Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measured Response”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

Nanoscale Polarization-Dependent Young’s Modulus of Ferroelectric BaTiO 3 Single Crystals

Flexoelectric fields produced by strong strain gradients at the nanoscale couple to ferroelectric polarization, promoting changes in the mechanical properties of ferroelectric materials as a function of the direction of the ferroelectric polarization. In this work, we calculate the asymmetry in the Young’s modulus found in oppositely polarized out-of-plane domains of BaTiO 3 single crystals by means of contact resonance AFM, and we evaluate its impact on the electromechanical response as measured by piezoresponse force microscopy, both using band excitation modes. Furthermore, we analyze the electromechanical response of the different BaTiO 3 domains using k-means to build up their mean elastic and electromechanical features and quantify the flexoelectrically induced modulation of the Young’s modulus. Finally, we discuss the use of contact Kelvin probe force microscope measurements to decouple electrostatic artifacts from purely piezoelectric ones when flexoelectric coupling appears.

BaTiO 3 single crystals↗

Spectral Effects in Albedo and Rearside Irradiance Measurement for Bifacial Performance Estimation

We investigate the impact of spectral dependence of ground surface reflectivity on albedo and rearside irradiance measurements necessary for bifacial photovoltaic (PV) module performance estimation and monitoring. Because PV modules are spectrally selective, albedo and irradiance measurements performed with common irradiance sensors may require spectral mismatch corrections when used for performance prediction. We investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystalline silicon PV reference cells in comparison to a typical crystalline-silicon bifacial PV module. Simulations are performed for nine different representative ground surface materials using simulated solar spectra together with spectral reflectivity data distributed with the SMARTS simulation software. For the materials considered, the results show that albedo spectral mismatch relative to the bifacial module is distributed over a range of ±9.2% for thermopile pyranometers versus only ±3.7% for a typical PV reference cell. We consider the impact of this spectrally-responsive albedo mismatch on bifacial PV module rearside irradiance measurements. Using synthesized rearside spectral irradiance distributions, we find that for the nine different ground surface materials the predicted rearside irradiance measurement deviates from the effective irradiance observed by the PV module by on the order of 16.5 W/m 2 for the pyranometer and 3.6 W/m 2 for the PV reference cell. We discuss the implications for bifacial albedo and irradiance measurement.

41 EE - Solar Energy Technologies Office (EE-4S)↗

Radiation-induced bowing of SiC/SiC composites under neutron flux gradients—integral experimental data for model validation

Here, the radiation-induced swelling of SiC and its composites, including strong dependencies on temperature and dose, can drive significant lateral bowing in the presence of temperature and/or dose gradients. In recent years, simulations have been performed to assess the extent of bowing in SiC composite light-water reactor (LWR) fuel cladding and boiling water reactor (BWR) channel boxes. However, to date, no integral experimental data exist to validate these models. This work provides the first experimental bowing evaluation of three ∼380 mm long SiC composite specimens irradiated under varying neutron dose gradients (∼50°C–60°C, 0.03–0.06 dpa): two tubes (∼9.8 mm diameter) and a miniature BWR channel box (∼30 mm square). The measured radiation-induced length swelling (∼0.3%–0.7% linear) was consistently 10%–21% higher than values obtained from 3D finite element structural analyses with inputs from 3D radiation transport calculations. This discrepancy could be at least partially explained by differences in dose rate (∼10 -8 dpa/s) compared to the literature data (∼10-6 dpa/s) used to establish the dose-to-swelling correlations in the model. Nevertheless, the modeled bowing magnitudes (<2 mm) obtained from finite element analyses and simple analytical equations were within the bounds of the experimental measurements for all specimens. With improved confidence in the ability to predict the structural response and measure the macroscopic deformations, future experiments will target transient bowing under neutron flux gradients at representative LWR temperatures and assess whether grid spacers can mitigate the tens of millimeters of bowing that would otherwise be expected in ∼4 m long LWR components.

bowing↗

Spectral Effects in Albedo and Rearside Irradiance Measurment for Bifacial Performance Estimation: Preprint

Albedo data are essential for accurate prediction of bifacial PV module performance. However, spectral response mismatch between PV modules and irradiance sensors used in albedometers can limit the accuracy of performance predictions. In order to provide quantitative assessment of this effect, we investigate via simulation the differences in spectrally responsive albedo measured with thermopile pyranometers and crystallinesilicon PV reference cells in comparison to a representative crystalline-silicon bifacial PV module for nine different representative ground surface materials. Calculations are performed using simulated solar spectra together with catalogued spectral reflectivity data distributed with the SMARTS simulation software. For the specific materials considered, the results show that albedo measurement using thermopile pyranometers could over or under-estimate the ground-reflected radiation usable by a bifacial PV module by up to 10%, versus only approximately 4% total range of variation for a PV reference cell.

