At least 145 records · Page 8

Critical and Californium Source-Driven Noise Analysis Subcritical Measurements with an Unreflected Cylindrical Tank of Mixed Uranium-Plutonium Nitrate Solution

The reported experiments were performed by Oak Ridge National Laboratory (ORNL) at the Battelle Northwest Laboratory’s (now Pacific Northwest National Laboratory) critical experiments facility at Hanford, Washington in 1981 and used 16 days of critical facility time, not including 10 days for setup and removal of ORNL equipment. These measurements were to assess the capability of the Cf source-driven noise analysis (CSDNA) method to measure the subcriticality (keff) of mixed U-Pu nitrate solutions. In addition to the CSNDA measurements, measurements were also performed near delayed criticality where CSDNA measurements cannot be performed. This report documents the experiments that were not reported at that time by presenting the ORNL experimental results and any online analysis performed during and shortly after the measurements. The mixed nitrate solution had a U concentration at 188 grams per liter (g/L), a Pu concentration of 280 g/L, free acid normality of 2.80, H ion molarity of 5.9 and a specific gravity of 1.754 g/cm 3 , a 240 Pu isotopic content of 7.981 wt. %, and a 235 U isotopic content of 0.724 wt. %. The stainless-steel tank for the solution had an inside diameter of 35.38 cm, an outside diameter of 35.53 cm, a height of 56.72 cm, and bottom thickness of 0.9525 cm. A Zircaloy pipe with a 3.1496 cm outside diameter, a 2.7788 cm inside diameter, and bottom thickness of 0.635 cm was available for insertion of the Cf source in the center of the fissile solution. The Cf source was also located at the outside surface of the tank (solution height varied from 10 to 53 cm) and in the center of the solution (solution height varied from 10 to 60.7 cm). The CSDNA measurements were not analyzed online to determine the subcritical neutron multiplication factors. At all subcritical states, the break frequency noise analysis data was fitted to obtain the prompt neutron decay constant. The neutron multiplication factors were determined for the two configurations of the measurements near delayed criticality. The subcritical neutron multiplication factors from the CNSDA measurements can be obtained with further analysis. However, the near delayed critical configuration, the prompt neutron decay constants, the count rates, and the measured cross and auto power spectral densities can be calculated directly for benchmarking. Much of data presented in this report are from ORNL notes—not in the ORNL logbooks. For the final benchmark analysis, the data from the Battelle Northwest Laboratory (which operated the critical facility in 1981) critical facility logbook should be consulted and be incorporated where appropriate. The purpose of this report is to document the experimental information for the measurements performed so that at a later date researchers could perform the required uncertainty and calculational analyses and documentation to use these data for an International Criticality Safety Benchmark Program (ICSBEP) or Nuclear Energy Agency benchmark. The data from these measurements are available from the ORNL Records Management Services Department, and the logbook is available from ICSBEP at Idaho National Laboratory. Preparation of the present report is part of a larger cooperative effort between Idaho National Laboratory (INL) and Oak Ridge National Laboratory (ORNL) to document more than 15 undocumented critical and subcritical experiments enumerated in ORNL/TM-2019/18 and performed by ORNL at ORCEF and other USDOE critical experiments facilities using more than 500 operational days of critical facility time.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A novel method for thermal noise reduction, enabling measurements of broadband, low-amplitude electron temperature fluctuations using individual radiometer channels

A new analysis method has been developed for measurements of broadband, low-amplitude turbulent electron temperature fluctuations in fusion plasmas using individual radiometer channels of a correlation electron cyclotron emission diagnostic. This method takes advantage of differences in the correlation time of thermal noise compared to the correlation time of plasma fluctuations in fusion reactors. The validation of this single-channel method is demonstrated using comparisons with the standard dual-channel radiometer spectral decorrelation method for measurements of turbulent electron temperature fluctuations in the core and edge of low confinement (L), improved confinement (I), and high confinement (H)-mode plasmas at the ASDEX Upgrade tokamak.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating Eigenenergies from Quantum Dynamics: A Unified Noise-Resilient Measurement-Driven Approach

Ground state energy estimation in physical, chemical, and materials sciences is one of the most promising applications of quantum computing. In this work, we introduce a new hybrid approach that finds the eigenenergies by collecting real-time measurements and post-processing them using the machinery of dynamic mode decomposition (DMD). From the perspective of quantum dynamics, we establish that our approach can be formally understood as a stable variational method on the function space of observables available from a quantum many-body system. We also provide strong theoretical and numerical evidence that our method converges rapidly even in the presence of a large degree of perturbative noise, and show that the method bears an isomorphism to robust matrix factorization methods developed independently across various scientific communities. Our numerical benchmarks on spin and molecular systems demonstrate an accelerated convergence and a favorable resource reduction over state-of-the-art algorithms. The DMD-centric strategy can systematically mitigate noise and stands out as a leading hybrid quantum-classical eigensolver.

