Search NASA⌕ Search

SEARCH · Search NASA

Results for “MULTIPLIER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Silicon Photo-Multiplier Readouts for Scintillators in High-Energy Astronomy

New scintillator materials have recently been shown to hold great potential for low-cost, reliable gamma-ray detectors in high-energy astronomy. New devices for the detection of scintillation light promise to make scintillator-based instruments even more attractive by reducing mass and power requirements,in particular, silicon photo-multipliers (SiPMs) are starting to become commercially available that offer gains and quantum efficiencies similar to those of photo-multiplier tubes (PMTs), but with greatly reduced mass, high ruggedness, low voltage requirements, and no sensitivity to magnetic fields. We have conducted laboratory tests of a sample of commercially available SiPMs coupled to LaBr3;Ce, a scintillator of relevance to to future high-energy astrophysics missions. We present results for gamma-ray spectroscopy. compare the SiPM performance to that of a PMT, and discuss the extent to which SiPMs offer significant advantages for scintillator-based space missions.

Bloser, Peter F.↗

On-Chip Power-Combining for High-Power Schottky Diode-Based Frequency Multipliers

A 1.6-THz power-combined Schottky frequency tripler was designed to handle approximately 30 mW input power. The design of Schottky-based triplers at this frequency range is mainly constrained by the shrinkage of the waveguide dimensions with frequency and the minimum diode mesa sizes, which limits the maximum number of diodes that can be placed on the chip to no more than two. Hence, multiple-chip power-combined schemes become necessary to increase the power-handling capabilities of high-frequency multipliers. The design presented here overcomes difficulties by performing the power-combining directly on-chip. Four E-probes are located at a single input waveguide in order to equally pump four multiplying structures (featuring two diodes each). The produced output power is then recombined at the output using the same concept.

Chattopadhyay, Goutam↗

THz multiplier circuits

Planar Schottky diode technology has been utilized to fabricate high-power broad-band monolithic multiplier circuits that can produce appreciable power well into the THz range. The chip fabrication technology that has been developed allows for robust circuit designs that can be easily packaged in conventional waveguide blocks. An overview of the capability of GaAs based Schottky diode multipliers will be presented.

Maestrini, A.↗

Integrated optic vector-matrix multiplier

A vector-matrix multiplier is disclosed which uses N different wavelengths of light that are modulated with amplitudes representing elements of an N.times.1 vector and combined to form an input wavelength-division multiplexed (WDM) light stream. The input WDM light stream is split into N streamlets from which each wavelength of the light is individually coupled out and modulated for a second time using an input signal representing elements of an M.times.N matrix, and is then coupled into an output waveguide for each streamlet to form an output WDM light stream which is detected to generate a product of the vector and matrix. The vector-matrix multiplier can be formed as an integrated optical circuit using either waveguide amplitude modulators or ring resonator amplitude modulators.

42 ENGINEERING↗

A Domain-Decomposed A-ϕ Formulation Based on Lagrange Multipliers for Low-Frequency Problems

A domain-decomposed A-ϕ formulation based on Lagrange multipliers is proposed to simulate low-frequency elec- tromagnetic problems. This method partitions the computational domain into smaller subdomains, allowing each subdomain to be independently formulated using Lagrange multipliers as Dirichlet boundary conditions, while ensuring continuity of the fields across the interfaces. A mixed finite element method, utilizing both vector and scalar basis functions, is employed to discretize the formulation, resulting in a global system to be solved. The proposed method is validated using TEAM Problem 7 at 50 Hz, demonstrating its effectiveness in handling complex geometries and addressing the low-frequency breakdown issues commonly encountered in traditional finite element methods.

Hossain, Amzad↗

Measurement Of Gas Electron Multiplier (GEM) Detector Characteristics

The High Energy Physics group of the University of Texas at Arlington has been developing gas electron multiplier detectors to use them as sensitive gap detectors in digital hadron calorimeters for the International Linear Collider, a future high energy particle accelerator. For this purpose, we constructed numerous GEM detectors that employ double GEM layers. In this study, two kinds of prototype GEM detectors were tested; one with 28x28 cm{sup 2} active area double GEM structure with a 3 mm drift gap, a 1 mm transfer gap and a 1 mm induction gap and the other with two 3x3 cm{sup 2} GEM foils in the amplifier stage with a 5 mm drift gap, a 2 mm transfer gap and a 1 mm induction gap. The detectors' characteristics from exposure to high-energy charged particles and other radiations were measured using cosmic rays and {sup 55}Fe radioactive source. From the {sup 55}Fe tests, we observed two well separated characteristic X-ray emission peaks and confirmed the detectors' functionality. We also measured chamber gains to be over 6000 at a high voltage of 395 V across each GEM electrode. The responses to cosmic rays show the spectra that fit well to Landau distributions as expected from minimum ionizing particles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Effect On Gas Electron Multiplier Detector Performance

