Search NASA⌕ Search

SEARCH · Search NASA

Results for “MeV gamma ray”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

High-energy emission from a magnetar giant flare in the Sculptor galaxy

Magnetars are the most highly magnetized neutron stars in the cosmos (with magnetic field 10 13 –10 15 G). Giant flares from magnetars are rare, short-duration (about 0.1 s) bursts of hard X-rays and soft γ rays. Owing to the limited sensitivity and energy coverage of previous telescopes, no magnetar giant flare has been detected at gigaelectronvolt (GeV) energies. Here, we report the discovery of GeV emission from a magnetar giant flare on 15 April 2020 (refs. 3,4 and A. J. Castro-Tirado et al., manuscript in preparation). The Large Area Telescope (LAT) on board the Fermi Gamma-ray Space Telescope detected GeV γ rays from 19 s until 284 s after the initial detection of a signal in the megaelectronvolt (MeV) band. Our analysis shows that these γ rays are spatially associated with the nearby (3.5 megaparsecs) Sculptor galaxy and are unlikely to originate from a cosmological γ-ray burst. Thus, we infer that the γ rays originated with the magnetar giant flare in Sculptor. Furthermore, we suggest that the GeV signal is generated by an ultra-relativistic outflow that first radiates the prompt MeV-band photons, and then deposits its energy far from the stellar magnetosphere. After a propagation delay, the outflow interacts with environmental gas and produces shock waves that accelerate electrons to very high energies; these electrons then emit GeV γ rays as optically thin synchrotron radiation. This observation implies that a relativistic outflow is associated with the magnetar giant flare, and suggests the possibility that magnetars can power some short γ-ray bursts.

79 ASTRONOMY AND ASTROPHYSICS↗

Phenomenology of bubble size distributions in a first-order phase transition

In a cosmological first-order phase transition (FOPT), the true and false vacuum bubble radius distributions are not expected to be monochromatic, as is usually assumed. Consequently, Fermi balls (FBs) and primordial black holes (PBHs) produced in a dark FOPT will have extended mass distributions. We show how gravitational wave (GW), microlensing and Hawking evaporation signals for extended bubble radius/mass distributions deviate from the case of monochromatic distributions. The peak of the GW spectrum is shifted to lower frequencies, and the spectrum is broadened at frequencies below the peak frequency. Thus, the radius distribution of true vacuum bubbles introduces another uncertainty in the evaluation of the GW spectrum from a FOPT. The extragalactic gamma-ray signal at AMEGO-X/e-ASTROGAM from PBH evaporation may evince a break in the power-law spectrum between 5 MeV and 10 MeV for an extended PBH mass distribution. Optical microlensing surveys may observe PBH mass distributions with average masses below 10 -10 M ⊙ , which is not possible for monochromatic mass distributions. This expands the FOPT parameter space that can be explored with microlensing.

Marfatia, Danny [Univ. of Hawaii at Manoa, Honolul↗

Photonuclear cross sections for 197 Au: An update on the gold standard

Cross sections for the 197 Au(γ, n) reaction are broadly used in nuclear physics as a standard for normalizing photonuclear reaction cross-section data at photon beam energies above approximately 8 MeV. In this paper, we report cross-section measurements for the 197 Au(γ, n) 196 Au g+m1 reaction at beam energies from 13 to 31 MeV. Our measurements provide the first cross-section data for this reaction at beam energies above 20 MeV, enabling the use of this reaction as a cross-section standard up to 30 MeV. Also, this work provides first cross-section measurements for the 197 Au(γ, n) 196 Au m2 reaction. In addition, we measured cross-section data for the 197 Au(γ, 3n) 194 Au reaction, which can be used as a cross-section standard above about 25 MeV. These measurements were performed using a new target activation method that is based on the angle-energy correlation of the laser Compton- scattered photon beams at the High Intensity Gamma-ray Source (HIγS). The technique enables measuring photonuclear reaction cross-sections at several discrete beam energies concurrently via a single irradiation on a stack of different targets. Measurements were carried out by irradiating a stack of concentric-ring targets consisting of Au, TiO 2 , Zn, Os, and Au (in order of the γ-ray beam direction). Our data for the 197 Au(γ,n) 196 Au g+m1 reaction in the energy range of 13 to 20 MeV are in good agreement with existing ones measured using monoenergetic γ-ray beams, but differ from data acquired using a bremsstrahlung γ-ray beam. Also, above 18 MeV, our data for the 197 Au(γ,n) 196 Au g+m1 and 197 Au(γ,n) 196 Au m2 reactions differ significantly from the most recent TENDL and JENDL evaluations, suggesting a need to update these data libraries. Furthermore, the TENDL evaluation and existing data are consistent with our data for the 197 Au(γ,3n) reaction, but differ significantly from the JENDL evaluation above 26 MeV.

