Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mars Science (MSL) Laboratory”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Aqueous Alteration of Smectite in Acid-Sulfate Fluids: Implications for Clay Mineralogy at Gale Crater

The Chemistry and Mineralogy (CheMin) instrument on the Mars Science Laboratory (MSL) Rover, Curiosity, analyzes samples collected in Gale Crater, Mars using X-ray diffraction (XRD). One site of interest is the Oudam drill sample that CheMin analyzed on sols 1362, 1365, and 1369, which contains ~3 wt% phyllosilicate. XRD analysis of this phyllosilicate suggests a 2:1 Fe3+-smectite, akin to nontronite.

Rudolph, A. N.↗

MEDLI2: Ablator Models for Flight

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating[1,2]. Discrepancies between MEDLI’s flight heating data and predicted thermal response and recession[3] led to a campaign to characterize and test Mars2020 and MEDLI2 (Mars Entry, Descent, and Landing Instrument 2)[4] flight-lot thermal protection materials (TPS) at relevant ground test conditions. This paper covers the development and validation of flight-lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material SLA-561V (Super Lightweight Ablator). Virgin and char properties such as thermal conductivity and emissivity were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties were characterized and determined to be similar to prior TPS material measurements used for the heritage models. MEDLI2 also investigated the impact of the protective coating that was applied to MSL and Mars2020’s PICA heatshield to reduce the particulate matter shedding. Evidence from arc jet experiments on coated PICA showed that although there were no adverse effects on the performance of the TPS, there were differences in the in-depth temperatures and reduced recession compared to material response predictions of uncoated PICA.[5,6]. Fully Implicit Ablation and Thermal response (FIAT)[7] material response simulations were conducted with the heritage and MEDLI2 flight-lot material models. FIAT-predicted in-depth temperature responses and recession predictions were compared to flight-lot certification ground-test arc jet test data and MEDLI2 thermocouple data.

Materials Response↗

MEDLI2 Material Response Model Development and Validation

During the entry of Mars Science Laboratory (MSL) the heatshield was equipped with the instrumentation suite Mars Entry, Descent, and Landing Instruments (MEDLI). In-depth thermocouple (TC) data was used to reconstruct the surface heating and temperatures. Discrepancies between MEDLI’s recorded in-depth heating data and the predicted thermal response and recession led to a campaign to characterize and test Mars Entry, Descent, and Landing Instrument 2 (MEDLI2) flight lot thermal protection materials (TPS) at relevant temperatures and pressures for Martian entry conditions. This paper covers the development and validation of MEDLI2 flight lot material response models for the heatshield material Phenolic Impregnated Carbon Ablator (PICA) and the backshell material Super-Lightweight Ablator (SLA-561V). Virgin and char thermal conductivities were updated as a function of temperature and pressure in the MEDLI2 specific material response models. Other material properties such as virgin and char density, emissivity, absorptivity, and specific heat capacitance was also characterized and compared to the “Heritage” models used during the TPS design phase of Mars 2020. Fully Implicit Ablation and Thermal response (FIAT) simulations were completed using the Heritage and MEDLI2 material response models to provide evidence of the increased accuracy of the MEDLI2 model. FIAT predicted in-depth temperatures were compared to flight lot certification ground-test arc jet test data and MEDLI2 flight thermocouple data.

Material response↗

MSL Chemistry and Mineralogy X-Ray Diffraction X-Ray Fluorescence (CheMin) Instrument

This paper provides an overview of the Mars Science Laboratory (MSL) Chemistry and Mineralogy Xray Diffraction (XRD), X-ray Fluorescence (XRF) (CheMin) Instrument, an element of the landed Curiosity rover payload, which landed on Mars in August of 2012. The scientific goal of the MSL mission is to explore and quantitatively assess regions in Gale Crater as a potential habitat for life - past or present. The CheMin instrument will receive Martian rock and soil samples from the MSL Sample Acquisition/Sample Processing and Handling (SA/SPaH) system, and process it utilizing X-Ray spectroscopy methods to determine mineral composition. The Chemin instrument will analyze Martian soil and rocks to enable scientists to investigate geophysical processes occurring on Mars. The CheMin science objectives and proposed surface operations are described along with the CheMin hardware with an emphasis on the system engineering challenges associated with developing such a complex instrument.

