Search NASA⌕ Search

SEARCH · Search NASA

Results for “Mechanical Loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 145 records · Page 8

In-Space Loads Analysis of SLS/Orion

The Space Launch System and Orion spacecraft experience unique load cases during upper stage flight since the Orion must deploy its solar arrays before the upper stage engine fires. The low frequency bending modes of the deployed arrays have the potential to interact with the slosh modes of the upper stage. In combination with the upper stage flight steady-state accelerations this can induce high loads in the array mechanisms. A time-domain transient response solution is used to evaluate the array mechanism loads, sensitivities are noted, and the final loads are determined to be within the capability of the mechanism. Section loads and accelerations are also recovered and assessed.

SLS↗

A concurrent irradiation-mechanics multiscale coupling model

The vast majority of our current knowledge regarding the basic mechanisms controlling irradiation effect on mechanical properties is based almost entirely on the results of post-irradiation experiments or theoretical models. However, the concurrent effects of irradiation, mechanical stress, and thermal damage on the failure phenomena of materials and components remain largely unexplored due to its internal multiscale-multiphysics coupling nature. Here, we present here a concurrent irradiation-mechanics multiscale coupling model. The concurrent evolutions of nanoscale irradiation defect clusters, microscale dislocation configurations, and mechanical responses are well captured based on coupling cluster dynamics, discrete dislocation dynamics, and the finite element methods using an effective time marching scheme. Model predictions of defect densities and size are in general agreement with experimental observations. Irradiation hardening is shown to take place also in samples undergoing concurrent irradiation-mechanical loading, similar to samples tested post-irradiation. However, the occurrence of plastic flow localization and dislocation channel formation is not accompanied with apparent yield drop (softening) under concurrent irradiation-mechanical loading conditions, which is different from the post-irradiation case.

42 ENGINEERING↗

MD simulation of plastic deformation nucleation in stressed crystallites under irradiation

The investigation of plastic deformation nucleation in metals and alloys under irradiation and mechanical loading is one of the topical issues of materials science. Specific features of nucleation and evolution of the defect system in stressed and irradiated iron, vanadium, and copper crystallites were studied by molecular dynamics simulation. Mechanical loading was performed in such a way that the modeled crystallite volume remained unchanged. The energy of the primary knock-on atom initiating a cascade of atomic displacements in a stressed crystallite was varied from 0.05 to 50 keV. It was found that atomic displacement cascades might cause global structural transformations in a region far larger than the radiation-damaged area. These changes are similar to the ones occurring in the process of mechanical loading of samples. They are implemented by twinning (in iron and vanadium) or through the formation of partial dislocation loops (in copper).

36 MATERIALS SCIENCE↗

In-Situ High Energy X-ray Characterization of Tensile Deformation of Advanced Austenitic Stainless Steels

A deep understanding of the deformation mechanisms for next-generation structural materials of advanced nuclear reactors is critical to their successful applications. For this purpose, high energy synchrotron X-ray characterization techniques in combination with in situ thermo-mechanical loading have distinctive advantages in correlating the mechanical responses of the specimens with their microstructure evolution in real time. In this study, this method is employed to compare the deformation characteristics of two advanced austenitic stainless steels, NF709 steel a High-Temperature Ultrafine-Precipitate Strengthened (HT-UPS) steel, with a traditional 316 austenitic stainless steel (SS). The NF709 and HT-UPS steels are both promising candidates for next generation nuclear energy systems. The NF709 is a 20Cr-25Ni austenitic stainless steel stabilized with Nb/Ti(C,N) precipitates and possesses excellent high temperature and corrosion resistance. The HT-UPS steel (Fe-14Cr-16Ni-Ti,Nb,V) also has much improved creep resistance and high temperature performance than 316SS through the careful control of minor alloying elements to form creep resistant precipitates. While both have shown improved mechanical properties over 316SS, their deformation characteristics and underlying mechanisms are yet to be fully explored. The recent applications of simultaneous Wide-Angle X-ray Scattering (WAXS) and Small-Angle X-ray Scattering (SAXS) techniques under thermo-mechanical loading of steel samples have revealed valuable insights of the microstructural evolution during deformation. This work is to apply these techniques to characterize the deformation behaviors and also understand their relationship with the microstructures of advanced austenitic stainless steels. (authors)

36 MATERIALS SCIENCE↗

X-ray diffraction reveals blunt-force loading threshold for nanoscopic structural change in ex vivo neuronal tissues