Albedo↗

Fast neutron leakage spectra of the EUCLID experiment

Special nuclear material in sub-critical and critical configurations measured in integral experiments are important for validation and adjustment of nuclear data. Many different evaluations of nuclear data exist, and these different evaluations can provide different values for individual cross sections that vary due to the uncertainties in differential experiments or lack of such data. For integral experiments, differences in these individual cross sections can have compensating errors, which lead to the same answer. One example of this is the Jezebel critical assembly, where k eff of the system is correctly computed by both ENDF/B-VIII.0 and JEFF-3.3, despite having substantially different underlying evaluated values for specific reactions (such as elastic and inelastic cross sections). To reduce compensating errors in nuclear data, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project has utilized machine learning to design a set of sub-critical and critical experiments. These experiments include slab- and cube-like configurations of 239 Pu in the form of the ZPPR plates. Six different responses were measured on a total of thirteen different configurations. One of these responses, the neutron leakage spectrum, was measured using an EJ301D detector. Finally, the results of the neutron leakage spectra show good agreement (within 1–2 σ ) with the expected spectrum from simulations and will be used in the subsequent nuclear data adjustment done by the EUCLID team.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Advanced Performance Metrics and their Application to the Sensitivity Analysis for Model Validation and Calibration

High-quality generator dynamic models are critical to reliable and accurate power systems studies and planning. With the availability of PMUs, measurement-based approach for model validation has gained significant prominence. In this approach, the quality of a model is analyzed by visually comparing measured generator response with the model-based simulated response for large system disturbances. This paper proposes a new set of performance metrics to assess the model validation results to facilitate automation of the model validation process. In the proposed methodology, first, the slow governor response and comparatively faster oscillatory response are separated, and then a separate set of performance metrics is calculated for each of these two components. These proposed metrics quantify the mismatch between the actual and model-based response in a comprehensive manner without missing any information enabling automation of the process. Furthermore, in this paper, we are also proposing that the sensitivity analysis for model calibration be performed with respect to the proposed metrics for the systematic identification of key parameters. In this work, results obtained using both simulated and real-world case-studies validate the effectiveness of the proposed performance metrics for model validation and their application to the sensitivity analysis for model calibration.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Electron Spin Polarization in Large Electric Fields

This project investigated the effects of large electric fields on electron spin polarization in semiconductors, which is of interest for spin-based electronics (“spintronics”) and quantum information processing. It has been theoretically proposed that large electric fields could potentially preserve or amplify electron spin polarization, which would make it easier to generate, transport, and detect spin polarization in spin-based devices; however, previous measurements had not measured the response of electron spin polarization at large electric fields. During this project, methods to perform measurements of electron spin polarization at large electric fields were developed and performed using ultrafast time- and spatially-resolved magneto-optical spectroscopy, high-voltage pulses, and lock-in detection. The device geometry was engineered to reduce the threshold voltage required to reach the Gunn threshold, and the effect of optical illumination on the sample conductivity and Gunn oscillations was investigated. Electron spin polarization measurements were performed at electric fields up to and beyond the Gunn threshold for the device. The measurements showed that the electron spin polarization magnitude decreased with increasing electric field in the devices measured, and a spin amplification effect was not observed. However, these effects could potentially exist in a different material or in a material with a different doping concentration or in a different device geometry.

