Optimal Approximation of Spectral Risk Measures with Application to PDE-Constrained Optimization.
Abstract not provided.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
Abstract not provided.
The optimized stellarator Wendelstein 7-X (W7-X) is designed to have an approximately quasi-isodynamic magnetic configuration with reduced neoclassical transport in comparison to a classical stellarator, and turbulent transport is expected to be a significant source of anomalous heat transport across the plasma minor radius. The ion temperature gradient driven mode and the trapped electron mode (TEM) are thought to be responsible for the ion-scale turbulence in W7-X plasmas with volume averaged pressure below 1%. In this work, the electron temperature gradient driven turbulence is shown to be a good candidate for the explanation of the observed electron heat flux, in the inner plasma region where the density gradient is weak (in the outer region, a relatively stronger density gradient would drive additional TEM turbulence). Further, the experimental electron heat transport measured during electron cyclotron resonant heating power and plasma density scans is compared to neoclassical predictions, and the stiffness in the electron heat transport measured during transient transport experiments is presented in three common magnetic configurations of W7-X. In low-(β) plasma discharges, the stiffness in the electron heat flux, quantified by the ratio of the heat pulse to power balance diffusivity, ${\chi }_{\mathrm{e}}^{\mathrm{H}\mathrm{P}}/{\chi }_{\mathrm{e}}^{\mathrm{P}\mathrm{B}}$, is measured to be less than 2, and trend downwards with increasing collisionality.
Purpose. To investigate the influence that measurement of balloon volume as a controlled variable in addition to balloon pressure has on the outcome of balloon angioplasty in an experimental model. Methods. One hundred and three segments of explanted normal porcine carotid arteries were obtained. Five were used as controls, and the remaining 98 were subjected to balloon angioplasty with simultaneous measurement of balloon volume and pressure. These arteries were randomized into two groups. In one group the endpoint of the angioplasty was determined by balloon pressure (pressure-limited group, PLG) and in the other group by balloon volume (volume-limited group, VLG). Pressure/volume curves for each procedure were constructed by continuous measurement of both parameters by a purpose-designed computer-controlled inflation device. The diameter of each arterial segment was measured by intravascular ultrasound (IVUS) and the ratio of the inflated balloon to arterial diameter calculated. Arterial appearances after angioplasty were recorded using IVUS. Results. The balloon volumes measured at the endpoint of angioplasty were significantly smaller in the PLG compared with the VLG (p < 0.001). Three types of pressure/volume curves were identified: A, B, and C. In the type A curves, IVUS identified fissures in 28% (17/60) and the examination was normal in 72% (43/60). In the type B curves, IVUS identified fissures in 44% (4/9), dissections in 22% (2/9), and the examination was normal in 33% (3/9). In the type C curves, IVUS identified fissures in 44% (4/9) and dissection in 56% (5/9) with no normal examinations. In undamaged arterial segments a very high correlation was achieved between balloon volume and the balloon/artery ratio (Pearson correlation = -0.979, R{sup 2} = 0.957, p < 0.0001, n = 27). Conclusion. The measurement of pressure and volume during angioplasty enabled the construction of pressure/volume curves that showed deviations from the curves obtained in air. The balloon volume results, and significant deviation of the curve shape from the control curve shape, predicted vessel damage, which was confirmed by the IVUS appearance of the vessel after angioplasty. When pressure was used as the endpoint of balloon inflation the balloons were significantly underdilated compared with the manufacturer's nominal sizes. These data indicate that monitoring of pressure and volume during angioplasty may provide an alternative method of predicting vessel damage.
Not Available
Reconstructing high-resolution flow fields from sparse measurements is a major challenge in fluid dynamics. Existing methods often vectorize the flow by stacking different spatial directions on top of each other, hence confounding the information encoded in different dimensions. Here, we introduce a tensor-based sensor placement and flow reconstruction method which retains and exploits the inherent multidimensionality of the flow. We derive estimates for the flow reconstruction error, storage requirements and computational cost of our method. We show, with examples, that our tensor-based method is significantly more accurate than similar vectorized methods. Furthermore, the variance of the error is smaller when using our tensor-based method. While the computational cost of our method is comparable to similar vectorized methods, it reduces the storage cost by several orders of magnitude. The reduced storage cost becomes even more pronounced as the dimension of the flow increases. We demonstrate the efficacy of our method on three examples: a chaotic Kolmogorov flow, in situ and satellite measurements of the global sea surface temperature and three-dimensional unsteady simulated flow around a marine research vessel.
The Sino-French SVOM mission (Space-based multi-band astronomical Variable Objects Monitor) has been designed to detect all known types of gamma-ray bursts (GRBs) and to provide fast and reliable GRB positions. In this study we present the SVOM pointing strategy which should ensure the largest number of localized bursts allowing a redshift measurement. The redshift measurement can only be performed by large telescopes located on Earth. The best scientific return will be achieved if we are able to combine constraints from both space segment (platform and payload) and ground telescopes (visibility)
The power absorbed by the plasma is one of the key parameters which defines processes in any plasma source. This power, however, can be very different from the power at the rf power source output or the coupler terminals, which has been used in many publications to characterize the plasma. This article describes how to find the power absorbed by the plasma and the power lost in the coupler and matcher network for inductively coupled plasmas. In addition, several practical coupler configurations to reduce the coupler coil loss and minimize the rf plasma potential are discussed. Here, we propose an effective and simple method to achieve that by the coupler coil splitting and insertion of the resonating capacitor in the middle of the coil. Our experimental data demonstrate this approach having superior coupler efficiency and substantially lower rf plasma potential.