190 ≤ A ≤ 219↗

Compact X-band split electron linac for cabinet-size small-sample irradiators

Many small-scale industrial radiation facilities rely on hazardous radioisotope-based gamma ray irradiators, which are being gradually replaced by alternative technologies, such as particle accelerators. RadiaBeam has developed a compact, cabinet-size, 3 MeV electron-linac-based irradiator to match the penetration of Co-60 and provide high irradiation throughput. Here the linac utilizes X-band RF power to reduce size, employs an innovative split-linac approach to lower costs, and features a novel X-ray conversion target geometry that spreads the beam out across the target, providing a low dose uniformity ratio. In this paper, we discuss the accelerator design, fabrication, and test results.

43 PARTICLE ACCELERATORS↗

Quantum enabled precision measurements of the 229Th nuclear isomer transition (final report)

The existence of the nuclear isomer transition in thorium-229 was first inferred from keV lines in the gamma spectrum of uranium-233 decay more than 40 years ago. Over the years, the value of the transition energy has been refined with indirect measurements using nuclear physics techniques, and the current evidence points to transition energy in the laser-accessible vacuum ultra-violet region of the spectrum. At the start of this project, the two best measurements of the transition energy were 7.8±0.5 eV and 8.28±0.17 eV from high precision gamma ray spectroscopy and kinetic energy of internal conversion electrons, respectively. This project aimed to reduce the uncertainty in the transition energy to 10 meV using direct calorimetric measurements of the decay energy with superconducting nanowire single photon detectors (SNSPDs). Specifically, the method that was pursued was to generate thorium-229 in the excited isomer state by the alpha decay of uranium-233, embed the excited state thorium into an SNSPD, then detect the energy released when the isomer deexcites.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Hazma meets HERWIG4DM: precision gamma-ray, neutrino, and positron spectra for light dark matter

Herein we present a new open-source package, Hazma 2, that computes accurate spectra relevant for indirect dark matter searches for photon, neutrino, and positron production from vector-mediated dark matter annihilation and for spin-one dark matter decay. The tool bridges across the regimes of validity of two state of the art codes: Hazma 1, which provides an accurate description below hadronic resonances up to center-of-mass energies around 250 MeV, and Herwig4DM, which is based on vector meson dominance and measured form factors, and accurate well into the few GeV range. The applicability of the combined code extends to approximately 1.5 GeV, above which the number of final state hadrons off of which we individually compute the photon, neutrino, and positron yield grows exceedingly rapidly. We provide example branching ratios, particle spectra and conservative observational constraints from existing gamma-ray data for the well-motivated cases of decaying dark photon dark matter and vector-mediated fermionic dark matter annihilation. Finally, we compare our results to other existing codes at the boundaries of their respective ranges of applicability. Hazma 2 is freely available on GitHub athttps://github.com/LoganAMorrison/Hazma.

79 ASTRONOMY AND ASTROPHYSICS↗

A compact and portable gamma-ray spectrometer (GRASP) for inertial confinement fusion and basic science experiments

A compact and portable gamma-ray spectrometer has been designed to diagnose different components of the inertial confinement fusion-relevant γ-ray spectrum with energies between ∼3.7–17.9 MeV. The system is designed to be as compact as possible for convenient transportation and fielding in diagnostic ports on the OMEGA laser, the National Ignition Facility, and other photon-source facilities. The system consists of a conversion foil for Compton scattering in front of four magnetic spectrometer “arms,” each covering a different energy range and constructed out of cylindrical permanent magnet Halbach arrays. Monte Carlo simulations have been used to optimize and assess the performance of the conversion foil, and COSY INFINITY ion-optical simulations have been used to optimize the spectrometer magnets. The performance of the design is assessed for a simulated direct-drive γ-ray spectrum. Spanning its total γ-ray energy bandwidth and using a 1.7 mm thick boron conversion foil, the system’s total energy resolution and efficiency are ∼15.8%–4.5% and 5.4 × 10−7–3.7 × 10−7e−/γ, respectively, with room for improvement. Spectral γ-ray measurements will provide guidance to the inertial confinement fusion program toward achieving high-energy gain relevant to inertial fusion energy and enable new measurement capabilities for basic discovery science.