sample chemistry↗

Thermal Operability Improvements for the Mars 2020 Rover Surface Mission

The Mars 2020 Rover is scheduled to land on Mars on February 18, 2021. One of the primary mission objectives for the Mars 2020 Rover is to perform in-situ science and collect a set of Martian regolith samples for possible future return to Earth. In order to meet mission requirements, 20 samples must be collected, assessed, and sealed during the prime mission (1.5 Martian years, approximately 1000 Sols). This requires that the Mars 2020 Rover operate in a much more efficient and autonomous manner than its predecessor, the Mars Science Laboratory (MSL) Rover, Curiosity. The thermal designs of both Curiosity and the Mars 2020 Rover utilize warmup heaters to bring the actuators and cameras, located on the outside of the vehicle, up to their operating temperatures prior to use. These heaters consume energy during the mission. The Rover energy balance, between energy production and consumption, must be maintained in order to keep the mission moving safely forward. Increased efficiency in the way this warmup heater energy is allocated and used in the Mars 2020 Rover operations plan will result in more energy available for science and engineering activities. This paper discusses the improvements that were made in both hardware and software to improve the way the Mars 2020 Rover will operate thermally on Mars.

Lee, Chern-Jiin↗

Mars Science Laboratory Rover Mobility Bushing Development

NASA s Mars Science Laboratory (MSL) Project will send a six-wheeled rover to Mars in 2009. The rover will carry a scientific payload designed to search for organic molecules on the Martian surface during its primary mission. This paper describes the development and testing of a bonded film lubricated bushing system to be used in the mobility system of the rover. The MSL Rover Mobility System contains several pivots that are tightly constrained with respect to mass and volume. These pivots are also exposed to relatively low temperatures (-135 C) during operation. The combination of these constraints led the mobility team to consider the use of solid film lubricated metallic bushings and dry running polymeric bushings in several flight pivot applications. A test program was developed to mitigate the risk associated with using these materials in critical pivots on the MSL vehicle. The program was designed to characterize bushing friction and wear performance over the expected operational temperature range (-135 C to +70 C). Seven different bushing material / lubricant combinations were evaluated to aid in the selection of the final flight pivot bushing material / lubricant combination.

Riggs, Benjamin↗

Exploration of the Habitability of Mars with the SAM Suite Investigation on the 2009 Mars Science Laboratory

The 2009 Mars Science Laboratory (MSL) with a substantially larger payload capability that any other Mars rover, to date, is designed to quantitatively assess a local region on Mars as a potential habitat for present or past life. Its goals are (1) to assess past or present biological potential of a target environment, (2) to characterize geology and geochemistry at the MSL landing site, and (3) to investigate planetary processes that influence habitability. The Sample Analysis at Mars (SAM) Suite, in its final stages of integration and test, enables a sensitive search for organic molecules and chemical and isotopic analysis of martian volatiles. MSL contact and remote surface and subsurface survey Instruments establish context for these measurements and facilitate sample identification and selection. The SAM instruments are a gas chromatograph (GC), a mass spectrometer (MS), and a tunable laser spectrometer (TLS). These together with supporting sample manipulation and gas processing devices are designed to analyze either the atmospheric composition or gases extracted from solid phase samples such as rocks and fines. For example, one of the core SAM experiment sequences heats a small powdered sample of a Mars rock or soil from ambient to -1300 K in a controlled manner while continuously monitoring evolved gases. This is followed by GCMS analysis of released organics. The general chemical survey is complemented by a specific search for molecular classes that may be relevant to life including atmospheric methane and its carbon isotope with the TLS and biomarkers with the GCMS.