An ex vivo blunt-force loading experiment is disclosed that may, in the future, provide insight into the molecular structural changes occurring in load-induced conditions such as traumatic brain injury (TBI). TBI appears to manifest in changes in multiple structures and elements within the brain and nervous system. Individuals with a TBI may suffer from cognitive and/or behavioral impairments which can adversely affect their quality of life. Information on the injury threshold of tissue loading for mammalian neurons is critical in the development of a quantified neuronal-level dose-response model. Such a model could aid in the discovery of enhanced methods for TBI detection, treatment and prevention. At the present time, thresholds of mechanical load leading to direct force-coupled nanostructural changes in neurons are unknown. In this study, we make use of the fact that changes in the structure and periodicity of myelin may indicate neurological damage and can be detected with X-ray diffraction (XRD). XRD allows access to a nanoscopic resolution range not readily achieved by alternative methods, nor does the experimental methodology require chemical sample fixation. In this study, XRD was used to evaluate the affects of controlled mechanical loading on myelin packing structure in ex vivo optic nerve samples. By using a series of crush tests on isolated optic nerves a quantified baseline for mechanical load was found to induce changes in the packing structure of myelin. To the authors' knowledge, this is the first report of its kind.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effects of Cyclic Loading on Mechanical Behavior of 24S-T4 and 75S-T6 Aluminum Alloys and SAE 4130 Steel

An investigation was conducted to determine the effects of cyclic loading on the mechanical behavior of 24S-T4 and 75S-T6 aluminum alloys and SAE 4130 steel. Specimens of the three materials were subjected to various numbers of prior fatigue cycles both below and above the fatigue limits. Special slow-bend tests were employed to show the effects of prior cycles of fatigue stressing on the transition temperature to brittle fracture for SAE 4130 steel and on the energy-absorption capacity of the aluminum alloys. Micrographic studies were made to observe and measure crack formation and propagation and additional special tests were conducted to supplement the results of the slow-bend tests. These included Charpy impact tests, mirohardness surveys, tension tests, and fretting-corrosion studies.

STEELS↗

Structural Modeling of an Osteoblast Subjected to Hypergravity Loading

Osteoblasts, the bone-forming cells, are sensitive to altered mechanical loads such as those induced by fluid shear forces and cyclic uniaxial tension and compression. The cytoskeleton is thought to play an important role in a cell's response to mechanical loading and to coordinate cell shape changes. While some theoretical calculations indicate that a cell should not be able to respond to relatively small changes in gravity given the magnitude of forces exerted by intracellular components, osteoblasts have been shown to respond to microgravity. In this study, we investigated whether an osteoblast can sense a constant hypergravity acceleration of 10G. We asked if this load changes the shape of an osteoblast, and if engineering modeling accurately predicts the shape change. We modeled a cell by representing it as a series of axisymmetric shell structures. To test this model empirically, we performed experiments with cultured osteoblasts to measure changes in cell shape resulting from hypergravity loading.

Globus, Ruth K.↗

A Novel Bone Marrow Single Cell Atlas of Mechanotransduction in Microgravity, Normal Gravity, Exercise, and Hindlimb Unloading for WT and CDKN1A-Null Regenerative Mice

Mechanical loading of adult stem cell progenitors is a key factor in modulating their proliferation, differentiation, and tissue regenerative potential, with loading generally promoting tissue formation and unloading mediating tissue loss. To address the role of mechanotransduction in maintaining stem cell-based tissue regenerative health, we generated a single cell transcriptomic atlas mapping responses of femur bone marrow mesenchymal and hematopoietic lineages to a range of altered mechanical loading conditions, both in WT B1629SF2/J mice as well as the p21/CDKN1A-null regenerative mice. We selected the femur marrow compartment as a model because of the diversity and high numbers of stem cell progenitor stages present, and because it undergoes static and cyclic hydrostatic pressure loading associated with weight-bearing and ambulation. Our study included normally loaded mice at 1g, unloading in microgravity during spaceflight as well as tail suspension hindlimb unloading, and voluntary running wheel exercise. Basal, one-year natural aging, and habitat controls were also conducted. Overall, the atlas encompasses 18 different experimental conditions with N=3 mice per condition and includes more than 500,000 single cell expressomes. Key specific findings include: increased mature reticulocyte populations in aging and unloading mice compared to active mice; greater hematopoietic and mesenchymal differentiating progenitors cluster identification in CDKN1A-null samples, especially the exercise model; distinct pseudotime cell trajectory shifts in the hematopoietic lineage for spaceflight and unloaded mice; and shifts in monocytic cell populations toward osteoclastic bone degenerative lineages in unloading and spaceflight samples. Overall mechanical loading shows increased marrow progenitor population differentiation while unloading is associated with increased CDKN1A expression and maintenance of marrow population stemness. Deletion of CDKN1A appears to remove a negative check on progenitor lineages commitment to differentiation. Finally, the Bone Marrow Mechanotransduction Single Cell Atlas will serve as a reference tool for studying marrow regenerative responses across a range of mechanical environments as they relate to CDKN1A status.