Abstract Not Provided
Integrating Lidar to improve wind turbine controls is a potential breakthrough for reducing the cost of wind energy. By providing undisturbed wind measurements up to 400m in front of the rotor, Lidar may provide an accurate update of the turbine inflow with a preview time of several seconds. Focusing on loads, several studies have evaluated potential reductions using integrated Lidar, either by simulation or full scale field testing.
Methods and systems for optimizing a performance of a vehicle engine are provided. The method includes determining an initial value for a first engine control parameter based on one or more detected operating conditions of the vehicle engine, determining a value of an engine performance variable, and artificially perturbing the determined value of the engine performance variable. The initial value for the first engine control parameter is then adjusted based on the perturbed engine performance variable causing the engine performance variable to approach a target engine performance variable. Operation of the vehicle engine is controlled based on the adjusted initial value for the first engine control parameter. These acts are repeated until the engine performance variable approaches the target engine performance variable.
A new coherence imaging spectroscopy (CIS) diagnostic optimized to measure the C 2+ impurity ion temperature T i spatial distribution in the divertor plasma of the W7-X stellarator is designed, tested, and validated. Using CIS to obtain T i in the edge of magnetically confined plasmas has historically been challenging because Doppler broadening and Zeeman splitting have comparable effects on the shape of spectral emission lines. To distinguish between these two mechanisms, a novel approach to birefringent crystal design is employed to minimize the diagnostic’s sensitivity to Zeeman splitting. The recently developed pixelated multi-delay CIS approach is also used to obtain four times as much spectral information as traditional CIS approaches. The T i -optimized CIS diagnostic is validated in a long-pulse W7-X plasma by comparison with a high-resolution spectrometer whose sightlines overlap with the CIS field of view. The CIS and spectrometer T i profiles have the same shape and agree to within 10% on average and 25% in the worst case. Images of the T i distribution near the divertor show toroidally elongated bands aligned with the magnetic field, with T i ranging between 10 and 40 eV.
ABSTRACT We present measurements of the local primordial non-Gaussianity parameter $f_{\mathrm{NL}}^\mathrm{local} $from the clustering of 343 708 quasars with redshifts 0.8 < z < 2.2 distributed over 4808 deg2 from the final data release (DR16) of the extended Baryon Acoustic Oscillation Spectroscopic Survey (eBOSS), the largest volume spectroscopic survey up to date. Our analysis is performed in Fourier space, using the power spectrum monopole at very large scales to constrain the scale-dependent halo bias. We demonstrate the robustness of our analysis pipeline with EZ-mock catalogues that simulate the eBOSS DR16 target selection. We carefully assess the impact of systematics on our measurement, exploiting a novel neural network scheme for cleaning the DR16 sample as well as test multiple contamination removal methods. We estimate the bias due to the overcorrection of the systematic removal to be sub-dominant compared to the statistical uncertainty. We find fNL = −12 ± 21 (68 per cent confidence) for the main clustering sample including quasars with redshifts between 0.8 and 2.2, after applying redshift weighting techniques, designed for non-Gaussianity measurement from large scales structure, to optimize our analysis, which improve our results by 37 per cent.
The slides present a novel convex optimization formulation to compute the best set of measurements for multi-response dynamical systems with asynchronous time steps that maximize the Fisher information content subject to budget constraints. The trace (A-optimality) or determinant (D-optimality) of the Fisher Information Matrix (FIM) quantifies the information content. The framework supports arbitrary (positive semi-definite) variance and covariances between every pair of responses and their time steps.
Experimental measurements are commonly represented on a discrete grid, requiring a balance between granularity and statistical noise. Two strategies have traditionally been used to improve such representations: selecting an appropriate bin width to control discretization error and applying kernel-based smoothing to suppress fluctuations. Despite their shared goal, these approaches have largely developed independently, without a unified statistical description of how discretization and correlation jointly determine measurement precision. Here, we extend the discussion of optimal interval averaging to a correlation-aware setting by Gaussian process regression, which explicitly accounts for correlations among neighboring bins. Starting from first principles, we derive the mean-squared error of discretized measurements and obtain closed-form asymptotic expressions for the optimal bin width and correlation length. When recast in reduced variables, the theory reveals distinct universal scaling laws governing the error in the correlation-free and correlation-controlled regimes. Characterized by intrinsically smooth intensity profiles and counting-based statistics, neutron scattering measurements are well suited for demonstrating the enhanced error contraction enabled by inter-bin correlations. We show that such improvement is achievable over the experimentally accessible Q-range and across multiple instruments and material systems. These results show that explicitly accounting for correlations systematically reshapes the limits of precision in discretized, noise-limited measurements. More broadly, the framework provides a transferable statistical foundation for optimizing data representation, inference, and experimental design across the physical and data sciences.