Instruments & Instrumentation↗

Connecting Nuclear Structure to Stellar Astrophysics: Neutron Skin in Tin Isotopes

The first observation of a neutron star merger by the LIGO-Virgo collaboration in 2017 highlights the need to improve our fundamental understanding of the equation of state of dense, neutron rich matter. The origin of heavy elements in the r-process and the structure of neutron stars are governed by the properties of neutron rich matter, for which experimental data is limited. Further analysis of this historic event and all future neutron star mergers relies on constraining the nuclear equation of state with experimental observables. We propose a novel method for systematically studying the evolution of the neutron skin in stable tin isotopes, by measuring the low-energy nuclear dipole strength over the broadest possible range of neutron-to-proton ratios in a single element. Nuclear resonance fluorescence with 100% linearly polarized photons from the High Intensity Gamma-ray Source (HIGS) facility was used to selectively measure the E1 photoabsorption strength of 112 Sn and 124 Sn at excitation energies from 3.5 MeV up to neutron separation, where the Pygmy Dipole Resonance dominates. The dipole polarizabilities of 112 Sn and 124 Sn were measured to be 9.03 ± 0.23 fm 3 and 9.11 ± 0.24 fm 3 , respectively. These uniquely systematically consistent measurements provide highly accurate experimental data for improving microscopic nuclear models as well as calculations of astrophysical nucleosynthesis and neutron star structure.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Solar Neutrino Detection with a Pixelated Liquid-Argon Time Projection Chamber

This thesis presents a study of low-energy solar neutrino detection using large-scale LArTPCs, focussing on novel pixelated readout technologies. Solar neutrinos offer a unique probe of fundamental neutrino properties and solar physics, but their detection in the MeV range is challenged by backgrounds. We investigate two complementary technologies: SoLAr, which integrates LArPix-based pixelated charge collection with Silicon Photomultipliers (SiPMs) in a hybrid anode design for simultaneous charge and light detection; and Q-Pix, a triggerless pixelated readout architecture based on charge integrate-reset circuits with local clocks, where Reset Time Differences encode ionisation waveforms via time-to-charge conversion. Two SoLAr prototypes were developed and operated, demonstrating VUV-sensitive SiPM performance in liquid argon and accurate charge-light signal matching with a charge detection threshold of $\sim 100 \mathrm{keV}$. We also implement a complete simulation and reconstruction framework, incorporating realistic detector geometry, electron transport, readout response, and detailed signal and background models, including intrinsic argon and radon progeny, as well as site-specific $\gamma$-ray and neutron fluxes. For Q-Pix, we demonstrate that with a pixel size of $4\times 4$ mm$^2$ and a reset threshold of 1 fC ($\sim 0.1475$ MeV), full-scale operation produces data volumes below 1 PB per 10 ktonne-year. For SoLAr, assuming a shielded DUNE-like detector and 100 ktonne-year exposure, we project uncertainties of $0.90\times 10^{-5}$ eV$^2$ on $\Delta m^2_{21}$ and 0.033 on $\sin^2\theta_{12}$, improving to $0.46\times 10^{-5}$ eV$^2$ and 0.025 with 400 kilotonne-year. At this higher exposure, we also obtain a day–night flux asymmetry at the level of $( -5.6 \pm 3.6 ) \%$. Combining Monte Carlo modelling, hardware validation, and advanced reconstruction techniques, this work establishes a path toward next-generation ktonne-scale LArTPCs as observatories for precision solar neutrino physics.

Ruiz Ferreira, Guilherme [Manchester U.] (ORCID:00↗

Isotopic analysis of plutonium measured with very thick absorbers and high-granularity spectra