Mahaffy, P. R.↗

Utilizing Mars Global Reference Atmospheric Model (Mars-GRAM 2005) to Evaluate Entry Probe Mission Sites

The Mars Global Reference Atmospheric Model (Mars-GRAM 2005) is an engineering-level atmospheric model widely used for diverse mission applications. An overview is presented of Mars-GRAM 2005 and its new features. The "auxiliary profile" option is one new feature of Mars-GRAM 2005. This option uses an input file of temperature and density versus altitude to replace the mean atmospheric values from Mars-GRAM's conventional (General Circulation Model) climatology. Any source of data or alternate model output can be used to generate an auxiliary profile. Auxiliary profiles for this study were produced from mesoscale model output (Southwest Research Institute's Mars Regional Atmospheric Modeling System (MRAMS) model and Oregon State University's Mars mesoscale model (MMM5) model) and a global Thermal Emission Spectrometer (TES) database. The global TES database has been specifically generated for purposes of making Mars-GRAM auxiliary profiles. This data base contains averages and standard deviations of temperature, density, and thermal wind components, averaged over 5-by-5 degree latitude-longitude bins and 15 degree Ls bins, for each of three Mars years of TES nadir data. The Mars Science Laboratory (MSL) sites are used as a sample of how Mars-GRAM' could be a valuable tool for planning of future Mars entry probe missions. Results are presented using auxiliary profiles produced from the mesoscale model output and TES observed data for candidate MSL landing sites. Input parameters rpscale (for density perturbations) and rwscale (for wind perturbations) can be used to "recalibrate" Mars-GRAM perturbation magnitudes to better replicate observed or mesoscale model variability.

Justh, Hilary L.↗

Orion Exploration Flight Test-1 Contingency Drogue Deploy Velocity Trigger

As a backup to the GPS-aided Kalman filter and the Barometric altimeter, an "adjusted" velocity trigger is used during entry to trigger the chain of events that leads to drogue chute deploy for the Orion Multi-Purpose Crew Vehicle (MPCV) Exploration Flight Test-1 (EFT-1). Even though this scenario is multiple failures deep, the Orion Guidance, Navigation, and Control (GN&C) software makes use of a clever technique that was taken from the Mars Science Laboratory (MSL) program, which recently successfully landing the Curiosity rover on Mars. MSL used this technique to jettison the heat shield at the proper time during descent. Originally, Orion use the un-adjusted navigated velocity, but the removal of the Star Tracker to save costs for EFT-1, increased attitude errors which increased inertial propagation errors to the point where the un-adjusted velocity caused altitude dispersions at drogue deploy to be too large. Thus, to reduce dispersions, the velocity vector is projected onto a "reference" vector that represents the nominal "truth" vector at the desired point in the trajectory. Because the navigation errors are largely perpendicular to the truth vector, this projection significantly reduces dispersions in the velocity magnitude. This paper will detail the evolution of this trigger method for the Orion project and cover the various methods tested to determine the reference "truth" vector; and at what point in the trajectory it should be computed.

Gay, Robert S.↗

A Kinematic Calibration Process for Flight Robotic Arms

The Mars Science Laboratory (MSL) robotic arm is ten times more massive than any Mars robotic arm before it, yet with similar accuracy and repeatability positioning requirements. In order to assess and validate these requirements, a higher-fidelity model and calibration processes were needed. Kinematic calibration of robotic arms is a common and necessary process to ensure good positioning performance. Most methodologies assume a rigid arm, high-accuracy data collection, and some kind of optimization of kinematic parameters. A new detailed kinematic and deflection model of the MSL robotic arm was formulated in the design phase and used to update the initial positioning and orientation accuracy and repeatability requirements. This model included a higher-fidelity link stiffness matrix representation, as well as a link level thermal expansion model. In addition, it included an actuator backlash model. Analytical results highlighted the sensitivity of the arm accuracy to its joint initialization methodology. Because of this, a new technique for initializing the arm joint encoders through hardstop calibration was developed. This involved selecting arm configurations to use in Earth-based hardstop calibration that had corresponding configurations on Mars with the same joint torque to ensure repeatability in the different gravity environment. The process used to collect calibration data for the arm included the use of multiple weight stand-in turrets with enough metrology targets to reconstruct the full six-degree-of-freedom location of the rover and tool frames. The follow-on data processing of the metrology data utilized a standard differential formulation and linear parameter optimization technique.