single-cell↗

The Physical and Engineering Limits of Coupled In situ TEM Experiments

Almost all future energy systems (advanced nuclear reactors, fusion energy system, concentrating solar-thermal power (CSP), and wind technologies) are limited by degradation of key material systems exposed to multiple environmental stressors. The degradation during exposure to high temperatures, radiation, mechanical loading, and chemical attack is often dictated by mechanisms active at the microstructural level. The nature of these mechanisms and the associated variations between sequential and concurrent interplay can be explored if the transmission electron microscope (TEM) is utilized as a toolbox for exploration [1]. One such tool developed at Sandia National Laboratories to couple several of these environments is the In situ Ion Irradiation TEM (I3TEM) [2]. Several studies over the last decade utilizing this tool have shown that the scientific intuition developed over decades of sequential experiments is not always a good indicator of concurrent mechanisms or failure routes. This presentation will highlight the recent and planned additions into the I3TEM facility of a Waviks gas injection system and Raman system, respectively, as can be seen in Fig. 1, permitting environmental degradation from gas species leaked into the pole piece region during quantitative mechanical loading (indentation, monotonic loading, high temperature creep, irradiation induced creep, and high-cycle fatigue); multi-beam ion irradiation (energies ranging from 1 keV to 48 MeV and species from H to Au); laser exposure (20 W and 1064 nm), or various combinations thereof that are already possible [3]. This addition permits the facility to explore both sequential or concurrently the four axes of stressors: thermal, mechanical, radiation, and chemical. This information can be directly coupled to modeling, expediting the refinement and validation of both atomistic and mesoscale models.

degradation↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

The Load Capability of Piezoelectric Single Crystal Actuators

Piezoelectric lead magnesium niobate-lead titanate (PMN-PT) single crystal is one of the most promising materials for electromechanical device applications due to its high electrical field induced strain and high electromechanical coupling factor. PMN-PT single crystal-based multilayer stack actuators and multilayer stack-based flextensional actuators have exhibited high stroke and high displacement-voltage ratios. The actuation capabilities of these two actuators were evaluated using a newly developed method based upon a laser vibrometer system under various loading conditions. The measured displacements as a function of mechanical loads at different driving voltages indicate that the displacement response of the actuators is approximately constant under broad ranges of mechanical load. The load capabilities of these PMN-PT single crystal-based actuators and the advantages of the capability for applications will be discussed.

Xu, Tian-Bing↗

Genetic interactions between polycystin-1 and Wwtr1 in osteoblasts define a novel mechanosensing mechanism regulating bone formation in mice

Molecular mechanisms transducing physical forces in the bone microenvironment to regulate bone mass are poorly understood. Here, we used mouse genetics, mechanical loading, and pharmacological approaches to test the possibility that polycystin-1 and Wwtr1 have interdependent mechanosensing functions in osteoblasts. We created and compared the skeletal phenotypes of control Pkd1 flox/+ ;Wwtr1 flox/+ , Pkd1 Oc-cKO , Wwtr1 Oc-cKO , and Pkd1/Wwtr1 Oc-cKO mice to investigate genetic interactions. Consistent with an interaction between polycystins and Wwtr1 in bone in vivo, Pkd1/Wwtr1 Oc-cKO mice exhibited greater reductions of BMD and periosteal MAR than either Wwtr1 Oc-cKO or Pkd1 Oc-cKO mice. Micro-CT 3D image analysis indicated that the reduction in bone mass was due to greater loss in both trabecular bone volume and cortical bone thickness in Pkd1/Wwtr1 Oc-cKO mice compared to either Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Pkd1/Wwtr1 Oc-cKO mice also displayed additive reductions in mechanosensing and osteogenic gene expression profiles in bone compared to Pkd1 Oc-cKO or Wwtr1 Oc-cKO mice. Moreover, we found that Pkd1/Wwtr1 Oc-cKO mice exhibited impaired responses to tibia mechanical loading in vivo and attenuation of load-induced mechanosensing gene expression compared to control mice. Finally, control mice treated with a small molecule mechanomimetic, MS2 that activates the polycystin complex resulted in marked increases in femoral BMD and periosteal MAR compared to vehicle control. In contrast, Pkd1/Wwtr1 Oc-cKO mice were resistant to the anabolic effects of MS2. These findings suggest that PC1 and Wwtr1 form an anabolic mechanotransduction signaling complex that mediates mechanical loading responses and serves as a potential novel therapeutic target for treating osteoporosis.

