Search NASA⌕ Search

SEARCH · Search NASA

Results for “Measurement Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

A fast, accurate, and automatic 2D-3D image registration for image-guided cranial radiosurgery

The authors developed a fast and accurate two-dimensional (2D)-three-dimensional (3D) image registration method to perform precise initial patient setup and frequent detection and correction for patient movement during image-guided cranial radiosurgery treatment. In this method, an approximate geometric relationship is first established to decompose a 3D rigid transformation in the 3D patient coordinate into in-plane transformations and out-of-plane rotations in two orthogonal 2D projections. Digitally reconstructed radiographs are generated offline from a preoperative computed tomography volume prior to treatment and used as the reference for patient position. A multiphase framework is designed to register the digitally reconstructed radiographs with the x-ray images periodically acquired during patient setup and treatment. The registration in each projection is performed independently; the results in the two projections are then combined and converted to a 3D rigid transformation by 2D-3D geometric backprojection. The in-plane transformation and the out-of-plane rotation are estimated using different search methods, including multiresolution matching, steepest descent minimization, and one-dimensional search. Two similarity measures, optimized pattern intensity and sum of squared difference, are applied at different registration phases to optimize accuracy and computation speed. Various experiments on an anthropomorphic head-and-neck phantom showed that, using fiducial registration as a gold standard, the registration errors were 0.33{+-}0.16 mm (s.d.) in overall translation and 0.29 deg. {+-}0.11 deg. (s.d.) in overall rotation. The total targeting errors were 0.34{+-}0.16 mm (s.d.), 0.40{+-}0.2 mm (s.d.), and 0.51{+-}0.26 mm (s.d.) for the targets at the distances of 2, 6, and 10 cm from the rotation center, respectively. The computation time was less than 3 s on a computer with an Intel Pentium 3.0 GHz dual processor.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-BRD-10: An Evaluation of Three Robust Optimization Approaches in IMPT Treatment Planning

Purpose: Various robust optimization approaches have been proposed to ensure the robustness of intensity modulated proton therapy (IMPT) in the face of uncertainty. In this study, we aim to investigate the performance of three classes of robust optimization approaches regarding plan optimality and robustness. Methods: Three robust optimization models were implemented in our in-house IMPT treatment planning system: 1) L2 optimization based on worst-case dose; 2) L2 optimization based on minmax objective; and 3) L1 optimization with constraints on all uncertain doses. The first model was solved by a L-BFGS algorithm; the second was solved by a gradient projection algorithm; and the third was solved by an interior point method. One nominal scenario and eight maximum uncertainty scenarios (proton range over and under 3.5%, and setup error of 5 mm for x, y, z directions) were considered in optimization. Dosimetric measurements of optimized plans from the three approaches were compared for four prostate cancer patients retrospectively selected at our institution. Results: For the nominal scenario, all three optimization approaches yielded the same coverage to the clinical treatment volume (CTV) and the L2 worst-case approach demonstrated better rectum and bladder sparing than others. For the uncertainty scenarios, the L1 approach resulted in the most robust CTV coverage against uncertainties, while the plans from L2 worst-case were less robust than others. In addition, we observed that the number of scanning spots with positive MUs from the L2 approaches was approximately twice as many as that from the L1 approach. This indicates that L1 optimization may lead to more efficient IMPT delivery. Conclusion: Our study indicated that the L1 approach best conserved the target coverage in the face of uncertainty but its resulting OAR sparing was slightly inferior to other two approaches.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-T-04: Implementation of a Standardized Monthly Quality Check for Linac Output Management in a Large Multi-Site Clinic

Purpose: This work is to investigate the feasibility of a standardized monthly quality check (QC) of LINAC output determination in a multi-site, multi-LINAC institution. The QC was developed to determine individual LINAC output using the same optimized measurement setup and a constant calibration factor for all machines across the institution. Methods: The QA data over 4 years of 7 Varian machines over four sites, were analyzed. The monthly output constancy checks were performed using a fixed source-to-chamber-distance (SCD), with no couch position adjustment throughout the measurement cycle for all the photon energies: 6 and 18MV, and electron energies: 6, 9, 12, 16 and 20 MeV. The constant monthly output calibration factor (Nconst) was determined by averaging the machines’ output data, acquired with the same monthly ion chamber. If a different monthly ion chamber was used, Nconst was then re-normalized to consider its different NDW,Co-60. Here, the possible changes of Nconst over 4 years have been tracked, and the precision of output results based on this standardized monthly QA program relative to the TG-51 calibration for each machine was calculated. Any outlier of the group was investigated. Results: The possible changes of Nconst varied between 0–0.9% over 4 years. The normalization of absorbed-dose-to-water calibration factors corrects for up to 3.3% variations of different monthly QA chambers. The LINAC output precision based on this standardized monthly QC relative to the TG-51 output calibration is within 1% for 6MV photon energy and 2% for 18MV and all the electron energies. A human error in one TG-51 report was found through a close scrutiny of outlier data. Conclusion: This standardized QC allows for a reasonably simplified, precise and robust monthly LINAC output constancy check, with the increased sensitivity needed to detect possible human errors and machine problems.