36 MATERIALS SCIENCE↗

Large magnetoelectric resistance in the topological Dirac semimetal α-Sn

The spin-momentum locking of surface states in topological materials can produce a resistance that scales linearly with magnetic and electric fields. Such a bilinear magnetoelectric resistance (BMER) effect offers a new approach for information reading and field sensing applications, but the effects demonstrated so far are too weak or for low temperatures. This article reports the first observation of BMER effects in topological Dirac semimetals; the BMER responses were measured at room temperature and were substantially stronger than those reported previously. The experiments used topological Dirac semimetal α-Sn thin films grown on silicon substrates. The films showed BMER responses that are 10 6 times larger than previously measured at room temperature and are also larger than those previously obtained at low temperatures. These results represent a major advance toward realistic BMER applications. Significantly, the data also yield the first characterization of three-dimensional Fermi-level spin texture of topological surface states in α-Sn.

36 MATERIALS SCIENCE↗

Experimental and Numerical Study on the Effect of Nitric Oxide on Autoignition and Knock in a Direct-Injection Spark-Ignition Engine

We report Nitric Oxide (NO) can significantly influence the autoignition reactivity and this can affect knock limits in conventional stoichiometric SI engines. Previous studies also revealed that the role of NO changes with fuel type. Fuels with high RON (Research Octane Number) and high Octane Sensitivity (S = RON – MON (Motor Octane Number)) exhibited monotonically retarding knocklimited combustion phasing (KL-CA50) with increasing NO. In contrast, for a high-RON, low-S fuel, the addition of NO initially resulted in a strongly retarded KL-CA50 but beyond the certain amount of NO, KL-CA50 advanced again. The current study focuses on same high-RON, low-S Alkylate fuel to better understand the mechanisms responsible for the reversal in the effect of NO on KLCA50 beyond a certain amount of NO. Experiments were conducted to measure the responses of KL-CA50 and trace-autoignition CA50, the latter being indicative of CA50 at which end-gas autoignition starts to become measurable from the apparent heat-release rate. Chemical-kinetics simulations were conducted to reveal the role of NO for end-gas autoignition, with a specific focus on sequential autoignition in a thermally stratified end-gas. The simulation results reveal that the magnitude of low-temperature heat release (LTHR) generally increases with NO. However, the relative importance of NO for enhancing LTHR diminishes when the LTHR inherent to a fuel’s chemistry is strong, such as at lower temperatures in a thermal boundary layer. This rendered more uniform LTHR within a hypothetical thermal boundary and led to a more sequential (i.e. slower) autoignition event. It was also revealed that a change in compression ratio influences the importance of intermediate-temperature heat release (ITHR) due to changes of the temperature-pressure history of the end-gas. Together with the condition where end-gas autoignition occurs more sequentially, the shorter time spent in LTHR and ITHR regime can counter the increase in autoignition reactivity at high NO levels and allow KLCA50 to advance

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

IER-484 CED3b Report: AFRRI ER1 Dosimetry Characterization

This report presents the preliminary work for IER 484, the characterization of the leakage radia tion field from the TRIGA reactor at the Armed Forces Radiobiology Research Institute (AFRRI). The purpose of the dose characterization is to establish the reference dose needed to execute a NAD inter-comparison exercise. During the week of August 20th, a team from Lawrence Livermore National Laboratory (LLNL), Sandia National Laboratory (SNL), and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) performed various measurements in AFRRI’s TRIGA ER1 (Exposure Room 1) with Passive Neutron Spectrometer (PNS) spheres and nuclear accident dosimeters (NADs) mounted on Bottle Manikin Absorption (BOMAB) phantoms (to simulate doses received by people) and additional NADs mounted on aluminum plates (to simulate doses in free air). Without Atomic Weapons Establishment (AWE), LLNL became responsible for measuring the neutron spectrum using PNS spheres. SNL is responsible for providing photon dose data. LLNL, SNL, and IRSN each deployed their own NADs, which will be compared to the reference dose measured. Final characterization of the dose field based on analyzed data will be presented in the CED4a report.

42 ENGINEERING↗

A large area 100-channel PICOSEC Micromegas detector with time resolution at the 20 ps level

Abstract The PICOSEC Micromegas precise timing detector is based on a Cherenkov radiator coupled to a photocathode operating in a semi-transparent mode and a Micromegas amplification structure. The first proof of concept single-channel prototype was able to achieve a time resolution below 25 ps. One of the crucial aspects in the development of precise timing gaseous detectors applicable in high-energy physics experiments is a modular design that enables large area coverage. The first 19-channel multi-pad prototype with an active area of approximately 10 cm 2 suffered from degraded timing resolution due to the non-uniformity of the preamplification gap thickness. A new 100 cm 2 detector module with 100 channels based on a rigid hybrid ceramic/FR4 Micromegas board for improved drift gap uniformity was developed. Initial measurements with 80 GeV/c muons showed improvements in timing response over the measured pads and a time resolution below 25 ps. More recent measurements with a thinner drift gap detector module and newly developed RF pulse amplifiers show that the pad centre resolution can be enhanced to the level of 17 ps. This work will present the development of the detector from structural simulations, design, and beam test commissioning with a focus on the timing performance of a thinner drift gap detector module in combination with new electronics using an automated timing scan method.

