At least 145 records · Page 8

Radiation Effects in Used Next Generation Nuclear Fuel Reprocessing Strategies

Given global commitments to significantly increase nuclear energy capacity, it is now more important than ever to develop efficient used nuclear fuel (UNF) management strategies to encourage widespread adoption of closed fuel cycles. To achieve this ambitious goal, a comprehensive understanding of radiation effects is essential for these next generation technologies, as radiolysis often limits longevity and performance. Here, we present new findings on: (i) the radiation robustness and performance of advanced sulfur chloride-based chlorination processes in the presence of nuclear materials (Fig. 1A); and (ii) the impacts of voloxidized uranium and rhenium complexation on monoamide-based UNF direct dissolution strategies (Fig 1B). These studies employed a combination of time-resolved electron pulse and dose accumulation gamma and electron beam irradiation techniques.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Grid-Interactive Efficient Buildings Support Federal Facility Decarbonization

The Federal Energy Management Program (FEMP) plays a key role in helping agencies understand and meet energy-related goals, including those surrounding smart buildings technologies and grid-interactive efficient buildings (GEBs), which can support decarbonization. GEB enables demand flexibility that has the potential to reduce electrical infrastructure costs and transform the grid edge, where buildings connect to the power grid.

decarbonization↗

Interface and Thermophysical Properties of R 32 Refrigerant

Driven by the urgent demand for efficient cooling in microelectronics and advanced thermal management systems, difluoromethane (R32/CH 2 F 2 ) has emerged as a promising candidate owing to its favorable thermophysical properties, including high heat transfer efficiency and low viscosity. While bulk properties such as density, viscosity, and thermal conductivity have been widely studied, interfacial properties, including surface tension and interfacial thickness, remain comparatively underexplored, despite their importance in phase-transition dynamics. Here, we perform molecular dynamics (MD) simulations from 180 to 300 K using an optimized transferable force field for fluoropropenes with enhanced electrostatics to assess both bulk and interfacial behavior of R32. Simulations reproduced density within ±2.1%, viscosity within 3.05%, and thermal conductivity within 7.41% of NIST reference data. Heat capacities (C p and C v ) were predicted within 5%. For interfacial properties, surface tension trends were reproduced within 13.58% deviation, and the vapor–liquid coexistence curve closely matched reference data, yielding a critical temperature of 345.7 K (1.6% deviation) and a critical density of 0.397 g/cm 3 (6.4% deviation). Importantly, the vapor–liquid interface exhibited pronounced temperature-dependent broadening across the 180–290 K range. This behavior correlates with increasing molecular kinetic energy, reduction in intermolecular cohesive interactions, and a progressive loss of preferential dipole alignment, which collectively enhance thermal fluctuation amplitudes at elevated temperatures. These validated results provide predictive molecular-level insights, particularly for interfacial properties that remain less characterized. By reducing property prediction errors in key parameters such as critical temperature, this work provides reliable inputs for heat-exchanger and system models. Such correlations can support optimized component sizing, improved performance, and reduced refrigerant charge. Beyond R32, the methodology offers a transferable framework for blended and next-generation low-GWP refrigerants, contributing to sustainable thermal management aligned with the 2027 EU F-Gas regulation and 2030 Kigali Amendment.

Fluids↗

Understanding Electric Vehicle Range and Charging Needs: Interactions Between Ambient Temperature, Commute Patterns, and State-of-Charge Usage