FRAM is LANL-designed software designed to extract plutonium and uranium isotopic information from gamma ray spectra. This is an important capability for NEST and STAB; however, FRAM performance has been poor when applied to field data collected in these programs. FRAM Version 5 (commercially available) was fine-tuned and validated for laboratory quality measurements but not for measurements of the high-mass and heavily shielded SNM items encountered in NEST. FRAM is untested for spectra collected with high-granularity lower resolution instruments such as the new 8-MeV Detective-X favored by STAB or the new custom electrocooled systems coming into use for NEST. FRAM Version 6.1 (unreleased) has improvements in physics capabilities, and parameter sets may be adapted that are more specific to NEST and STAB, which is what we have attempted for this assignment. Thick shielding attenuates gamma rays profoundly, especially those at low energy, making them too weak to be measured. The missing low-energy peaks force the analysis to employ only the highest-energy peaks. We adapted FRAM 6.1 for analysis of plutonium spectra obtained with very thick Pb filters (a surrogate for NEST-type configurations). New parameter sets employing only very high energy peaks were created for the analysis. High granularity and low resolution make deconvolution of the 600-keV region particularly challenging, and we have worked to optimally extract information from this region. The results shown in this paper give high confidence that we are on the right track. We used a combination of real and synthetically-modified data. Remaining work includes testing the new software and parameters against genuine data collected with Detective-X and new NEST systems, but such datasets at the moment are unavailable. It also remains to develop and test parameter sets specific to uranium and the new detectors.

07 ISOTOPE AND RADIATION SOURCES↗

Superconducting RF Gun with High Current and the Capability to Generate Polarized Electron Beams

High-current low-emittance CW electron beams are indispensable for nuclear and high-energy physics fixed target and collider experiments, cooling high energy hadron beams, generating CW beams of monoenergetic X-rays (in FELs) and gamma-rays (in Compton sources). Polarization of electrons in these beams provides extra value by opening a new set of observables and frequently improving the data quality. We report on the upgrade of the unique and fully functional CW SRF 1.25 MeV SRF gun, built as part of the Coherent electron Cooling (CeC) project, which has demonstrated sustained CW operation with CsK2Sb photocathodes generating electron bunches with record-low transverse emittances and record-high bunch charge exceeding 10 nC. We propose to extend the capabilities of this system to high average current of 100 milliampere in two steps: increasing the current 30-fold at each step with the goal to demonstrate reliable long-term operation of the high-current low-emittance CW SRF guns. We also propose to test polarized GaAs photocathodes in the ultra-high vacuum (UHV) environment of the SRF gun, which has never been successfully demonstrated in RF accelerators.

43 PARTICLE ACCELERATORS↗

Investigating the FLASH Effect in a Rat Brain Organotypic Model With a Novel High-Energy Electron Beam

Ultrahigh dose rate (FLASH) radiation therapy is reported to reduce normal tissue toxicity while maintaining tumor control; however, mechanism(s) remain obscure. To study FLASH mechanisms in brain tissue, we developed a novel experimental platform featuring a specialized high-energy electron linear accelerator, High Intensity Gamma Ray Source (HIGS), paired with an organotypic ex vivo brain metastasis model. We varied interpulse spacing to modulate the mean dose rate (MDR) of our unique 35 MeV electron beam, while maintaining extremely high instantaneous dose rate (IDR). We characterized dosimetry and targeting accuracy of the FLASH beam with film dosimetry. We combined this FLASH beam with an organotypic rat brain slice/breast carcinoma coculture model of brain metastasis to assess effects on normal and neoplastic tissues. Live-cell and bioluminescence imaging demonstrated cancer cell growth effects, whereas normal tissue responses and immune activation were assessed using live-cell imaging, cytokine profiles, and confocal microscopy. Here, we performed comparison experiments with 20 MeV electrons from a Varian clinical linear accelerator (VCLA) using conventional dose rates. The highest IDR of the FLASH beam to date was 20.7 ± 0.6 MGy/s, with maximum MDR of 20.7 MGy/s delivered in 1 pulse of 1 µs duration. Beam targeting was accurate to <1 mm and reproducible. HIGS-FLASH and VCLA dose rates equivalently decreased cancer cell growth. HIGS-FLASH irradiation significantly increased tumor necrosis factor α and fractalkine levels and confocal microscopy revealed distinct changes in microglial morphology slices suggesting microglia activation. Our novel experimental platform produces extremely high dose rates and rapid normal/neoplastic tissue readouts for mechanistic research into the effects of FLASH radiation in the brain. HIGS-FLASH irradiation induces comparable cancer cell growth inhibition but differential effects on cytokines and microglial morphology, suggesting that acute innate immune responses may be involved in FLASH normal tissue effects in the brain.