60 APPLIED LIFE SCIENCES↗

NMR dynamics of quantum discord for spin-carrying gas molecules in a closed nanopore

A local orthogonal transformation that transforms any centrosymmetric density matrix of a two-qubit system to the X form has been found. A piecewise-analytic-numerical formula Q = min{Q_π_/_2, Q_θ, Q_0}, where Q{sub π/2} and Q{sub 0} are analytical expressions and the branch Q{sub 0θ} can be obtained only by numerically searching for the optimal measurement angle θ ∈ (0, π/2), is proposed to calculate the quantum discord Q of a general X state. The developed approaches have been applied for a quantitative description of the recently predicted flickering (periodic disappearance and reappearance) of the quantum-information pair correlation between nuclear 1/2 spins of atoms or molecules of a gas (for example, {sup 129}Xe) in a bounded volume in the presence of a strong magnetic field.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Quantitative description of the properties of extended defects in silicon by means of electron- and laser-beam-induced currents

A solar cell on a wafer of multicrystalline silicon containing grain boundaries was studied by the induced-current method. The sample was scanned by an electron beam and by a laser beam at two wavelengths (980 and 635 nm). The recorded induced-current maps were aligned by means of a specially developed code, that enabled to analyze the same part of the grain boundary for three types of measurements. Optimization of the residual between simulated induced-current profiles and those obtained experimentally yielded quantitative estimates of the characteristics of a sample and its defects: the diffusion length of minority carriers and recombination velocity at the grain boundary.

36 MATERIALS SCIENCE↗

Determination of free 25(OH)D concentrations and their relationships to total 25(OH)D in multiple clinical populations

Context The optimal measure of vitamin D status is unknown. Objective To directly measure circulating free 25-hydroxyvitamin D [25(OH)D] concentrations and relationships to total 25(OH)D in a clinically diverse sample of humans. Design Cross-sectional analysis. Setting Seven academic sites. Patients A total of 1661 adults: healthy (n = 279), prediabetic (n = 479), outpatients (n = 714), cirrhotic (n = 90), pregnant (n = 20), nursing home resident (n = 79). Interventions Merge research data on circulating free 25(OH)D (directly-measured immunoassay), total 25(OH)D (liquid chromatography/tandem mass spectrometry), D-binding protein [DBP; by radial (polyclonal) immunodiffusion assay], albumin, creatinine, intact parathyroid hormone, and DBP haplotype. Main outcome measures Distribution of free 25(OH)D (ANOVA with Bonferroni correction for post hoc comparisons) and relationships between free and total 25(OH)D (mixed-effects modeling incorporating clinical condition, DBP haplotype with sex, race, estimated glomerular filtration rate (eGFR), body mass index (BMI), and other covariates). Results Free 25(OH)D was 4.7 ± 1.8 pg/mL (mean ± SD) in healthy persons and 4.3 ± 1.9 pg/mL in outpatients, with levels of 0.5 to 8.1 pg/mL and 0.9 to 8.1 pg/mL encompassing 95% of healthy persons and outpatients, respectively. Free 25(OH)D was higher in patients with cirrhosis (7.1 ± 3.0 pg/mL; P < 0.0033) and nursing home residents (7.9 ± 2.1 pg/mL; P < 0.0033) than in other groups and differed between whites and blacks (P < 0.0033) and between DBP haplotypes (P < 0.0001). Mixed-effects modeling of relationships between free and total 25(OH)D identified clinical conditions (patients with cirrhosis > nursing home residents > patients with prediabetes > outpatients > pregnant women) and BMI (lesser effect) as covariates affecting relationships but not eGFR, sex, race, or DBP haplotype. Conclusions Total 25(OH)D, health condition, race, and DBP haplotype affected free 25(OH)D, but only health conditions and BMI affected relationships between total and free 25(OH)D. Clinical importance of free 25(OH)D needs to be established in studies assessing outcomes.

Schwartz, Janice B.↗

Los Alamos Air Monitoring Data Related to the Fukushima Daiichi Reactor

In response to the disasters in Japan on March 11, 2011, Los Alamos National Laboratory (LANL) is collecting air data and analyzing the data for fission products. At present, we report preliminary data from three high-volume air samplers and one stack sampler. Iodine-131 (I-131) is not optimally measured by our standard polypropylene filters. In addition to the filter data, we have one measurement obtained from a charcoal cartridge. These data, together with measurements of other radionuclides are adequate for a preliminary assessment and assure us that radionuclides from Fukushima Daiichi do not present a threat to human health at or near Los Alamos.