Collins, Curtis L.↗

Mars Science Laboratory Heatshield Flight Data Analysis

NASA Mars Science Laboratory (MSL), which landed the Curiosity rover on the surface of Mars on August 5th, 2012, was the largest and heaviest Mars entry vehicle representing a significant advancement in planetary entry, descent and landing capability. Hypersonic flight performance data was collected using MSLs on-board sensors called Mars Entry, Descent and Landing Instrumentation (MEDLI). This talk will give an overview of MSL entry and a description of MEDLI sensors. Observations from flight data will be examined followed by a discussion of analysis efforts to reconstruct surface heating from heatshields in-depth temperature measurements. Finally, a brief overview of MEDLI2 instrumentation, which will fly on NASAs Mars2020 mission, will be presented with a discussion on how lessons learned from MEDLI data affected the design of MEDLI2 instrumentation.

Mars↗

Unraveling the Aqueous Alteration History and Searching for Extinct Life in Gale Crater, Mars: Mineralogical and Geochemical Results from the Mars Science Laboratory, Curiosity Rover's Instrument Payload

The goal of the Mars Science Laboratory (MSL), Curiosity Rover mission is to determine if Gale Crater, Mars ever had a habitable environment and to search for evidence of extinct microbial life. Gale Crater is ~155 km wide with a layered central mound (~5 km high). The Curiosity rover has traversed ~20 km from the crater floor up 350 m to the lower slopes of the central mound for over 2200 Martian solar days (sols). Curiosity's instruments have evaluated the geochemistry and mineralogy of regolith fines, eolian sediments, and sedimentary rocks to assess Gale Crater's aqueous alteration history. Results indicate that Gale Crater surface material have experienced a complex authigenetic/diagenetic history involving fluids with varying pH, redox, and salt composition. The inferred geochemical conditions were favorable for microbial habitability and if life ever existed, there was likely sufficient organic C to support a small microbial population.

Sutter, Brad↗

In Situ Analysis of Martian Regolith with the SAM Experiment During the First Mars Year of the MSL Mission: Identification of Organic Molecules by Gas Chromatography from Laboratory Measurements

The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.

analysis↗

Analysis of Mixed Aryl/Alkyl Esters by Pyrolysis Gas Chromatography-Mass Spectrometry in the Presence of Perchlorate