Kay, Tyler V. [Duke University, Durham, NC (United↗

Potential neutron-induced γ-ray background on natural tellurium relevant to 130 Te 0 ν ββ decay searches at the CUORE and SNO+ detectors

Gamma-ray production cross-section data have been obtained for the inelastic neutron scattering reactions 126,128,130 Te(n,n'γ) at five neutron energies between 3.6 and 10 MeV. We report data for the γ-ray energy region relevant to 0ν ββ decay of 130 Te with a Q ββ value of 2527.515 keV, assuming natural-abundance tellurium, as used at CUORE and SNO+. The natural abundance of 130 Te, 128 Te, and 126 Te is 34%, 32%, and 19%, respectively. For CUORE the γ-ray cascades from the excited state in 130 Te at 2527.06 keV and in 126 Te at 2533.85 keV are of concern. For SNO+, accounting for its inferior energy resolution, an additional four levels are important in 130 Te, an additional nine levels in 128 Te, and an additional eight levels in 126 Te. Of these, we report neutron-induced γ-ray production cross sections for the strongest transitions: the 2581.15 keV level in 130 Te, the 2494.20, 2508.06, and 2630.14 keV levels in 128 Te, and the 2496.83 and 2585.46 keV level in 126 Te. Here, the largest cross-section values were found for cascade γ-ray transitions to the ground state, while direct transitions to the ground state are very weak and were not observed in the present work. Both the CUORE and SNO+ detectors, however, may not be able to distinguish between cascade transitions and direct transitions to the ground state, making the neutron-induced excitation of the 2527.06 keV state of 130 Te in particular a potential problem for 0νββ decay searches of 130Te, because it matches its Q ββ value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction of the non-spin- and spin-transfer isovector responses via the 12 C ⁡( 10 Be, 10 B + 𝛾)⁢ 12 B reaction

The isovector response in 12 B was investigated via the 12 C ⁡( 10 Be, 10 B + 𝛾)⁢ 12 B* reaction at 100⁢𝐴MeV. By utilizing the 𝛾-decay properties of the 1.74 MeV 0 + and 0.718 MeV 1 + states in 10 B, the separate extraction of the non-spin-transfer (Δ⁢𝑆 = 0) and spin-transfer (Δ⁢𝑆 = 1) isovector responses up to an excitation energy of 50 MeV in 12 B in a single measurement is demonstrated. The experimental setup employed the S800 spectrometer to detect and analyze the 10 B ejectiles and the Gamma-Ray Energy Tracking In-beam Nuclear Array (GRETINA) for obtaining the Doppler-reconstructed spectrum for 𝛾 rays emitted in flight by 10 B. A 12 C foil was placed at the pivot point of the spectrograph. Here, the 12 B reaction product was not detected. Contributions from transitions associated with the transfer of different units of angular momentum in the non-spin- and spin-transfer responses were analyzed using a multipole decomposition analysis. The extracted non-spin-dipole (Δ⁢𝑆 = 0, Δ⁢𝐿 = 1) and spin-dipole (Δ⁢𝑆 = 1, Δ⁢𝐿 = 1) responses were found to be consistent with available data from other charge-exchange probes, validating the non-spin- and spin-transfer filters used. While statistical uncertainties and experimental resolutions were relatively large due to the modest intensity of the 10 Be secondary beam, the results show that, with the much higher intensities that will be available at new rare-isotope beam facilities, the ( 10 Be, 10 B + 𝛾) reaction and its Δ⁢𝑇 𝑧 = −1 partner, the ( 10 C, 10 B + 𝛾) reaction, are powerful tools for elucidating the isovector non-spin- and spin-transfer responses in nuclei.

Charge-exchange reactions↗

Demonstrating MeV-Scale Physics Capabilities of Large Neutrino LArTPCs with Ambient Blip Activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by incorporating isolated MeV-scale features present in their data. We use data from MicroBooNE, an 85 tonne LArTPC exposed to Fermilab neutrino beams from 2015 until 2021, to demonstrate new calorimetric and particle discrimination capabilities for isolated ~O(1 MeV) energy depositions referred to as "blips". We observe concentrations of blips near fiberglass support struts along the TPC edge, with an energy spectrum indicative of specific gamma-ray decays. These and other blip sources are being used to validate calibrations in MicroBooNE's data by leveraging spectral features. This work further reports on the progress towards distinguishing between low-energy protons and electrons in large LArTPCs using cosmogenic data. The composition of proton-like blips selected using this new technique is being studied to evaluate the accuracy of cosmic ray flux models used in LArTPCs

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstrating MeV-Scale Physics Capabilities of Large Neutrino LArTPCs with Ambient Blip Activity in MicroBooNE