AIR↗

Metaproteomics Identifies the Protein Machinery Involved in Metal and Radionuclide Reduction in Subsurface Microbiomes and Elucidates Mechanisms and U(VI) Reduction Immobilization

The overall goal for this funded project was to develop and exploit environmental metaproteomics tools to identify biomarkers for monitoring microbial activity affecting U speciation at U-contaminated sites, correlate metaproteomics profiles with geochemical parameters and U(VI) reduction activity (or lack thereof), elucidate mechanisms contributing to U(VI) reduction, and provide remediation project managers with additional information to make science-based site management decisions for achieving cleanup goals more efficiently. Although significant progress has been made in elucidating the microbiology contribution to metal and radionuclide reduction, the cellular components, pathway(s), and mechanisms involved in U trans-formation remain poorly understood. Recent advances in (meta)proteomics technology enable detailed studies of complex samples, including environmental samples, which differ between sites and even show considerable variability within the same site (e.g., the Oak Ridge IFRC site). Additionally, site-specific geochemical conditions affect microbial activity and function, suggesting generalized assessment and interpretations may not suffice. This research effort integrated current understanding of the microbiology and biochemistry of U(VI) reduction and capitalize on advances in proteomics technology made over the past few years. Field-related analyses used Oak Ridge IFRC field ground water samples from locations where slow-release substrate biostimulation has been implemented to accelerate in situ U(VI) reduction rates. Our overarching hypothesis was that the metabolic signature in environmental samples, as deciphered by the metaproteome measurements, would show a relationship with U(VI) reduction activity. Since metaproteomic and metagenomic characterizations were computationally challenging and time-consuming, we used a tiered approach that combines database mining, controlled laboratory studies, U(VI) reduction activity measurements, phylogenetic analyses, and gene expression studies to support the metaproteomics characterizations. Growth experiments of target microorganisms (Anaeromyxobacter, Shewanella, Geobacter) revealed tremendous respiratory versatility, as evidenced by the ability to utilize a range of electron donors (e.g. acetate, hydrogen, pyruvate, lactate, succinate, formate) and electron acceptors (e.g. nitrate, fumarate, halogenated phenols, ferric iron, nitrous oxide, etc.). In particular, the dissimilatory metabolic reduction of metals, including radionuclides, by target microorganisms spurred interest for in situ bioremediation of contaminated soils and sediments. Distinct c-type cytochrome expression patterns were observed in target microorganisms grown with the different electron acceptors. For each target microorganism, the core proteome covered almost all metabolic pathways represented by their corresponding pan-proteomes. Unique proteins were detected for each target microorganism, and their expression and possible functionalities were linked to specific growth conditions through proteomics measurements. Optimization of the proteomic tools included in-depth comprehensive metagenomic and metaproteomic analyses on a limited number of samples. The optimized metaproteomic analyses were then applied to Oak Ridge IFRC field samples from the slow-release substrate biostimulation. Metaproteomic analysis and pathway mapping results demonstrated the distinct effects of metal and non-metal growth conditions on the proteome expression. With these metaproteomic tools, we identified which previously hypothetical metabolic pathways were active during the analyzed time points of the slow release substrate biostimulation. Thus, we demonstrated the utility of these tools for site assessment, efficient implementation of bioremediation and long-term monitoring. This research of detailed protein analysis linked with metal reduction activity did (1) show that c-type cytochrome isoforms, previously associated with radionuclide reduction activity, are suitable biomarkers, (2) identify new biomarker targets for site assessment and bioremediation monitoring, and (3) provide new information about specific proteins and mechanisms involved in U(VI) reduction and immobilization. This expanded metagenomic and metaproteomic toolbox contributed to implementing science-driven site management with broad benefits to the DOE mission.

54 ENVIRONMENTAL SCIENCES↗

In-Pile Instrumentation Initiative: A Multidisciplinary Scientific Approach for Characterization of Fuels and Materials

The In-Pile Instrumentation Initiative (I3) will conduct research needed to develop and deploy unique instruments to characterize the behavior of fuels and materials during irradiation tests conducted by Nuclear Energy (NE) programs within the Department of Energy. (Vision) I3 will provide real-time, accurate, spatially resolved information regarding performance of fuels and materials that can be directly tied to microstructure. This vision is reflected in the research direction of several NE programs that have identified a need to correlate material performance with evolving microstructure. Currently, these relationships can only be inferred through examination of materials in a post-irradiation environment. Realization of this vision will involve a sharp departure from the current approach that prioritizes instrument reliability over delivering optimal measurement capabilities. To realize this vision will require technical breakthroughs in several key areas, including materials science, modeling and simulation, advanced manufacturing, and instrument development. Insights gained from this initiative will be critical for advancing a number of NE objectives. Examples include expediting the development of accident-tolerant fuels, providing a deep understanding of materials suitable for the extreme environments associated with new reactor technologies, and providing unparalleled validation metrics for new science-based fuel performance codes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase Measurements of a 140-GHz Confocal Gyro-Amplifier