Shen, Yizhi↗

Low energy backgrounds and excess noise in a two-channel low-threshold calorimeter

Here, we describe observations of low energy excess (LEE) events, background events observed in all light dark matter direct detection calorimeters, and noise in a transition edge sensor based two-channel silicon athermal phonon detector with 375 meV baseline energy resolution. We measure two distinct LEE populations: “shared” multichannel events with a pulse shape consistent with substrate athermal phonon events and sub-eV events that couple nearly exclusively to a single channel with a significantly faster pulse shape. These “singles” are consistent with events occurring within the aluminum athermal phonon collection fins. Similarly, our measured detector noise is higher than the theoretical expectation. Measured noise can be split into an uncorrelated component, consistent with shot noise from small energy depositions within the athermal phonon sensor itself, and a correlated component, consistent with shot noise from energy depositions within the silicon substrate's phonon system.

47 OTHER INSTRUMENTATION↗

Cryogenic probe for low-noise, high-frequency electronic measurements

The design and performance of a low-noise, modular cryogenic probe, which is applicable to a wide range of measurements over a broad range of working frequencies, temperatures, and magnetic fields, is presented. The design of the probe facilitates the exchange of sample holders and sample-stage amplifiers, which, combined with its characteristic low transmission and reflection loss, make this design suitable for high precision or low sensitivity measurements. The specific example of measuring the shot noise of magnetic tunnel junctions is discussed. We highlight various design characteristics chosen specifically to expand the applicability of the probe to measurement techniques such as nuclear magnetic resonance.

47 OTHER INSTRUMENTATION↗

Joint velocity and density reconstruction of the Universe with nonlinear differentiable forward modeling

Reconstructing the initial conditions of the Universe from late-time observations has the potential to optimally extract cosmological information. Due to the high dimensionality of the parameter space, a differentiable forward model is needed for convergence, and recent advances have made it possible to perform reconstruction with nonlinear models based on galaxy (or halo) positions. In addition to positions, future surveys will provide measurements of galaxies' peculiar velocities through the kinematic Sunyaev-Zel'dovich effect (kSZ), type Ia supernovae, the fundamental plane relation, and the Tully-Fisher relation. Here we develop the formalism for including halo velocities, in addition to halo positions, to enhance the reconstruction of the initial conditions. We show that using velocity information can significantly improve the reconstruction accuracy compared to using only the halo density field. Here we study this improvement as a function of shot noise, velocity measurement noise, and angle to the line of sight. We also show how halo velocity data can be used to improve the reconstruction of the final nonlinear matter overdensity and velocity fields. We have built our pipeline into the differentiable Particle-Mesh FlowPM package, paving the way to perform field-level cosmological inference with joint velocity and density reconstruction. This is especially useful given the increased ability to measure peculiar velocities in the near future.

79 ASTRONOMY AND ASTROPHYSICS↗

A New Crater Near InSight: Implications for Seismic Impact Detectability on Mars

A new 1.5 m diameter impact crater was discovered on Mars only ~40 km from the InSight lander. Context camera images constrained its formation between 21 February and 6 April 2019; follow-up High Resolution Imaging Science Experiment images resolved the crater. During this time period, three seismic events were identified in InSight data. In this paper, we derive expected seismic signal characteristics and use them to evaluate each of the seismic events. However, none of them can definitively be associated with this source. Atmospheric perturbations are generally expected to be generated during impacts; however, in this case, no signal could be identified as related to the known impact. Using scaling relationships based on the terrestrial and lunar analogs and numerical modeling, we predict the amplitude, peak frequency, and duration of the seismic signal that would have emanated from this impact. The predicted amplitude falls near the lowest levels of the measured seismometer noise for the predicted frequency. Hence, it is not surprising this impact event was not positively identified in the seismic data. Finding this crater was a lucky event as its formation this close to InSight has a probability of only ~0.2, and the odds of capturing it in before and after images are extremely low. We revisit impact-seismic discriminators in light of real experience with a seismometer on the Martian surface. Using measured noise of the instrument, we revise our previous prediction of seismic impact detections downward, from ~a few to tens, to just ~2 per Earth year, still with an order of magnitude uncertainty.