Gas Electron Multiplier (GEM) detector is a gas device with high gain and high efficiency. These detectors use chemically perforated 65 {mu}m thick copper clad Kapton polyimide foils. Given its potential for detecting X-rays and other radiations, GEM detectors may be used in an environment with high radioactivity. The Kapton foils manufacturer, Du Pont Inc., claims that the foils are radioactive resistant. To verify whether the GEM detector performance is affected by the exposure to radiation, several GEM foils were irradiated to a {sup 60}Co source at the gamma-ray irradiation facility at Sterigenics, Tustin, CA. Four sets of GEM foils were exposed to the level of 10 kGy, 100 kGy, 1,000 kGy and 10,000 kGy. The output signal from the GEM detectors with irradiated GEM foils were measured and compared to the detector with no irradiation. We observed that the shapes of the peaks from 5.9 KeV {sup 55}Fe X-ray were distorted and that the detector gain increased compared to that of the un-irradiated detector. In particular, the detector with 10,000 kGy irradiation appeared to have the biggest peak distortion and increased gain. It was also found from that additional electrons from radiation-induced free radicals in the Kapton film contribute to output signal of the irradiated GEM detectors. Further studies are needed to explain the mechanism of these detector performance changes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a cold-neutron imaging detector based on thick gaseous electron multiplier

We present the results of our recent studies on a cold-neutron imaging detector prototype based on THick Gaseous Electron Multiplier (THGEM). The detector consists of a thin Boron layer, for neutron-to-charged particle conversion, coupled to two THGEM electrodes in cascade for charge amplification and a position-sensitive charge-readout anode. The detector operates in Ne/(5%)CF{sub 4}, at atmospheric pressure, in a stable condition at a gain of around 10{sup 4}. Due to the geometrical structure of the detector elements (THGEM geometry and charge read-out anode), the image of detector active area shows a large inhomogeneity, corrected using a dedicated flat-filed correction algorithm. The prototype provides a detection efficiency of 5% and an effective spatial resolution of the order of 1.3 mm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

THz frequency multiplier chains base on planar Schottky diodes

The Herschel Space Observatory (HSO), an ESA cornerstone mission with NASA contribution, will enable a comprehensive study of the galactic as well as the extra galactic universe. At the heart of this exploration are ultra sensitive coherent detectors that can allow for high-resolution spectroscopy. Successful operation of these receivers is predicated on providing a sufficiently powerful local oscillator (LO) source. Historically, a versatile space qualified LO source for frequencies beyond 500 GHz has been difficult if not impossible. This paper will focus on the effort under way to develop, build, characterize and qualify a LO chain to 1200 GHz (Band 5 on HSO) that is based on planar GaAs diodes mounted in waveguide circuits. State-of-the-art performance has been obtained from a three-stage ( x2 x 2 x 3 ) multiplier chain that can provide a peak output power of 120 uW (1178 GHz) at room temperature and a peak output power of 190 uW at 1183 GHz when cooled to 113 K. Implementation of this LO source for the Heterodyne Instrument for Far Infrared (HIFI) on HSO will be discussed in detail.

oscillator spectroscopy↗

An embedded mesh method using piecewise constant multipliers with stabilization: mathematical and numerical aspects

An embedded mesh method using piecewise constant multipliers originally proposed by Puso et al. (CMAME, 2012) is analyzed here to determine effects of the pressure stabilization term and small cut cells. The approach is implemented for transient dynamics using the central difference scheme for the time discretization. It is shown that the resulting equations of motion are a stable linear system with a condition number independent of mesh size. Furthermore, we show that the constraints and the stabilization terms can be recast as non-proportional damping such that the time integration of the scheme is provably stable with a critical time step computed from the undamped equations of motion. Effects of small cuts are discussed throughout the presentation. A mesh study is conducted to evaluate the effects of the stabilization on the discretization error and conditioning and is used to recommend an optimal value for stabilization scaling parameter. Several nonlinear problems are also analyzed and compared with comparable conforming mesh results. Finally, we show several demanding problems highlighting the robustness of the proposed approach.

42 ENGINEERING↗

Projective Representations, Bogomolov Multiplier, and Their Applications in Physics

We present a pedagogical review of projective representations of finite groups and their physical applications in quantum many-body systems. Some of our physical results are new. We begin with a self-contained introduction to projective representations, highlighting the role of group cohomology, representation theory, and classification of irreducible projective representations. We then focus on a special subset of cohomology classes, known as the Bogomolov multiplier, which consists of cocycles that are symmetric on commuting pairs but remain nontrivial in group cohomology. Such cocycles have important physical implications: they characterize (1+1)D SPT phases that cannot be detected by string order parameters and give rise, upon gauging, to distinct gapped phases with completely broken non-invertible Rep(G) symmetry. We construct explicit lattice models for these phases and demonstrate how they are distinguished by the fusion rules of local order parameters. We show that a pair of completely broken Rep(G) SSB phases host nontrivial interface modes at their domain walls. As an example, we construct a lattice model where the ground state degeneracy on a ring increases from 32 without interfaces to 56 with interfaces.