Mars is an important target for Astrobiology. A key goal of the MSL mission was to determine whether Mars was habitable in the past, a que-tion that has now been definitely determined to be yes. Another key goal for Mars exploration is to understand the origin and distribution of organic material on Mars; this question is being addressed by the SAM instrument on MSL, and will also be informed by two upcoming Mars exploration missions, ExoMars and Mars 2020. These latter two missions have instrumentation capable of detecting and characterize organic molecules. Over the next decade, these missions will analyze organics in surface, near-surface and sub-surface samples. Each mission has the capability to analyze organics by different methods (pyrolysis gas chromatography-mass spectrometry [py-GC-MS]; laser desorption and thermal volatilization GC-MS; and Raman spectroscopy). Plausibly extraterrestrial organics were recently discovered by the Mars Science Laboratory (MSL), providing an important first step towards understanding the organic inventory on Mars [1]. The compounds detected were chlorobenzenes and chloroalkanes, but it was argued that chlorination of these compounds occurred during pyrolysis of samples containing unchlorinated organics in the presence of perchlorate. A recent report analyzed a suite of aromatic (benzene, toluene, benzoic acid, phthalic acid, and mellitic acid) and aliphatic (acetic acid, propane, propanol, and hexane) by pyrolysis under SAM-like conditions in the presence of perchlorate to attempt to constrain possible precursor molecules for the organic molecules detected on Mars. For aromatic compounds, the aromatic acids all readily produced SAM-relevant chlorobenzes, whereas benzene and toluene did not. This observation suggests that the chlorobenzene detected on Mars could have derived from compounds like mellitic acid, consistent with the previous hypothesis by Benner et al. [3]. Among the aliphatic molecules, it was shown that pyrolysis of alkanes and alcohols in the presence of perchlorates produced polychlorine containing chloro-alkanes similar to what was observed on Mars. Surpris-ingly, however, similar treatment of acetic acid pro-duced chloroketones, instead, and no chloroalkanes were reported. This suggests that the chloroalkanes detected in the Sheepbed mudstone were not derived from aliphatic carboxylic acids, but instead were from more reduced alcohols or even alkanes, or perhaps were degradation products of more complicated organic material. Because organics analyses on mars will rely heavily on py-GC-MS of perchlorate-containing samples over the next decade, it is important to understand the fate of organic molecules of biotic and abiotic origin under such conditions. In this work we begin a series of experiments to improve our understanding of products generated during py-GC-MS of increasingly complex organic molecules (esters, amides, peptides, nucleic acids, fatty acids) in the presence of perchlorate.

Burton, A. S.↗

In situ Analysis of Organic Compounds on Mars using Chemical Derivatization and Gas Chromatography Mass Spectrometry

One of the core science objectives of NASA's 2009 Mars Science Laboratory (MSL) mission is to determine the past or present habitability of Mars. The search for key organic compounds relevant to terrestrial life will be an important part of that assessment. We have developed a protocol for the analysis of amino acids and carboxylic acids in Mars analogue materials using gas chromatography mass spectrometry (GCMS). As shown, a variety of carboxylic acids were readily identified in soil collected from the Atacama Desert in Chile at part-per-billion levels by GCMS after extraction and chemical derivatization using the reagent N,N-tert.-butyl (dimethylsilyl) trifluoroacetamide (MTBSTFA). Several derivatized amino acids including glycine and alanine were also detected by GCMS in the Atacama soil at lower concentrations (chromatogram not shown). Lacking derivatization capability, the Viking pyrolysis GCMS instruments could not have detected amino acids and carboxylic acids, since these non-volatile compounds require chemical transformation into volatile species that are stable in a GC column. We are currently optimizing the chemical extraction and derivatization technique for in situ GCMS analysis on Mars. Laboratory results of analyses of Atacama Desert samples and other Mars analogue materials using this protocol will be presented.

Glavin, D. P.↗

Microbial Habitability in Gale Crater: Sample Analysis at Mars (SAM) Instrument Detection of Microbial Essential Carbon and Nitrogen