60 APPLIED LIFE SCIENCES↗

Nonlinear response of boron/aluminum angleplied laminates under cyclic tensile loading: Contributing mechanisms and their effects

The nonlinear response of boron/aluminum angleplied laminates subjected to cyclic loads was investigated. A procedure is outlined and criteria are proposed which can be used to assess the nonlinear response. The procedure consists of testing strategically selected laminate configurations and analyzing the results using composite mechanics. Results from the investigation show the contributions to nonlinear behavior are from: premature random fiber breaks where the ply orientation angle is small relative to the load direction, ply relative rotation at intermediate values of the ply orientation angle, and nonlinear aluminum matrix behavior at large values of the orientation angle. Premature fiber breaks result in progressively more compliant material; large ply relative rotations result in progressively stiffer material; and pronounced matrix nonlinear behavior results in no significant change in the stiffness of the initial load portion.

Chamis, C. C.↗

Nonlinear response of boron/aluminum angleplied laminates under cyclic tensile loading - Contributing mechanisms and their effects

The nonlinear response of boron/aluminum angleplied laminates subjected to cyclic loads was investigated. A procedure is outlined and criteria are proposed which can be used to assess the nonlinear response. The procedure consists of testing strategically selected laminate configurations and analyzing the results using composite mechanics. Results from the investigation show the contributions to nonlinear behavior are from: premature random fiber breaks where the ply orientation angle is small relative to the load direction, ply relative rotation at intermediate values of the ply orientation angle, and nonlinear aluminum matrix behavior at large values of the orientation angle. Premature fiber breaks result in progressively more compliant material; large ply relative rotations result in progressively stiffer material; and pronounced matrix nonlinear behavior results in no significant change in the stiffness of the initial load portion.

Chamis, C. C.↗

Alterations in gut transport of minerals and in binding proteins during simulated weightlessness

The structural components of the skeleton develop and are maintained in a 1 g environment, shaped by the mechanical load to which they are constantly exposed. Altering such a mechanical load by reducing the gravitational force imposed on the system, as in space flight, has profound effects on the skeleton and permits an exploration of the molecular events which regulate normal skeletal homeostasis. The objective was to determine whether simulated weightlessness reduced intestinal calcium transport, and if so, to determine the molecular mechanisms for such an effect. A nonstressful tail suspension in which the rats gained weight normally while suspended was used to simulate weightlessness. A significant change in intestinal calcium transport was not demonstrated. However, a cyclic change in bone formation with suspension was shown. Based on these observations, the objective changed to determination of the hormonal regulation of bone formation during simulated weightlessness.

Bikle, D. D.↗

Transfer Mechanisms for Heavy Loads

Soft hydraulic system gently maneuvers loads. Upper and lower load-transfer mechanisms attach through mounting holes in vertical beam adjustable or gross positioning. Fine positioning of load accomplished by hydraulic cylinders that move trunnion support and trunnion clamp through short distances. Useful in transferring large loads in railroads, agriculture, shipping, manufacturing, and even precision assembly of large items.

Cassisi, V.↗

Preliminary 2-D shell analysis of the space shuttle solid rocket boosters

A two-dimensional shell model of an entire solid rocket booster (SRB) has been developed using the STAGSC-1 computer code and executed on the Ames CRAY computer. The purpose of these analyses is to calculate the overall deflection and stress distributions for the SRB when subjected to mechanical loads corresponding to critical times during the launch sequence. The mechanical loading conditions for the full SRB arise from the external tank (ET) attachment points, the solid rocket motor (SRM) pressure load, and the SRB hold down posts. The ET strut loads vary with time after the Space Shuttle main engine (SSME) ignition. The SRM internal pressure varies axially by approximately 100 psi. Static analyses of the full SRB are performed using a snapshot picture of the loads. The field and factory joints are modeled by using equivalent stiffness joints instead of detailed models of the joint. As such, local joint behavior cannot be obtained from this global model.

Knight, Norman F., Jr.↗

Mobility power flow analysis of coupled plate structure subjected to mechanical and acoustic excitation

The mobility power flow approach that was previously applied in the derivation of expressions for the vibrational power flow between coupled plate substructures forming an L configuration and subjected to mechanical loading is generalized. Using the generalized expressions, both point and distributed mechanical loads on one or both of the plates can be considered. The generalized approach is extended to deal with acoustic excitation of one of the plate substructures. In this case, the forces (acoustic pressures) acting on the structure are dependent on the response of the structure because of the scattered pressure component. The interaction between the plate structure and the acoustic fluid leads to the derivation of a corrected mode shape for the plates' normal surface velocity and also for the structure mobility functions. The determination of the scattered pressure components in the expressions for the power flow represents an additional component in the power flow balance for the source plate and the receiver plate. This component represents the radiated acoustical power from the plate structure. For a number of coupled plate substrates, the acoustic pressure generated by one substructure will interact with the motion of another substructure. That is, in the case of the L-shaped plate, acoustic interaction exists between the two plate substructures due to the generation of the acoustic waves by each of the substructures. An approach to deal with this phenomena is described.

Cuschieri, J. M.↗