Electric vehicle (EV) performance can vary substantially under real-world operating conditions, particularly due to ambient temperature effects on energy consumption, battery behavior, and thermal management requirements. This study quantifies how weather conditions, daily driving patterns, and State-of-Charge (SOC) usage strategies jointly influence EV driving range, charging frequency, and overall energy efficiency. A detailed and experimentally validated Autonomie vehicle model is developed, integrating a powertrain, a mono-zonal cabin model, and a battery electro-thermal model. Three battery sizes (200-, 300-, and 400-mile homologated ranges) are assessed across five commute profiles (20–200 miles) and six ambient temperatures (−18 °C to 50 °C), including scenarios with and without preconditioning. Results show that extreme temperatures could significantly decrease the maximum achievable range by up to 55% in cold conditions (−18 °C) and 40% in hot conditions (50 °C), relative to moderate conditions. Larger battery packs retain a greater fraction of their nominal range under thermal stress, while smaller packs experience sharper relative penalties due to the higher contribution of thermal loads to total energy demand. The analysis further demonstrates that limiting operation to partial SOC windows (e.g., 80–20%), a common real-world practice, significantly reduces achievable range and increases charging frequency, particularly in cold weather. Thermal preconditioning while plugged in is shown to mitigate these effects for short trips, reducing energy consumption by up to 31% in hot conditions and 7% in cold conditions. The findings demonstrate how climate, SOC usage behavior, and thermal management jointly shape the practical driving capability of EVs, highlighting the importance of efficient thermal management and realistic user charging strategies for ensuring reliable EV operation across diverse climatic scenarios.

33 ADVANCED PROPULSION SYSTEMS↗

Efficient Dimension Reduction of Complex Three-dimensional CO2 Saturation using Deep Learning Models

In the domain of deep learning (DL), dimension reduction is crucial for enhancing training efficiency and mitigating overfitting, particularly when managing complex data such as three-dimensional (3D) saturation data. The 3D saturation data in the context of geological carbon storage (GCS) presents unique challenges due to its inherent sparsity and the abrupt transitions at plume boundaries, known as shock fronts. To address the challenges, we proposed a novel DL framework that integrates dimension reduction with advanced 3D reconstruction techniques. Our model leveraged latent variables derived from 2D average saturation data, offering a robust and efficient solution tailored to the intricate dynamics of 3D saturation fields. The proposed framework can extract the critical features of the high-dimensional data while reducing the variable numbers, which is more tractable for DL models and enhances the model robustness and accuracy. Therefore, it provides a novel approach for modeling and analyses in complex geological scenarios, which finds great potential applications in environmental monitoring and energy storage.

Wang, Hongsheng↗

AI Improves the Accuracy, Reliability, and Economic Value of Continental‐Scale Flood Predictions

Accurate flood early warnings are critical to minimize damage and loss of life. Current large‐scale operational forecasting systems, however, have limited accuracy, description of uncertainty, and computational efficiency. While Artificial intelligence (AI) can address these limitations in principle, the accuracy and reliability of AI forecasts have thus far proven insufficient. Here we present a novel hybrid framework that integrates AI‐based machinery termed Errorcastnet (ECN) with the National Water Model (NWM) to showcase the potential of ensemble AI flood forecasts over the contiguous U.S. ECN boosts prediction accuracy four‐ to six‐fold across lead times of 1–10 days, while providing uncertainty quantification. It also outperforms Google's state‐of‐the‐art global AI model. ECN‐based forecasts offer superior economic value (up to four‐fold) for decision‐making as compared to those from NWM alone. ECN performs well in varied ecoregions, physiography, and land management conditions. The framework is computationally efficient, enabling national‐scale ensemble forecasts in minutes.

artificial intelligence↗

Time Matters: A Survival Analysis of Public Electric Vehicle Charging Infrastructure Utilization

The rapid adoption of plug-in electric vehicles (PEVs) places significant demands on public charging infrastructure, making it critical to understand and optimize charger utilization. This study provides one of the most comprehensive analyses of charging behavior to date by applying a survival analysis to a dataset of nearly 16 million level 2 (L2) and direct current (DC) fast charger sessions across the United States from 2017 to 2022. Using Kaplan-Meier curves and log rank tests, our analysis reveals statistically significant and distinct duration patterns influenced by charger type, time of day, and day of the week. We find that L2 charging sessions exhibit high variability tied to venue type, whereas DC sessions are more uniform, typically lasting 30-45 min. This study introduces the operational efficiency score (OES), a metric for standardizing the performance evaluation of charging stations. Our findings offer actionable insights for optimizing charger deployment, developing dynamic pricing strategies to reduce vehicle dwell time, and improving load management for grid operators, ultimately enhancing the efficiency and availability of public charging infrastructure.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