Chemical analyses of Mars soils and sediments from previous landed missions have demonstrated that Mars surface materials possessed major (e.g., P, K, Ca, Mg, S) and minor (e.g., Fe, Mn, Zn, Ni, Cl) elements essential to support microbial life. However, the detection of microbial essential organic-carbon (C) and nitrate have been more elusive until the Mars Science Laboratory (MSL) rover mission. Nitrate and organic-C in Gale Crater, Mars have been detected by the Sample Analysis at Mars (SAM) instrument onboard the MSL Curiosity rover. Eolian fines and drilled sedimentary rock samples were heated in the SAM oven from approximately 30 to 860 degrees Centigrade where evolved gases (e.g., nitrous oxide (NO) and CO2) were released and analyzed by SAM’s quadrupole mass spectrometer (MS). The temperatures of evolved NO was assigned to nitrate while evolved CO2 was assigned to organic-C and carbonate. The CO2 releases in several samples occurred below 450 degrees Centigrade suggesting organic-C dominated in those samples. As much as 7 micromoles NO3-N per gram and 200 micromoles CO2-C per gram have been detected in the Gale Crater materials. These N and C levels coupled with assumed microbial biomass (9 x 10 (sup -7) micrograms per cell) C (0.5 micrograms C per micrograms cell) and N (0.14 micrograms N per micrograms cell) requirements, suggests that less than 1 percent and less than 10 percent of Gale Crater C and N, respectively, would be required if available, to accommodate biomass requirements of 1 by 10 (sup 5) cells per gram sediment. While nitrogen is the limiting nutrient, the potential exists that sufficient N and organic-C were present to support limited heterotrophic microbial populations that may have existed on ancient Mars.

Sutter, B.↗

The Role of Diagenesis at Vera Rubin Ridge in Gale Crater, Mars, and the Chemostratigraphy of the Murray Formation as Observed by the Chemcam Instrument

The Mars Science Laboratory (MSL) Curiosity rover explored Vera Rubin ridge (VRR) in Gale crater, Mars, for almost 500 sols (Mars days) between arriving at the ridge on sol 1809 of the mission in September 2017 and leaving it on sol 2302 upon entering the Glen Torridon area south of the ridge. VRR is a topographic ridge on the central mound, Aeolis Mons (Mt. Sharp), in Gale crater that displays a strong hematite spectral signature from orbit. In-situ observations on the ridge led to the recognition that the ridge-forming rocks belong to the Murray formation, the lowermost exposed stratigraphic unit of the Mt. Sharp group, that was first encountered at the Pahrump Hills location. Including VRR rocks, the Murray formation, interpreted to be primarily deposited in an ancient lacustrine environment in Gale crater, is more than 300 m thick. VRR itself is composed of two stratigraphic members within the Murray formation, the Pettegrove Point member overlain by the Jura member. The Pettegrove Point member overlies the Blunts Point member of the Murray formation. Areas of gray coloration are observed in the Jura member predominantly, but also in the Pettegrove Point member. Generally, gray areas are found in local topographic depressions, but contacts between red and gray rocks crosscut stratigraphy. Additionally, cm-scale dark concretions with very high iron-content are commonly observed in gray rocks, typically surrounded by a lighttoned zone that is conversely depleted in iron. A key goal for the VRR campaign was to characterize geochemical variations in the ridge-forming rocks to investigate the role of primary and diagenetic controls on the geochemistry and morphology of VRR. Here, we present observations by the ChemCam instrument on VRR and compare these to the full Murray formation chemostratigraphy. This work was recently submitted to a special issue of JGRPlanets that detail the full VRR campaign.

Frydenvang, J.↗

MSL Entry, Descent, and Landing Instrumentation: Return on Investment

On Aug 5, 2012 the Mars Science Laboratory (MSL) Entry, Descent, and Landing Instrumentation (MEDLI) suite on MSL entry vehicle heatshield suc-cessfully returned surface pressure and in-depth temperature data.1,2 The MEDLI data has given scientists and engineers an unprecedented ability to reconstruct entry environment, atmospheric density, and flight trajectory, and flight validation of predic-tions vehicle aerodynamics and thermal protection system (TPS) performance. This presentation will dis-cuss key findings from MEDLI, some of which are being applied to improve definition of aerothermal environment and TPS sizing margins for existing NASA entry missions. The postflight analysis has shown that a significant thermal protection mass saving upon redesign is possible for an MSL-class vehicle. The success of MEDLI has also demonstrated and qualified robust flight instrumentation technologies at very low risk to the mission. The potential benefits of MEDLI to planetary exploration and sample return missions, as well as to exploration class missions to Mars will be presented.

MEDLI↗