Utrobicic, A.↗

Power Electronics Based Self-Monitoring and Diagnosing for Photovoltaics Systems

Self-monitoring and diagnosing technology for photovoltaic (PV) systems is a method to reduce energy production losses. The proposed technology will enable existing panel-level power optimizers and inverters in a PV system to actively perturb the system, measure its response to these small-signal perturbations, and detect any changes in the small-signal impedances. Impedance measurement will be used to identify specific faults and power degradation trends in a PV panel. This information can be used to instantly alert Operations and Maintenance (O&M) personnel of the need for corrective action, thereby reducing energy production losses earlier relative to standard PV systems.

Panchal, Jeet↗

Multi-objective surrogate-assisted calibration of CPFEM models using macroscopic response and in situ EBSD measurements of grain reorientation trajectories

Crystal plasticity finite element method (CPFEM) models are widely used to simulate the deformation behaviour of polycrystalline materials, but their calibration is often limited by their high computational cost and the non-convexity of the optimisation landscape. Here, this study develops a multi-objective surrogate-assisted calibration workflow that couples a multi-objective genetic algorithm (MOGA) with an adaptively trained deep neural network (DNN) surrogate model to efficiently identify CPFEM parameters from experimental data. The workflow is demonstrated on three crystal plasticity (CP) formulations of increasing complexity — Voce hardening (VH), two-coefficient latent hardening (LH2), and six-coefficient latent hardening (LH6) — using in situ electron backscatter diffraction (EBSD) measurements of Alloy 617 under uniaxial tensile loading. The CPFEM models are calibrated against the experimentally observed stress–strain response and reorientation trajectories of eight grains, then validated against eight additional trajectories and overall texture evolution. Across the CP formulations, the macroscopic response was reproduced reliably, while differences emerged in the robustness and accuracy of the grain-scale predictions. Including grain reorientation trajectories in the multi-objective calibration improved texture evolution predictions and filtered out physically inconsistent parameter sets that can arise from calibrating against only the stress–strain data. The workflow also demonstrates good transferability of calibrated parameters from a low- to a high-fidelity microstructural model. These results provide practical guidance for integrating in situ microstructural data into CPFEM through efficient, repeatable, and physically meaningful multi-objective calibration.

Crystal plasticity finite element method↗

Attosecond response of molecules to impulsive ionization

When matter interacts with energetic radiation it can undergo sudden, or impulsive, ionization. This process can drive chemical change and occurs widely in space and planetary atmospheres, yet its comprehensive description challenges our current theoretical and computational capabilities as it requires advanced treatment of electron correlation and nonadiabatic dynamics beyond the Born–Oppenheimer approximation. Here, in this study, we measure the response of the para-aminophenol molecule to sudden ionization. Using attosecond X-ray absorption spectroscopy, we resolve the ultrafast dynamics of the ionized molecule with atomic precision. A subfemtosecond decay corresponds to states undergoing non-radiative decay, whereas few-femtosecond oscillatory signatures are associated with electronic wavepacket motion in stable cation states that later couple to nuclear motion. We compare our measurement with state-of-the-art computational modelling, qualitatively reproducing the observed response across multiple timescales. These results provide a benchmark for computational models of sudden ionization and ultrafast charge motion in matter.

