Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mask”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Multi-Star Wavefront Control at the Occulting Mask Coronagraph Testbed: Monochromatic Laboratory Demonstration for the Roman Coronagraph Instrument

The Astro2020 decadal survey recommended the Habitable Worlds Observatory (HWO), NASA’s direct imaging flagship mission, with a goal to achieve a statistically robust mission yield of 25 or more potentially habitable exoplanets. One way to achieve is to increase the instrument effectiveness by introducing additional bright, nearby targets. A majority of Sun-like stars have a stellar companion that can introduce additional noise into the field of view of any high-contrast imaging instrument and enabling exoplanet discovery around binary stars represents a path to increased corona graphic instrument efficiency by increasing the available science target pool of bright nearby stars. This includes both of the Alpha Centauri A and B stars which would represent the top science target for direct imaging if companion leakage could be suppressed. Multi-Star Wavefront Control(MSWC) is a technique that removes stellar leakage from both stellar components, enabling direct imaging of exoplanets in many binary star systems which can potentially increase corona graphic instrument effectivenessWe present the latest testbed results obtained with MSWC as part of the technology development effort focusing on demonstrations conducted on the Occulting Mask Coronagraph (OMC) testbed at JPL during thevacuum test window last winter, with an additional vacuum test planned for this fall. The MSWC mask consists of a shaped pupil mask similar to the one used for the Wide-Field of View mode, but also includes a set of superimposed, regularly-spaced dots that serve as a diffraction grating. OMC has a layout similar to the RomanSpace Telescope coronagraph instrument and configured with a binary imaging mode with a MSWC mask using same design as the contributed mask for the Roman coronagraph. Our testbed results represent the first demonstrations of this technique using the recently installed full binary source. We present results demonstrating suppression in the Super-Nyquist regime for the 3rd diffraction order reaching 8.7e-9 contrast with the Roman pupil. In addition, we present results obtained with a physical binary source and running MSWC in a binary star regime demonstrating 9.6e-8 contrast for a geometry matching potential Alpha Centauri observations in a515 nm monochromatic wavelength (similar but bluer than for Band 1) using the 5th diffraction order. Planned demonstrations in the upcoming vacuum window this fall will focus on Band 3d and Band 4 using the full MSWC mode for an Alpha Centauri geometry.

Roman Coronagraph Instrument↗

A Psychoacoustic Test on the Effect of Masking on Annoyance to Urban Air Mobility Vehicle Noise

Urban Air Mobility (UAM) vehicles have a large range of designs and configurations that lead to new noise characteristics and potentially different perceptual responses when compared to traditional aircraft. In addition, UAM vehicles are expected to operate around and within densely populated regions where the presence of ambient background noise is often present. Strategically, this can be leveraged to inform vehicle design and operations to partially or completely mask UAM noise, allowing for mitigation of negative responses and an increased number of allowed operations. A psychoacoustic test was conducted to investigate how masking effects can influence the annoyance response to a low frequency harmonic tone complex (80-320 Hz). To do this, five test subjects compared their annoyance response to the low frequency tonal noise with a higher frequency broadband noise (10dB down bandwidth between 300-2000 Hz), with and without a masking noise present. Detection thresholds were also measured for both sounds to help fit a model to the data. Although the effect of masking on annoyance is complex, results indicate that for some individuals, masking leads to a lower annoyance than the sound level alone would predict.

Matthew Boucher↗

Mask roughness induced LER: geometric model at long correlation lengths

Collective understanding of how both the resist and line-edge roughness (LER) on the mask affect the final printed LER has made significant advances. What is poorly understood, however, is the extent to which mask surface roughness couples to image plane LER as a function of illumination conditions, NA, and defocus. Recently, progress has been made in formulating a simplified solution for mask roughness induced LER. Here, we investigate the LER behavior at long correlation lengths of surface roughness on the mask. We find that for correlation lengths greater than 3/NA in wafer dimensions and CDs greater than approximately 0.75/NA, the previously described simplified model, which remains based on physical optics, converges to a 'geometric regime' which is based on ray optics and is independent of partial coherence. In this 'geometric regime', the LER is proportional to the mask slope error as it propagates through focus, and provides a faster alternative to calculating LER in contrast to either full 2D aerial image simulation modeling or the newly proposed physical optics model. Data is presented for both an NA = 0.32 and an NA = 0.5 imaging system for CDs of 22-nm and 50-nm horizontal-line-dense structures.