58 GEOSCIENCES↗

A 24-channel ultra-low-noise preamplifier for dN/dx measurements with drift tube detectors

Cluster counting $(dN/dx)$ is a promising method to enhance particle identification for gaseous detectors, especially in next-generation collider experiments like the FCC-ee, where good $π/K$ separation over a broad momentum range is essential. However, its implementation in large-scale systems has been limited by the challenging requirements for high-resolution signal amplification and readout. This paper presents a 24-channel ultra-low-noise preamplifier board designed for drift tube detectors to enable $dN/dx$ measurements. The three-stage amplification topology employs SiGe transistors and integrates dedicated noise-minimization techniques, achieving a charge gain of 21.11 mV/fC from 0.3 fC to 50 fC, a bandwidth of 542 MHz, and a voltage gain of 47.8 dB. The measured voltage noise density is 0.35 nV/$\sqrt{\textrm{Hz}}$ , surpassing most of the state-of-the-art preamplifiers for gaseous and silicon detectors. Validation tests conducted on the sMDT chambers at the CERN Proton Synchrotron test beam facility demonstrate that the proposed design meets the stringent preamplifier requirements for implementing the $dN/dx$ method in drift-tube detector systems, achieving an equivalent noise charge of 0.14 fC and a signal-to-noise ratio of 73 when operated with a He:iC 4 H 10 (90:10) gas mixture. The design also shows promise for broader application in other gaseous or semiconductor detectors.

Drift tube detector↗

Three-Wave Mixing Kinetic Inductance Traveling-Wave Amplifier with Near-Quantum-Limited Noise Performance

We present a theoretical model and experimental characterization of a microwave kinetic inductance traveling-wave (KIT) amplifier, whose noise performance, measured by a shot-noise tunnel junction (SNTJ), approaches the quantum limit. Biased with a dc current, this amplifier operates in a three-wave mixing fashion, thereby reducing by several orders of magnitude the power of the microwave pump tone and associated parasitic heating compared to conventional four-wave mixing KIT amplifier devices. It consists of a 50 Ω artificial transmission line whose dispersion allows for a controlled amplification bandwidth. We measure $16.5^{+1}_{–1.3}$ dB of gain across a 2 GHz bandwidth with an input 1 dB compression power of –63 dBm, in qualitative agreement with theory. Using a theoretical framework that accounts for the SNTJ-generated noise entering both the signal and idler ports of the KIT amplifier, we measure the system-added noise of an amplification chain that integrates the KIT amplifier as the first amplifier. This system-added noise, 3.1 ± 0.6 quanta (equivalent to 0.66 ± 0.15 K) between 3.5 and 5.5 GHz, is the one that a device replacing the SNTJ in that chain would see. This KIT amplifier is therefore suitable to read large arrays of microwave kinetic inductance detectors and promising for multiplexed superconducting qubit readout.

42 ENGINEERING↗

Welch Method and Bootstrapping Applied to Subcritical Gamma Noise

We measured the prompt neutron decay constant 𝛼 of the CROCUS zero-power reactor at the Swiss Federal Institute of Technology Lausanne using cross-power spectral density (CPSD) analysis of gamma-gamma correlations from two trans-stilbene organic scintillators positioned near the reactor core. We measured critical and subcritical states, with water levels ranging from 960 mm (critical) to 800 mm (𝜌=−1.4 $ subcritical). Our analysis used the Welch method, dividing signal segments for fast Fourier transform (FFT) frequency analysis and applying bootstrapping uncertainty quantification that uses Welch-defined segments. Results demonstrated a clear increase in the measured 𝛼 as reactor reactivity decreased, distinguishing critical from subcritical conditions. At the 960-mm critical level, 𝛼 was estimated at 155.9 ± 0.7 s −1 , and for the 800-mm subcritical level, 𝛼 increased significantly to 367.3 ± 6.9 s –1 . A linear regression of subcritical states yielded a critical estimate of 154.0 ± 3.1 s –1 , aligning with the static 𝛼 estimate at critical. The bootstrapping method produced normally distributed 𝛼 estimates, confirming data consistency. The gamma CPSD 𝛼 estimates clearly distinguish reactor states and improve monitoring of zero-power reactors. The future deployment of modular and microreactors as potential candidates for noise analysis is demonstrated in CROCUS, particularly zero-power mock-ups of new designs. The improvement of noise analysis in the subcritical domain from this work will support experimental data for reactor deployment and procedure.

CROCUS↗

Scalable quantum processor noise characterization

Measurement fidelity matrices (MFMs) (also called error kernels) are a natural way to characterize state preparation and measurement errors in near-term quantum hardware. They can be employed in post processing to mitigate errors and substantially increase the effective accuracy of quantum hardware. However, the feasibility of using MFMs is currently limited as the experimental cost of determining the MFM for a device grows exponentially with the number of qubits. In this work we present a scalable way to construct approximate MFMs for many-qubit devices based on cumulant expansions. Our method can also be used to characterize various types of correlation error.