The phase stability of a 140-GHz, 1-kW pulsed gyro-amplifier system and the phase dependence on the cathode voltage were experimentally measured. To optimize the measurement precision, the amplifier was operated at 47 kV and 1 A, where the output power was ~30 W. The phase was determined to be stable both pulse-to-pulse and during each pulse, so far as the cathode voltage and electron beam current are constant. The phase variation with voltage was measured and found to be 130 ± 30 deg/kV, in excellent agreement with simulations. The electron gun used in this device is non-adiabatic, resulting in a steep slope of the beam pitch factor with respect to cathode voltage. This was discovered to be the dominant factor in the phase dependence on voltage. The use of an adiabatic electron gun is predicted to yield a significantly smaller phase sensitivity to voltage, and thus a more phase-stable performance. To our knowledge, these are the first phase measurements reported for a gyro-amplifier operating at a frequency above W-band.

Rosenzweig, Guy↗

Variable-rate optical communication through the turbulent atmosphere

It was demonstrated that the data transmitter can extract real time, channel state information by processing the field received when a pilot tone is sent from the data receiver to the data transmitter. Based on these channel measurements, optimal variable rate techniques were derived and significant improvements in system perforamnce were obtained, particularly at low bit error rates.

Levitt, B. K.↗

High-speed code validation

The topics are presented in viewgraph form and include the following: NFL body experiment; high-speed validation problems; 3-D Euler/Navier-Stokes inlet code; two-strut inlet configuration; pressure contours in two longitudinal planes; sidewall pressure distribution; pressure distribution on strut inner surface; inlet/forebody tests in 60 inch helium tunnel; pressure distributions on elliptical missile; code validations; small scale test apparatus; CARS nonintrusive measurements; optimized cone-derived waverider study; etc.

Barnwell, Richard W.↗

An overview of the Solar, Anomalous, and Magnetospheric Particle Explorer (SAMPEX) mission

The scientific objective of the NASA Small-class Explorer Mission SAMPEX is summarized. A brief history of the Small Explorer program is provided along with a description of the SAMPEX project development and structure. The spacecraft and scientific instrument configuration is presented. The orbit of SAMPEX has an altitude of 520 by 670 km and an 82 deg inclination. Maximum possible power is provided by articulated solar arrays that point continuously toward the sun. Highly sensitive science instruments point generally toward the local zenith, especially over the terrestrial poles, in order to measure optimally the galactic and solar cosmic ray flux. Energetic magnetospheric particle precipitation is monitored at lower geomagnetic latitudes. The spacecraft uses several innovative approaches including an optical fiber bus, powerful onboard computers, and large solid state memories (instead of tape recorders). Spacecraft communication and data acquisition are discussed, and the space- and ground-segment data flows are summarized. A mission lifetime of 3 years is sought with the goal of extending data acquisition over an even longer portion of the 11-year solar activity cycle.

Baker, Daniel N.↗

Thermal Property Parameter Estimation of TPS Materials

Accurate knowledge of the thermophysical properties of TPS (thermal protection system) materials is necessary for pre-flight design and post-flight data analysis. Thermal properties, such as thermal conductivity and the volumetric specific heat, can be estimated from transient temperature measurements using non-linear parameter estimation methods. Property values are derived by minimizing a functional of the differences between measured and calculated temperatures. High temperature thermal response testing of TPS materials is usually done in arc-jet or radiant heating facilities which provide a quasi one-dimensional heating environment. Last year, under the NASA-ASEE-Stanford Fellowship Program, my work focused on developing a radiant heating apparatus. This year, I have worked on increasing the fidelity of the experimental measurements, optimizing the experimental procedures and interpreting the data.

Maddren, Jesse↗

The HYDROS Mission: Requirements and Baseline System Design

The HYDROS mission is under development by NASA as part of its Earth System Science Pathfinder (ESSP) program. HYDROS is designed to provide global maps of the Earth's soil moisture and freezel/thaw state every 2-3 days, for weather and climate prediction, water and carbon cycle studies, natural hazards monitoring, and national security applications. HYDROS uses a unique active and passive L-band microwave system that optimizes measurement accuracy, spatial resolution, and coverage. It provides measurements in nearly all weather conditions, regardless of solar illumination. The designs of the radar and radiometer electronics, antenna feedhorn and reflector, and science data system, are driven by specific mission and science objectives. These objectives impose requirements on the frequencies, polarizations, sampling, spatial resolution, and accuracy of the system. In this paper we describe the HYDROS mission requirements, baseline design, and measurement capabilities.

soil moisture↗