36 MATERIALS SCIENCE↗

Printability and inspectability of Defects on the EUV Mask for sub32nm Half Pitch HVM Application

The availability of defect-free masks remains one of the key challenges for inserting extreme ultraviolet lithography (EUVL) into high volume manufacturing, yet little data is available for understanding native defects on real masks. In this paper, a full field EUV mask is fabricated to see the printability of various defects on the mask. Programmed pit defect shows that minimum printable size of pits could be 17 nm of SEVD from the AIT. However 23.1nm in SEVD is printable from the EUV ADT. Defect printability and identification of its source along from blank fabrication to mask fabrication were studied using various inspection tools. Capture ratio of smallest printable defects was improved to 80% using optimized stack of metrical on wafer and state-of-art wafer inspection tool. Requirement of defect mitigation technology using fiducial mark are defined.

36 MATERIALS SCIENCE↗

Random mask optimization for fast neutron coded aperture imaging

In coded aperture imaging, one of the most important factors determining the quality of reconstructed images is the choice of mask/aperture pattern. In many applications, uniformly redundant arrays (URAs) are widely accepted as the optimal mask pattern. Under ideal conditions, thin and highly opaque masks, URA patterns are mathematically constructed to provide artifact-free reconstruction however, the number of URAs for a chosen number of mask elements is limited and when highly penetrating particles such as fast neutrons and high-energy gamma-rays are being imaged, the optimum is seldom achieved. In this case more robust mask patterns that provide better reconstructed image quality may exist. Through the use of heuristic optimization methods and maximum likelihood expectation maximization (MLEM) image reconstruction, we show that for both point and extended neutron sources a random mask pattern can be optimized to provide better image quality than that of a URA.

McMillan, Kyle↗

Repeatable masking of sensitive data

The various technologies presented herein relate to enabling a value generated based upon a physical unclonable function (PUF) response to be available as needed, while also preventing exposure of the PUF to a malicious entity. A masked PUF response can be generated based upon applying a function to a combination of the PUF response and a data file (e.g., a bitstream), and the masked PUF response is forwarded to a requesting entity, rather than the PUF response. Hence, the PUF is masked from any entity requiring access to the PUF. The PUF can be located in a FPGA, wherein the data file is a bitstream pertinent to one or more configurable logic blocks included in the FPGA. A first masked PUF response generated with a first data file can have a different value to a second masked PUF response generated with a second data file.

Hamlet, Jason↗

The effect of resist on the transfer of line-edge roughness spatial metrics from mask to wafer

Mask contributors to line-edge roughness (LER) have recently been shown to be an issue of concern for both the accuracy of current resist evaluation tests as well the ultimate LER requirements for the 22-nm production node. More recently, it has been shown that the power spectral density of the mask-induced roughness, is markedly different than that of intrinsic resist roughness and thus potentially serves as a mechanism for distinguishing mask effects from resist effects in experimental results. Further considering stochastic resist effects, however, demonstrates that such a test would only be viable in cases where the resist effects are completely negligible in terms of their contribution to the total LER compared to the mask effects. The results presented here lead us to the surprising conclusion that it is indeed possible for mask contributors to be the dominant source of LER while the spatial characteristics of the LER remain indistinguishable from the fractal characteristics of resist-induced LER.

36 MATERIALS SCIENCE↗

Mask roughness and its implications for LER at the 22- and 16-nm nodes

Line-edge roughness (LER) remains the most significant challenge facing the development of extreme ultraviolet (EUV) resist. The mask, however, has been found to be a significant contributor to image-plane LER. This has long been expected based on modeling and has more recently been demonstrated experimentally. Problems arise from both mask-absorber LER as well as mask multilayer roughness leading to random phase variations in the reflected beam and consequently speckle. Understanding the implications this has on mask requirements for the 22-nm half pitch node and below is crucial. Modeling results indicate a replicated surface roughness (RSR) specification of 50 pm and a ruthenium capping layer roughness specification of 440 pm. Moreover, modeling indicates that it is crucial to achieve the current ITRS specifications for mask absorber LER which is significantly smaller than current capabilities.

36 MATERIALS SCIENCE↗

Particle removal challenges with EUV patterned mask for the sub-22nm HP node

The particle removal efficiency (PRE) of cleaning processes diminishes whenever the minimum defect size for a specific technology node becomes smaller. For the sub-22 nm half-pitch (HP) node, it was demonstrated that exposure to high power megasonic up to 200 W/cm{sup 2} did not damage 60 nm wide TaBN absorber lines corresponding to the 16 nm HP node on wafer. An ammonium hydroxide mixture and megasonics removes {ge}50 nm SiO{sub 2} particles with a very high PRE, A sulfuric acid hydrogen peroxide mixture (SPM) in addition to ammonium hydroxide mixture (APM) and megasonic is required to remove {ge}28 nm SiO{sub 2} particles with a high PRE. Time-of-flight secondary ion mass spectroscopy (TOFSIMS) studies show that the presence of O{sub 2} during a vacuum ultraviolet (VUV) ({lambda} = 172 nm) surface conditioning step will result in both surface oxidation and Ru removal, which drastically reduce extreme ultraviolet (EUV) mask life time under multiple cleanings. New EUV mask cleaning processes show negligible or no EUV reflectivity loss and no increase in surface roughness after up to 15 cleaning cycles. Reviewing of defect with a high current density scanning electron microscope (SEM) drastically reduces PRE and deforms SiO{sub 2} particles. 28 nm SiO{sub 2} particles on EUV masks age very fast and will deform over time, Care must be taken when reviewing EUV mask defects by SEM. Potentially new particles should be identified to calibrate short wavelength inspection tools, Based on actinic image review, 50 nm SiO{sub 2} particles on top of the EUV mask will be printed on the wafer.