Hamilton, Kathleen↗

Spurious solar-wind effects on acceleration noise in LISA Pathfinder

Spurious solar-wind effects are a potential noise source in future Laser Interferometer Space Antenna (LISA) measurements. One noise coupling mechanism is constrained by estimating solar-wind effects on acceleration noise in LISA Pathfinder (LPF). While LISA is designed for drag-free differential measurement, predicting the realistic impact both bounds the operational environment and assesses whether LISA could provide serendipitous space-weather observations. Data from NASA's Advanced Composition Explorer (ACE), situated at the L1 Lagrange point, serves as a reliable source of solar-wind data. The data sets are compared over the 114 d time period from 1 March 2016 to 23 June 2016. This period gives the longest readily-available open data set, without interference from other commissioning activities. To evaluate space weather effects, the data from both satellites are formatted, gap-filled/interpolated, and fast-Fourier transformed for amplitude spectral density and coherence comparisons. Solar wind effects are not seen in a coherence plot between LPF and ACE; modest coherence in the planned LISA observational frequency band can be attributed to chance. This result indicates that measurable correlation due to solar-wind acceleration noise over 3 month timescales will be a negligible noise source. LISA is unlikely to inform solar wind measurements routinely. Another source of noise from the Sun, solar radiation pressure, is estimated to impart greater acceleration noise, but has yet to be analyzed.

79 ASTRONOMY AND ASTROPHYSICS↗

Characterization of Aliased Noise in the Advanced ACTPol Receiver

Advanced ACTPol is the second-generation polarization-sensitive upgrade to the 6m aperture Atacama Cosmology Telescope (ACT), which increased detector count and frequency coverage compared to the previous ACTPol receiver. Advanced ACTPol utilizes a new two-stage time-division multiplexing readout architecture based on superconducting quantum interference devices to achieve a multiplexing factor as high as 64 (rows), fielding a 2012 detector camera at 150/220 GHz and two 90/150 GHz cameras containing 1716 detectors each. In a time-domain system, aliasing introduces noise to the readout. Here in this work we present a figure of merit to measure this noise contribution and present measurements of the aliased noise fraction of the Advanced ACTPol receiver as deployed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A probability density function model describing height estimation uncertainty due to image pixel intensity noise in digital fringe projection measurements

Digital fringe projection is a surface-profiling technique used for highly accurate non-contact measurements. As with any measurement technique, a variety of sources degrade to the measurement accuracy of the method. Here, this paper presents an analytically-derived probability density function that explicitly models the surface height measurement error due to inevitable phase measurement error, and it includes the specific case of pixel noise inducing the phase measurement error that ultimately leads to the height estimation error. The accuracy of the model was validated through Monte-Carlo simulations of resultant height distributions subject to arbitrarily correlated pixel intensity noise and experimental digital fringe projection measurements where the pixel-by-pixel height uncertainty estimations were compared to the predictions of the derived model.

42 ENGINEERING↗

Measurement of correlated charge noise in superconducting qubits at an underground facility

The charge environment of superconducting qubits may be studied through the introduction of controlled, quantified amounts of ionizing radiation. We measure space- and time-correlated charge jumps on a four-qubit device, operating 107 meters below the Earth’s surface in a low-radiation, cryogenic facility designed for the characterization of low-threshold particle detectors. The rock overburden of this facility reduces the cosmic ray muon flux by over 99% compared to laboratories at sea level. Combined with 4π coverage of a movable lead shield, this facility enables quantifiable control over the flux of ionizing radiation on the qubit device. Long-time-series charge tomography measurements on these weakly charge-sensitive qubits capture discontinuous jumps in the induced charge on the qubit islands, corresponding to the interaction of ionizing radiation with the qubit substrate. The rate of these charge jumps scales with the flux of ionizing radiation on the qubit package, as characterized by a series of independent measurements on another energy-resolving detector operating simultaneously in the same cryostat with the qubits. Using lead shielding, we achieve a minimum charge jump rate of $0.19^{+0.04}_{-0.03}$ mHz, almost an order of magnitude lower than that measured in surface tests, but a factor of roughly seven higher than expected based on reduction of ambient gammas alone. We operate four qubits for over 22 consecutive hours with zero correlated charge jumps at length scales above three millimeters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

2020 State of the Science Report, Chapter 4: Risk to Marine Animals from Underwater Noise Generated by Marine Renewable Energy Devices

In all ocean environments, desirable locations for wave and tidal energy development have multiple natural sources of sound (e.g., waves, wind, and sediment transport), varying levels of anthropogenic and biological noise, and measurement quality challenges (e.g., flow-noise, self-noise). Many marine animals rely on sound for biological functions, including communication, social interaction, orientation, foraging, and evasion. The extent to which marine animals detect and produce sound varies by frequency (spanning roughly four decades from 10 Hz to 100 kHz) and is taxa-specific. Because of the relatively limited data available, hearing sensitivity is often generalized to taxonomic groups (e.g., cetaceans that have low-frequency hearing specialization). https://tethys.pnnl.gov/publications/state-of-the-science-2020-chapter-4-underwater-noise