EnergyPlus-MCP: A model-context-protocol server for ai-driven building energy modeling

Traditional building energy modeling with the EnergyPlus building performance simulation engine requires domain expertise, programming skills, and intensive manual efforts limiting its effective adoption. This paper introduces EnergyPlus-MCP, the first open-source Model Context Protocol (MCP) server specifically designed for EnergyPlus simulation workflows, establishing a new foundational infrastructure for AI-driven building energy modeling. The MCP server implements a layered architecture with 35 specialized tools spanning model management, editing and analysis, HVAC and other systems configuration inspection, and simulation execution, enabling Large Language Models to interact with EnergyPlus through conversational interfaces. The server addresses critical workflow barriers by automating model validation, streamlining energy efficiency measures modification, and providing intelligent output management with interactive visualization. Through practical demonstrations using a multi-zone building retrofit analysis, we show how the EnergyPlus-MCP server significantly reduces manual efforts while maintaining full simulation rigor. By providing accessible natural language interfaces to sophisticated building energy analysis, this approach enables scalable deployment of simulation expertise across public and private organizations, educational institutions, and research teams, fundamentally transforming traditional building energy modeling practices.

AI↗

Li-Ion Battery Thermal Characterization for Thermal Management Design

Battery design efforts often prioritize enhancing the energy density of the active materials and their utilization. However, optimizing thermal management systems at both the cell and pack levels is also key to achieving mission-relevant battery design. Battery thermal management systems, responsible for managing the thermal profile of battery cells, are crucial for balancing the trade-offs between battery performance and lifetime. Designing such systems requires accounting for the multitude of heat sources within battery cells and packs. This paper provides a summary of heat generation characterizations observed in several commercial Li-ion battery cells using isothermal battery calorimetry. The primary focus is on assessing the impact of temperatures, C-rates, and formation cycles. Moreover, a module-level characterization demonstrated the significant additional heat generated by module interconnects. Characterizing heat signatures at each level helps inform manufacturing at the design, production, and characterization phases that might otherwise go unaccounted for at the full pack level. Further testing of a 5 kWh battery pack revealed that a considerable temperature non-uniformity may arise due to inefficient cooling arrangements. To mitigate this type of challenge, a combined thermal characterization and multi-domain modeling approach is proposed, offering a solution without the need for constructing a costly module prototype.

25 ENERGY STORAGE↗

Holistic energy analysis method for thermal management architectures of data centers

Modern high-performance computing (HPC) data centers (DCs), particularly those supporting energy-intensive artificial intelligence (AI) workloads, face escalating thermal management challenges that degrade performance through thermal throttling and drive up cooling power consumption and operational costs. To address this challenge, many have developed a wide variety of thermal management solutions (single-phase, two-phase, direct, indirect, hybrid, and more) which attempt to cool HPC DCs effectively while attempting to minimize overall system power consumption. However, the analysis of these solutions and methods to effectively compare one with another is lacking. Overall power usage effectiveness (PUE) and total-power usage effectiveness (TUE) provide a metric to quantify power consumption but fail to identify components in the system which require further optimization. To address this, we propose a holistic analytical framework – the waterfall diagram (WFD) – which leverages a waterfall chart methodology, offering a comprehensive visualization of both the thermal management system loop and heat flow pathways from individual server components to the outdoor ambient. Use of the WFD enables graphical estimations of power efficiency and cooling performance across each component of a DC cooling system and complements Sankey-style energy flow visualizations by additionally resolving stage-wise temperature changes and incremental TUE contributions. The framework is used in conjunction with simulation-based approaches, to conduct a detailed pressure drop and flow distribution analysis aimed at identifying the optimal coolant distribution architecture for a single-phase direct-to-chip water-cooled DC, which serves as the baseline for subsequent WFD analysis. Among the evaluated architectures, the 3 U modular coolant distribution architecture is found to demonstrate the best performance, considering minimal pressure drop and uniform flow distribution. In addition, TUE is calculated for each cooling loop component based on its associated pressure drop and corresponding pumping power, which are integrated into the WFD. This correlation between TUE and local temperature offers immediate insight into the power efficiency and thermal performance contributions of individual components, facilitating further development and optimization. Examples of WFD applications are presented under varying thermal loads and ambient conditions, demonstrating reasonable cooling strategies. Notably, the 3 U modular architecture maintains a consistent chip case temperature of 85°C, achieving a TUE of 1.016 at ambient temperature of 47°C, and a TUE of 1.026 at ambient temperature of 52°C. The WFD methodology provides an efficient, holistic, and streamlined framework for DC thermal management architecture assessment and enables design optimization which is important for addressing the thermal-fluidic energy challenges of current and next-generation DCs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reaction Optimization for Enzymatic Deconstruction of Industrially Relevant Nylon Composites