36 MATERIALS SCIENCE↗

Extreme ultraviolet mask substrate surface roughness effects on lithography patterning

In extreme ultraviolet lithography exposure systems, mask substrate roughness induced scatter contributes to LER at the image plane. In this paper, the impact of mask substrate roughness on image plane speckle is explicitly evaluated. A programmed roughness mask was used to study the correlation between mask roughness metrics and wafer plane aerial image inspection. We find that the roughness measurements by top surface topography profile do not provide complete information on the scatter related speckle that leads to LER at the image plane. We suggest at wavelength characterization by imaging and/or scatter measurements into different frequencies as an alternative for a more comprehensive metrology of the mask substrate/multilayer roughness effects.

36 MATERIALS SCIENCE↗

Beam studies at the SPEAR3 synchrotron using a digital optical mask

The 3GeV SPEAR3 synchrotron light source operates in top-up injection mode with up to 500 mA circulating in the storage ring (equivalently 392 nC). Each injection pulse contains 40–80 pC producing a contrast ratio between total stored charge and injected charge of about 6500:1. In order to study transient injected beam dynamics during user operations, it is desirable to optically image the injected pulse in the presence of the bright stored beam. In the present work this is done by imaging the visible component of the synchrotron radiation onto a digital micro-mirror-array device (DMD), which is then used as an optical mask to block out light from the bright central core of the stored beam. The physical masking, together with an asynchronously-gated, ICCD imaging camera, makes it possible to observe the weak injected beam component on a turn-by-turn basis. The DMD optical masking system works similar to a classical solar coronagraph but has some distinct practical advantages: i.e. rapid adaption to changes in the shape of the stored beam, a high extinction ratio for unwanted light and minimum scattering from the primary beam into the secondary optics. In this paper we describe the DMD masking method, features of the high dynamic range point spread function for the SPEAR3 optical beam line and measurements of the injected beam in the presence of the stored beam.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Thermal Management in Nanofiber-Based Face Mask

Face masks are widely used to filter airborne pollutants, especially when particulate matter (PM) pollution has become a serious concern to public health. Here in this paper, the concept of thermal management is introduced into face masks for the first time to enhance the thermal comfort of the user. A system of nanofiber on nanoporous polyethylene (fiber/nanoPE) is developed where the nanofibers with strong PM adhesion ensure high PM capture efficiency (99.6% for PM 2.5 ) with low pressure drop and the nanoPE substrate with high-infrared (IR) transparency (92.1%, weighted based on human body radiation) results in effective radiative cooling. We further demonstrate that by coating nanoPE with a layer of Ag, the fiber/Ag/nanoPE mask shows a high IR reflectance (87.0%) and can be used for warming purposes. These multifunctional face mask designs can be explored for both outdoor and indoor applications to protect people from PM pollutants and simultaneously achieve personal thermal comfort.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

High-purity Polypropylene from Disposable Face Masks via Solvent-Targeted Recovery and Precipitation

The high use of disposable face masks since the start of COVID-19 has globally generated 4.68–6.24 million tons per year of waste from personal protective equipment. Disposable face masks are generally disposed of in landfills. Polypropylene (PP) is the main component in face masks, which is one of the least recycled plastics but has a high market value. In this work, we extract high-quality PP from face masks using solvent-targeted recovery and precipitation (STRAP) with 90 wt% recovery. N,N-Dimethylacetamide removed the color from the recovered PP to produce a clear high-purity PP, as verified by CIELAB color space. The decolored PP shows similar thermochemical properties and color to virgin PP resin. Here, a techno-economic analysis of the process indicates that high-purity PP recovery can be economically viable at a scale of 5000 tons per year or higher.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

MISR radiometric camera-by-camera Cloud Mask (MIRCCM_V1)

The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The RCCM is derived from the radiance values, and is calculated independently for each camera. Therefore, the amount of apparent cloudiness will vary with view angle, with the oblique view angles generally being more cloudy than the near-nadir ones. Since the RCCM is calculated primarily from the radiance values, it does not work well over snow and ice and will usually confuse clear snow/ice with cloud. It works the best over clear-sky ocean, but other surface types are also of quite good quality. The RCCM product also contains a glint mask for each camera, and this mask is set to true whenever the scattering angles indicate that glint could be possible. This glint mask is not masked out over land; users must do this step themselves. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].