Driver, Taran [SLAC National Accelerator Laborator↗

Neutron Leakage Spectra of the EUCLID Experiment [Abstract]

Integral experiments with sub-critical and critical configurations of special nuclear material are performed in support of nuclear data validation and adjustment. Different nuclear data evaluations may have different values for individual cross sections due to uncertainties in (or lack of) differential experiments, but compensating errors in these data sets can lead to the same k eff results for one application while vastly different for another application. One example of this is 239 Pu, where both ENDF/B-VIII.0 and JEFF-3.3 correctly compute k eff of the Jezebel critical assembly, but the individual contributions from each reaction are vastly different. To help resolve this specific case, the Experiments Underpinned by Computational Learning for Improvements in Nuclear Data (EUCLID) project used machine learning to design a set of experiments to help resolve the compensating errors in 239 Pu. A total of six responses were measured during the experimental campaign, which constrain the data in ways that k eff alone cannot and will be used for adjustment of the nuclear data. One of these responses is the neutron leakage spectrum, which recent work has shown to be useful for constraining the prompt fission neutron spectrum and inelastic scattering. The neutron leakage spectra were measured utilizing a 3 in. right cylinder EJ-301D detector. The measured signal in the detector was deconvoluted using spectrum unfolding techniques, which are presented and compared to simulations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distribution of the Spectral Response of Cells in Silicon Modules - Mechanisms and Implications

Measurements of the spectral response of cells in a PV module can provide important insight into the physics of the device and are also needed for the accurate calibration of the performance of these devices using solar simulators. While techniques for measuring the spectral response of PV cells are well established, measurement of the spectral response of all cells in a module is not straightforward since in this case one has electrical access to a string of cells and not to cells individually. Here we present a new approach for testing the spectral response of individual cells in silicon modules that allows for the fast mapping of the response at different locations of the module. We show that in some cases the spectral response of different cells in a module can vary considerably and propose an underlying mechanism for this variation. We also discuss the implications of this observation for the uncertainty of the spectral correction and of the I SC calibration using a solar simulator.

modules↗

Equalization of Intensity-Modulated Fiber-Optic Voltage Sensors for Power Distribution Systems

We test fiber-optic voltage sensors based on optical reflection from a piezoelectric transducer. Our specific devices possess a 2 kHz fundamental resonance, and we verify a readily usable frequency band from approximately 10 Hz to 3 kHz, with a dynamic range of 60 dB for a detection system integrating over this entire band. Additionally, we demonstrate a digital signal processing approach to equalize the measured frequency response, enabling accurate retrieval of short-pulse inputs. These results suggest the value and applicability of intensity-modulated fiber-optic voltage sensors for measuring both steady-state waveforms and broadband transients which, coupled with the straightforward and compact design of the sensors, should make them effective tools in electric grid monitoring.

42 ENGINEERING↗

Calibration and Data Analysis of a Frequency Selectable Laser Source for CMB Detector Characterization

Cosmic Microwave Background (CMB) experiments study faint radiation left over from the early universe. The CMB was created when the universe became cool enough for light to travel freely through space, and today it gives scientists one of the earliest images of the universe. One important goal of modern CMB experiments is to measure this radiation with higher precision in order to search for evidence that supports the theory of cosmic inflation. To do this, scientists use extremely sensitive detectors that must be calibrated accurately. The Frequency Selectable Laser Source, or FLS, is a new calibration tool that can send selected frequencies to detectors and help measure their response. During my internship, I worked on the FLS after it returned to Fermilab from Chile, where it had been used to characterize detectors at the Simons Observatory. The system came back in parts, so the first part of my project was helping rebuild the optical and mechanical setup. After the system was rebuilt, we performed alignments to maximize the receiver photocurrent. We then collected calibration measurements over different frequency ranges, including 543 GHz to 568 GHz, 740 GHz to 766 GHz, and 60 GHz to 500 GHz. These measurements were used to check waterline calibration and reflectivity features and compare new data with previous data. Another major part of my project was learning Python so I could understand previous analysis code, modify it for new files, and write my own code to compare the mean response between datasets. The results showed that the new data was close to previous measurements and that waterline features near 556 GHz and 752 GHz were found within less than 1.5 GHz of the expected values. I also completed the reflectivity analysis for five prisms in two polarization orientations. In the original orientation, the results were consistent between the five prisms and close to values measured on a different system at the University of Chicago. I then collected a second set of measurements on my own with the polarization of the laser rotated by 90 degrees and compared them with the original data using the same Python workflow. The measured reflectivity increased for all five prisms in the new orientation, showing that the prism reflectivity depends on polarization. Future work will focus on using the FLS to characterize real CMB detectors.

Pumarino, Rafael [Unlisted]↗