Plastics such as polyamides (PAs) possess unique physicochemical properties that make them indispensable in modern society. However, their energy‐intensive production and challenging end‐of‐life management highlight the urgent need for efficient recycling or remanufacturing solutions. Enzymatic depolymerization offers a promising route toward circular recycling, yet remains constrained by limited enzyme characterization, lack of validation under industrially relevant conditions and substrates, and overall performance. Here, we optimized the reaction conditions for three recently discovered nylon‐degrading enzymes. One of them, Nyl12, achieved product titers with PA6 and PA66 that exceed previously reported values, without enzyme engineering or substrate pretreatment. We further demonstrated the scalability of the process and its application to complex PA‐based materials used in microelectronic components. Analysis of substrate features, including surface area and particle size, revealed key parameters governing enzymatic activity and provided a framework for future pretreatment and process optimization efforts. In combination, these efforts provide a new benchmark for enzymatic nylon recycling.

nylon↗

Utilization of Ultrasonication as a Method of Reducing Organic and Inorganic Contamination in Post‐Consumer Plastic Film Waste

Post-consumer plastic film waste often carries organic and inorganic contaminants that challenge recycling processes and affect the quality of recycled products. An effective contaminant removal procedure through washing such single-used plastic films (SUPFs) can address environmental and waste management concerns. This study compares the efficiency of different washing techniques in reducing SUPF contamination. To evaluate the efficacy of each washing technique, film samples collected from material recovery facilities are individually exposed to friction, ultrasonic-assisted, and a combination of both washes. Thermal analysis indicates that the polymers' melting temperature, crystallization temperature, and crystallinity remain unaffected by the washing methods, demonstrating method aptness. Confocal laser scanning microscope images show that washing results in a cleaner sample surface. 91% ash reduction during the combined wash treatment indicates a high method efficiency compared to the individual friction and ultrasonic wash procedures. This is further validated by reducing characteristic contaminant IR bands (3600–3000, 1750–1600, and 1100–1000 cm −1 ). Elements of concern such as Cd, Cr, Hg, and Pb in SUPFs after each washing technique applied conform with regulations (<100 ppm) for packaging products. This research shows the novel ultrasonic washing reduces more contamination than friction with shorter wash times and no surfactants.

42 ENGINEERING↗

Advances in supervisory control strategies for a heat pump centric HVAC system − a comprehensive review on applications