SUN GLINT↗

MISR radiometric camera-by-camera Cloud Mask (MIRCCM_V3)

The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The RCCM is derived from the radiance values, and is calculated independently for each camera. Therefore, the amount of apparent cloudiness will vary with view angle, with the oblique view angles generally being more cloudy than the near-nadir ones. Since the RCCM is calculated primarily from the radiance values, it does not work well over snow and ice and will usually confuse clear snow/ice with cloud. It works the best over clear-sky ocean, but other surface types are also of quite good quality. The RCCM product also contains a glint mask for each camera, and this mask is set to true whenever the scattering angles indicate that glint could be possible. This glint mask is not masked out over land; users must do this step themselves. [Location=GLOBAL] [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].

CLOUD MASK↗

MISR radiometric camera-by-camera Cloud Mask (MIRCCM_V4)

The MISR instrument consists of nine pushbroom cameras which measure radiance in four spectral bands. Global coverage is achieved in nine days. The cameras are arranged with one camera pointing toward the nadir, four cameras pointing forward and four cameras pointing aftward. It takes 7 minutes for all nine cameras to view the same surface location. The view angles relative to the surface reference ellipsoid, are 0, 26.1, 45.6, 60.0, and 70.5 degrees. The spectral band shapes are nominally gaussian, centered at 443, 555, 670, and 865 nm. The RCCM is derived from the radiance values, and is calculated independently for each camera. Therefore, the amount of apparent cloudiness will vary with view angle, with the oblique view angles generally being more cloudy than the near-nadir ones. Since the RCCM is calculated primarily from the radiance values, it does not work well over snow and ice and will usually confuse clear snow/ice with cloud. It works the best over clear-sky ocean, but other surface types are also of quite good quality. The RCCM product also contains a glint mask for each camera, and this mask is set to true whenever the scattering angles indicate that glint could be possible. This glint mask is not masked out over land; users must do this step themselves. [Temporal_Coverage: Start_Date=2000-02-24; Stop_Date=] [Spatial_Coverage: Southernmost_Latitude=-90; Northernmost_Latitude=90; Westernmost_Longitude=-180; Easternmost_Longitude=180].

SUN GLINT↗

New Neural Network Cloud Mask Algorithm Based on Radiative Transfer Simulations

Cloud detection and screening constitute critically important first steps required to derive many satellite data products. Traditional threshold-based cloud mask algorithms require a complicated design process and fine tuning for each sensor, and they have difficulties over areas partially covered with snow/ice. Exploiting advances in machine learning techniques and radiative transfer modeling of coupled environmental systems, we have developed a new, threshold-free cloud mask algorithm based on a neural network classifier driven by extensive radiative transfer simulations. Statistical validation results obtained by using collocated CALIOP and MODIS data show that its performance is consistent over different ecosystems and significantly better than the MODIS Cloud Mask (MOD35 C6) during the winter seasons over snow-covered areas in the mid-latitudes. Simulations using a reduced number of satellite channels also show satisfactory results, indicating its flexibility to be configured for different sensors. Comparedto threshold-based methods and previous machine-learning approaches, this new cloud mask (i) does not rely on thresholds, (ii) needs fewer satellite channels, (iii) has superior performance during winter seasons in mid-latitude areas, and (iv) can easily be applied to different sensors.

cloud mask algorithms↗

Face mask integrated with flexible and wearable manganite oxide respiration sensor

Face masks are key personal protective equipment for reducing exposure to viruses and other environmental hazards such as air pollution. Integrating flexible and wearable sensors into face masks can provide valuable insights into personal and public health. The advantages that a breath-monitoring face mask requires, including multi-functional sensing ability and continuous, long-term dynamic breathing process monitoring, have been underdeveloped to date. Here, we design an effective human breath monitoring face mask based on a flexible La 0.7 Sr 0.3 MnO 3 (LSMO)/Mica respiration sensor. The sensor’s capabilities and systematic measurements are investigated under two application scenes, namely clinical monitoring mode and daily monitoring mode, to monitor, recognise, and analyse different human breath status, i.e., cough, normal breath, and deep breath. This sensing system exhibits super-stability and multi-modal capabilities in continuous and long-time monitoring of the human breath. We determine that during monitoring human breath, thermal diffusion in LSMO is responsible for the change of resistance in flexible LSMO/Mica sensor. Both simulated and experimental results demonstrate good discernibility of the flexible LSMO/Mica sensor operating at different breath status. Our work opens a route for the design of novel flexible and wearable electronic devices.

36 MATERIALS SCIENCE↗