Large neutrino liquid argon time projection chamber (LArTPC) experiments can broaden their physics reach by incorporating isolated MeV-scale features present in their data. We use data from MicroBooNE, an 85 tonne LArTPC exposed to Fermilab neutrino beams from 2015 until 2021, to demonstrate new calorimetric and particle discrimination capabilities for isolated ~O(1 MeV) energy depositions referred to as "blips". We observe concentrations of blips near fiberglass support struts along the TPC edge, with an energy spectrum indicative of specific gamma-ray decays. These and other blip sources are being used to validate calibrations in MicroBooNE's data by leveraging spectral features. This work further reports on the progress towards distinguishing between low-energy protons and electrons in large LArTPCs using cosmogenic data. The composition of proton-like blips selected using this new technique is being studied to evaluate the accuracy of cosmic ray flux models used in LArTPCs

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Hunting for gamma-ray emission from fast radio bursts

Context. Fast radio bursts (FRBs) are a recently discovered class of GHz-band, ms-duration, Jansky-level-flux astrophysical transients. Although hundreds of models have been proposed so far for FRB progenitors (the most popular ones involve magnetars), their physical origin and emission mechanism are still a mystery, making them one of the most compelling problems in astrophysics. Aims. FRBs are caused by astrophysical processes that are not yet understood. Exploring their high-energy counterpart is crucial for constraining their origin and emission mechanism. Methods. Thanks to more than 13 years of gamma-ray data collected by the Large Area Telescope on board the Fermi Gamma-ray Space Telescope, and to more than 1000 FRB events (from 561 non-repeating and 22 repeating sources), one of the largest samples created thus far, we performed the largest and deepest search for high-energy emission from FRB sources to date (between 100 MeV and 1 TeV). In addition to the analysis involving individual FRB events on different timescales (from a few seconds up to several years), we performed, for the first time, a stacking analysis on the full sample of FRB events as well as a search for triplet photons in coincidence with the radio event. Results. We do not detect significant emission, reporting the most stringent constraints, on short timescales, for the FRB-like emission from SGR 1935+2154 with E γ <10 41 erg, corresponding to a factor η < 10 7 with respect to the emitted radio energy. Similarly, for the stacked signal of steady emission from all repeaters, the obtained upper limit (UL) on the FRBs luminosity (L γ < 1.6 × 10 43 erg s -1 is more than two orders of magnitude lower than those derived from the individual sources. Finally, no individual or triplet photons have been significantly associated with FRB events. We derived the LAT ms-sensitivity to be ~0.3 ph cm -2 s -1 and constrained the gamma-ray energy E γ,δT = 1 ms ≲ 10 47 (D L /150 Mpc) 2 erg, ruling out a gamma-ray-to-radio energy ratio greater than 10 9 on ms timescales. Conclusions. The results reported here represent the most stringent UL reported so far on the high-energy emission from FRBs on short and long time scales, as well as on cumulative emission and individual photon searches. While the origin of FRBs is still unclear, our work provides important constraints for FRB modelling, which might shed light on their emission mechanism.

79 ASTRONOMY AND ASTROPHYSICS↗

Gamma-ray Spectroscopy in Low-Power Nuclear Research Reactors

Gamma-ray spectroscopy is an effective technique for radioactive material characterization, routine inventory verification, nuclear safeguards, health physics, and source search scenarios. Gamma-ray spectrometers typically cannot be operated in the immediate vicinity of nuclear reactors due to their high flux fields and their resulting inability to resolve individual pulses. Low-power reactor facilities offer the possibility to study reactor gamma-ray fields, a domain of experiments hitherto poorly explored. In this work, we present gamma-ray spectroscopy experiments performed with various detectors in two reactors: The EPFL zero-power research reactor CROCUS, and the neutron beam facility at the Ohio State University Research Reactor (OSURR). We employed inorganic scintillators (CeBr3), organic scintillators (trans-stilbene and organic glass), and high-purity germanium semiconductors (HPGe) to cover a range of typical—and new—instruments used in gamma-ray spectroscopy. The aim of this study is to provide a guideline for reactor users regarding detector performance, observed responses, and therefore available information in the reactor photon fields up to 2 MeV. The results indicate several future prospects, such as the online (at criticality) monitoring of fission products (like Xe, I, and La), dual-particle sensitive experiments, and code validation opportunities.

Pakari, Oskari V. (ORCID:0000000337048190)↗