There is an increase in research investigating the development and deployment of supervisory controllers that enable high efficiency electrically driven vapor compression heat pumps operating within grid interactive efficient buildings to provide demand side management. This paper reviews over sixty relevant case studies within this domain that focus on commercial off-the-shelf heat pumps whose primary task is providing space conditioning. The concept of a heat pump-centric heating, ventilation, and air-conditioning system is introduced, accompanied by a detailed overview of various kinds of electric heat pumps and building-level thermal energy storage configurations. Additionally, the different types of supervisory controller designs, including rule-based control and model predictive control, are discussed, along with the various methods for communication between a supervisory controller and a downstream heat pump’s local controller. A comparative analysis is conducted in order to categorize the reviewed case studies based on their system design, supervisory control algorithm, and validation methodology. This detailed analysis allows the review to establish current research trends, identify potential gaps, and suggest future directions for the development of this technology. Overall, the authors recommend that more future research be devoted to low-cost practical retrofits that allow for easy integration of active thermal energy storage within heat pump-centric heating, ventilation, and air-conditioning system systems that utilize direct expansion heat pumps. We also suggest more research into the development and deployment of supervisory controllers that can properly communicate with commercial off-the-shelf heat pump local controller available control inputs, e.g., zone temperature setpoint. Lastly, more rigorous experimental demonstrations of advanced supervisory control within real and or closed-loop, transient/ quasi-steady state environments are necessary to reduce industry wide skepticism of this technology.

Demand side management↗

Advanced blade-shaped thermal energy storage device: Development and application

Thermal energy storage (TES) using phase change materials (PCMs) is a promising approach for capturing and reusing excess thermal energy, yet widespread adoption is limited by low thermal conductivity, bulky configurations, and inadequate scalability. Here, this study presents a modular, blade-shaped TES prototype designed to address these challenges. The device integrates a lightweight aluminum shell, an embedded serpentine coil for active or passive heat exchange, and a cost-effective corrugated metal mesh for enhanced PCM thermal conductivity. With thickness-to-length and thickness-to-width ratios of 0.03 and 0.08, respectively, the blade-shaped TES achieves a compact, modular form factor suitable for space-constrained applications. Experimental testing demonstrated the efficient charge and discharge behavior of blade-shaped TES, capturing PCM superheating, phase-change transitions, and subcooling dynamics, with charging and discharging efficiencies of 94.9% and 94.6%, respectively. Also, the system can potentially achieve higher energy density than that of conventional TES designs. When integrated into a household refrigerator during the study, three blade-shaped TES modules successfully shifted 100% of peak-time compressor operation to off-peak hours, reducing energy consumption while maintaining more stable compartment temperatures. The blade-shaped TES's thin geometry, modularity, and enhanced thermal performance support scalable deployment across residential, commercial, and industrial applications, providing a versatile, cost-effective solution for high-efficiency, demand-flexible thermal energy management.

Blade-shaped↗

Framework of compressive sensing and data compression for 4D-STEM

Four-dimensional Scanning Transmission Electron Microscopy (4D-STEM) is a powerful technique for high-resolution and high-precision materials characterization at multiple length scales, including the characterization of beam-sensitive materials. However, the field of view of 4D-STEM is relatively small, which in absence of live processing is limited by the data size required for storage. Furthermore, the rectilinear scan approach currently employed in 4D-STEM places a resolution- and signal-dependent dose limit for the study of beam sensitive materials. Improving 4D-STEM data and dose efficiency, by keeping the data size manageable while limiting the amount of electron dose, is thus critical for broader applications. Here we introduce a general method for reconstructing 4D-STEM data with subsampling in both real and reciprocal spaces at high fidelity. The approach is first tested on the subsampled datasets created from a full 4D-STEM dataset, and then demonstrated experimentally using random scan in real-space. The same reconstruction algorithm can also be used for compression of 4D-STEM datasets, leading to a large reduction (100 times or more) in data size, while retaining the fine features of 4D-STEM imaging, for crystalline samples.

4D-STEM↗

OpenFacadeControl: enabling integration of automated facades with other building systems

