rate to 30%. With the reduction in recovery rate, we also observed a decrease in microbial diversity. At the first time point, we observed at least 10 different bacterial species and at least two different fungi. This is a higher diversity than the median values for comparable ISO 5 equivalent labs (2-4 isolates per sampling event). After the second sampling, we observed at least 4 bacterial species and no fungi, which is more consistent with comparable labs. We expect the recovery rate and diversity in both labs to continue to decrease as routine operation continues. We will use ultrapure hydrogen peroxide to disinfect equipment and work areas prior to opening any sample containers. Most of the bacterial and fungal isolates were detected on samples from the cleanroom floors. This is consistent with baseline results from other curation labs. Organisms from the genera Bacillus, Staphylococcus, and Micrococcus that were repeatedly detected are common in cleanrooms and on human skin5,6. These organisms are generally thought to be introduced when people enter the cleanroom. Microbacterium, Nocardioides, and Microvirga have also previously been identified in astromaterials cleanrooms, but not as frequently as Bacillus, Staphylococcus, and Micrococcus. Methylocystis is a novel genus in the astromaterials cleanrooms, but it was identified with low accuracy (93% match in the sequenced region of the 16S rRNA gene) and further work is needed to confirm this identification. Microbacterium is a diverse genus with isolates identified from terrestrial and aquatic sediments. Some species of Microbacterium are capable of degrading complex organic compounds found in crude oil. The presence of these bacteria in the OSIRIS REx and Hayabusa2 cleanrooms should be closely monitored. Methylocystis is a genus of methanotrophic bacteria capable of oxidizing methane. If this identification proves to be correct and it is detected again, it should be closely monitored as well. Under nominal operating conditions, samples should not ever encounter the cleanroom floor or other high traffic areas. If we observe an increase in the bioburden in sensitive work areas that appears to be influenced by organism transfer from high traffic areas like the floors, we can employ additional hydrogen peroxide treatments to disinfect high traffic areas. Routine microbial monitoring of these labs will ensure that NASA’s astromaterials collections remain pristine and useful for scientific study. Table 1. Sampling Locations and Colony Counts Bacterial CFUa Fungal CFU Bacterial CFU Fungal CFU Lab - Location 11/2/2021 11/2/2021 12/13/2021 12/13/2021 H2b-Floor 4 8 1 0 H2-staging pass through 3 0 0 0 H2-microtomy pass through TNTCc 0 0 0 H2 Microscope 1 NA NA 0 0 H2 Microscope 2 NA NA 0 0 H2-Table NA NA 0 0 OREXd- microtomy pass through 0 0 6 0 OREX – Anteroom pass through 0 0 0 0 OREX – Floor 1 2 0 0 OREX Witness Foil Table 3 0 1 0 Staging-Floor 16 0 15 0 Microtomy-Floor 3 0 2 0 a: CFU = Colony Forming Unit b: H2 = Hayabusa2 Lab c: TNTC = too numerous to count d: OREX = OSIRIS-REx Lab References: 1. ISO 14644-1:2015 - Cleanrooms and associated controlled environments -- Part 1: Classification of air cleanliness by particle concentration. 37 (2015). 2. McCubbin, F. M. et al. Space Sci Rev 215, (2019). 3. Pincus, D. H. Encyclopedia of Rapid Microbiological Methods (2005). 4. The United States Pharmacopeial Convention. USP General Chapter <1116> 17, 784–794 (2013). 5. Sheraba, N. S., Yassin, A. S. & Amin, M. BMC Research Notes 3, 278 (2010). 6. Utescher, C. L. de A., Franzolin, M. R., Trabulsi, L. R. & Gambale, V. Brazilian Journal of Microbiology 38, 710–716 (2007).

A B Regberg↗

In-Lab Rapid Analytical Detection of Lunar Volatiles By Universal Gas Analyzer With Comparison to GC-MS System