Bogomolov multiplier↗

Decentralized wind uncertainty management: Alternating direction method of multipliers based distributionally-robust chance constrained optimal power flow

How to manage wind power uncertainty in system operation is an urgent and important issue, especially under substantially increasing penetration levels of wind generation in electric power systems. With increasing numbers of wind power plants (WPPs) integrated into power systems, their variability and uncertain power outputs become a challenge to maintaining system reliability. Traditional stochastic optimization-based models face the curse of dimensionality when the number of WPPs increases. This paper proposes a novel decentralized wind power uncertainty management model. In this model, conventional generators optimize their power capacity output and their participation to mitigate wind power uncertainty locally with only limited information exchange with the system operators. First, a distributionally-robust chance-constrained optimal power flow (DRCC-OPF) model is deployed to schedule the generation and reserve considering the wind power forecast uncertainty. Then, the alternating direction method of multipliers (ADMM) is used to reformulate the DRCC-OPF model into the distributed optimization model for each conventional generator and WPP. The tests on a small PJM 5-bus system and the IEEE 118-bus system demonstrate that the proposed decentralized model can increase the operation reliability without sacrificing system operating cost, especially when the wind power penetration levels are high. Using the proposed model, the optimal solutions can be obtained within one minute, for all studied cases, which verifies the computation efficiency of the proposed decentralized model. Furthermore, considering a large number of WPPs integrated into the system, the proposed decentralized method obtains a lower operating cost within one minute which demonstrates its efficiency to deal with high dimension of uncertainties.

17 WIND ENERGY↗

Gaseous electron multiplier-based soft x-ray plasma diagnostics development: Preliminary tests at ASDEX Upgrade

A Gaseous Electron Multiplier (GEM)-based detector is being developed for soft X-ray diagnostics on tokamaks. Its main goal is to facilitate transport studies of impurities like tungsten. Such studies are very relevant to ITER, where the excessive accumulation of impurities in the plasma core should be avoided. This contribution provides details of the preliminary tests at ASDEX Upgrade (AUG) with a focus on the most important aspects for detector operation in harsh radiation environment. It was shown that both spatially and spectrally resolved data could be collected, in a reasonable agreement with other AUG diagnostics. Contributions to the GEM signal include also hard X-rays, gammas, and neutrons. First simulations of the effect of high-energy photons have helped understanding these contributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparative Response of Microchannel Plate and Channel Electron Multiplier Detectors to Penetrating Radiation in Space

Channel electron multiplier (CEM) and microchannel plate (MCP) detectors are routinely used in space instrumentation for measurement of space plasmas. Here, our goal is to understand the relative sensitivities of these detectors to penetrating radiation in space, which can generate background counts and shorten detector lifetime. We use 662 keV γ-rays as a proxy for penetrating radiation such as γ-rays, cosmic rays, and high-energy electrons and protons that are ubiquitous in the space environment. We find that MCP detectors are ~20 times more sensitive to 662 keV γ-rays than CEM detectors. This is attributed to the larger total area of multiplication channels in an MCP detector that is sensitive to electronic excitation and ionization resulting from the interaction of penetrating radiation with the detector material. In contrast to the CEM detector, whose quantum efficiency ε γ for 662 keVγ -rays is found to be 0.00175 and largely independent of detector bias, the quantum efficiency of the MCP detector is strongly dependent on the detector bias, with a power law index of 5.5. Lastly, background counts in MCP detectors from penetrating radiation can be reduced using MCP geometries with higher pitch and smaller channel diameter.

79 ASTRONOMY AND ASTROPHYSICS↗

A Subterahertz Multiplier Based on a Traveling Wave Tube with a Sheet Electron Beam

In this paper, we present the results of the study of a multiplier based on a traveling wave tube with a sheet electron beam and slow-wave double-grating structures. Device configurations with the possibility of obtaining an output power above 60 W at the second harmonic frequency of 190 GHz with an input power of about 10 W at the first harmonic frequency were determined.

43 PARTICLE ACCELERATORS↗

Blind Ptychographic Phase Retrieval via Convergent Alternating Direction Method of Multipliers

Ptychography has risen as a reference X-ray imaging technique: it achieves resolutions of one billionth of a meter, macroscopic field of view, or the capability to retrieve chemical or magnetic contrast, among other features. A ptychographic reconstruction is normally formulated as a blind phase retrieval problem, where both the image (sample) and the probe (illumination) have to be recovered from phaseless measured data. In this article we address a nonlinear least squares model for the blind ptychography problem with constraints on the image and the probe by maximum likelihood estimation of the Poisson noise model. We formulate a variant model that incorporates the information of phaseless measurements of the probe to eliminate possible artifacts. Next, we propose a generalized alternating direction method of multipliers designed for the proposed nonconvex models with convergence guarantee under mild conditions, where their subproblems can be solved by fast el-ementwise operations. Numerically, the proposed algorithm outperforms state-of-the-art algorithms in both speed and image quality.

47 OTHER INSTRUMENTATION↗