Automated facades are, for the most part, still considered as separate from other building systems throughout the design, installation, commissioning, operation, and maintenance cycle. This takes place despite the fact that their energy and comfort performance are deeply interlinked with the operation of lighting and HVAC systems. Over the last two decades, research has shown that there are significant advantages from operating facades as an integrated system with the rest of the building. Nevertheless, significant barriers prevent this type of integration becoming more common. One of them is the lack of a platform that is inexpensive to implement and that easily allows the practical implementation of integrated control algorithms across fenestration and other building systems, using a variety of communications protocols. This is particularly challenging when automated facades are installed in existing buildings, where interaction with legacy building systems that were installed over the past lifetime of the building can require a high degree of interoperability. OpenFacadeControl (OFC) is an open-source controls framework aimed at unified control of facades and other building systems, including the sharing of third-party sensor information. Through leveraging the Volttron controls platform, it allows the integration of systems and sensors that are manufactured by different companies and that use different communications protocols into an ensemble that functions as a single system. OFC is designed to enable integrated control algorithms of varying degrees of complexity, ranging from simple, heuristic controls to more sophisticated approaches like model-predictive control. Use of a research version to test advanced lighting and shading strategies in a full-scale experimental testbed has demonstrated the ease of deploying advanced control solutions using OpenFacadeControl. This paper presents the structure of OpenFacadeControl and a demonstration case showing the use of OFC in laboratory tests of advanced lighting and fenestration controls that coordinated motorized shades communicating via the BACnet building communications standard and lights communicating via internet-protocol-based application programming interface (API), based on the readings of a shared light level sensor communicating via a different API.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Makah Tribe Strategic Energy Plan

The U.S. Department of Energy’s (DOE) Energy Transitions Initiative Partnership Project (ETIPP) connects remote and island communities, regional partners, and the DOE national laboratories to support communities as they seek to build resilience in their energy systems. The Makah Tribe faces several energy challenges, including frequent power outages and the potential for an extended outage due to an earthquake or tsunami. The Tribe joined ETIPP in 2022 to address those challenges, seeking to build energy resilience and sovereignty in the community. The Makah Tribe, Spark Northwest, the Pacific Northwest National Laboratory (PNNL), and the National Renewable Energy Laboratory (NREL) collaborated to develop a strategic energy plan as part of the second cohort of ETIPP communities. The long-term energy vision of the Makah Tribe includes increasing energy efficiency in the community, improving energy management capacity, and developing the renewable energy generation and storage sufficient to independently power the Reservation for one year. Additionally, the ETIPP team worked with Makah leadership, staff, and community members to identify a set of community priorities, values, and goals to guide energy development as the Tribe takes the incremental steps toward their vision for energy sovereignty. Those energy values include ecosystem-based management, energy sovereignty and project ownership, workforce development and capacity, economic opportunity, community wellbeing and priorities, and emergency disaster resilience. To understand what would be needed for a year for energy independence, the PNNL team conducted an assessment to determine the current energy usage of the Tribe and also modeled several scenarios for future energy use. Using the energy usage values, the team estimated how two types of renewable energy technology, specifically locally deployed solar and small-scale wind, could contribute towards the energy independence goal. The energy baseline and resource assessment produced the following key findings:

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Unlocking Energy Efficiency: Debunking Myths on the Road to Decarbonization

Energy efficiency is widely recognized as the foundational and most critical strategy for decarbonizing the manufacturing sector. Misconceptions surrounding energy efficiency measures often hinder their widespread adoption. This article aims to debunk five common myths and provides data and resources to help implement efficiency projects faster and more effectively to achieve greater decarbonization. First, the article challenges the myth that organizations have exhausted all possible energy efficiency opportunities by achieving voluntary energy intensity goals or energy performance certification. Second, it also addresses the misconceptions that efficiency projects are capital-intensive, require many qualified specialists, and have long investment return periods. By presenting real-world case studies and referencing commonly found efficiency opportunities, the article illustrates that energy-savings opportunities are ubiquitous. Organizations can use various contracting mechanisms as well as financial and technical resources from utility companies and government programs to lessen their burden. The notion that efficiency measures can be implemented solely in proprietorship facilities is dispelled. This article emphasizes the importance of green leases and explains that aligning decarbonization goals between the lessor and lessee can help drive savings for both parties. Finally, using unbundled renewable energy certificates as the sole pathway to decarbonization is strongly discouraged. By debunking these prevalent myths, this article aims to foster a deeper understanding of energy efficiency’s potential as a cornerstone of decarbonization efforts and to embrace it as a critical pathway toward a sustainable future.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