Introduction: The curation of permanently shadowed regions (PSRs) [1] on the lunar surface is centered around studies based upon the observed volatiles from the LCROSS mission [2]. The rapid detection of important volatile gases and vapors present in planetary bodies and Astromaterials by a standalone analytical device is an area of intense research interest in our group and Planetary Exploration & Astromaterials Research Laboratory (PEARL) facility and this work is relevant to the future preparation of viable lunar simulants for testing curation efforts down the road. The groundbreaking results obtained from the LCROSS Mission [2] open the requirements for the direct detection of volatiles present in regolith materials collected from the lunar surface. The mass spectrometry of volatile chemicals is a general technique that utilizes a set of instruments that creates charged ions from a gaseous chemical species and measures the intensities vs. mass-to-charge ratio (m/z) [3]. In this context, we discuss in-lab experimental results and procedures for rapid qualitative analysis of main LCROSS volatiles (water, H2S, NH3, CO2, and CH3OH) by a Universal Gas Analyzer (UGA) instrument. Additionally, the instrument performance was evaluated by measuring the isotopic abundance ratio of atmospheric Ar-40 to Ar-36 present in room air since, argon is a relevant gas in planetary studies as it can provide an insight and reference point to isotope studies [4]. Additional, cross comparisons were attempted and made between the two instruments to develop a robust analytical technique by comparing mass spectral data for H2S headspace samples with a Trace-1310/ ISQ 7000 (ThermoFisher Scientific.) GC-MS system. Background: The benchtop UGA System is equipped with an SRS UGA 300 quadrupole mass spectrometer designed and built by Stanford Research Systems [5]. This system can be configured for several types of gaseous chemical analysis. The inlet line continuously samples gases at low flow rates (several milliliters per minute) through a capillary limiting the intake pressure making the instrument ideal for online analysis of select gases and/or room atmosphere. Moreover, in our current UGA system, a change in composition at the inlet can be detected in about 200 milliseconds and a complete spectrum is acquired (for a range of 1-100 amu) in under 45 sec with masses measured at rates up to 25 msec per point [5]. This system provides a quick upstream analytical data that we can then compare to results obtained by our GC-MS system. Sample Preparation: Small volume (2-4 mL) of analyte sample was taken in a 10 mL glass vial and sealed with a crimped cap and purged with pure Ar or N2 gas to displace air from the top. The headspace sample was scanned by the UGA instrument at analog, histogram, and pressure vs. time modes. The isotopic abundance ratio for 40Ar-to-36Ar was estimated by measuring partial pressure vs. time scans and setting the mass at 40 and 36 respectively. Results and Discussions: In this work, we have investigated the applicability of the UGA system by qualitative analysis of a series of LCROSS volatiles measured individually. Fig. 1 demonstrates a set of vertically offset spectra for the partial pressures measured as a function of mass-to-charge (m/z) ratios. The average acquisition time for each spectrum was less than a minute suggesting that the UGA system is ideal for quick analysis of geochemical volatiles. For the cross-comparison, we analyzed an H2S headspace sample by a Trace-1310/ISQ-7000 system and compared mass spectral data with previously measured UGA histogram scan data (Fig. 2). In both cases, major peak positions are the same, however, the intensities of fragment ions ([1H132S]+ and [32S]+) are higher for UGA suggesting that the fragment ionization process is stronger in UGA compared to that of GC-MS. To investigate how the integrated area under each chromatogram varies with the headspace sample volume, a set of five H2S headspace samples with increasing volumes was analyzed by the GC-MS system (Fig. 3, inset). A small volume (e.g., 200 to 1000 µL) of H2S/H2O vapor was withdrawn from a 20 mL stock sample vial containing ~5 mL of 0.4% H2S in water by a gas-tight syringe and added to another 20 mL vial filled with argon and analyzed by the GC-MS system. Finally, the UGA detector sensitivity was evaluated by calculating the atmospheric 40Ar-to-36Ar isotopic abundance ratio in room air by running a partial pressure vs. time scan with setting the atomic mass at 40, and 36. Fig. 4(a) shows a ~25 min duration “P vs. time” scan for 40Ar (plot for 36Ar is not shown). The partial pressure values (~100 points) were corrected by subtracting the corresponding background pressure value for 37Ar and utilized to calculate 40Ar-to-36Ar isotopic abundance ratios as shown by Fig. 4b. The average isotopic abundance ratio is ~306 with a 2*STDEV ~13. This abundance ratio is significantly close to the previously reported value of 298.56 [6] and the ratio obtained by our GC-MS system (303 for a UHP grade Ar sample). Conclusions: Our study strongly evidenced that the benchtop UGA system is a valuable analytical tool for the detection of major LCROSS volatiles. The rapid scanning capability, the inexpensiveness of the whole system, and impressive detection sensitivity prove its worthiness as an essential device for advanced geochemical applications. Moreover, cross comparisons with the GC-MS provide important bridges into advanced curatorial efforts into the future. References: [1] Bickel, V.T., et al. (2021) Nat Commun 12, 5607. [2] Colaprete, A., et al. (2010) Science, 330, 463-468. [3] Glavin, D. P. et al. (2012) 2012 IEEE Aerospace Conference, 1-11. [4] Willett, C. D., et al. (2022) Geochimica et Cosmochimica Acta 329, 119-134. [5] Operation Manual and Programming Reference. (2018) Universal gas Analyzers, Stanford Research Systems. [6] Lee, J. Y., et al. (2006) Geochimica et Cosmochimica Acta 70, 4507–4512. Notes: (4 figures are attached with text as shown by the attached file)

Curation↗